984 resultados para 7-66


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, we test the electroweak sector of the Standard Model of particle physics through the measurements of the cross section of the simultaneous production of the neutral weak boson Z and photon γ, and the limits on the anomalous Zγγ and ZZγ triple gauge couplings h3 and h4 with the Z decaying to leptons (electrons and muons). We analyze events collected in proton-proton collisions at center of mass energy of sqrt(s) = 7 TeV corresponding to an integrated luminosity of 5.0 inverse femtobarn. The analyzed events were recorded by the Compact Muon Solenoid detector at the Large Hadron Collider in 2011.

The production cross section has been measured for hard photons with transverse momentum greater than 15 GeV that are separated from the the final state leptons in the eta-phi plane by Delta R greater than 0.7, whose sum of the transverse energy of hadrons over the transverse energy of the photon in a cone around the photon with Delta R less than 0.3 is less than 0.5, and with the invariant mass of the dilepton system greater than 50 GeV. The measured cross section value is 5.33 +/- 0.08 (stat.) +/- 0.25 (syst.) +/- 0.12 (lumi.) picobarn. This is compatible with the Standard Model prediction that includes next-to-leading-order QCD contributions: 5.45 +/- 0.27 picobarn.

The measured 95 % confidence-level upper limits on the absolute values of the anomalous couplings h3 and h4 are 0.01 and 8.8E-5 for the Zγγ interactions, and, 8.6E-3 and 8.0E-5 for the ZZγ interactions. These values are also compatible with the Standard Model where they vanish in the tree-level approximation. They extend the sensitivity of the 2012 results from the ATLAS collaboration based on 1.02 inverse femtobarn of data by a factor of 2.4 to 3.1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of physico-chemical parameters and plankton composition on fish production in ponds was investigated in six fish farms for eight weeks. The physicochemical parameters investigated were temperature=25-30 plus or minus C, transparency=0.45-0.57m, dissolved oxygen=3.0-10.9mg/l, pH=6.0-7.7, dissolved carbon dioxide=5.46-28.3mg/l, total alkalinity=44.37-80.0ppm, chemical oxygen demand=31.88-72.18mg/l and biological oxygen demand=0.66-48.34mg/l. Plankton composition varies and was made of four families of phytoplankton namely; Cyanophyceae, Chlorophyceae, Dinophyceae and Diatomida; and four families of zooplankton viz; Protozoa, Rotifera, Copepoda and Dinoflagellates. Farm 1 and 6 recorded the highest average weight of about 1.0kg and average total length of about 40.0cm for the two fish species. This study showed that fish yield was dependable on the quality and management of pond water characteristics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of physico-chemical parameters and plankton composition on fish production in ponds was investigated in six fish farms for eight weeks. The physicochemical parameters investigated were temperature=25-30 plus or minus C, transparency=0.45-0.57m, dissolved oxygen=3.0-10.9mg/l, pH=6.0-7.7, dissolved carbon dioxide=5.46-28.3mg/l, total alkalinity=44.37-80.0ppm, chemical oxygen demand=31.88-72.18mg/l and biological oxygen demand=0.66-48.34mg/l. Plankton composition varies and was made of four families of phytoplankton namely: Cyanophyceae, Chlorophyceae, Dinophyceae and Diatomida; and four families of zooplankton viz: Protozoa, Rotifera, Copepoda and Dinoflagellates. Farm 1 and 6 recorded the highest average weight of about 1.0kg and average total length of about 40.0cm for the two fish species. This study showed that fish yield was dependable on the quality and management of pond water characteristics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了一种高重复频率掺钛蓝宝石飞秒激光多通高效率放大系统.在抽运功率为23W,入射功率为660mW时,获得7.2W的放大输出,放大效率达30%.经压缩器压缩后,获得单脉冲能量4.5mJ,脉冲宽度为38fs,重复频率为1kHz,峰值功率大于0.1TW的超短超强激光脉冲.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of terl-butylperoxide complexes of hafnium, Cp*2Hf(R)(OOCMe3) (Cp* = ((η5-C5Me5); R = Cl, H, CH3, CH2CH3, CH2CH2CH3, CH2CH2CH2CH3, CH2CHMe2, CH=CHCMe3, C6H5, meta-C6H3(CH2)2) and Cp*(η5-C5(CH3)4CH2CH2CH2)Hf(OOCMe3), has been synthesized. One example has been structurally characterized, Cp*2Hf(OOCMe3)CH2CH3 crystallizes in space group P21/c, with a = 19.890(7)Å, b = 8.746(4)Å, c = 17.532(6)Å, β = 124.987(24)°, V = 2498(2)Å3, Z = 4 and RF = 0.054 (2222 reflections, I > 0). Despite the coordinative unsaturation of the hafnium center, the terl-butylperoxide ligand is coordinated in a mono-dentate ligand. The mode of decomposition of these species is highly dependent on the substituent R. For R = H, CH2CH3, CH2CH2CH3, CH2CH2CH2CH3, CH2CHMe2 a clean first order conversion to Cp*2Hf(OCMe3)(OR) is observed (for R CH2CH3, ΔHǂ = 19.6 kcal•mol-1, ΔSǂ = -13 e.u.). These results are discussed in terms of a two step mechanism involving η2-coordination of the terl-butylperoxide ligand. Homolytic O-O bond cleavage is observed upon heating of Cp*2Hf(OOCMe3) R (R = C6H6, meta-C6H3(CH3)2). In the presence of excess 9,10-dihydroanthracene thermolysis of Cp*2Hf(OOCMe3)C6H6 cleanly affords Cp*2Hf(C6H6)OH and HOCMe3 (ΔHǂ = 22.6 kcal•mol-1, ΔSǂ = -9 e.u.). The O-O bond strength in these complexes is thus estimated to be 22 kcal•mol-1.

