996 resultados para laboratory angle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cystic fibrosis (CF) is a lifelong, inflammatory multi-organ disease and the most common lethal, genetic condition in Caucasian populations, with a median survival rate of 41.5 years. Pulmonary disease, characterized by infective exacerbations, bronchiectasis and increasing airway insufficiency is the most serious manifestation of this disease process, currently responsible for over 80% of CF deaths. Chronic dysregulation of the innate immune and host inflammatory response has been proposed as a mechanism central to this genetic condition, primarily driven by the nuclear factor κB (NF-κB) pathway. Chronic activation of this transcription factor complex leads to the production of pro-inflammatory cytokines and mediators such as IL-6, IL-8 and TNF-α. A20 has been described as a central and inducible negative regulator of NF-κB. This intracellular molecule negatively regulates NF-κB-driven pro-inflammatory signalling upon toll-like receptor activation at the level of TRAF6 activation. Silencing of A20 increases cellular levels of p65 and induces a pro-inflammatory state. We have previously shown that A20 expression positively correlates with lung function (FEV1%) in CF. Despite improvement in survival rates in recent years, advancements in available therapies have been incremental. We demonstrate that the experimental use of naturally occurring plant diterpenes such as gibberellin on lipopolysaccharide-stimulated cell lines reduces IL-8 release in an A20-dependent manner. We discuss how the use of a novel bio-informatics gene expression connectivity-mapping technique to identify small molecule compounds that similarly mimic the action of A20 may lead to the development of new therapeutic approaches capable of reducing chronic airway inflammation in CF. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A forward and backward least angle regression (LAR) algorithm is proposed to construct the nonlinear autoregressive model with exogenous inputs (NARX) that is widely used to describe a large class of nonlinear dynamic systems. The main objective of this paper is to improve model sparsity and generalization performance of the original forward LAR algorithm. This is achieved by introducing a replacement scheme using an additional backward LAR stage. The backward stage replaces insignificant model terms selected by forward LAR with more significant ones, leading to an improved model in terms of the model compactness and performance. A numerical example to construct four types of NARX models, namely polynomials, radial basis function (RBF) networks, neuro fuzzy and wavelet networks, is presented to illustrate the effectiveness of the proposed technique in comparison with some popular methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon distribution within perennial ryegrass was determined at different stages of plant development, by pulse-labelling laboratory and field-grown plants with 14C-CO2. During the early stages of growth (23-51 days), C distribution of laboratory grown plants was not markedly affected by plant age, with 12.4-24% of net assimilated label lost into the soil as root-soil respiration. The percentage of net assimilate translocated below ground was 20-28% during this stage of growth. At 65 days, the percentage of the label translocated below ground decreased to 8.1% of the net assimilate, with a subsequent decrease in root-soil respiration to 3.9%. The ability of the plant to fix the label (expressed in MBq g-1 oven dry total plant weight) decreased steadily as the plants aged. When the 30 day old plants were subjected to water stress (soil water potential -1.5 MPa) for 2 days before pulse-labelling, root-soil respiration of the pulse-label decreased compared with plants grown at field capacity. The distribution of a 14C pulse-label within perennial ryegrass grown under field conditions was found to be dependent on the age of the plants. For 4 week old plants, 67% of net assimilated label was translocated below ground, with 64.8% of this respired by the roots and soil. Less label was translocated below ground at subsequent pulse-labels from weeks 8 to 24. The proportion of label translocated below ground respired by the roots and soil also decreased. The investment of label in the plant shoots was found to be greater in field grown plants as compared to plants of the same age grown in a controlled, laboratory environment. © 1990.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reviews the books, Lessons From the Northern Ireland Peace Process edited by Timothy J. White (2013) and Human Rights as War by Other Means by Jennifer Curtis (2014). Edited by a U.S.-based academic with an enduring interest in Ireland, the first book draws together an interdisciplinary group of academics from across North America and the U.K. (though notably not Northern Ireland itself) to cover such topics as third party intervention, nationalism, grassroots change, and community development. The second text to be reviewed may be seen as a thorough analysis of this particular point: what is the role played by human rights in Northern Ireland’s peace process?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the applications of a novel methodology to quantify saltwater intrusion parameters in laboratory-scale experiments. The methodology uses an automated image analysis procedure, minimizing manual inputs and the subsequent systematic errors that can be introduced. This allowed the quantification of the width of the mixing zone which is difficult to measure in experimental methods that are based on visual observations. Glass beads of different grain sizes were tested for both steady-state and transient conditions. The transient results showed good correlation between experimental and numerical intrusion rates. The experimental intrusion rates revealed that the saltwater wedge reached a steady state condition sooner while receding than advancing. The hydrodynamics of the experimental mixing zone exhibited similar
