979 resultados para implant dentistry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article is to present the pediatric dentistry and orthodontic treatment protocol of rehabilitation of cleft lip and palate patients performed at the Hospital for Rehabilitation of Craniofacial Anomalies - University of So Paulo (HRAC-USP). Pediatric dentistry provides oral health information and should be able to follow the child with cleft lip and palate since the first months of life until establishment of the mixed dentition, craniofacial growth and dentition development. Orthodontic intervention starts in the mixed dentition, at 8-9 years of age, for preparing the maxillary arch for secondary bone graft procedure (SBGP). At this stage, rapid maxillary expansion is performed and a fixed palatal retainer is delivered before SBGP. When the permanent dentition is completed, comprehensive orthodontic treatment is initiated aiming tooth alignment and space closure. Maxillary permanent canines are commonly moved mesially in order to substitute absent maxillary lateral incisors. Patients with complete cleft lip and palate and poor midface growth will require orthognatic surgery for reaching adequate anteroposterior interarch relationship and good facial esthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study compared the biomechanical fixation and bone-to-implant contact (BIC) of implants with different surfaces treatment (experimental resorbable blasting media-processed nanometer roughness scale surface, and control dual acid-etched) in a dog model. Material and methods: Surface characterization was made in six implants by means of scanning electron microscopic imaging, atomic force microscopy to evaluate roughness parameters, and X-ray photoelectron spectroscopy (XPS) for chemical assessment. The animal model comprised the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Half of the specimens were biomechanically tested (torque), and the other half was subjected to histomorphologic/ morphometric evaluation. BIC and resistance to failure measures were each evaluated as a function of time and surface treatment in a mixed model ANOVA. Results: Surface texturing was significantly higher for the experimental compared with the control surface. The survey XPS spectra detected O, C, Al, and Ti at the control group, and Ca (similar to 0.2-0.9%) and P (similar to 1.7-4.1%) besides O, C, Al, and Ti at experimental surfaces. While no statistical difference in BIC was found between experimental and control surfaces or between 2 and 4 weeks in vivo, both longer time and use of experimental surface significantly increased resistance to failure. Conclusions: The experimental surface resulted in enhanced biomechanical fixation but comparable BIC relative to control, suggesting higher bone mechanical properties around the experimental implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The puerperium is the period of highest risk for thrombosis during a woman's reproductive life and it is an important time for initiating an effective contraceptive method in order to increase intergestational interval. Thus, the objective of the present study was to evaluated the effects of the etonogestrel (ENG)-releasing contraceptive implant inserted immediately postpartum on maternal hemostasis markers during the first six weeks of delivery. Materials and Methods: Forty healthy women aged 18 to 35 years-old were randomized to receive either the ENG-releasing implant 24-48 h after delivery (implant group; n=20) or nothing (control group) until the sixth postpartum week. Blood samples were collected at 24-48 h and at 6 weeks after delivery, and hemostatic variables, including fibrinogen, coagulation factors, protein C, free protein S, antithrombin, alpha 2-antiplasmin, plasminogen activator inhibitor 1, thrombin-antithrombin complex (TAT), prothrombin fragment (PF)1+2, and D-dimers, as well as normalized activated protein C sensitivity ratio (nAPCsr), thrombin time, activated partial thromboplastin time, and prothrombin time were evaluated. Results: Insertion of the ENG-releasing contraceptive implant did not change the physiological reduction in overall coagulation (TAT and PF1+2) and fibrinolysis (D-dimer) markers, or nAPCsr. Reductions in factors II, VII, X and fibrinogen and increases in factor V were greater in the control than in the implant group. Clotting factors remained within normal limits throughout the study. Conclusion: The ENG-releasing contraceptive implant inserted immediately postpartum did not have negative effects on physiological variations of the hemostatic system during the first 6 weeks postpartum. