1000 resultados para lung artery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study investigated the effectiveness of stereotactic body radiotherapy with helical TomoTherapy (T-SBRT) for treating medically inoperable primary and second-primary early stage non-small-cell lung neoplasm (SPLN) and evaluated whether the movement of organizing pneumonia (OP) within the irradiation field (IF) can be detected via analysis of radiological changes. METHODS: Patients (n = 16) treated for 1 year (2011-12) at our hospital by T-SBRT at a total dose of 60 Gy in five fractions were examined retrospectively. Outcome and toxicity were recorded and were separately described for SPLN. CT scans were reviewed by a single radiologist. RESULTS: Of the 16 patients, 5 (31.3%) had primary lung malignancies, 10 (62.5%) had SPLN, and 1 case (6.3%) had isolated mediastinal metastasis of lung neoplasm. Pathological evidence was obtained for 72.2% of all lesions. The median radiological follow-up was 11 months (10.5 months for SPLN). For all cases, the 6- and 12-month survival rates were 100% and 77.7% (100% and 71.4%, respectively, for SPLN), and the 6- and 12-month locoregional control rates were 100% in all cases. 2 (12.5%) of 16 patients developed grade 3 late transient radiation pneumonitis following steroid therapy and 1 (6.3%) presented asymptomatic infiltrates comparable to OP opacities. CONCLUSION: T-SBRT seems to be safe and effective. ADVANCES IN KNOWLEDGE: Mild OP is likely associated with radiation-induced anomalies in the IF, identification of migrating opacities can help discern relapse of radiation-induced opacities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cancer mortality statistics for 2015 were projected from the most recent available data for the European Union (EU) and its six more populous countries. Prostate cancer was analysed in detail. PATIENTS AND METHODS: Population and death certification data from stomach, colorectum, pancreas, lung, breast, uterus, prostate, leukaemias and total cancers were obtained from the World Health Organisation database and Eurostat. Figures were derived for the EU, France, Germany, Italy, Poland, Spain and the UK. Projected 2015 numbers of deaths by age group were obtained by linear regression on estimated numbers of deaths over the most recent time period identified by a joinpoint regression model. RESULTS: A total of 1 359 100 cancer deaths are predicted in the EU in 2015 (766 200 men and 592 900 women), corresponding to standardised death rates of 138.4/100 000 men and 83.9/100 000 women, falling 7.5% and 6%, respectively, since 2009. In men, predicted rates for the three major cancers (lung, colorectum and prostate) are lower than in 2009, falling 9%, 5% and 12%. Prostate cancer showed predicted falls of 14%, 17% and 9% in the 35-64, 65-74 and 75+ age groups. In women, breast and colorectal cancers had favourable trends (-10% and -8%), but predicted lung cancer rates rise 9% to 14.24/100 000 becoming the cancer with the highest rate, reaching and possibly overtaking breast cancer rates-though the total number of deaths remain higher for breast (90 800) than lung (87 500). Pancreatic cancer has a negative outlook in both sexes, rising 4% in men and 5% in women between 2009 and 2015. CONCLUSIONS: Cancer mortality predictions for 2015 confirm the overall favourable cancer mortality trend in the EU, translating to an overall 26% fall in men since its peak in 1988, and 21% in women, and the avoidance of over 325 000 deaths in 2015 compared with the peak rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Rhinovirus is the most common cause of respiratory viral infections and leads to frequent respiratory symptoms in lung transplant recipients. However, it remains unknown whether the rhinovirus load correlates with the severity of symptoms. OBJECTIVES: This study aimed to better characterize the pathogenesis of rhinoviral infection and the way in which viral load correlates with symptoms. STUDY DESIGN: We assessed rhinovirus load in positive upper respiratory specimens of patients enrolled prospectively in a cohort of 116 lung transplant recipients. Rhinovirus load was quantified according to a validated in-house, real-time, reverse transcription polymerase chain reaction in pooled nasopharyngeal and pharyngeal swabs. Symptoms were recorded in a standardised case report form completed at each screening/routine follow-up visit, or during any emergency visit occurring during the 3-year study. RESULTS: Rhinovirus infections were very frequent, including in asymptomatic patients not seeking a specific medical consultation. Rhinovirus load ranged between 4.1 and 8.3 log copies/ml according to the type of visit and clinical presentation. Patients with highest symptom scores tended to have higher viral loads, particularly those presenting systemic symptoms. When considering symptoms individually, rhinovirus load was significantly higher in the presence of symptoms such as sore throat, fever, sputum