979 resultados para repair resin composite
Resumo:
A study of vibrations of multifiber composite shells is presented. Special attention is paid to the effect of composition of different fibers on the frequency spectrum of a freely vibrating cylindrical shell. The numerical results indicate clustering of frequency spectrum of a freely vibrating cylindrical composite shell as compared with the isotropic shell, and the spectrum varies considerably with the composition of the constituent materials.
Resumo:
Abstrat is not available.
Resumo:
Conventional analytical/numerical methods employing triangulation technique are suitable for locating acoustic emission (AE) source in a planar structure without structural discontinuities. But these methods cannot be extended to structures with complicated geometry, and, also, the problem gets compounded if the material of the structure is anisotropic warranting complex analytical velocity models. A geodesic approach using Voronoi construction is proposed in this work to locate the AE source in a composite structure. The approach is based on the fact that the wave takes minimum energy path to travel from the source to any other point in the connected domain. The geodesics are computed on the meshed surface of the structure using graph theory based on Dijkstra's algorithm. By propagating the waves in reverse virtually from these sensors along the geodesic path and by locating the first intersection point of these waves, one can get the AE source location. In this work, the geodesic approach is shown more suitable for a practicable source location solution in a composite structure with arbitrary surface containing finite discontinuities. Experiments have been conducted on composite plate specimens of simple and complex geometry to validate this method.
Resumo:
Organic-inorganic composite membranes comprising Nation with inorganic materials such as silica, mesoporous zirconium phosphate (MZP) and mesoporous titanium phosphate (MTP) are fabricated and evaluated as proton-exchange-membrane electrolytes for direct methanol fuel cells (DMFCs). For Nation-silica composite membrane, silica is impregnated into Nation matrix as a sol by a novel water hydrolysis process precluding the external use of an acid. Instead, the acidic nature of Nation facilitates in situ polymerization reaction with Nation leading to a uniform composite membrane. The rapid hydrolysis and polymerization reaction while preparing zirconia and titania sols leads to uncontrolled thickness and volume reduction in the composite membranes, and hence is not conducive for casting membranes. Nafion-MZP and Nafion-MTP composite membranes are prepared by mixing pre-formed porous MZP and MTP with Nation matrix. MZP and MTP are synthesised by co-assembly of a tri-block co-polymer, namely pluronic-F127, as a structure-directing agent, and a mixture of zirconium butoxide/titanium isopropoxide and phosphorous trichloride as inorganic precursors. Methanol release kinetics is studied by volume-localized NMR spectroscopy (employing ``point resolved spectroscopy'', PRESS), the results clearly demonstrating that the incorporation of inorganic fillers in Nation retards the methanol release kinetics under osmotic drag. Appreciable proton conductivity with reduced methanol permeability across the composite membranes leads to improved performance of DMFCs in relation to commercially available Nafion-117 membrane.