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To compare the biomechanical fixation and histomorphometric parameters between two implant surfaces: non-washed resorbable blasting media (NWRBM) and alumina-blasted/acid-etched (AB/AE), in a dog model. Material and methods: The surface topography was assessed by scanning electron microscopy, optical interferometry and chemistry by X-ray photoelectron spectroscopy (XPS). Six beagle dogs of similar to 1.5 years of age were utilized and each animal received one implant of each surface per limb (distal radii sites). After a healing period of 3 weeks, the animals were euthanized and half of the implants were biomechanically tested (removal torque) and the other half was referred to nondecalcified histology processing. Histomorphometric analysis considered bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Following data normality check with the Kolmogorov-Smirnov test, statistical analysis was performed by paired t-tests at 95% level of significance. Results: Surface roughness parameters Sa (average surface roughness) and Sq (mean root square of the surface) were significantly lower for the NWRBM compared with AB/ AE. The XPS spectra revealed the presence of Ca and P in the NWRBM. While no significant differences were observed for both BIC and BAFO parameters (P>0.35 and P>0.11, respectively), a significantly higher level of torque was observed for the NWRBM group (P = 0.01). Bone morphology was similar between groups, which presented newly formed woven bone in proximity with the implant surfaces. Conclusion: A significant increase in early biomechanical fixation was observed for implants presenting the NWRBM surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of sex, implant characteristics, and bone grafting on the survival rate of dual acid-etched (DAE) implants. Materials and Methods: Patients treated with internal-hex DAE implants for single-tooth replacement in a military dental clinic between January 2005 and December 2010 were included in this study. Clinical data related to implant characteristics, implant location, presence of grafted bone, and implant failures were collected. The primary outcome was implant loss. The survival rate was analyzed using the Kaplan-Meier method. Cox regression modeling was used to determine which factors would predict implant failure. Results: DAE implants were evaluated in a total of 988 patients (80.3% men). Twenty-four (2.4%) implants failed, most were cylindric (54.2%) with regular platforms (70.8%) and were 10 mm long (58.3%). The failure rate was 2.4% for the anterior maxilla, 3.3% for the posterior maxilla, 1.6% for the anterior mandible, and 2.0% for posterior mandible. The cumulative survival rate was 97.6%. The failure rate was 8.8% in implants placed after sinus augmentation, 7.3% in bone block-grafted areas, and 1.6% in native bone. Based on multivariable analysis (Cox regression), sinus augmentation and bone block grafting had a statistically significant effect on implant failure; the hazard ratios were 5.5 and 4.6, respectively. Conclusion: The results revealed that DAE implants had high survival rates, and no influence of sex, location, shape, diameter, or length on failure rates could be observed. However, a significant association was observed between failure and presence of bone graft in the implant area. Int J Oral Maxillofac Implants 2012;27:1243-1248

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neurovascular bundle may be vulnerable during surgical procedures involving the mandible, especially when anatomical variations are present. Increased demand of implant surgeries, wider availability of three-dimensional exams, and lack of clear definitions in the literature indicate that features of anatomical variations should be revisited. The objective of the study was to evaluate features of anatomical variations related to mandibular canal (MC), such as bifid canals, anterior loop of mental nerve, and corticalization of MC. Additionally, bone trabeculation at the submandibular gland fossa region (SGF) was assessed and related to visibility of MC. Cone beam computed tomography exams from 100 patients (200 hemimandibles) were analyzed and the following parameters were registered: diameter and corticalization of MC; trabeculation in SGF region; presence of bifid MC, position of bifurcations, diameter, and direction of bifid canals; and measurement of anterior loops by two methods. Corticalization of the MC was observed in 59% of hemimandibles. In 23%, MC could be identified despite absence of corticalization. Diameter of MC was between 2.1 and 4 mm for nearly three quarters of the sample. In 80% of the sample trabeculation at the SGF was either decreased or not visible, and such cases showed correlation with absence of MC corticalization. Bifid MC affected 19% of the patients, mostly associated with additional mental foramina. Clinically significant anterior loop (> 2 mm of anterior extension) was observed in 22-28%, depending on the method. Our findings, together with previously reported limitations of conventional exams, draw attention to the unpredictability related to anatomical variations in neurovascularization, showing the contribution of individual assessment through different views of three-dimensional imaging prior to surgical procedures in the mandible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cases of swallowing of foreign material related to dental implants during dental practice are described. A conservative approach by clinical-radiographic follow-up was performed in both cases; however, one of the patients required colonoscopy under general anesthesia for the removal of the impacted foreign body from the intestinal region. These complications not only have associated economic cost