994 resultados para semi-inclusive deep inelastic scattering
Resumo:
The bryozoan fauna growing on deep-water corals (Lophelia, Madrepora) from the upper-slope of Catalonia (Blanes and Banyuls-sur-mer: NW Mediterranean Sea) was studied. Among the 36 species recorded, a new species, Escharella acuta sp. nov., and a new subspecies, Escharina dutertrei protecta ssp. nov., are described; five other species have been rarely reported or were unknown from the Mediterranean Sea (Copidozoum exiguum, Amphiblestrum flemingii, Schizomavella neptuni, Smittina crystallina, Phylactellipora eximia) . This epibiotic bryozoan fauna differs clearly from shallow-water assemblages and comprises a greater proportion of boreo-atlantic species.
Resumo:
Introduction La stimulation cérébrale profonde est reconnue comme étant un traitement efficace des pathologies du mouvement. Nous avons récemment modifié notre technique chirurgicale, en limitant le nombre de pénétrations intracérébrales à trois par hémisphère. Objectif Le premier objectif de cette étude est d'évaluer la précision de l'électrode implantée des deux côtés de la chirurgie, depuis l'implémentation de cette technique chirurgicale. Le deuxième objectif est d'étudier si l'emplacement de l'électrode implantée était amélioré grâce à l'électrophysiologie. Matériel et méthode Il s'agit d'une étude rétrospective reprenant les protocoles opératoires et imageries à résonnance magnétique (IRM) cérébrales de 30 patients ayant subi une stimulation cérébrale profonde bilatérale. Pour l'électrophysiologie, nous avons utilisé trois canules parallèles du « Ben Gun », centrées sur la cible planifiée grâce à l'IRM. Les IRM pré- et post-opératoires ont été fusionnées. La distance entre la cible planifiée et le centre de l'artéfact de l'électrode implantée a été mesurée. Résultats Il n'y a pas eu de différence significative concernant la précision du ciblage des deux côtés (hémisphères) de la chirurgie. Il y a eu plus d'ajustements peropératoires du deuxième côté de la chirurgie, basé sur l'électrophysiologie, ce qui a permis d'approcher de manière significative la cible planifiée grâce à l'IRM, sur l'axe médio- latéral. Conclusion Il y a plus d'ajustements nécessaires de la position de la deuxième électrode, possiblement en lien avec le « brain shift ». Nous suggérons de ce fait d'utiliser une trajectoire d'électrode centrale accompagnée par de l'électrophysiologie, associé à une évaluation clinique. En cas de résultat clinique sub-optimal, nous proposons d'effectuer une exploration multidirectionnelle.
Resumo:
We use the analogy between scattering of a wave from a potential, and the precession of a spin-half particle in a magnetic field, to gain insight into the design of an antireflection coating for electrons in a semiconductor superlattice. It is shown that the classic recipes derived for optics are generally not applicable due to the different dispersion law for electrons. Using the stability conditions we show that a Poisson distribution of impedance steps is a better approximation than is a Gaussian distribution. Examples are given of filters with average transmissivity exceeding 95% over an allowed band.
Resumo:
OBJETIVO: Verificar o efeito da mudança no contraste do objeto, tempo de exposição e dose de radiação quando diferentes espessuras de filtração de molibdênio (Mo) e ródio (Rh) são empregadas em mamógrafos. MATERIAIS E MÉTODOS: Realizaram-se medidas da exposição na entrada da pele com uma câmara de ionização para diferentes espessuras para os filtros de Mo e Rh. Para determinar a dose glandular média foi utilizado simulador de BR12 (50% tecido adiposo e 50% tecido glandular) de diferentes espessuras (4 cm e 8 cm). Energias na faixa de 24 kVp a 34 kVp foram empregadas e filmes Kodak MinR 2000 foram utilizados. RESULTADOS: Os resultados evidenciaram dados de contraste do objeto, dose glandular e tempo de exposição para diferentes espessuras de filtros adicionais e diferentes tensões. Esses dados indicaram aumento nos valores de contraste do objeto e tempo de exposição, com o aumento da espessura dos filtros. A dose glandular apresentou comportamento com diferentes tendências para cada caso analisado. Equações foram definidas para possibilitar a estimativa do contraste do objeto, dose glandular e tempo de exposição para os casos estudados. CONCLUSÃO: Os resultados possibilitaram a estimativa de equações que auxiliam na verificação do comportamento do contraste do objeto e da dose glandular para simuladores com espessura de 4 cm e 8 cm e para os filtros de Rh e Mo. Dessa forma, torna-se possível estimar a figura de mérito (razão entre o contraste do objeto e a dose glandular), podendo auxiliar na análise da relação risco-benefício dos casos estudados.
Resumo:
BACKGROUND: Endurance athletes are advised to optimize nutrition prior to races. Little is known about actual athletes' beliefs, knowledge and nutritional behaviour. We monitored nutritional behaviour of amateur ski-mountaineering athletes during 4 days prior to a major competition to compare it with official recommendations and with the athletes' beliefs. METHODS: Participants to the two routes of the 'Patrouille des Glaciers' were recruited (A, 26 km, ascent 1881 m, descent 2341 m, max altitude 3160 m; Z, 53 km, ascent 3994 m, descent 4090 m, max altitude 3650 m). Dietary intake diaries of 40 athletes (21 A, 19 Z) were analysed for energy, carbohydrate, fat, protein and liquid; ten were interviewed about their pre-race nutritional beliefs and behaviour. RESULTS: Despite belief that pre-race carbohydrate, energy and fluid intake should be increased, energy consumption was 2416 ± 696 (mean ± SD) kcal · day(-1), 83 ± 17 % of recommended intake, carbohydrate intake was only 46 ± 13 % of minimal recommended (10 g · kg(-1) · day(-1)) and fluid intake only 2.7 ± 1.0 l · day(-1). CONCLUSIONS: Our sample of endurance athletes did not comply with pre-race nutritional recommendations despite elementary knowledge and belief to be compliant. In these athletes a clear and reflective nutritional strategy was lacking. This suggests a potential for improving knowledge and compliance with recommendations. Alternatively, some recommendations may be unrealistic.