Cp*2Ta(CH2)H, Cp*2Ta(CHC6H5)H, Cp*2Ta(C6H4)H, Cp*2Ta(CH2=CH2)H and Cp*2Ta(CH2=CHMe)H react, presumably through Cp*2Ta-R intermediates, with H2O to give Cp*2Ta(O)H and alkane. Cp*2Ta(O)H was structurally characterized: space group P21/n, a= 13.073(3)Å, b = 19.337(4)Å, c = 16.002(3)Å, β = 108.66(2)°, V = 3832(1)Å3, Z = 8 and RF = 0.0672 (6730 reflections). Reaction of terlbutylhydroperoxide with these same starting materials ultimately yields Cp*2Ta(O)R and HOCMe3. Cp*2Ta(CH2=CHR)OH species are proposed as intermediates in the olefin hydride reactions. Cp*2Ta(O2)R species can be generated from the reaction of the same starting materials and O2. Lewis acids have been shown to promote oxygen insertion in these complexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical microscopy is an essential tool in biological science and one of the gold standards for medical examinations. Miniaturization of microscopes can be a crucial stepping stone towards realizing compact, cost-effective and portable platforms for biomedical research and healthcare. This thesis reports on implementations of bright-field and fluorescence chip-scale microscopes for a variety of biological imaging applications. The term “chip-scale microscopy” refers to lensless imaging techniques realized in the form of mass-producible semiconductor devices, which transforms the fundamental design of optical microscopes.

Our strategy for chip-scale microscopy involves utilization of low-cost Complementary metal Oxide Semiconductor (CMOS) image sensors, computational image processing and micro-fabricated structural components. First, the sub-pixel resolving optofluidic microscope (SROFM), will be presented, which combines microfluidics and pixel super-resolution image reconstruction to perform high-throughput imaging of fluidic samples, such as blood cells. We discuss design parameters and construction of the device, as well as the resulting images and the resolution of the device, which was 0.66 µm at the highest acuity. The potential applications of SROFM for clinical diagnosis of malaria in the resource-limited settings is discussed.

Next, the implementations of ePetri, a self-imaging Petri dish platform with microscopy resolution, are presented. Here, we simply place the sample of interest on the surface of the image sensor and capture the direct shadow images under the illumination. By taking advantage of the inherent motion of the microorganisms, we achieve high resolution (~1 µm) imaging and long term culture of motile microorganisms over ultra large field-of-view (5.7 mm × 4.4 mm) in a specialized ePetri platform. We apply the pixel super-resolution reconstruction to a set of low-resolution shadow images of the microorganisms as they move across the sensing area of an image sensor chip and render an improved resolution image. We perform longitudinal study of Euglena gracilis cultured in an ePetri platform and image based analysis on the motion and morphology of the cells. The ePetri device for imaging non-motile cells are also demonstrated, by using the sweeping illumination of a light emitting diode (LED) matrix for pixel super-resolution reconstruction of sub-pixel shifted shadow images. Using this prototype device, we demonstrate the detection of waterborne parasites for the effective diagnosis of enteric parasite infection in resource-limited settings.

