831 resultados para quality index of the square


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND AIMS Inflammatory bowel disease (IBD) frequently manifests during childhood and adolescence. For providing and understanding a comprehensive picture of a patients' health status, health-related quality of life (HRQoL) instruments are an essential complement to clinical symptoms and functional limitations. Currently, the IMPACT-III questionnaire is one of the most frequently used disease-specific HRQoL instrument among patients with IBD. However, there is a lack of studies examining the validation and reliability of this instrument. METHODS 146 paediatric IBD patients from the multicenter Swiss IBD paediatric cohort study database were included in the study. Medical and laboratory data were extracted from the hospital records. HRQoL data were assessed by means of standardized questionnaires filled out by the patients in a face-to-face interview. RESULTS The original six IMPACT-III domain scales could not be replicated in the current sample. A principal component analysis with the extraction of four factor scores revealed the most robust solution. The four factors indicated good internal reliability (Cronbach's alpha=.64-.86), good concurrent validity measured by correlations with the generic KIDSCREEN-27 scales and excellent discriminant validity for the dimension of physical functioning measured by HRQoL differences for active and inactive severity groups (p<.001, d=1.04). CONCLUSIONS This study with Swiss children with IBD indicates good validity and reliability for the IMPACT-III questionnaire. However, our findings suggest a slightly different factor structure than originally proposed. The IMPACT-III questionnaire can be recommended for its use in clinical practice. The factor structure should be further examined in other samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The SWISSspine registry (SSR) was launched in 2005 to assess the safety and effectiveness of balloon kyphoplasty (BKP). In the meantime, repeated reports on high rates of adjacent vertebral fractures (ASF) after BKP of vertebral insufficiency fractures were published. The causes for ASF and their risk factors are still under debate. The purpose of this study was to report the incidence and potential risk factors of ASF within the SSR dataset. METHODS The SSR data points are collected perioperatively and during follow-ups, with surgeon- and patient-based information. All patients documented with a monosegmental osteoporotic vertebral insufficiency fracture between March 2005 and May 2012 were included in the study. The incidence of ASF, significant associations with co-variates (patient age, gender, fracture location, cement volume, preoperative segmental kyphosis, extent of kyphosis correction, and individual co-morbidities) and influence on quality of life (EQ-5D) and back pain (VAS) were analyzed. RESULTS A total of 375 patients with a mean follow-up of 3.6 months was included. ASF were found in 9.9 % (n = 37) and occurred on average 2.8 months postoperatively. Preoperative segmental kyphosis >30° (p = 0.026), and rheumatoid arthritis (p = 0.038) and cardiovascular disease (p = 0.047) were significantly associated with ASF. Furthermore, patients with ASF had significantly higher back pain at the final follow-up (p = 0.001). No further significant associations between the studied co-variates and ASF were seen in the adjusted analysis. CONCLUSIONS The findings suggest that patients with a preoperative segmental kyphosis >30° or patients with co-morbidities like rheumatoid arthritis and a cardiovascular disease are at high risk of ASF within 6 months after the index surgery. In case of an ASF event, back pain levels are significantly increased. LEVEL OF EVIDENCE IV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In recent years, the WHO Wellbeing Index (WHO-5) has been used as a screening measure for depression. Nevertheless, research on the validity of this measure in the context of clinical depression is sparse. QUESTIONS: The aim of the present study was to investigate the measurement invariance of the WHO-5 across depressed and non-depressed individuals, as well as the shape and specificity of its relationship to measures of depression severity. METHOD: Of the 414 subjects who completed the WHO-5 and the Beck Depression Inventory-II (BDI-II), 207 had a diagnosis of a major depressive episode (MDE). A subsample also completed the Beck Anxiety Inventory (BAI) and was assessed by clinicians using the Hamilton Depression Rating Scale (HAM-D) and the Hamilton Anxiety Rating Scale (HAM-A). RESULTS: The WHO-5 demonstrated strong measurement invariance regarding the presence or absence of a current MDE. The WHO-5 showed a very high negative association with self- and observer-rated measures of depressive symptoms, especially in the range of mild to moderate symptoms. These associations were still substantial after controlling for measures of anxiety symptoms. LIMITATIONS: In addition to a diagnostic