985 resultados para safety monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The Agency for Healthcare Research and Quality (AHRQ) developed Patient Safety Indicators (PSIs) for use with ICD-9-CM data. Many countries have adopted ICD-10 for coding hospital diagnoses. We conducted this study to develop an internationally harmonized ICD-10 coding algorithm for the AHRQ PSIs. Methods: The AHRQ PSI Version 2.1 has been translated into ICD-10-AM (Australian Modification), and PSI Version 3.0a has been independently translated into ICD-10-GM (German Modification). We converted these two country-specific coding algorithms into ICD-10-WHO (World Health Organization version) and combined them to form one master list. Members of an international expert panel-including physicians, professional medical coders, disease classification specialists, health services researchers, epidemiologists, and users of the PSI-independently evaluated this master list and rated each code as either "include," "exclude," or "uncertain," following the AHRQ PSI definitions. After summarizing the independent rating results, we held a face-to-face meeting to discuss codes for which there was no unanimous consensus and newly proposed codes. A modified Delphi method was employed to generate a final ICD-10 WHO coding list. Results: Of 20 PSIs, 15 that were based mainly on diagnosis codes were selected for translation. At the meeting, panelists discussed 794 codes for which consensus had not been achieved and 2,541 additional codes that were proposed by individual panelists for consideration prior to the meeting. Three documents were generated: a PSI ICD-10-WHO version-coding list, a list of issues for consideration on certain AHRQ PSIs and ICD-9-CM codes, and a recommendation to WHO to improve specification of some disease classifications. Conclusion: An ICD-10-WHO PSI coding list has been developed and structured in a manner similar to the AHRQ manual. Although face validity of the list has been ensured through a rigorous expert panel assessment, its true validity and applicability should be assessed internationally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Petroleum hydrocarbons are common contaminants in marine and freshwater aquatic habitats, often occurring as a result of oil spillage. Rapid and reliable on-site tools for measuring the bioavailable hydrocarbon fractions, i.e., those that are most likely to cause toxic effects or are available for biodegradation, would assist in assessing potential ecological damage and following the progress of cleanup operations. Here we examined the suitability of a set of different rapid bioassays (2-3 h) using bacteria expressing the LuxAB luciferase to measure the presence of short-chain linear alkanes, monoaromatic and polyaromatic compounds, biphenyls, and DNA-damaging agents in seawater after a laboratory-scale oil spill. Five independent spills of 20 mL of NSO-1 crude oil with 2 L of seawater (North Sea or Mediterranean Sea) were carried out in 5 L glass flasks for periods of up to 10 days. Bioassays readily detected ephemeral concentrations of short-chain alkanes and BTEX (i.e., benzene, toluene, ethylbenzene, and xylenes) in the seawater within minutes to hours after the spill, increasing to a maximum of up to 80 muM within 6-24 h, after which they decreased to low or undetectable levels. The strong decrease in short-chain alkanes and BTEX may have been due to their volatilization or biodegradation, which was supported by changes in the microbial community composition. Two- and three-ring PAHs appeared in the seawater phase after 24 h with a concentration up to 1 muM naphthalene equivalents and remained above 0.5 muM for the duration of the experiment. DNA-damage-sensitive bioreporters did not produce any signal with the oil-spilled aqueous-phase samples, whereas bioassays for (hydroxy)biphenyls showed occasional responses. Chemical analysis for alkanes and PAHs in contaminated seawater samples supported the bioassay data, but did not show the typical ephemeral peaks observed with the bioassays. We conclude that bacterium-based bioassays can be a suitable alternative for rapid on-site quantitative measurement of hydrocarbons in seawater.