traits; a greater increase in the width of the mixing zone was observed in the receding saltwater wedge, which indicates faster fluid velocities and higher dispersion. The angle of intrusion analysis revealed the formation of a volume of diluted saltwater at the toe position when the saltwater wedge is prompted to recede. In addition, results of different physical repeats of the experiment produced an average coefficient of variation less than 0.18 of the measured toe length and width of the mixing zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The integration of an ever growing proportion of large scale distributed renewable generation has increased the probability of maloperation of the traditional RoCoF and vector shift relays. With reduced inertia due to non-synchronous penetration in a power grid, system wide disturbances have forced the utility industry to design advanced protection schemes to prevent system degradation and avoid cascading outages leading to widespread blackouts. This paper explores a novel adaptive nonlinear approach applied to islanding detection, based on wide area phase angle measurements. This is challenging, since the voltage phase angles from different locations exhibit not only strong nonlinear but also time-varying characteristics. The adaptive nonlinear technique, called moving window kernel principal component analysis is proposed to model the time-varying and nonlinear trends in the voltage phase angle data. The effectiveness of the technique is exemplified using both DigSilent simulated cases and real test cases recorded from the Great Britain and Ireland power systems by the OpenPMU project.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Good Laboratory Practice has been a part of non-clinical research for over 40 years. Optimization Research, despite having many papers discussing standards being published over the same period of time, has yet to embrace standards that underpin its research. In this paper we argue the need to adopt standards in optimization research. Building on previous papers, many of which have suggested that the optimization research community should adopt certain standards, we suggest a concrete set of recommendations that the community should adopt. We also discuss how the proposals in this paper could be progressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter covers the indications, contraindications, techniques, outcomes, and complications of LPI. Its role is well defined in most of the areas, but no conclusion can be drawn at present regarding prophylactic use for glaucoma suspects. More studies are needed to define its safety and efficacy. Overall, LPI is a relatively safe procedure and the majority of complications can be avoided if it is performed properly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impact of laser peripheral iridotomy (LPI) on forward-scatter of light and subjective visual symptoms and to identify LPI parameters influencing these phenomena. DESIGN: Cohort study derived from a randomized trial, using an external control group. PARTICIPANTS: Chinese subjects initially aged 50 or older and 70 years or younger with bilateral narrow angles undergoing LPI in 1 eye selected at random, and age- and gender-matched controls. METHODS: Eighteen months after laser, LPI-treated subjects underwent digital iris photography and photogrammetry to characterize the size and location of the LPI, Lens Opacity Classification System III cataract grading, and measurement of retinal straylight (C-Quant; OCULUS, Wetzlar, Germany) in the treated and untreated eyes and completed a visual symptoms questionnaire. Controls answered the questionnaire and underwent straylight measurement and (in a random one-sixth sample) cataract grading. MAIN OUTCOME MEASURES: Retinal straylight levels and subjective visual symptoms. RESULTS: Among 230 LPI-treated subjects (121 [58.8%] with LPI totally covered by the lid, 43 [19.8%] with LPI partly covered by the lid, 53 [24.4%] with LPI uncovered by the lid), 217 (94.3%) completed all testing, as did 250 (93.3%) of 268 controls. Age, gender, and prevalence of visual symptoms did not differ between treated subjects and controls, although nuclear (P<0.01) and cortical (P = 0.03) cataract were less common among controls. Neither presenting visual acuity nor straylight score differed between the treated and untreated eyes among all treated persons, nor among those (n = 96) with LPI partially or totally uncovered. Prevalence of subjective glare did not differ significantly between participants with totally covered LPI (6.61%; 95% confidence interval [CI], 3.39%-12.5%), partially covered LPI (11.6%; 95% CI, 5.07%-24.5%), or totally uncovered LPI (9.43%; 95% CI, 4.10%-10.3%). In regression models, only worse cortical cataract grade (P = 0.01) was associated significantly with straylight score, and no predictors were associated with subjective glare. None of the LPI size or location parameters were associated with straylight or subjective symptoms. CONCLUSIONS: These results suggests that LPI is safe regarding measures of straylight and visual symptoms. This randomized design provides strong evidence that treatment programs for narrow angles would be unlikely to result in important medium-term visual disability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among Caucasians, it is well known that 75-95% of primary glaucoma is due to open-angle glaucoma (POAG), with angle-closure (PACG) comprising only a very small minority of cases. These figures are reversed among other groups such as Asians and Eskimos, where PACG makes up 80-90% of primary glaucoma. Among Eskimos, the prevalence of PACG has been reported as 2-8%, as compared to 0.1% among Caucasians. It appears that a population tendency toward shallow anterior chambers may explain the excess burden of PACG morbidity. Among Asians, the prevalence of PACG is intermediate between Caucasians and Eskimos. Existing biometrical data do not show a clear tendency toward shallower anterior chambers among Asians. PACG may be screened for on a population basis by means of various techniques that estimate axial or limbal anterior chamber depth, measure intraocular pressure, or evaluate the optic disc or visual fields. Demographic information and medical and family history will also be of great importance in screening for PACG in large populations. Groups at increased risk for the disease include women, individuals over 50, first-degree relatives of PACG probands, and hyperopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