Then, we demonstrate the adaptation of a smartphone’s camera to function as a compact lensless microscope, which uses ambient illumination as its light source and does not require the incorporation of a dedicated light source. The method is also based on the image reconstruction with sweeping illumination technique, where the sequence of images are captured while the user is manually tilting the device around any ambient light source, such as the sun or a lamp. Image acquisition and reconstruction is performed on the device using a custom-built android application, constructing a stand-alone imaging device for field applications. We discuss the construction of the device using a commercial smartphone and demonstrate the imaging capabilities of our system.

Finally, we report on the implementation of fluorescence chip-scale microscope, based on a silo-filter structure fabricated on the pixel array of a CMOS image sensor. The extruded pixel design with metal walls between neighboring pixels successfully guides fluorescence emission through the thick absorptive filter to the photodiode layer of a pixel. Our silo-filter CMOS image sensor prototype achieves 13-µm resolution for fluorescence imaging over a wide field-of-view (4.8 mm × 4.4 mm). Here, we demonstrate bright-field and fluorescence longitudinal imaging of living cells in a compact, low-cost configuration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-cycle optical pulses with duration of 5 fs and energy of 0.7 mJ have been generated at 1 kHz by compressing the 38 fs laser pulses from a carrier-envelope phase (CEP) controlled Ti:sapphire laser system through a cascade filamentation compression technique. A simple and effective method is developed to suppress multiple filament formation and stabilize a single filament by inserting a soft aperture with an appropriate diameter into the driving laser beam prior to focusing, resulting in an excellent compressed beam quality. The good beam quality and potentially higher peak power make this ultrashort laser pulse source a significant tool for high-field physics applications. (C) 2007 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objeto de estudo foi o preparo e a administração de medicamentos por cateter pela enfermagem em pacientes que recebem nutrição enteral. O objetivo geral foi investigar o padrão de preparo e administração dos medicamentos por cateter em pacientes que recebem nutrição enteral concomitante. Os objetivos específicos foram apresentar o perfil dos medicamentos preparados e administrados de acordo com a possibilidade de serem administrados por cateter enteral e avaliar o tipo e a freqüência de erros que ocorrem no preparo e administração de medicamentos por cateter. Tratou-se de uma pesquisa com desenho transversal de natureza observacional, sem modelo de intervenção. Foi desenvolvida em um hospital do Rio de Janeiro onde foram observados técnicos de enfermagem preparando e administrando medicamentos por cateter na Unidade de Terapia Intensiva. Foram observadas 350 doses de medicamentos sendo preparados e administrados. Os grupos de medicamentos prevalentes foram os que agem no Sistema Cardiovascular Renal com 164 doses (46,80%), seguido pelos que agem no Sistema Respiratório e Sangue com 12,85% e 12,56% respectivamente. Foram encontrados 19 medicamentos diferentes do primeiro grupo, dois no segundo e cinco no terceiro. As categorias de erro no preparo foram trituração, diluição e misturas. Encontrou-se uma taxa média de 67,71% no preparo de medicamentos. Comprimidos simples foram preparados errados em 72,54% das doses, e todos os comprimidos revestidos e de liberação prolongada foram triturados indevidamente entre sólidos a categoria de erro prevalente foi trituração com 45,47%, preparar misturando medicamentos foi um erro encontrado em quase 40% das doses de medicamentos sólidos. A trituração insuficiente ocorreu em 73,33% das doses de ácido fólico, do cloridrato de amiodarona (58,97%) e bromoprida (50,00%). A mistura com outros medicamentos ocorreu em 66,66% das doses de bromoprida, de besilato de anlodipina (53,33%), bamifilina (43,47%), ácido fólico (40,00%) e ácido acetilsalicílico (33,33%). Os erros na administração foram ausência de pausa e manejo indevido do cateter. A taxa média de erros na administração foi de 32,64%, distribuídas entre 17,14% para pausa e 48,14% para manejo do cateter. A ausência de lavagem do cateter antes foi o erro mais comum e o mais incomum foi não lavar o cateter após a administração. Os medicamentos mais envolvidos em erros na administração foram: cloridrato de amiodarona (n=39), captopril (n=33), cloridrato de hidralazina (n=7), levotiroxina sódica (n=7). Com relação à lavagem dos cateteres antes, ela não ocorreu em 330 doses de medicamentos. O preparo e administração inadequados de medicamentos podem levar à perdas na biodisponibilidade, diminuição do nível sérico e riscos de intoxicações para o paciente. Preparar e administrar medicamentos são