819 resultados para net savings
Resumo:
The construction industry is a large consumer of natural resources and one of the largest generators of residues with significant impacts on the environment. Because of the large production of Construction Industry Residues (RCC), it is essential reliable and updated information about generation, composition and classification sources of these residues, especially for management, recycling and final disposal. RCC represent the most part of solid residues generated in a city. In this way, the management of these residues is an issue that is gaining increasing importance in the Brazilian scenario, since the legal and society requirements to internalize the sustainability in the construction process - since the extraction, use, wastage savings, reutilization until the appropriate discard has been increasing in the last years. The present work objective is updating the quantities produced and collected in Guaratinguetá-SP, based on data collected with the municipal administrative entities that act direct or indirectly in the RCC management, elaborate a detailed bibliographic review, with special attention to the graduate works that were realized in FEG about this theme. With this material, scenarios to a better adequacy of the administrative structure to managements RCC activities, as well as was suggested actions to achieve these scenarios
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
Given the current energy crisis experienced in our country with the lack of rain in some areas, the energy distributors were forced to resort to thermal power plants to complement their energy production; raising the cost of electricity generation, they have been forced to repass this value to the customers through the Tariff Flags. Concerned about a substantial increase in their electric bill, some consumers were forced to look for alternatives so that their results are not affected. The use of diesel generation at peak hours is a relatively simple and inexpensive alternative that has been widely used for several industrial, commercial and service customers. In this present work, we conducted a feasibility study of the use of diesel generators at peak hours in a medium-sized hospital, calculating the depreciation period for the investment through savings in electricity bills
Resumo:
Pós-graduação em Agronomia (Proteção de Plantas) - FCA
Resumo:
The expansion of soybean cultivation into the Amazon in Brazil has potential hydrological effects at local to regional scales. To determine the impacts of soybean agriculture on hydrology, a comparison of net precipitation (throughfall, stemflow) in undisturbed tropical forest and soybean fields on the southern edge of the Amazon Basin in the state of Mato Grosso is needed. This study measured throughfall with troughs and stemflow with collar collectors during two rainy seasons. The results showed that in forest 91.6% of rainfall was collected as throughfall and 0.3% as stemflow, while in soybean fields with two-month old plants, 46.2% of rainfall was collected as throughfall and 9.0% as stemflow. Hence, interception of precipitation in soybean fields was far greater than in intact forests. Differences in throughfall, stemflow and net precipitation were found to be mainly associated with differences in plant structure and stem density in transitional forest and soybean cropland. Because rainfall interception in soybean fields is higher than previously believed and because both the area of cropland and the frequency of crop cycles (double cropping) are increasing rapidly, interception needs to be reconsidered in regional water balance models when consequences of land cover changes are analyzed in the Amazon soybean frontier region. Based on the continued expansion of soybean fields across the landscape and the finding that net precipitation is lower in soy agriculture, a reduction in water availability in the long term can be assumed. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Os organizadores autorizam a reprodução total ou parcial deste trabalho, para qualquer meio convencional ou eletrônico, para fins de estudo e pesquisa, desde que citada a fonte.
Resumo:
[EN] It was investigated whether skeletal muscle K(+) release is linked to the degree of anaerobic energy production. Six subjects performed an incremental bicycle exercise test in normoxic and hypoxic conditions prior to and after 2 and 8 wk of acclimatization to 4,100 m. The highest workload completed by all subjects in all trials was 260 W. With acute hypoxic exposure prior to acclimatization, venous plasma [K(+)] was lower (P < 0.05) in normoxia (4.9 +/- 0.1 mM) than hypoxia (5.2 +/- 0.2 mM) at 260 W, but similar at exhaustion, which occurred at 400 +/- 9 W and 307 +/- 7 W (P < 0.05), respectively. At the same absolute exercise intensity, leg net K(+) release was unaffected by hypoxic exposure independent of acclimatization. After 8 wk of acclimatization, no difference existed in venous plasma [K(+)] between the normoxic and hypoxic trial, either at submaximal intensities or at exhaustion (360 +/- 14 W vs. 313 +/- 8 W; P < 0.05). At the same absolute exercise intensity, leg net K(+) release was less (P < 0.001) than prior to acclimatization and reached negative values in both hypoxic and normoxic conditions after acclimatization. Moreover, the reduction in plasma volume during exercise relative to rest was less (P < 0.01) in normoxic than hypoxic conditions, irrespective of the degree of acclimatization (at 260 W prior to acclimatization: -4.9 +/- 0.8% in normoxia and -10.0 +/- 0.4% in hypoxia). It is concluded that leg net K(+) release is unrelated to anaerobic energy production and that acclimatization reduces leg net K(+) release during exercise.
Resumo:
[EN] We used 5-yr concomitant data of tracer distribution from the BATS (Bermuda Time-series Study) and ESTOC (European Station for Time-Series in the Ocean, Canary Islands) sites to build a 1-D tracer model conservation including horizontal advection, and then compute net production and shallow remineralization rates for both sites. Our main goal was to verify if differences in these rates are consistent with the lower export rates of particulate organic carbon observed at ESTOC. Net production rates computed below the mixed layer to 110m from April to December for oxygen, dissolved inorganic carbon and nitrate at BATS (1.34±0.79 molO2 m?2, ?1.73±0.52 molCm?2 and ?125±36 mmolNm?2) were slightly higher for oxygen and carbon compared to ESTOC (1.03±0.62 molO2 m?2, ?1.42±0.30 molCm?2 and ?213±56 mmolNm?2), although the differences were not statistically significant. Shallow remineralization rates between 110 and 250m computed at ESTOC (?3.9±1.0 molO2 m?2, 1.53±0.43 molCm?2 and 38±155 mmolNm?2) were statistically higher for oxygen compared to BATS (?1.81±0.37 molO2 m?2, 1.52± 0.30 molCm?2 and 147±43 mmolNm?2). The lateral advective flux divergence of tracers, which was more significant at ESTOC, was responsible for the differences in estimated oxygen remineralization rates between both stations. According to these results, the differences in net production and shallow remineralization cannot fully explain the differences in the flux of sinking organic matter observed between both stations, suggesting an additional consumption of nonsinking organic matter at ESTOC.