but also carry the risk of malpractice litigation against the professional; thus, the surgeon was responsible for all the costs of hospital and surgery management of this case. Details of the clinical signs, radiographic examinations, type of treatment, and follow-up are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention. Purpose. The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear. Material and methods. Seventy specimens of 3 groups of matrices of ball attachments that had been in use for mean periods of 12.3 months (1Y group, n=26), 39.0 months (3Y group, n=28) and 95.6 months (8Y group, n=16) were retrieved from 35 patients (2 specimens per patient) and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused matrices were used as controls (CTRL group). The external and internal matrix diameters and deviations from circularity were measured. For the various time periods, the decreases in matrix thickness were calculated and compared with controls. Kruskal-Wallis 1-way ANOVA by ranks, followed by the Mann-Whitney post hoc tests, were conducted to test for differences in median values among groups (alpha=.05). Results. For the internal upper diameter of the matrices tested, the Kruskal-Wallis and Mann-Whitney tests revealed significant differences for the 3 groups compared to the controls. For group 1Y, a significant difference (P<.001) of the internal upper diameter was found compared to the CTRL group. Compared to the controls, the nonparametric analyses for groups 3Y and 8Y showed significant differences for the internal upper diameter (P<.001) and deviations from circularity (P<.001). For groups 1Y, 3Y and 8Y, matrix thickness losses were 07, 47 and 70 pm, respectively. Conclusions. Within the limitations of this study, it was observed that one year of clinical wear had limited effect on the ball attachment matrices. Three to 8 years of clinical use resulted in a significant decrease of matrix thickness, especially at the tip of the retentive lamellae. (J Prosthet Dent 2012;107:191-198)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the role of transitory latex and sylastic (R) implants in tympanoplasty on the closure of tympanic perforations. METHODS: A randomized double-blind prospective study was conducted on 107 patients with chronic otitis media submitted to underlay tympanoplasty and divided at random into three groups: control with no transitory implant, latex membrane group, and sylastic (R) membrane group. RESULTS: Greater graft vascularization occurred in the latex membrane group (p<0.05). Good biocompatibility was obtained with the use of the latex and silicone implants, with no effect on the occurrence of infection, otorrhea or otorragy. CONCLUSION: The use of a transitory latex implant induced greater graft vascularization, with a biocompatible interaction with the tissue of the human tympanic membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of pore size on osteoblastic phenotype development in cultures grown on porous titanium (Ti). Porous Ti discs with three different pore sizes, 312 mu m (Ti 312), 130 mu m (Ti 130) and 62 mu m (Ti 62) were fabricated using a powder metallurgy process. Osteoblastic cells obtained from human alveolar bone were cultured on porous Ti samples for periods of up to 14 days. Cell proliferation was affected by pore size at day 3 (p = 0.0010), day 7 (p = 0.0005) and day 10 (p = 0.0090) in the following way: Ti 62 < Ti 130 < Ti 312. Gene expression of bone markers evaluated at 14 days was affected, RUNX2 (p = 0.0153), ALP (p = 0.0153), BSP (p = 0.0156), COL (p = 0.0156), and OPN (p = 0.0156) by pore size as follows: Ti 312 < Ti 130 < Ti 62. Based on these results, the authors suggest that porous Ti surfaces with pore sizes near 62 mu m, compared with those of 312 mu m and 130 mu m, yield the highest expression of osteoblast phenotype as indicated by the lower cell proliferation rate and higher gene expression of bone markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of cochlear implants (CI) for communication skills are obtained over the years. There are but a few studies regarding the long-term outcomes in postlingual deaf children who grew up using the electronic device. Aim: To assess the functional results in a group of postlingual children, 10 years after using a CI. Methods: Ten postlingual deaf children, implanted before 18 years of age, participated in this study. We assessed: sentence recognition and speech intelligibility. We documented: device use and function and the patient's academic/occupational status. Study design: series. Results: The mean scores were 73% for sentence recognition in silence and 40% in noise. The average write-down intelligibility score was 92% and the average rating-scale intelligibility score was 4.15. There were no cases of device failure. Regarding educational/vocational status, three subjects graduated from the University. Five quit education after completing high school. Eight subjects had a professional activity. Conclusion: This study showed that cochlear implantation is a safe and reliable procedure. The postlingual profoundly hearing-impaired children after 10 years of CI use developed satisfactory levels regarding speech perception and intelligibility, and completed at least high school and were inserted in the labor market. Clinical Trials Registry: NCT01400178.