Resumo:
OBJETIVO: A análise crítica da metodologia de medida da camada semi-redutora em feixes de raios X teve como base o regulamento técnico para proteção radiológica e controle de qualidade em radiodiagnóstico médico e odontológico. MATERIAIS E MÉTODOS: Na medida da camada semi-redutora, a técnica radiográfica, o arranjo experimental, os meios espalhadores, a instrumentação, o tamanho de campo de radiação e a metodologia de análise dos dados foram considerados. RESULTADOS: A camada semi-redutora obtida em condições de boa geometria, para a técnica escolhida, foi de 2,44 ± 0,02 mmAl. Em relação a este valor, observaram-se desvios máximos na camada semi-redutora de 4,1% na variação da geometria, de 98,8% na variação da câmara de ionização e do meio espalhador, e de até 29,5% com outro tipo de detector. CONCLUSÃO: Os resultados mostraram que não ocorre variação significante na camada semi-redutora para diferentes tamanhos de campo de radiação, mas foram evidentes a influência do espalhamento na superestimação da camada semi-redutora e a redução desta na presença de blocos de chumbo como meio espalhador. O procedimento prático adotado mostrou-se bastante confiável e evidenciou a grande discrepância decorrente da adoção de metodologias impróprias, enfatizando a necessidade de estabelecer um procedimento padrão para a medida da camada semi-redutora.
Resumo:
We present the results of stereoscopic observations of the satellite galaxy Segue 1 with the MAGIC Telescopes, carried out between 2011 and 2013. With almost 160 hours of good-quality data, this is the deepest observational campaign on any dwarf galaxy performed so far in the very high energy range of the electromagnetic spectrum. We search this large data sample for signals of dark matter particles in the mass range between 100 GeV and 20 TeV. For this we use the full likelihood analysis method, which provides optimal sensitivity to characteristic gamma-ray spectral features, like those expected from dark matter annihilation or decay. In particular, we focus our search on gamma-rays produced from different final state Standard Model particles, annihilation with internal bremsstrahlung, monochromatic lines and box-shaped signals. Our results represent the most stringent constraints to the annihilation cross-section or decay lifetime obtained from observations of satellite galaxies, for masses above few hundred GeV. In particular, our strongest limit (95% confidence level) corresponds to a ~ 500 GeV dark matter particle annihilating into τ+τ−, and is of order langleσannvrangle simeq 1.2 × 10−24 cm3 s−1 a factor ~ 40 above the langleσannvrangle simeq thermal value.
Resumo:
Objectives: To correlate the chronic stimulated electrode position on postoperative MRI with the clinical response obtained in PD patients. Material and Method: We retrospectively reviewed 14 consecutive parkinsonian patients who were selected for STN-DBS surgery. Coordinates were determined on an IR T2 MRI coronal section per pendicular to AC-PC plane 3 mm posterior to midcommissural point (MCP) and 12 mm lateral to the midline the inferior aspect of subthalamic region. A CRW stereotactic frame was used for the surgical procedure. A 3D IR T2 MRI was performed postoperatively to determine the location of the stimulated contact in each patient. The clinical results were assessed independently by the neurological team. Results: All but 2 patients had monopolar stimulation. The mean coordinates of the stimulated contacts were: AP ^ ÿ4:23G1:4, Lat ^ 1:12G0:15, Vert ^ ÿ4:1 G2:7 to the MCP. With a mean follow-up of 8 months, all stimulated patients had a significant clinical improvement (preop/postop «ON» UPDRS: 25:8G7:0= 23:3 G8:6; preop/postop «OFF» UPDRS: 50:2G11:4=26:0 G7:8), 60% of them without any antiparkinsonian drug. Conclusion: According to the stereotactic atlas of Schaltenbrand and Warren and the 3D shape of the STN, our results show that our targetting is accurate and almost all the stimulated contacts are comprised in the STN volume. This indicates that MRI is a safe, precise and reproducible procedure for targetting the STN. The location of the stimulated contact within the STN volume is a good predictor of the clinical results.
Resumo:
Electron scattering on unstable nuclei is planned in future facilities of the GSI and RIKEN upgrades. Motivated by this fact, we study theoretical predictions for elastic electron scattering in the N=82, N=50, and N=14 isotonic chains from very proton-deficient to very proton-rich isotones. We compute the scattering observables by performing Dirac partial-wave calculations. The charge density of the nucleus is obtained with a covariant nuclear mean-field model that accounts for the low-energy electromagnetic structure of the nucleon. For the discussion of the dependence of scattering observables at low-momentum transfer on the gross properties of the charge density, we fit Helm model distributions to the self-consistent mean-field densities. We find that the changes shown by the electric charge form factor along each isotonic chain are strongly correlated with the underlying proton shell structure of the isotones. We conclude that elastic electron scattering experiments on isotones can provide valuable information about the filling order and occupation of the single-particle levels of protons.