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In the United States, the Agency for Healthcare Research and Quality (AHRQ) has developed 20 Patient Safety Indicators (PSIs) to measure the occurrence of hospital adverse events from medico-administrative data coded according to the ninth revision of the international classification of disease (ICD-9-CM). The adaptation of these PSIs to the WHO version of ICD-10 was carried out by an international consortium. METHODS: Two independent teams transcoded ICD-9-CM diagnosis codes proposed by the AHRQ into ICD-10-WHO. Using a Delphi process, experts from six countries evaluated each code independently, stating whether it was "included", "excluded" or "uncertain". During a two-day meeting, the experts then discussed the codes that had not obtained a consensus, and the additional codes proposed. RESULTS: Fifteen PSIs were adapted. Among the 2569 proposed diagnosis codes, 1775 were unanimously adopted straightaway. The 794 remaining codes and 2541 additional codes were discussed. Three documents were prepared: (1) a list of ICD-10-WHO codes for the 15 adapted PSIs; (2) recommendations to the AHRQ for the improvement of the nosological frame and the coding of PSI with ICD-9-CM; (3) recommendations to the WHO to improve ICD-10. CONCLUSIONS: This work allows international comparisons of PSIs among the countries using ICD-10. Nevertheless, these PSIs must still be evaluated further before being broadly used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To analyse prospectively the long-term results of Gamma Knife surgery (GKS) in patients with trigeminal neuralgia secondary to megadolichobasilar artery (MBA). Methods: Between December 1992 and November 2010, 33 consecutive patients presenting with ITN secondary to MBA were operated by GKS and followed prospectively in Timone University Hospital. The follow up is at least of 1 year in 29 patients. The median age was 74.90 years (range 51 to 90). The GKS typically was performed using MR and CT imaging guidance and a single 4 mm isocenter. The median of the prescription dose (at the 100%) was 90 Gy (range 80 to 90). The target was placed on the cisternal portion of the Vth nerve. Clinical and dosimetric parameters were analyzed. GKS was the first surgical procedure in 23 patients (79.31%). Results: The median follow- up period was 46.12 months (range 12.95 to 157.93). All the 29 patients (100%) were initially pain free in a median time of 13.5 days (range 0 to 240). The probability of remaining pain free at 0.5, 1, 2 years was 93.1%, 79.3% and 75.7% respectively, reaching at this time the flat part of the curve. Seven patients (24.13%) experienced a recurrence with a median delay of 10.75 months (range 3.77 to 12.62). The actuarial rate of recurrence was not higher than in our population with essential TN although atypical pain was associated with a much higher risk of recurrence (HR= 6.92, p= 0.0117). The hypoesthesia actuarial rates at 0.5 years was 4.3% and at 1 year reach 13% and remains stable till 12 years with a median delay of onset of 7 (5, 12) months. Female patients had a statistically much lower probability of developing a facial numbness (p of 0.03). No patient reported a bothersome hypoesthesia. Conclusion: Retrogaserian, high dose GKS, turned out to be very safe with only 13.04% hypoesthesia, which was never disabling (0%), while achieving high quality pain control. The majority of the patients demonstrated a prolonged effect of radiosurgery in absence of any trigeminal nerve disturbance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pre-operative assessment and surgical management of patients with non-lesional extratemporal epilepsy remain challenging due to a lack of precise localisation of the epileptic zone. In most cases, invasive recording with depth or subdural electrodes is required. Here, we describe the case of 6.5-year-old girl who underwent comprehensive non-invasive phase I video-EEG investigation for drug-resistant epilepsy, including electric source and nuclear imaging. Left operculo-insular epilepsy was diagnosed. Post-operatively, she developed aphasia which resolved within one year, corroborating the notion of enhanced language plasticity in children. The patient remained seizure-free for more than three years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Amplitude-integrated electroencephalogram (aEEG) is increasingly used for neuromonitoring in preterms. We aimed to quantify the effects of gestational age (GA), postnatal age (PNA), and other perinatal factors on the development of aEEG early after birth in very preterm newborns with normal cerebral ultrasounds.Methods:Continuous aEEG was prospectively performed in 96 newborns (mean GA: 29.5 (range: 24.4-31.9) wk, birth weight 1,260 (580-2,120) g) during