Resumo:
Mismatch repair (MMR) mechanisms repair DNA damage occurring during replication and recombination. To date, five human MMR genes, MSH2, MHS6, MSH3, MLH1 and PMS2 are known to be involved in the MMR function. Human MMR proteins form 3 different heterodimers: MutSα (MSH2 and MSH6) and MutSβ (MSH2 and MSH3), which are needed for mismatch recognition and binding, and MutLα (MLH1 and PMS2), which is needed for mediating interactions between MutS homologues and other MMR proteins. The other two MutL homologues, MLH3 and PMS1, have been shown to heterodimerize with MLH1. However, the heterodimers MutLγ (MLH1and MLH3) and MutLβ (MLH1 and PMS1) are able to correct mismatches only with low or no efficiency, respectively. A deficient MMR mechanism is associated with the hereditary colorectal cancer syndrome called hereditary nonpolyposis colorectal cancer (HNPCC) or Lynch syndrome. HNPCC is the most common hereditary colorectal cancer syndrome and accounts for 2-5% of all colorectal cancer cases. HNPCC-associated mutations have been found in 5 MMR genes: MLH1, MSH2, MSH6, PMS2 and MLH3. Most of the mutations have been found in MLH1 and MSH2 (~90%) and are associated with typical HNPCC, while mutations in MSH6, PMS2 and MLH3 are mainly linked to putative HNPCC families lacking the characteristics of the syndrome. More data of MLH3 mutations are needed to assess the significance of its mutations in HNPCC. In this study, were functionally characterized 51 nontruncating mutations in the MLH1, MLH3 and MSH2 genes to address their pathogenic significance and mechanism of pathogenicity. Of the 36 MLH1 mutations, 22 were deficient in more than one assay, 2 variants were impaired only in one assay, and 12 variants behaved like the wild type protein, whereas all seven MLH3 mutants functioned like the wild type protein in the assays. To further clarify the role and relevance of MLH3 in MMR, we analyzed the subcellular localization of the native MutL homologue proteins. Our immunofluorescence analyses indicated that when all the three MutL homologues are natively expressed in human cells, endogenous MLH1 and PMS2 localize in the nucleus, whereas MLH3 stays in the cytoplasm. The coexpression of MLH3 with MLH1 results in its partial nuclear localization. Only one MSH2 mutation was pathogenic in the in vitro MMR assay. Our study on MLH1 mutations could clearly distinguish nontruncating alterations with severe functional defects from those not or only slightly impaired in protein function. However, our study on MLH3 mutations suggest that MLH3 mutations per se are not sufficient to trigger MMR deficiency and the continuous nuclear localization of MLH1 and PMS2 suggest that MutLα has a major activity in MMR in vivo. Together with our functional assays, this confirms that MutLγ is a less efficient MMR complex than MutLα.
Resumo:
O6-Alkylguanine-DNA alkyltransferase (AGT) repairs O6-methylguanine (O6mG) in DNA that is known to cause Mutation and cancer. On the basis of Calculations performed using density functional theory involving the active site of AGT, a mechanism for catalytic demethylation of O6mG to guanine has been proposed. In this mechanism, roles of six amino acids, i.e., Cys145, His 146, Glu172, Tyr114, Lys165, and Ser159 in catalytic demethylation of O6mG are involved. This mechanism has three steps as follows. At the first step, Cys145 in the Cys145-water-His146-Glu172 tetrad is converted to cysteine thiolate anion while at the second step, abstraction of the Tyr114 proton by the N3 site of O6mG occurs in a barrierless manner. In the third step, abstraction of Lys165 proton by deprotonated Tyr114 and transfer of the methyl group of O6mG to the thiolate group of Cys145 anion Occur simultaneously. As AGT is a major target in cancer therapy, identification of the roles of the different amino acids in demethylation of O6mG is expected to be useful in designing efficient AGT inhibitors.
Resumo:
An "atomic layer-by-layer" structure of Co3O4/graphene is developed as an anode material for lithium-ion batteries. Due to the atomic thickness of both the Co3O4 nanosheets and the graphene, the composite exhibits an ultrahigh specific capacity of 1134.4 mAh g-1 and an ultralong life up to 2000 cycles at 2.25 C, far beyond the performances of previously reported Co3O4/C composites.
Resumo:
This article analyzes the effect of devising a new failure envelope by the combination of the most commonly used failure criteria for the composite laminates, on the design of composite structures. The failure criteria considered for the study are maximum stress and Tsai-Wu criteria. In addition to these popular phenomenological-based failure criteria, a micromechanics-based failure criterion called failure mechanism-based failure criterion is also considered. The failure envelopes obtained by these failure criteria are superimposed over one another and a new failure envelope is constructed based on the lowest absolute values of the strengths predicted by these failure criteria. Thus, the new failure envelope so obtained is named as most conservative failure envelope. A minimum weight design of composite laminates is performed using genetic algorithms. In addition to this, the effect of stacking sequence on the minimum weight of the laminate is also studied. Results are compared for the different failure envelopes and the conservative design is evaluated, with respect to the designs obtained by using only one failure criteria. The design approach is recommended for structures where composites are the key load-carrying members such as helicopter rotor blades.
