984 resultados para pre-planning


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is increasing evidence that modular neck stems are prone to corrosion-related complications. Recent studies showed elevated metal ions levels and occasional pseudotumor formation in patients with such implants. The purpose of this study was to compare systemic metal-ion levels in patients after primary THA with modular neck stems to those of patients after non-modular implants. To our knowledge, this is the first cohort study including a control group, THA without CoCr heads and dry-assembled neck-stem connections. Methods: 50 patients after THA at a minimum follow-up of 1 year have been selected for the study. Patients with multiple prosthesis or other implants have been deselected. All received a cementless SPS stem from Symbios (Ti6Al4V). 40 patients have the modular neck (CoCr) version and 10 a monobloc version. All bearings were either ceramic-ceramic or ceramic-polyethylene to minimize other sources of CoCr ion release. In the modular group, the neck was chosen pre-operatively based on a 3D planning, allowing for a dry assembly of the stem and neck on the back table before implantation. A plasma system coupled to mass spectrometry was used for a complete elementary quantification in blood and serum separately. Clinical outcome was measured using the Oxford Hip Score. Results : Complete data sets of 29 patients (24 in the modular neck-group (10male, mean age 63y, 35-84y) and 5 in the monobloc-group (3 male, 69 y, 51-83y) are available to date. Mean Co blood levels were .95 ug/L (.14-12.4) in the modular group vs .27 ug/L (.10-.73) in the monobloc group (p=.2). Respective values for Cr were significantly higher in the modular group (.99 g/L; range .75-1.21) compared to those in the monobloc group (.74 g/L ;.62-.86; p=.001). No significant difference was found when comparing serum levels. 5/24 patients had Co levels above 1 g/L (12/24 for Cr), which is by some considered as a relevant elevation. The maximum Co level was measured in an asymptomatic patient. The Oxford Hip Scores were similar in both groups. Conclusion: Cr levels were significantly elevated in the modular neck group compared to those in the monobloc group. 1/24 patients with a modular prosthesis exhibited Co levels, which are beyond the threshold accepted even for metal-on-metal bearing couples. These results have contributed to our decision to abandon the use of modular neck stems. Routine follow-up including annual measurements of systemic CoCr concentrations should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Transportation Facilities Manual provides a system of identifying and coding existing streets and highways and of recording data pertaining to these facilities. This manual is part 1 and together with the other two documents may be used in connection with the preparation of comprehensive and special planning an urban research studies of all kinds. Particular emphasis was placed on the updating of collected information so that basic inventories pertaining to the planning process can be kept current without undue effort or cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BackgroundAll patients should be fully informed about the risks and benefits of anaesthetic procedures before giving a written consent. Moreover, the satisfaction level may vary in proportion to the information given. We aimed to determine, in a single-blind randomized-controlled study, whether an information form given before the pre-anaesthetic consultation could improve perceived information, information gain and satisfaction level.MethodsTwo hundred patients ASA 1-3 scheduled for an elective orthopaedic surgery were randomized into two groups: a group that received an information form before the pre-anaesthetic consultation (IF group) and a control group (no information form). A standardized questionnaire was submitted after the pre-anaesthetic consultation and after the operation. This 17-item questionnaire explored perceived information (five items), information gain (three items) and satisfaction level (nine items). The items of each topic were pooled and compared between groups.ResultsOne hundred and eighty-five patients (92.5%) completed the study. The IF group had better perceived information (IF group 73% vs. control group 63%, P=0.002), higher information gain (IF group 75% vs. control group 62%, P=0.001) and a higher satisfaction level (IF group 95% vs. control group 92%, P=0.048).ConclusionsOur study suggests that an information form given before the pre-anaesthetic consultation enhances perceived information, information gain and satisfaction level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies have associated activating Killer cell Immunoglobulin-like Receptor (KIR) genes with protection from cytomegalovirus (CMV) replication after organ transplantation. Whether KIR-associated protection is operating in the context of primary infection, re-activation, or both, remains unknown. Here we correlated KIR genotype and CMV serostatus at the time of transplantation with rates of CMV viremia in 517 heart (n=57), kidney (n=223), liver (n=165) or lung (n=72) allograft recipients reported to the Swiss Transplant Cohort Study. Across the entire cohort we found B haplotypes-which in contrast to A haplotypes may contain multiple activating KIR genes-to be protective in the most immunosuppressed