the first 96 h of life. aEEG tracings were qualitatively (maturity scores) and quantitatively (amplitudes) evaluated using preestablished criteria.Results:A significant increase in all aEEG measures was observed between day 1 and day 4 and for increasing GA (P < 0.001). The effect of PNA on aEEG development was 6.4- to 11.3-fold higher than that of GA. In multivariate regression, GA and PNA were associated with increased qualitative and quantitative aEEG measures, whereas small-for-GA status was independently associated with increased maximum aEEG amplitude (P = 0.003). Morphine administration negatively affected all aEEG measures (P < .05), and caffeine administration negatively affected qualitative aEEG measures (P = 0.02).Conclusion:During the first few days after birth, aEEG activity in very preterm infants significantly develops and is strongly subjected to the effect of PNA. Perinatal factors may alter the early aEEG tracing and interfere with its interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agency Performance Plan

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Rapid diagnostic tests for malaria (RDTs) allow accurate diagnosis and prompt treatment. Validation of their usefulness in travellers with fever was needed. The safety of a strategy to diagnose falciparum malaria based on RDT followed by immediate or delayed microscopy reading at first attendance was evaluated in one referral hospital in Switzerland. METHODS: A retrospective study was conducted in the outpatient clinic and emergency ward of University Hospital, covering a period of eight years (1999-2007). The study was conducted in the outpatient clinic and emergency ward of University Hospital. All adults suspected of malaria with a diagnostic test performed were included. RDT and microscopy as immediate tests were performed during working hours, and RDT as immediate test and delayed microscopy reading out of laboratory working hours. The main outcome measure was occurrence of specific complications in RDT negative and RDT positive adults. RESULTS: 2,139 patients were recruited. 1987 had both initial RDT and blood smear (BS) result negative. Among those, 2/1987 (0.1%) developed uncomplicated malaria with both RDT and BS positive on day 1 and day 6 respectively. Among the 152 patients initially malaria positive, 137 had both RDT and BS positive, four only BS positive and five only RDT positive (PCR confirmed) (six had only one test performed). None of the four initially RDT negative/BS positive and none of the five initially BS negative/RDT positive developed severe malaria while 6/137 of both RDT and BS positive did so. The use of RDT allowed a reduction of a median of 2.1 hours to get a first malaria test result. CONCLUSIONS: A malaria diagnostic strategy based on RDTs and a delayed BS is safe in non-immune populations, and shortens the time to first malaria test result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Inotuzumab ozogamicin (CMC-544) is an antibody-targeted chemotherapy agent composed of a humanized anti-CD22 antibody conjugated to calicheamicin, a potent cytotoxic agent. This was a phase I study to determine the maximum-tolerated dose (MTD), safety, and preliminary efficacy of inotuzumab ozogamicin in an expanded MTD cohort of patients with relapsed or refractory CD22(+) B-cell non-Hodgkin's lymphoma (NHL). PATIENTS AND METHODS Inotuzumab ozogamicin was administered intravenously as a single agent once every 3 or 4 weeks at doses ranging from 0.4 to 2.4 mg/m(2). Outcomes included MTD, safety, pharmacokinetics, response, progression-free survival (PFS), and overall survival. Results Seventy-nine patients were enrolled. The MTD was determined to be 1.8 mg/m(2). Common adverse events at the MTD were thrombocytopenia (90%), asthenia (67%), and nausea and neutropenia (51% each). The objective response rate at the end of treatment was 39% for the 79 enrolled patients, 68% for all patients with follicular NHL treated at the MTD, and 15% for all patients with diffuse large B-cell lymphoma treated at the MTD. Median PFS was 317 days (approximately 10.4 months) and 49 days for patients with follicular NHL and diffuse large B-cell lymphoma, respectively. CONCLUSION Inotuzumab ozogamicin has demonstrated efficacy against CD22(+) B-cell NHL, with reversible thrombocytopenia as the main toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly newsletter for public safety

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monthly newsletter for public safety