production, cough, and fatigue. There was no association between tacrolimus levels and rhinovirus load. CONCLUSIONS: Rhinovirus infections are very frequent in lung transplant recipients and rhinoviral load in the upper respiratory tract is relatively high even in asymptomatic patients. Patients with the highest symptom scores tend to have a higher rhinovirus load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonographic detection of subclinical atherosclerosis improves cardiovascular risk stratification, but uncertainty persists about the most discriminative method to apply. In this study, we found that the "atherosclerosis burden score (ABS)", a novel straightforward ultrasonographic score that sums the number of carotid and femoral arterial bifurcations with plaques, significantly outperformed common carotid intima-media thickness, carotid mean/maximal thickness, and carotid/femoral plaque scores for the detection of coronary artery disease (CAD) (receiver operating characteristic (ROC) curve area under the curve (AUC) = 0.79; P = 0.027 to <0.001 with the other five US endpoints) in 203 patients undergoing coronary angiography. ABS was also more correlated with CAD extension (R = 0.55; P < 0.001). Furthermore, in a second group of 1128 patients without cardiovascular disease, ABS was weakly correlated with the European Society of Cardiology chart risk categories (R (2) = 0.21), indicating that ABS provided information beyond usual cardiovascular risk factor-based risk stratification. Pending prospective studies on hard cardiovascular endpoints, ABS appears as a promising tool in primary prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS: We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS: CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION: CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrosyneresis and double diffusion are immunoprecipitation techniques commonly used in the serological diagnosis of Farmer's lung disease (FLD). These techniques are reliable but lack standardization. The aim of this study was to evaluate Western blotting for the serodiagnosis of FLD. We carried out Western blotting with an antigenic extract of Lichtheimia corymbifera, an important aetiological agent of the disease. The membranes were probed with sera from 21 patients with FLD and 21 healthy exposed controls to examine the IgG antibody responses against purified somatic antigens. Given the low prevalence of the disease, 21 patients could be considered as a relevant series. Four bands were significantly more frequently represented in membranes probed with FLD sera (bands at 27.7, 40.5, 44.0 and 50.5 kDa) than those probed with control sera. We assessed the diagnostic value of different criteria alone or in combination. The diagnostic accuracy of the test was highest with the inclusion of at least two of the following criteria: at least five bands on the strip and the presence of one band at 40.5 or 44.0 kDa. Sensitivity, specificity and positive and negative predictive values were all 81%, and the odds ratio was 18.06. Inclusion of bands of high intensity diminished rather than improved the diagnostic value of the test. We concluded that Western blotting is a valuable technique for the serodiagnosis of FLD. The industrial production of ready-to-use membranes would enable the routine use of this technique in laboratories, and provide reliable and standardized diagnostic results within a few hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Immunohistochemistry (IHC) has become a promising method for pre-screening ALK-rearrangements in non-small cell lung carcinomas (NSCLC). Various ALK antibodies, detection systems and automated immunostainers are available. We therefore aimed to compare the performance of the monoclonal 5A4 (Novocastra, Leica) and D5F3 (Cell Signaling, Ventana) antibodies using two different immunostainers. Additionally we analyzed the accuracy of prospective ALK IHC-testing in routine diagnostics. MATERIALS AND METHODS: Seventy-two NSCLC with available ALK FISH results and enriched for FISH-positive carcinomas were retrospectively analyzed. IHC was performed on BenchMarkXT (Ventana) using 5A4 and D5F3, respectively, and additionally with 5A4 on Bond-MAX (Leica). Data from our routine diagnostics on prospective ALK-testing with parallel IHC, using 5A4, and FISH were available from 303 NSCLC. RESULTS: All three IHC protocols showed congruent results. Only 1/25 FISH-positive NSCLC (4%) was false negative by IHC. For all three IHC protocols the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) compared to FISH were 96%, 100%, 100% and 97.8%, respectively. In the prospective cohort 3/32 FISH-positive (9.4%) and 2/271 FISH-negative (0.7%) NSCLC were false negative and false positive by IHC, respectively. In routine diagnostics the sensitivity, specificity, PPV and NPV of IHC compared to FISH were 90.6%, 99.3%, 93.5% and 98.9%, respectively. CONCLUSIONS: 5A4 and D5F3 are equally well suited for detecting ALK-rearranged