patients (receiving anti-thymocyte globulin induction and intensive maintenance immunosuppression) (hazard ratio after adjustment for covariates 0.46, 95% confidence interval 0.29-0.75, P=0.002). Notably, a significant protection was detected only in recipients who were CMV-seropositive at the time of transplantation (HR 0.45, 95% CI 0.26-0.77, P=0.004), but not in CMV seronegative recipients (HR 0.59, 95% CI 0.22-1.53, P=0.28). These data indicate a prominent role for KIR-and presumably natural killer (NK) cells-in the control of CMV replication in CMV seropositive organ transplant recipients treated with intense immunosuppression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Effective cancer treatment generally requires combination therapy. The combination of external beam therapy (XRT) with radiopharmaceutical therapy (RPT) requires accurate three-dimensional dose calculations to avoid toxicity and evaluate efficacy. We have developed and tested a treatment planning method, using the patient-specific three-dimensional dosimetry package 3D-RD, for sequentially combined RPT/XRT therapy designed to limit toxicity to organs at risk. METHODS AND MATERIALS: The biologic effective dose (BED) was used to translate voxelized RPT absorbed dose (D(RPT)) values into a normalized total dose (or equivalent 2-Gy-fraction XRT absorbed dose), NTD(RPT) map. The BED was calculated numerically using an algorithmic approach, which enabled a more accurate calculation of BED and NTD(RPT). A treatment plan from the combined Samarium-153 and external beam was designed that would deliver a tumoricidal dose while delivering no more than 50 Gy of NTD(sum) to the spinal cord of a patient with a paraspinal tumor. RESULTS: The average voxel NTD(RPT) to tumor from RPT was 22.6 Gy (range, 1-85 Gy); the maximum spinal cord voxel NTD(RPT) from RPT was 6.8 Gy. The combined therapy NTD(sum) to tumor was 71.5 Gy (range, 40-135 Gy) for a maximum voxel spinal cord NTD(sum) equal to the maximum tolerated dose of 50 Gy. CONCLUSIONS: A method that enables real-time treatment planning of combined RPT-XRT has been developed. By implementing a more generalized conversion between the dose values from the two modalities and an activity-based treatment of partial volume effects, the reliability of combination therapy treatment planning has been expanded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Department of Transportation (Iowa DOT) Special Events Planning (SEP) document is a collection of Special Event Management Strategic Plans for individual events throughout the state of Iowa. The development of the SEP document focused on improving travel, safety and efficiency to and from Iowa’s largest traffic generating events through the review of event specific traffic management components. Initially, three events were selected from the state of Iowa for inclusion in the SEP document. As Strategic Plans are developed for additional events, those events will be included in the SEP document. The three initial events that are included in this SEP are: • Iowa State Fair; • Iowa State University Home Football Games; • University of Iowa Home Football Games. The Strategic Plan for each event documents existing transportation conditions for the event based on field observations, highlights positive existing practices and issues for consideration, and provides recommendations, both short and long term, to be considered as potential improvements to event operations. The objective of each Strategic Plan was, at a high-level, to analyze traffic and pedestrian flow at each event and to work with event staff, agencies and others in developing roadway, operations and safety improvements where appropriate. The SEP document is intended to be a “living” document with updates to the Strategic Plans occurring as warranted and additional Strategic Plans being incorporated for other events. The enacting of recommendations contained within each Strategic Plan is not a mandate for the responsible agency for a particular event. The Strategic Plans are intended to provide a basis for discussion between the Iowa DOT and agencies involved in the planning and implementation of transportation operations for large traffic events regarding opportunities to improve the event patron’s experience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides updates on the WPAC recommendations made in its 2013 legislative report, including actions taken on those recommendations and any follow-up recommendations from WPAC. Recommendations include documentation of activities, and the needs and challenges toward making progress in protecting Iowa’s water resources, identified by WPAC in coordination with all agencies and stakeholders in the management of the state’s water resources in a sustainable, fiscally responsible, and environmentally conscientious manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides updates on the WPAC recommendations made in its 2013 legislative report, including actions taken on those recommendations and any follow-up recommendations from WPAC. Recommendations include documentation of activities, and the needs and challenges toward making progress in protecting Iowa’s water resources, identified by WPAC in coordination with all agencies and stakeholders in the management of the state’s water resources in a sustainable, fiscally responsible, and environmentally conscientious manner.