Resumo:
The purpose of this series of studies was to evaluate the biocompatibility of poly (ortho) ester (POE), copolymer of ε-caprolactone and D,L-lactide [P (ε-CL/DL-LA)] and the composite of P(ε-CL/DL-LA) and tricalciumphosphate (TCP) as bone filling material in bone defects. Tissue reactions and resorption times of two solid POE-implants (POE 140 and POE 46) with different methods of sterilization (gamma- and ethylene oxide sterilization), P(ε-CL/DL-LA)(40/60 w/w) in paste form and 50/50 w/w composite of 40/60 w/w P(ε-CL/DL-LA) and TCP and 27/73 w/w composite of 60/40 w/w P(ε-CL/DL-LA) and TCP were examined in experimental animals. The follow-up times were from one week to 52 weeks. The bone samples were evaluated histologically and the soft tissue samples histologically, immunohistochemically and electronmicroscopically. The results showed that the resorption time of gamma sterilized POE 140 was eight weeks and ethylene oxide sterilized POE 140 13 weeks in bone. The resorption time of POE 46 was more than 24 weeks. The gamma sterilized rods started to erode from the surface faster than ethylene oxide sterilized rods for both POEs. Inflammation in bone was from slight to moderate with POE 140 and moderate with POE 46. No highly fluorescent layer of tenascin or fibronectin was found in the soft tissue. Bone healing at the sites of implantation was slower than at control sites with the copolymer in small bone defects. The resorption time for the copolymer was over one year. Inflammation in bone was mostly moderate. Bone healing at the sites of implantation was also slower than at the control sites with the composite in small and large mandibular bone defects. Bone formation had ceased at both sites by the end of follow-up in large mandibular bone defects. The ultrastructure of the connective tissue was normal during the period of observation. It can be concluded that the method of sterilization influenced the resorption time of both POEs. Gamma sterilized POE 140 could have been suitable material for filling small bone defects, whereas the degradation times of solid EO-sterilized POE 140 and POE 46 were too slow to be considered as bone filling material. Solid material is difficult to contour, which can be considered as a disadvantage. The composites were excellent to handle, but the degradation time of the polymer and the composites were too slow. Therefore, the copolymer and the composite can not be recommended as bone filling material.
Resumo:
Paper-like free-standing germanium (Ge) and single-walled carbon nanotube (SWCNT) composite anodes were synthesized by the vacuum filtration of Ge/SWCNT composites, which were prepared by a facile aqueous-based method. The samples were characterized by X-ray diffraction, field emission scanning electron microscopy, and transmission electron microscopy. Electrochemical measurements demonstrate that the Ge/SWCNT composite paper anode with the weight percentage of 32% Ge delivered a specific discharge capacity of 417 mA h g-1 after 40 cycles at a current density of 25 mA g-1, 117% higher than the pure SWCNT paper anode. The SWCNTs not only function as a flexible mechanical support for strain release, but also provide excellent electrically conducting channels, while the nanosized Ge particles contribute to improving the discharge capacity of the paper anode.
Resumo:
Lead germanate-graphene nanosheets (PbGeO3-GNS) composites have been prepared by an efficient one-step, in-situ hydrothermal method and were used as anode materials for Li-ion batteries (LIBs). The PbGeO3 nanowires, around 100–200 nm in diameter, are highly encapsulated in a graphene matrix. The lithiation and de-lithiation reaction mechanisms of the PbGeO3 anode during the charge-discharge processes have been investigated by X-ray diffraction and electrochemical characterization. Compared with pure PbGeO3 anode, dramatic improvements in the electrochemical performance of the composite anodes have been obtained. In the voltage window of 0.01–1.50 V, the composite anode with 20 wt.% GNS delivers a discharge capacity of 607 mAh g−1 at 100 mA g−1 after 50 cycles. Even at a high current density of 1600 mA g−1, a capacity of 406 mAh g−1 can be achieved. Therefore, the PbGeO3-GNS composite can be considered as a potential anode material for lithium ion batteries.