562 residents of Jin Shan aged 40 years and above underwent examinations to compare the sensitivity and specificity of oblique flashlight, peripheral slit beam and ultrasonographic evaluation of the anterior chamber depth to gonioscopy in detecting cases of PACG. Among 5441 eligible individuals aged 40 and above, 562 (10.3%) underwent screening for PACG, of whom 17 (3.02%) were defined as cases, and 10 (1.78%) as suspects. Home visits indicated that respondents for screening were similar to the population as a whole. Only 35% of PACG cases reported symptoms consistent with acute angle closure, and only 18% were previously diagnosed. When compared to gonioscopy, only ultrasonographic measurement of AC depth provided an adequate mix of sensitivity and specificity. Ultrasonography in combination with tonometry provided a sensitivity of 88% with a specificity of 92%. Sensitivity and specificity for ultrasonography in combination with refractive status were 84% and 83% respectively. Shallower AC depth (p = 0.0001), shorter axial globe length (p = 0.001), greater than 2D of hyperopia (p < 0.001), high grades of nuclear sclerotic cataract (p < 0.0001) and an increased cup-to-disc ratio (p = 0.002) were significantly correlated with a diagnosis of PACG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Primary angle-closure glaucoma (PACG) is more prevalent among Chinese than whites. The authors tested the hypothesis that Chinese have shallower anterior chambers than do whites, a factor that may be related to PACG prevalence. METHODS: The authors compared anterior chamber depth, axial length, radius of corneal curvature, and refractive error among 531 Chinese, 170 whites, and 188 blacks older than 40 years of age using the same model of instruments and identical technique. RESULTS: Mean anterior chamber depth and axial length did not differ significantly for the three groups. Whites had a significantly higher prevalence of hyperopia > 2 diopters than did Chinese. Radius of corneal curvature was significantly smaller among Chinese than whites or blacks. CONCLUSIONS: These results suggest that Chinese do not differ on a population basis from other ethnic groups in many of the biometric risk factors known to be of importance for PACG. It will be necessary to identify other ocular biometric parameters to explain the excess burden of PACG among Chinese, which may improve the effectiveness of screening for this disease in all populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:

To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.

DESIGN:

Clinic-based validation and interobserver reliability trial.

PARTICIPANTS:

Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.

INTERVENTION:

In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).

MAIN OUTCOME MEASURES:

Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.

RESULTS:

In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).

CONCLUSION:

Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.