940 resultados para rule-based


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: This study assessed in vitro the physicochemical properties of 2 methacrylate resin-based sealers (Epiphany SE and Hybrid Root SEAL), comparing the results with a well-established epoxy resin-based sealer (AH Plus). Methods: Five samples of each material were used for each test (setting time, flow, radiopacity, dimensional change after setting, and solubility) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. The samples were assigned to 3 groups: I, AH Plus; II, Epiphany SE; and III, Hybrid Root SEAL. The distilled and deionized water used at the solubility test was submitted to atomic absorption spectrometry to observe the presence of Ca2+, K+, Ni2+, and Zn2+ ions. In addition, the surface morphology of the specimens was analyzed by means of scanning electron microscopy (SEM). Statistical analysis was performed by using one-way analysis of variance and Tukey-Kramer test (P < .05). Results: Flow, radiopacity, and solubility of all sealers were in accordance with ANSI/ADA. The setting time of Hybrid Root SEAL did not agree with ANSUADA requirements. The dimensional change of all sealers was greater than the values considered acceptable by ANSI/ADA. The spectrometry analysis showed significant Ca2+ ions release for AH Plus. In SEM analysis, Hybrid Root SEAL presented spherical monomers with inferior size than AH Plus and Epiphany SE. Conclusions: It might be concluded that physicochemical properties of the tested sealers conformed to ANSI/ADA (2000) standardization, except for the setting time of Hybrid Root SEAL and the dimensional change of all sealers, which did not fulfill the ANSI/ADA requirements. (J Endod 2010;36:1531-1536)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>Aim To assess the push-out strength of Epiphany SE, Epiphany and Hybrid Root SEAL to the dentine walls of root canals. Methodology Sixty roots of canines were prepared and distributed to six groups (n = 10) according to the filling material: GI - Epiphany SE, GII - Epiphany primer and sealer, GIII - Epiphany primer, sealer and resinous solvent, GIV - Clearfil DC Bond and Epiphany sealer, GV - Clearfil, Epiphany sealer and solvent and GVI - Hybrid Root SEAL. Resilon cones were used in all groups. Roots were sectioned transversally to obtain three slices from each third. One slice was subjected to the push-out test (MPa), and results were analysed by anova and Tukey`s test (P < 0.05). The other two slices were prepared for scanning electron microscopy (SEM). Failure mode was also analysed. Results A statistically significant difference (P < 0.05) occurred between Hybrid Root SEAL (5.27 +/- 2.07) and the other materials, GI (0.40 +/- 0.23), GII (0.78 +/- 0.45), GIII (0.57 +/- 0.28), GIV (0.40 +/- 0.24) and GV (0.50 +/- 0.41), which did not differ significantly from each other (P > 0.05). Adhesive failures predominated in groups I, II, IV and V, whilst mixed and cohesive failures were the most frequent in groups III and VI, respectively. There were gaps in the adhesive interface of GI and GII, continuity areas of the filling material with dentine in GIV and GV and good adaptation of the interface of GVI. Conclusion Hybrid Root SEAL had greater push-out strength to root canal dentine than Epiphany SE and Epiphany. The use of primer, solvent and adhesive system did not influence the adhesion of Epiphany.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To compare a new root canal sealer based on Copaifera multijuga oil-resin (Biosealer) using three other established sealers (Sealer 26 (R), Endofill (R) and AH plus (R)) in terms of their physicochemical properties. Methodology The study was carried out according to the requirements of Specification Number 57 of the American Dental Association (ADA) and consisted of the following tests: setting time, flow, film thickness, dimensional stability, radiopacity and solubility/disintegration. Data were analysed statistically using anova and Tukey`s test for multiple comparisons. The significance level was set at 5% for all analyses. Results Sealer 26 (R) and AH Plus (R) had the longest setting time (P < 0.05). All materials presented flow in with the ADA`s guidelines. Regarding film thick-ness, Sealer 26 (R) did not have a satisfactory performance, as it had a higher mean value than the maximum allowed by the ADA (0.05 mm), being significantly different from the other materials (P < 0.05), which had mean values for film thickness in accordance with the ADA`s recommendations. Regarding the solubility and disintegration, only Endofill (R) did not meet the ADA`s specifications and presented the worst results of all materials (P < 0.05). Sealer 26 (R) presented the greatest dimensional changes and differed significantly from all other sealers (P < 0.05). Biosealer had the lowest radiopacity values and was significantly different from the other sealers (P < 0.05). Conclusion The experimental sealer based on Copaifera multijuga oil-resin presented satisfactory results in the physicochemical tests required by the ADA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the feasibility of an evidence-based clinical literature search service to help answer general practitioners' (GPs') clinical questions. Design: Two search services supplied GPs who submitted questions with the best available empirical evidence to answer these questions. The GPs provided feedback on the value of the service, and concordance of answers from the two search services was assessed. Setting: Two literature search services (Queensland and Victoria), operating for nine months from February 1999. Main outcome measures: Use of the service; time taken to locate answers; availability of