NSCLC. BenchMark and BOND-MAX immunostainers can be used for IHC with 5A4. True discrepancies between IHC and FISH results do exist and need to be addressed when implementing IHC in an ALK-testing algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cells from lung and other tissues are subjected to forces of opposing directions that are largely transmitted through integrin-mediated adhesions. How cells respond to force bidirectionality remains ill defined. To address this question, we nanofabricated flat-ended cylindrical Atomic Force Microscopy (AFM) tips with ~1 µm2 cross-section area. Tips were uncoated or coated with either integrin-specific (RGD) or non-specific (RGE/BSA) molecules, brought into contact with lung epithelial cells or fibroblasts for 30 s to form focal adhesion precursors, and used to probe cell resistance to deformation in compression and extension. We found that cell resistance to compression was globally higher than to extension regardless of the tip coating. In contrast, both tip-cell adhesion strength and resistance to compression and extension were the highest when probed at integrin-specific adhesions. These integrin-specific mechanoresponses required an intact actin cytoskeleton, and were dependent on tyrosine phosphatases and Ca2+ signaling. Cell asymmetric mechanoresponse to compression and extension remained after 5 minutes of tip-cell adhesion, revealing that asymmetric resistance to force directionality is an intrinsic property of lung cells, as in most soft tissues. Our findings provide new insights on how lung cells probe the mechanochemical properties of the microenvironment, an important process for migration, repair and tissue homeostasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among all inflammatory cells involved in COPD, those with a cytolytic or elastolytic activity are thought to play a key role in the pathogenesis of the disease. However, there is no data about the infiltration of cells expressing the CD57 marker in small airways and parenchyma of COPD patients. In this study, surgical specimens from 43 subjects undergoing lung resection due to lung cancer (9 non-smokers, 18 smokers without COPD and 16 smokers with moderate COPD) and 16 patients undergoing double lung transplantation for very severe COPD were examined. CD57+ cells, neutrophils, macrophages and mast cells infiltrating bronchioles (epithelium, smooth muscle and connective tissue) and parenchymal interstitium were localized and quantified by immunohistochemical analysis. Compared to the other groups, the small airways of very severe COPD patients showed a significantly higher density of CD57+ cells, mainly infiltrated in the connective tissue (p=0.001), and a significantly higher density of neutrophils located characteristically in the epithelium (p=0.037). Also, the density of neutrophils was significantly higher in parenchyma of very severe COPD patients compared with the rest of the groups (p=0.001). Finally, there were significant correlations between the bronchiolar density of CD57+ cells and the FEV1 values (R=-0.43, p=0.022), as well as between the parenchymal density of neutrophils and macroscopic emphysema degree (R=0.43, p=0.048) in COPD groups. These results show that CD57+ cells may be involved in COPD pathogenesis, especially in the most severe stages of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'imagerie par résonance magnétique (IRM) peut fournir aux cardiologues des informations diagnostiques importantes sur l'état de la maladie de l'artère coronarienne dans les patients. Le défi majeur pour l'IRM cardiaque est de gérer toutes les sources de mouvement qui peuvent affecter la qualité des images en réduisant l'information diagnostique. Cette thèse a donc comme but de développer des nouvelles techniques d'acquisitions des images IRM, en changeant les techniques de compensation du mouvement, pour en augmenter l'efficacité, la flexibilité, la robustesse et pour obtenir plus d'information sur le tissu et plus d'information temporelle. Les techniques proposées favorisent donc l'avancement de l'imagerie des coronaires dans une direction plus maniable et multi-usage qui peut facilement être transférée dans l'environnement clinique. La première partie de la thèse s'est concentrée sur l'étude du mouvement des artères coronariennes sur des patients en utilisant la techniques d'imagerie standard (rayons x), pour mesurer la précision avec laquelle les artères coronariennes retournent dans la même position battement après battement (repositionnement des coronaires). Nous avons découvert qu'il y a des intervalles dans le cycle cardiaque, tôt dans la systole et à moitié de la diastole, où le repositionnement des coronaires est au minimum. En réponse nous avons développé une nouvelle séquence d'acquisition (T2-post) capable d'acquérir les données aussi tôt dans la systole. Cette séquence a été testée sur des volontaires sains et on a pu constater que la qualité de visualisation des artère coronariennes