951 resultados para vertical grids


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of warm-up on agility (AG) and on vertical jump (VJ) tests in youth soccer players. Sixteen players performed the AG and VJ tests without warm-up (NW) and with warm-up (WW) randomly, within two weeks, at least 48 h interval, during season. The warm-up was performed only a light running during 10 min. The paired t-test identified significant difference (p <0,05) between the NW and WW conditions in the tests of SR and CJ (9,14 +/- 0,28 vs 8,94 +/- 0,30 s e 51,4 +/- 4,2 vs 54,5 +/- 6,4 cm, respectively). The warm-up performed on light intensity running was effective to improve the AG and VJ tests performance in youth soccer players.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into quasi-modes a, b and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In systems that combine the outputs of classification methods (combination systems), such as ensembles and multi-agent systems, one of the main constraints is that the base components (classifiers or agents) should be diverse among themselves. In other words, there is clearly no accuracy gain in a system that is composed of a set of identical base components. One way of increasing diversity is through the use of feature selection or data distribution methods in combination systems. In this work, an investigation of the impact of using data distribution methods among the components of combination systems will be performed. In this investigation, different methods of data distribution will be used and an analysis of the combination systems, using several different configurations, will be performed. As a result of this analysis, it is aimed to detect which combination systems are more suitable to use feature distribution among the components

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presença marcante de uma prosa-poética na produção ficcional de Clarice Lispector possibilitou-nos exemplificar algumas noções centrais (tempo vertical e instante poético) na rica e sugestiva reflexão de Gaston Bachelard acerca do universo poético

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate through radiographic and microscopic analysis the efficiency of the filling techniques by vertical hidraulic compression after the root canal mechanical instrumentation in vitro as well to evaluate the marginal apical leakage through macroscopic and microscopic analysis. Thirty human mandibular molars were used , they were divided on three groups, these were subdivided on six subgroups with five specimens each, come down to 106 root canals filled. Initially, the teeth were instrumented with Profile system series 29 and filled with two ways: single accessory cone or single cone associated with gutta-percha secundary cone, with Fill Canal sealer or Sealer 26. Completed the filling, the teeth were coated with araldit and finger -nail polish except for the apical 2 mm and dried for 3 hours, thep radiographs were taken of the teeth in orto and disto-radiai directions. Next, the coronal seal was carried out with composite resin photopolymerized and with their process of making impermeable. Teeth of positive controls were used without araldit and finger-nail polish whereas the negative controls were used with total coat of araldit and finger-nail polish. The specimens were placed in 2% Methylene Blue dye for 24 hours and thermocycled for 7 days. Afterwards, sections were made of each tooth at mesial and distal roat, after this the teeth were radiographed at buccolíngual direction for a macroscopic analysis and at buccolingual and mesiodistal directions for assessment of the marginal apical leakage. Cross sections were made 3 mm to 3mm since the tooth apice. The sections obtained for each group were observed with a stereomicroscope to evaluate the quality of the root canal filling and the marginal apical leakage. The results showed that: In the four techniques the marginal dye leakage was present in the apical third; in all groups the quality of the root canal filling in the radiography was better at mesial root canal and the single cone technique showed inefficient when only a single distal root canal was present. In the radiographic evaluation the best quality of the root canal filling was observed in the 1A group (single accessory cone + FiIl Canal), as in the mesial root as in the distal root wich Shcwed twe root canals: when the distaI root had only one canal. the best result was showed by 28 group (single accessory cone associated with secundary cone + Fill Canal) In the macroscopic analysis of longitudinal !eaKage (outside surface). less leakage was showed as In the mesial root as in the distal root in the negative control group (3) followed 2A group (single accessory cone + Sealer 26). When the microscopic analysis of tranversal leakage of both roots (inside surface) was carried out. the groups that showed less dye leakage were the negative control (38) followed the 28 group (single acessory cone associated with secundary cone + Sealer 26). The homogeneity o filling was best noted in the 1 A group (.single accessoty cone + Fill Canal). The groups that showed less dye penetration in the tranversal leakage (total area) were negative control (3B) and 2B

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present the methodological procedures involved in the digital imaging in mesoscale of a block of travertines rock of quaternary age, originating from the city of Acquasanta, located in the Apennines, Italy. This rocky block, called T-Block, was stored in the courtyard of the Laboratório Experimental Petróleo "Kelsen Valente" (LabPetro), of Universidade Estadual de Campinas (UNICAMP), so that from it were performed Scientific studies, mainly for research groups universities and research centers working in brazilian areas of reservoir characterization and 3D digital imaging. The purpose of this work is the development of a Model Solid Digital, from the use of non-invasive techniques of digital 3D imaging of internal and external surfaces of the T-Block. For the imaging of the external surfaces technology has been used LIDAR (Light Detection and Range) and the imaging surface Interior was done using Ground Penetrating Radar (GPR), moreover, profiles were obtained with a Gamma Ray Gamae-spectômetro laptop. The goal of 3D digital imaging involved the identification and parameterization of surface geological and sedimentary facies that could represent heterogeneities depositional mesoscale, based on study of a block rocky with dimensions of approximately 1.60 m x 1.60 m x 2.70 m. The data acquired by means of terrestrial laser scanner made available georeferenced spatial information of the surface of the block (X, Y, Z), and varying the intensity values of the return laser beam and high resolution RGB data (3 mm x 3 mm), total points acquired 28,505,106. This information was used as an aid in the interpretation of radargrams and are ready to be displayed in rooms virtual reality. With the GPR was obtained 15 profiles of 2.3 m and 2 3D grids, each with 24 sections horizontal of 1.3 and 14 m vertical sections of 2.3 m, both the Antenna 900 MHz to about 2600 MHz antenna. Finally, the use of GPR associated with Laser Scanner enabled the identification and 3D mapping of 3 different radarfácies which were correlated with three sedimentary facies as had been defined at the outset. The 6 profiles showed gamma a low amplitude variation in the values of radioactivity. This is likely due to the fact of the sedimentary layers profiled have the same mineralogical composition, being composed by carbonate sediments, with no clay in siliciclastic pellitic layers or other mineral carrier elements radioactive