evidence; value of the service to GPs; and consistency of answers from the two services. Results: 58 GPs asked 160 questions (29 asked one, 11 asked five or more). The questions concerned treatment (65%), aetiology (17%), prognosis (13%), and diagnosis (5%). Answering a question took a mean of 3 hours 32 minutes of personnel time (95% Cl, 2.67-3.97); nine questions took longer than 10 hours each to answer, the longest taking 23 hours 30 minutes. Evidence of suitable quality to provide a sound answer was available for 126 (79%) questions. Feedback data for 84 (53%) questions, provided by 42 GPs, showed that they appreciated the service, and asking the questions changed clinical care. There were many minor differences between the answers from the two centres, and substantial differences in the evidence found for 4/14 questions. However, conclusions reached were largely similar, with no or only minor differences for all questions. Conclusions: It is feasible to provide a literature search service, but further assessment is needed to establish its cost effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General practitioners wanting to practise evidence-based medicine (EBM) are constrained by time factors and the great diversity of clinical problems they deal with. They need experience in knowing what questions to ask, in locating and evaluating the evidence, and in applying it. Conventional searching for the best evidence can be achieved in daily general practice. Sometimes the search can be performed during the consultation, but more often it can be done later and the patient can return for the result. Case-based journal clubs provide a supportive environment for GPs to work together to find the best evidence at regular meetings. An evidence-based literature search service is being piloted to enhance decision-making for individual patients. A central facility provides the search and interprets the evidence in relation to individual cases. A request form and a results format make the service akin to pathology testing or imaging. Using EBM in general practice appears feasible. Major difficulties still exist before it can be practised by all GPs, but it has the potential to change the way doctors update their knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of a 10% carbamide peroxide-containing bleaching agent on brushing abrasion of esthetic restorative materials. Methods: Using a randomized complete block design, 150 specimens (n = 15) measuring 3 x 3 x 2 mm were fabricated into acrylic resin cylinders, using one of the restorative materials: a microfilled resin composite (At), a hybrid resin composite (Ch), a flowable resin composite (Wa), a resin-modified glass-ionomer cement (Fj) and a polyacid-modified resin composite (Dy). The bleaching agent or artificial saliva (control) was applied for 2 hours/day. After that, 120 brushing strokes were simulated automatically and the samples were kept in artificial saliva. Such bleaching/brushing cycle was performed daily for 21 days. Wear depth was assessed using profilometry. Results: Bleaching did not show significant effect on wear depth. There was a significant difference among the restorative materials. Tukey`s test showed that (Al=Ch) < (Wa) < (Fj) and that Dy was only different from Fj. (Am J Dent 2009;22:171-174).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a new periapical index based on cone beam computed tomography (CBCT) for identification of apical periodontitis (AP). The periapical index proposed in this study (CBCTPAI) was developed on the basis of criteria established from measurements corresponding to periapical radiolucency interpreted on CBCT scans. Radiolucent images suggestive of periapical lesions were measured by using the working tools of Planimp software on CBCT scans in 3 dimensions: buccopalatal, mesiodistal, and diagonal. The CBCTPAI was determined by the largest lesion extension. A 6-point (0-5) scoring system was used with 2 additional variables, expansion of cortical bone and destruction of cortical bone. A total of 1014 images (periapical radiographs and CBCT scans) originally taken from 596 patients were evaluated by 3 observers by using the CBCTPAI criteria. AP was identified in 39.5% and 60.9% of cases by radiography and CBCT, respectively (P<.01). The CBCTPAI offers an accurate diagnostic method for use with high-resolution images, which can reduce the incidence of false-negative diagnosis, minimize observer interference, and increase the reliability of epidemiologic studies, especially those referring to AP prevalence and severity. (J Endod 2008;34:1325-1331)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of pattern coating with spinel-based investment Rematitan Ultra (RU) on the castability and internal porosity of commercially pure (CP) titanium invested into phosphate-bonded investments. The apparent porosity of the investment was also measured. Materials and Methods: Square patterns (15 x 15 x 0.3 mm(3)) were either coated with RU, or not and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA), and RU (control group). The castings were made in an Ar-arc vacuum-pressure machine. The castability area (mm(2)) was measured by an image-analysis system (n = 10). For internal porosity, the casting (12 x 12 x 2 mm(3)) was studied by the X-ray method, and the projected porous area percentage was measured by an image-analysis system (n = 10). The apparent porosity of the investment (n = 10) was measured in accordance with the ASTM C373-88 standard. Results: Analysis of variance (One-way ANOVA) of castability was significant, and the Tukey test indicated that RU had the highest mean but the investing technique with coating increased the castability for all