est égale à celle obtenue avec les techniques standard. De plus, le rapport signal sur bruit fourni par la séquence d'acquisition proposée est supérieur à celui obtenu avec les techniques d'imagerie standard. La deuxième partie de la thèse a exploré un paradigme d'acquisition des images cardiaques complètement nouveau pour l'imagerie du coeur entier. La technique proposée dans ce travail acquiert les données sans arrêt (free-running) au lieu d'être synchronisée avec le mouvement cardiaque. De cette façon, l'efficacité de la séquence d'acquisition est augmentée de manière significative et les images produites représentent le coeur entier dans toutes les phases cardiaques (quatre dimensions, 4D). Par ailleurs, l'auto-navigation de la respiration permet d'effectuer cette acquisition en respiration libre. Cette technologie rend possible de visualiser et évaluer l'anatomie du coeur et de ses vaisseaux ainsi que la fonction cardiaque en quatre dimensions et avec une très haute résolution spatiale et temporelle, sans la nécessité d'injecter un moyen de contraste. Le pas essentiel qui a permis le développement de cette technique est l'utilisation d'une trajectoire d'acquisition radiale 3D basée sur l'angle d'or. Avec cette trajectoire, il est possible d'acquérir continûment les données d'espace k, puis de réordonner les données et choisir les paramètres temporel des images 4D a posteriori. L'acquisition 4D a été aussi couplée avec un algorithme de reconstructions itératif (compressed sensing) qui permet d'augmenter la résolution temporelle tout en augmentant la qualité des images. Grâce aux images 4D, il est possible maintenant de visualiser les artères coronariennes entières dans chaque phase du cycle cardiaque et, avec les mêmes données, de visualiser et mesurer la fonction cardiaque. La qualité des artères coronariennes dans les images 4D est la même que dans les images obtenues avec une acquisition 3D standard, acquise en diastole Par ailleurs, les valeurs de fonction cardiaque mesurées au moyen des images 4D concorde avec les valeurs obtenues avec les images 2D standard. Finalement, dans la dernière partie de la thèse une technique d'acquisition a temps d'écho ultra-court (UTE) a été développée pour la visualisation in vivo des calcifications des artères coronariennes. Des études récentes ont démontré que les acquisitions UTE permettent de visualiser les calcifications dans des plaques athérosclérotiques ex vivo. Cepandent le mouvement du coeur a entravé jusqu'à maintenant l'utilisation des techniques UTE in vivo. Pour résoudre ce problème nous avons développé une séquence d'acquisition UTE avec trajectoire radiale 3D et l'avons testée sur des volontaires. La technique proposée utilise une auto-navigation 3D pour corriger le mouvement respiratoire et est synchronisée avec l'ECG. Trois échos sont acquis pour extraire le signal de la calcification avec des composants au T2 très court tout en permettant de séparer le signal de la graisse depuis le signal de l'eau. Les résultats sont encore préliminaires mais on peut affirmer que la technique développé peut potentiellement montrer les calcifications des artères coronariennes in vivo. En conclusion, ce travail de thèse présente trois nouvelles techniques pour l'IRM du coeur entier capables d'améliorer la visualisation et la caractérisation de la maladie athérosclérotique des coronaires. Ces techniques fournissent des informations anatomiques et fonctionnelles en quatre dimensions et des informations sur la composition du tissu auparavant indisponibles. CORONARY artery magnetic resonance imaging (MRI) has the potential to provide the cardiologist with relevant diagnostic information relative to coronary artery disease of patients. The major challenge of cardiac MRI, though, is dealing with all sources of motions that can corrupt the images affecting the diagnostic information provided. The current thesis, thus, focused on the development of new MRI techniques that change the standard approach to cardiac motion compensation in order to increase the efficiency of cardioavscular MRI, to provide more flexibility and robustness, new temporal information and new tissue information. The proposed approaches help in advancing coronary magnetic resonance angiography (MRA) in the direction of an easy-to-use and multipurpose tool that can be translated to the clinical environment. The first part of the thesis focused on the study of coronary artery motion through gold standard imaging techniques (x-ray angiography) in patients, in order to measure the precision with which the coronary arteries assume the same position beat after beat (coronary artery repositioning). We learned that intervals with minimal coronary artery repositioning occur in peak systole and in mid diastole and we responded with a new pulse sequence (T2~post) that is able to provide peak-systolic imaging. Such a sequence was tested in healthy volunteers and, from the image quality comparison, we learned that the proposed approach provides coronary