interview, only one measure for self- and observer-rated symptoms of depression was used. Furthermore, the observer-rated measure was only assessed in one subsample that exhibited a somewhat restricted range of depression severity. CONCLUSION: Although this index was originally designed as a measure of well-being, the results support the use of the WHO-5 in the context of depression research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Multi-GNSS Experiment (MGEX) of the International GNSS Service (IGS) aims at the data collection and analysis of all available satellite navigation systems. In particular the new global and regional satellite navigation systems are of interest, i.e., the European Galileo, the Chinese BeiDou, the Japanese QZSS as well as satellite based augmentation systems. This article analyzes the orbit and clock quality of the Galileo products of four MGEX analysis centers for a common time period of 20 weeks. Orbit comparisons of the individual analysis centers have a consistency at the 5–30 cm level. Day boundary discontinuities range from 4 to 28 cm whereas 2-day orbit fit RMS values vary between 1 and 7 cm. The accuracy evaluated by satellite laser ranging residuals is on the one decimeter level with a systematic bias of about −5 cm for all analysis centers. In addition, systematic errors on the decimeter level related to solar radiation pressure mismodeling are present in all orbit products. Due to the correlation of radial orbit errors with the clock parameters, these errors are also visible as a bump in the Allan deviation of the Galileo satellite clocks at the orbital frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The Pulmonary Embolism Quality of Life questionnaire (PEmb-QoL) is a 40-item questionnaire to measure health-related quality of life in patients with pulmonary embolism. It covers six 6 dimensions: frequency of complaints, limitations in activities of daily living, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we prospectively validated a German version of the PEmb-QoL. METHODS A forward-backward translation of the English version of the PEmb-QoL into German was performed. German-speaking consecutive adult patients aged ≥18 years with an acute, objectively confirmed pulmonary embolism discharged from a Swiss university hospital (01/2011-06/2013) were recruited telephonically. Established psychometric tests and criteria were used to evaluate the acceptability, reliability, and validity of the German PEmb-QoL questionnaire. To assess the underlying dimensions, an exploratory factor analysis was performed. RESULTS Overall, 102 patients were enrolled in the study. The German version of the PEmb-QoL showed a good internal consistency (Cronbach's alpha ranging from 0.72 to 0.96), item-total (0.53-0.95) and inter-item correlations (>0.4), and test-retest reliability (intra-class correlation coefficients 0.59-0.89) for the dimension scores. A moderate correlation of the PEmb-QoL with SF-36 dimension and summary scores (0.21-0.83) indicated convergent validity, while low correlations of PEmb-QoL dimensions with clinical characteristics (-0.16-0.37) supported discriminant validity. The exploratory factor analysis suggested four underlying dimensions: limitations in daily activities, symptoms, work-related problems, and emotional complaints. CONCLUSION The German version of the PEmb-QoL questionnaire is a valid and reliable disease-specific measure for quality of life in patients with pulmonary embolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the long term oncological and functional outcomes after readaptation of the dorsolateral peritoneal layer following pelvic lymph node dissection (PLND) and cystectomy . PATIENTS AND METHODS A randomised, single-center, single-blinded, two-arm trial was conducted on 200 consecutive cystectomy patients who underwent PLND and cystectomy for bladder cancer (of the dorsolateral peritoneal layer (n=100; 73 male, 27 female; median age 68 yrs, range 35-86 yrs) and group B without readapation (n=100; 66 male, 34 female; median age 65 yrs, range 30-86 yrs). Regular postoperative follow-up was performed at our outpatient clinic. Median follow-up was 59 months (range 3-100 months), five patients were lost to follow-up in group A, seven in group B. Bowel function was evaluated using the validated Gastrointestinal Quality of Life Index questionnaire and an institutional questionnaire regarding post-cystectomy outcome. Local recurrences and distal metastases were evaluated using computed tomography and bone scan at the regular follow-up visits. RESULTS There was no significant difference between the two groups in terms of the rate of local (pelvic) recurrence (5/95 [5.3%] in group A; 7/93 [7.5%] in group B; p = 0.53), the rate of distant metastases (21/95 [22.1%] in group A; 23/93 [24.7%] in group B; p = 0.67), cancer-specific survival (p = 0.37), and overall survival (p = 0.59). Group A had significantly better bowel function at 3 (p < 0.001), 6 (p < 0.006), 12 (p <0.006) and 24 months (p = 0.04), and significantly less postoperative abdominal pain and bloating at 3 (p = 0.002) and 6 months (p = 0.01). CONCLUSION Readaptation of the dorsolateral peritoneal layer following PLND and cystectomy has a beneficial long-term impact on bowel function and postoperative pain without compromising oncological radicality. This article is protected by copyright. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Patients with biochemical failure (BF) after radical prostatectomy may benefit from dose-intensified salvage radiation therapy (SRT) of the prostate bed. We performed a randomized phase III trial assessing dose intensification. PATIENTS AND METHODS Patients with BF but without evidence of macroscopic disease were randomly assigned to either 64 or 70 Gy. Three-dimensional conformal radiation therapy or intensity-modulated radiation therapy/rotational techniques were used. The primary end point was freedom from BF. Secondary end points were acute toxicity according to the National Cancer Institute Common Terminology Criteria for Adverse Events (version 4.0) and quality of life (QoL) according to the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaires C30 and PR25. RESULTS Three hundred fifty patients were enrolled between February 2011 and April 2014. Three patients withdrew informed consent, and three patients were not eligible, resulting in 344 patients age 48 to 75 years in the safety population. Thirty patients (8.7%) had grade 2 and two patients (0.6%) had grade 3 genitourinary (GU) baseline symptoms. Acute grade 2 and 3 GU toxicity was observed in 22 patients (13.0%) and one patient (0.6%), respectively, with 64 Gy and in 29 patients (16.6%) and three patients (1.7%), respectively, with 70 Gy (P = .2). Baseline grade 2 GI toxicity was observed in one patient (0.6%). Acute grade 2 and 3 GI toxicity was observed in 27 patients (16.0%) and one patient (0.6%), respectively, with 64 Gy, and in 27 patients (15.4%) and four patients (2.3%), respectively, with 70 Gy (P = .8). Changes in early QoL were minor. Patients receiving 70 Gy reported a more pronounced and clinically relevant worsening in urinary symptoms (mean difference in change score between arms, 3.6; P = .02). CONCLUSION Dose-intensified SRT was associated with low rates of acute grade 2 and 3 GU and GI toxicity. The impact of dose-intensified SRT on QoL was minor, except for a significantly greater worsening in urinary symptoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate detection of individuals at clinical high risk (CHR) for psychosis is a prerequisite for effective preventive interventions. Several psychometric interviews are available, but their prognostic accuracy is unknown. We conducted a prognostic accuracy meta-analysis of psychometric interviews used to examine referrals to high risk services. The index test was an established CHR psychometric instrument used to identify subjects with and without CHR (CHR+ and CHR-). The reference index was psychosis onset over time in both CHR+ and CHR- subjects. Data were analyzed with MIDAS (STATA13). Area under the curve (AUC), summary receiver operating characteristic curves, quality assessment, likelihood ratios, Fagan's nomogram and probability modified plots were computed. Eleven independent studies were included, with a total of 2,519 help-seeking, predominately adult subjects (CHR+: N=1,359; CHR-: N=1,160) referred to high risk services. The mean follow-up duration was 38 months. The AUC was excellent (0.90; 95% CI: 0.87-0.93), and comparable to other tests in preventive medicine, suggesting clinical utility in subjects referred to high risk services. Meta-regression analyses revealed an effect for exposure to antipsychotics and no effects for type of instrument, age, gender, follow-up time, sample size, quality assessment, proportion of CHR+ subjects in the total sample. Fagan's nomogram indicated a low positive predictive value (5.74%) in the general non-help-seeking population. Albeit the clear need to further improve prediction of psychosis, these findings support the use of psychometric prognostic interviews for CHR as clinical tools for an indicated prevention in subjects seeking help at high risk services worldwide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Members of the Mycoplasma mycoides cluster' represent important livestock pathogens worldwide. Mycoplasma mycoides subsp. mycoides is the etiologic agent of contagious bovine pleuropneumonia (CBPP), which is still endemic in many parts of Africa. We report the genome sequences and annotation of two frequently used challenge strains of Mycoplasma mycoides subsp. mycoides, Afadé and B237. The information provided will enable downstream 'omics' applications such as proteomics, transcriptomics and reverse vaccinology approaches. Despite the absence of Mycoplasma pneumoniae like cyto-adhesion encoding genes, the two strains showed the presence of protrusions. This phenotype is likely encoded by another set of genes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION If a surgical approach is