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo avalia os fatores maternos e fetais envolvidos na transmissão vertical do HIV-1 em 47 pares de mãe e filho. As variáveis comportamentais, demográficas e obstétricas foram obtidas mediante entrevista; os dados referentes ao parto e ao recém-nascido, dos prontuários das maternidades. Durante o terceiro trimestre de gestação foi realizada a contagem da carga viral materna e dos linfócitos T CD4+. A média de idade foi de 25 anos e 23,4% das gestantes eram primigestas, e o fator comportamental mais prevalente foi não usar preservativos. Dentre as gestantes, 48,9% tinham células CD4+ superior a 500 células/mm³ e 93,6% se enquadravam na categoria clínica A; 95,7% submeteram-se à profilaxia com zidovudina durante a gestação ou no parto, a qual foi ministrada a todos os recém-nascidos; 50,0% delas foram submetidas à cesárea eletiva. Apesar de expostas a vários fatores de risco e protetores, nenhuma criança tornou-se infectada. A transmissão vertical resulta de um desequilíbrio entre os fatores, com predomínio dos de risco sobre os protetores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to describe the treatment used in an elderly patient presenting with bruxism and dental erosion, with good gingival health and bone support, but with decreased occlusal vertical dimension (OVD). The oral rehabilitation of elderly patients presenting with bruxism in association with tooth erosion has been a great challenge for dentists. The loss of OVD, the presence of occlusal instability and the absence of an effective anterior guide due excessive dental wear, can damage stomatognathic system (SS) biology, the function and the aesthetics. In the first treatment stage, an overlay removable partial denture (ORPD) was fabricated for the immediate re-establishment of function and aesthetics. After a 2-month follow up, with the patient presenting no symptoms, a second rehabilitation stage was accomplished, with fixed and removable prostheses. Oral rehabilitation with an ORPD was able to re-establish the SS biology, but a correct diagnosis and treatment plan are essential for success. The ORPD is a non-invasive and reversible restoring modality for general dentists that allow the re-establishment of the patient's immediate aesthetics and function at low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: na presente pesquisa utilizou-se o aparelho Hyrax tendo como objetivo avaliar as alterações transversais e verticais da maxila. Foram selecionados 20 pacientes de ambos os gêneros, entre 7 e 11 anos de idade, que apresentavam mordida cruzada posterior uni ou bilateral. METODOLOGIA: foram realizadas telerradiografias em norma frontal (PA) antes e após a expansão. A fim de evitar que a falta de padronização dessas radiografias pudesse influenciar nos resultados, idealizou-se um método de padronização para tais radiografias. RESULTADOS E CONCLUSÕES: os resultados mostraram que a correção da mordida cruzada posterior com o aparelho Hyrax, que ocorreu em todos os casos, foi em função tanto da abertura da sutura palatina mediana como também da inclinação dos molares. A medida JgE-JgD relacionada com a expansão maxilar aumentou significantemente em todos os casos tratados. Nas avaliações dentárias, as medidas verticais não apresentaram diferenças significantes, ao contrário das medidas transversais (FTE-FTD; FBE-FBD; LO.BTE; LO.BTD; BTE.BTD). A largura da cavidade nasal também aumentou significantemente (CNE-CND). O método de padronização proposto permite, portanto, utilizar as medidas que avaliam a expansão rápida da maxila, através das radiografias póstero-anteriores, com segurança, também no sentido vertical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. An increase in occlusal vertical dimension (OVD) may occur after processing complete dentures. Although many factors that generate this change are known, no information is available in the dental literature regarding the effect that the occlusal scheme may have on the change in OVD.Purpose. This in vitro study compared the increase in OVD, after processing, between complete dentures with teeth arranged in lingualized balanced occlusion and conventional balanced occlusion.Material and methods. Thirty sets of complete dentures were evaluated as follows: 15 sets of complete dentures were arranged in conventional balanced occlusion (control) and 15 sets of complete dentures were arranged in lingualized balanced occlusion. All dentures were compression molded with a long polymerization cycle. The occlusal vertical dimension was measured with a micrometer (mm) before and after processing each set of dentures. Data were analyzed using an independent t test (alpha=.05).Results. The mean increase in the OVD, after processing, was 0.87 +/- 0.21 mm for the control group and 0.90 +/- 0.27 mm for the experimental group. There was no significant difference between the groups.Conclusion. After processing, dentures set in lingualized balanced occlusion showed an increase in OVD similar to those set in conventional balanced occlusion.