813 resultados para lost heat
Resumo:
Here we present two-phase flow nonlinear parameter estimation for HFC's flow through capillary tube-suction line heat exchangers, commonly used as expansion devices in small refrigeration systems. The simplifying assumptions adopted are: steady state, pure refrigerant, one-dimensional flow, negligible axial heat conduction in the fluid, capillary tube and suction line walls. Additionally, it is considered that the refrigerant is free from oil and both phases are assumed to be at the same pressure, that is, surface tension effects are neglected. Metastable flow effects are also disregarded, and the vapor is assumed to be saturated at the local pressure. The so-called homogeneous model, involving three, first order, ordinary differential equations is applied to analyze the two-phase flow region. Comparison is done with experimental measurements of the mass flow rate and temperature distribution along capillary tubes working with refrigerant HFC-134a in different operating conditions.
Resumo:
Statement of problem. Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. Purpose. The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. Material and methods. The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37°C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55°C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71°C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37°C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). Results. All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). Conclusion. Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550. Copyright © 2002 by The Editorial Council of The Journal of Prosthetic Dentistry.
Resumo:
Ross male broiler chicks (n = 480) on new litter were used in a randomized block design with two blocks (environmental rooms) and four treatments having four replicate pens (1.0 × 2.5 m; 15 chicks) each to evaluate dietary electrolyte balance (DEB; P < 0.05). Two rooms were 1) thermoneutral (Weeks 1 through 6, with decreasing maximum from 32 to 25°C and minimum from 28 to 19°C; relative humidity 49 to 58%) and 2) cyclic daily heat stress (Weeks 1 and 2, thermoneutral; Weeks 2 through 6, maximum temperatures 35, 35, 33, and 33°C, respectively; and minimum temperatures 23, 20, 19, and 19°C, respectively; relative humidity 51 to 54%). The DEB treatments (0, 140, 240, or 340 mEq Na + K - Cl/kg) had NaHCO3 plus NH4Cl, or KHCO3, or both added to corn-soybean meal mash basal diets with 0.30% salt (NaCl). In the thermoneutral room, DEB 240 increased 42-d weight gain and 44-d lymphocyte percentage and decreased heterophil percentage and heterophil to lymphocyte ratio compared to the DEB 40 treatment. The DEB 240 diets had 0.35 and 0.35% Na and 0.37% and 0.29% Cl in starter (0.75% K) and grower (0.67% K) diets, respectively. No DEB treatment differences were found in the heat stress room. For combined rooms, 42-d feed intake was higher for DEB 240 than for DEB 40. The 21-d weight gain was higher for DEB 240 than for DEB 40 or 140; and 21-d feed/gain was lower for DEB 40 than for DEB 340. The predicted maximum point of inflection for 21- and 42-d weight gains were DEB 250 and 201, with highest 42-d feed intake at 220.