chosen to treat a multirooted tooth affected by persistent periapical pathosis, usually only the affected roots are operated on. The present study assessed the periapical status of the nonoperated root 5 years after apical surgery of the other root in mandibular molars. METHODS Patients treated with apical surgery of mandibular molars with a follow-up of 5 years were selected. Patient-related and clinical parameters (sex, age, smoking, symptoms, and signs of infection) before surgery were recorded. Preoperative intraoral periapical radiographs and radiographs 5 years after surgery were examined. The following data were collected: tooth, operated root, type and quality of the coronal restoration, marginal bone level, length and homogeneity of the root canal filling, presence of a post/screw, periapical index (PAI) of each root, and radiographic healing of the operated root. The presence of apical pathosis of the nonoperated root was analyzed statistically in relation to the recorded variables. RESULTS Thirty-seven patients fulfilled the inclusion criteria. Signs of periapical pathosis in the nonoperated root 5 years after surgery (PAI ≥ 3) could be observed in only 3 cases (8.1%). Therefore, statistical analysis in relation to the variables was not possible. The PAI of the nonoperated root before surgery had a weak correlation with signs of apical pathosis 5 years after surgery. CONCLUSIONS Nonoperated roots rarely developed signs of new apical pathosis 5 years after apical surgery of the other root in mandibular molars. It appears reasonable to resect and fill only roots with a radiographically evident periapical lesion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The main objective was to assess the credibility of the evidence using Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) in oral health systematic reviews on the Cochrane Database of Systematic Reviews (CDSR) and elsewhere. STUDY DESIGN AND SETTING Systematic Reviews or meta-analyses (January 2008-December 2013) from 14 high impact general dental and specialty dental journals and the Cochrane Database of Systematic Reviews were screened for meta-analyses. Data was collected at the systematic review, meta-analysis and trial level. Two reviewers applied and agreed on the GRADE rating for the selected meta-analyses. RESULTS From the 510 systematic reviews initially identified 91 reviews (41 Cochrane and 50 non-Cochrane) were eligible for inclusion. The quality of evidence was high in 2% and moderate in 18% of the included meta-analyses with no difference between Cochrane and non-Cochrane reviews, journal impact factor or year of publication. The most common domains prompting downgrading of the evidence were study limitations (risk of bias) and imprecision (risk of play of chance). CONCLUSION The quality of the evidence in oral health assessed using GRADE is predominantly low or very low suggesting a pressing need for more randomised clinical trials and other studies of higher quality in order to inform clinical decisions thereby reducing the risk of instituting potentially ineffective and/or harmful therapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To investigate if image registration of diffusion tensor imaging (DTI) allows omitting respiratory triggering for both transplanted and native kidneys MATERIALS AND METHODS: Nine kidney transplant recipients and eight healthy volunteers underwent renal DTI on a 3T scanner with and without respiratory triggering. DTI images were registered using a multimodal nonrigid registration algorithm. Apparent diffusion coefficient (ADC), the contribution of perfusion (FP ), and the fractional anisotropy (FA) were determined. Relative root mean square errors (RMSE) of the fitting and the standard deviations of the derived parameters within the regions of interest (SDROI ) were evaluated as quality criteria. RESULTS Registration significantly reduced RMSE in all DTI-derived parameters of triggered and nontriggered measurements in cortex and medulla of both transplanted and native kidneys (P < 0.05 for all). In addition, SDROI values were lower with registration for all 16 parameters in transplanted kidneys (14 of 16 SDROI values were significantly reduced, P < 0.04) and for 15 of 16 parameters in native kidneys (9 of 16 SDROI values were significantly reduced, P < 0.05). Comparing triggered versus nontriggered DTI in transplanted kidneys revealed no significant difference for RMSE (P > 0.14) and for SDROI (P > 0.13) of all parameters. In contrast, in native kidneys relative RMSE from triggered scans were significantly lower than those from nontriggered scans (P < 0.02), while SDROI was slightly higher in triggered compared to nontriggered measurements in 15 out of 16 comparisons (significantly for two, P < 0.05). CONCLUSION Registration improves the quality of DTI in native and transplanted kidneys. Diffusion parameters in renal allografts can be measured without respiratory triggering. In native kidneys, respiratory triggering appears advantageous. J. Magn. Reson. Imaging 2016.