phosphate-bonded investments. The analysis of the internal porosity of the cast by the nonparametric test demonstrated that the RP, RE, and CA with coating and RP without coating did not differ from the control group (RU), while the CA and RE casts without coating were more porous. The one-way ANOVA of apparent porosity of the investment was significant, and the Tukey test showed that the means of RU (36.10%) and CA (37.22%) were higher than those of RP (25.91%) and RE (26.02%). Conclusion: Pattern coating with spinel-based material prior to phosphate-bonded investments can influence the castability and the internal porosity of CP Ti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To assess the in situ color stability, surface and the tooth/restoration interface degradation of a silorane-based composite (P90, 3M ESPE) after accelerated artificial ageing (AAA), in comparison with other dimethacrylate monomer-based composites (Z250/Z350, 3M ESPE and Esthet-X, Dentsply). Methods: Class V cavities (25 mm(2) x 2 mmdeep) were prepared in 48 bovine incisors, which were randomly allocated into 4 groups of 12 specimens each, according to the type of restorative material used. After polishing, 10 specimens were submitted to initial color readings (Easyshade, Vita) and 2 to analysis by scanning electronic microscopy (SEM). Afterwards, the teeth were submitted to AAA for 384 h, which corresponds to 1 year of clinical use, after which new color readings and microscopic images were obtained. The values obtained for the color analysis were submitted to statistical analysis (1-way ANOVA, Tukey, p < 0.05). Results: With regard to color stability, it was verified that all the composites showed color alteration above the clinically acceptable levels (Delta E >= 3.3), and that the silorane-based composite showed higher Delta E (18.6), with a statistically significant difference in comparison with the other composites (p < 0.05). The SEM images showed small alterations for the dimethacrylate-based composites after AAA and extensive degradation for the silorane-based composite with a rupture at the interface between the matrix/particle. Conclusion: It may be concluded that the silorane-based composite underwent greater alteration with regard to color stability and greater surface and tooth/restoration interface degradation after AAA. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes how watershed protection is being combined with settlement upgrading and land-use management within an area that serves as one of Greater Sao Paulo's main sources of fresh water. This is being undertaken in the municipality of San to Andre. Unlike previous watershed protection measures, which proved ineffective, it recognizes the need to combine the protection of water-sheds with the improvement of conditions in existing settlements and guiding, rather than prohibiting, further settlement. The paper describes how, the community-based watershed management involves the inhabitants of illegal settlements and other stakeholders in an adaptive planning framework that first seeks consensus on what is to be planned before developing the plan, its implementation and its operation, maintenance and monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To establish body mass index (BMI) norms for standard figural stimuli using a large Caucasian population-based sample. In addition, we sought to determine the effectiveness of the figural stimuli to identify individuals as obese or thin. DESIGN: All Caucasian twins born in Virginia between 1915 and 1971 were identified by public birth record. In addition, 3347 individual twins responded to a letter published in the newsletter of the American Association of Retired Persons (AARP). All adult twins (aged 18 and over) from both of these sources and their family members were mailed a 16 page 'Health and Lifestyle' questionnaire. SUBJECTS: BMI and silhouette data were available on 16 728 females and 11 366 males ranging in age from 18- 100. MEASUREMENTS: Self-report information on height-weight, current body size, desired body size and a discrepancy score using standard figural stimuli. RESULTS: Gender- and age-specific norms are presented linking BMI to each of the figural stimuli. Additional norms for desired body size and discrepancy scores are also presented. Receiver operating curves (ROC) indicate that the figural stimuli are effective in classifying individuals as obese or thin. CONCLUSIONS: With the establishment of these norms, the silhouettes used in standard body image assessment can now be linked to BMI. Differences were observed between women and men in terms of desired body size and discrepancy scores, with women preferring smaller sizes. The figural stimuli are a robust technique for classifying individuals as obese or thin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new wavelet-based method for solving population balance equations with simultaneous nucleation, growth and agglomeration is proposed, which uses wavelets to express the functions. The technique is very general, powerful and overcomes the crucial problems of numerical diffusion and stability that often characterize previous techniques in this area. It is also applicable to an arbitrary grid to control resolution and computational efficiency. The proposed technique has been tested for pure agglomeration, simultaneous nucleation and growth, and simultaneous growth and agglomeration. In all cases, the predicted and analytical particle size distributions are in excellent agreement. The presence of moving sharp fronts can be addressed without the prior investigation of the characteristics of the processes. (C) 2001 Published by Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.