artery visualization and contrast-to-noise ratio (CNR) comparable with the standard acquisition approach, but with increased signal-to-noise ratio (SNR). The second part of the thesis explored a completely new paradigm for whole- heart cardiovascular MRI. The proposed techniques acquires the data continuously (free-running), instead of being triggered, thus increasing the efficiency of the acquisition and providing four dimensional images of the whole heart, while respiratory self navigation allows for the scan to be performed in free breathing. This enabling technology allows for anatomical and functional evaluation in four dimensions, with high spatial and temporal resolution and without the need for contrast agent injection. The enabling step is the use of a golden-angle based 3D radial trajectory, which allows for a continuous sampling of the k-space and a retrospective selection of the timing parameters of the reconstructed dataset. The free-running 4D acquisition was then combined with a compressed sensing reconstruction algorithm that further increases the temporal resolution of the 4D dataset, while at the same time increasing the overall image quality by removing undersampling artifacts. The obtained 4D images provide visualization of the whole coronary artery tree in each phases of the cardiac cycle and, at the same time, allow for the assessment of the cardiac function with a single free- breathing scan. The quality of the coronary arteries provided by the frames of the free-running 4D acquisition is in line with the one obtained with the standard ECG-triggered one, and the cardiac function evaluation matched the one measured with gold-standard stack of 2D cine approaches. Finally, the last part of the thesis focused on the development of ultrashort echo time (UTE) acquisition scheme for in vivo detection of calcification in the coronary arteries. Recent studies showed that UTE imaging allows for the coronary artery plaque calcification ex vivo, since it is able to detect the short T2 components of the calcification. The heart motion, though, prevented this technique from being applied in vivo. An ECG-triggered self-navigated 3D radial triple- echo UTE acquisition has then been developed and tested in healthy volunteers. The proposed sequence combines a 3D self-navigation approach with a 3D radial UTE acquisition enabling data collection during free breathing. Three echoes are simultaneously acquired to extract the short T2 components of the calcification while a water and fat separation technique allows for proper visualization of the coronary arteries. Even though the results are still preliminary, the proposed sequence showed great potential for the in vivo visualization of coronary artery calcification. In conclusion, the thesis presents three novel MRI approaches aimed at improved characterization and assessment of atherosclerotic coronary artery disease. These approaches provide new anatomical and functional information in four dimensions, and support tissue characterization for coronary artery plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The goal was to demonstrate that tailored therapy, according to tumor histology and epidermal growth factor receptor (EGFR) mutation status, and the introduction of novel drug combinations in the treatment of advanced non-small-cell lung cancer are promising for further investigation. METHODS: We conducted a multicenter phase II trial with mandatory EGFR testing and 2 strata. Patients with EGFR wild type received 4 cycles of bevacizumab, pemetrexed, and cisplatin, followed by maintenance with bevacizumab and pemetrexed until progression. Patients with EGFR mutations received bevacizumab and erlotinib until progression. Patients had computed tomography scans every 6 weeks and repeat biopsy at progression. The primary end point was progression-free survival (PFS) ≥ 35% at 6 months in stratum EGFR wild type; 77 patients were required to reach a power of 90% with an alpha of 5%. Secondary end points were median PFS, overall survival, best overall response rate (ORR), and tolerability. Further biomarkers and biopsy at progression were also evaluated. RESULTS: A total of 77 evaluable patients with EGFR wild type received an average of 9 cycles (range, 1-25). PFS at 6 months was 45.5%, median PFS was 6.9 months, overall survival was 12.1 months, and ORR was 62%. Kirsten rat sarcoma oncogene mutations and circulating vascular endothelial growth factor negatively correlated with survival, but thymidylate synthase expression did not. A total of 20 patients with EGFR mutations received an average of 16 cycles. PFS at 6 months was 70%, median PFS was 14 months, and ORR was 70%. Biopsy at progression was safe and successful in 71% of the cases. CONCLUSIONS: Both combination therapies were promising for further studies. Biopsy at progression was feasible and will be part of future SAKK studies to investigate molecular mechanisms of resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.