procedimentos comuns, porém apresentou altas taxas de erros, o que talvez reflita pouco conhecimento desses profissionais sobre as boas práticas da terapia medicamentosa. Constata-se a necessidade de maior investimento de todos os profissionais envolvidos, médicos, enfermeiros e farmacêuticos nas questões que envolvam a segurança com medicamentos assim como repensar o processo de trabalho da enfermagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of a thermoelectric material is judged by the size of its temperature de- pendent thermoeletric-figure-of-merit (zT ). Superionic materials, particularly Zn4Sb3 and Cu2Se, are of current interest for the high zT and low thermal conductivity of their disordered, superionic phase. In this work it is reported that the super-ionic materials Ag2Se, Cu2Se and Cu1.97Ag0.03Se show enhanced zT in their ordered, normal ion-conducting phases. The zT of Ag2Se is increased by 30% in its ordered phase as compared to its disordered phase, as measured just below and above its first order phase transition. The zT ’s of Cu2Se and Cu1.97Ag0.03Se both increase by more than 100% over a 30 K temperatures range just below their super-ionic phase transitions. The peak zT of Cu2Se is 0.7 at 406 K and of Cu1.97Ag0.03Se is 1.0 at 400 K. In all three materials these enhancements are due to anomalous increases in their Seebeck coefficients, beyond that predicted by carrier concentration measurements and band structure modeling. As the Seebeck coefficient is the entropy transported per carrier, this suggests that there is an additional quantity of entropy co-transported with charge carriers. Such co-transport has been previously observed via co-transport of vibrational entropy in bipolaron conductors and spin-state entropy in NaxCo2O4. The correlation of the temperature profile of the increases in each material with the nature of their phase transitions indicates that the entropy is associated with the thermodynamcis of ion-ordering. This suggests a new mechanism by which high thermoelectric performance may be understood and engineered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES]El trabajo fin grado desarrollado en este documento consiste en la realización de una interfaz gráfica que permita analizar la precisión, en la medida de armónicos e interarmónicos de señales eléctricas de tensión y corriente, de diferentes técnicas que buscan la sincronización de la frecuencia de muestreo con la frecuencia fundamental. Se estudian diferentes técnicas de estimación de la frecuencia fundamental y diferentes técnicas de remuestreo aplicadas a señales analíticas de las que se conocen su frecuencia fundamental y su contenido armónico. Estas técnicas de procesado tienen como objetivo mejorar en la medida del contenido armónico haciendo disminuir, mediante la sincronización de la frecuencia de muestreo, el error que se comete debido a la dispersión espectral provocada por el enventanado de las señales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During late - and post-glacial times lakes played a leading role in the development of the landscape of the North-west European part of USSR. A variety of geographic circumstances created great variegation of natural conditions in lakes and determined the composition of their diatoms. The basic stages of the development of the diatom flora of lakes are linked with general climatic changes. The deepwater regions of large periglacial lakes of the North-west USSR are inhabited by plankton diatoms of the genera Melosira and Cyclotella. Diatom analysis is further applied for the study of the history of the lakes of north-west USSR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigations on the control of the embryonic and post-embryonic development of arthropods have formed an intensively studied field of zoological research for a long time, Here in especially favourable cases the causal chain from the operation of external factors on the influence of physiological mechanisms, eg. of the hormone variety, is known right through to its primary influences. A comparative approach to the relevant questions was in the main only made in the case of the insects. For crustacea , investigations are available almost exclusively only for the malacostraca. This study examines the influence of the factors of temperature and photoperiod on the entire development of Cyclops vicinus. Tests were made on whether the light-darkness change serves as a regulator for a possible existing molting rhythm - a question which for the entire arthropods has been settled only very rarely. The basic material for the cultures that were examined originates from Lake Constance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

反射式光栅对是一种具有负色散性质的器件,可用于飞秒激光脉冲的压缩和展宽,具有无材料色散的优点。给出了一种基于多台阶反射光栅的脉冲压缩装置。该装置为倍密度光栅结构,由两个周期分别为40μm和20μm的四台阶反射式光栅组成。实验得到的衍射效率可以达到70%以上,输入脉冲经过两个光栅的衍射后会按原路返回,从而达到色散补偿的效果。利用此压缩装置,脉冲宽度为66.8 fs的输入脉冲压缩至接近傅里叶变换极限脉冲,即46.6 fs,由此证明只要多台阶光栅效率足够高,此装置就有可能成为不同于棱镜对进行飞秒脉冲腔内和腔外压缩的另一种途径。