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the dimensions of gingival papillae in anterosuperior areas presenting at natural teeth (teeth sites) or single-tooth implants adjacent to natural teeth (implant-tooth sites) by analyzing determined distances. A total of 45 teeth and 46 implant-tooth sites were carefully selected. Clinical evaluation consisted of visual and quantitative analyses with millimeter grids on radiographs. Implant-tooth sites showed a smaller gingival papilla dimension than tooth sites (P < .01). Both evaluated distances (contact point to bone crest and between the roots of adjacent teeth or implant platform to root of adjacent tooth) in all groups significantly influenced the presence/absence of gingival papillae (P < .01). (Int J Periodontics Restorative Dent 2012;32:93-100.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To verify if mini-implant mobility is affected by the presence of periodontopathogens, frequently associated with peri-implantitis. Materials and Methods: The surfaces of 31 mini-implants used for skeletal anchorage in orthodontic patients were evaluated. Polymerase chain reaction was used for identification of the presence of DNA from three different periodontopathogens (P. intermedia [Pi], A. actinomycetemcomitans [Aa], and P. gingivalis [Pg]) in 16 mini-implants without mobility (control group) and 15 mini-implants with mobility (experimental group). Results: The results showed that Pi was present in 100% of the samples, from both groups: Aa was found in 31.3% of the control group and in 13.3% of the experimental group. Pg was detected in 37.4% of the control group and in 33.3% of the experimental group. The Fisher exact test and the odds ratio (OR) values for Aa and Pg (OR = 0.34; 95% confidence interval [CI]: 0.05-2.10 and OR = 0.61; 95% Cl: 0.13-2.79, respectively) showed no significant association (P > .05) between the periodontopathogens studied and the mobility of the mini-implants. Conclusions: It can be concluded that the presence of Aa, Pi, and Pg around mini-implants is not associated with mobility. (Angle Orthod. 2012;82:591-595.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aimed to investigate the antimicrobial properties and cytotoxicity of the monomer methacryloyloxyundecylpyridinium bromide (MUPB), an antiseptic agent capable of copolymerizing with denture base acrylic resins. Materials and Methods: The antimicrobial activity of MUPB was tested against the species Candida albicans, Candida dubliniensis, Candida glabrata, Lactobacillus casei, Staphylococcus aureus, and Streptococcus mutans. The minimum inhibitory and fungicidal/bactericidal concentrations (MIC, MFC/MBC) of MUPB were determined by serial dilutions in comparison with cetylpyridinium chloride (CPC). The cytotoxic effects of MUPB at concentrations ranging from 0.01 to 1 g/L were assessed by MTT test on L929 cells and compared with methyl methacrylate (MMA). The antimicrobial activity of copolymerized MUPB was tested by means of acrylic resin specimens containing three concentrations of the monomer (0, 0.3, 0.6% w/w). Activity was quantified by means of a disc diffusion test and a quantification of adhered planktonic cells. Statistical analysis employed the Mann-Whitney test for MIC and MFC/MBC, and ANOVA for the microbial adherence test (a= 0.05). Results: MUBP presented lower MIC values when compared with CPC, although differences were significant for C. dubliniensis and S. mutans only (p= 0.046 and 0.043, respectively). MFC/MBC values were similar for all species except C. albicans; in that case, MUPB presented significantly higher values (p= 0.046). MUPB presented higher cytotoxicity than MMA for all tested concentrations (p < 0.001) except at 0.01 g/L. Irrespective of the concentration incorporated and species, there was no inhibition halo around the specimens. The incorporation of MUPB influenced the adhesion of C. albicans only (p= 0.003), with lower CFU counts for the 0.6% group. Conclusions: It was concluded that non-polymerized MUPB has an antimicrobial capacity close to that of CPC and high cytotoxicity when compared with MMA. The antimicrobial activity of MUPB after incorporation within a denture base acrylic resin did not depend on its elution, but was shown to be restricted to C. albicans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Adequate denture hygiene can prevent and treat infection in edentulous patients, who are frequently elderly and have difficulty brushing their teeth. This study evaluated the efficacy of complete denture biofilm removal using a chlorhexidine solution in two concentrations: 0.12% and 2.0%. Materials and Methods: Sixty complete denture wearers participated in a trial for 21 days after receiving brushing instructions. They were distributed into three groups, according to the tested solution and regimen (n = 20): (G1) Control (daily overnight soaking in water); (G2) daily immersion at home in 0.12% chlorhexidine for 20 minutes after dinner; and (G3) a single immersion in 2.0% chlorhexidine for 5 minutes at the end of the experimental period, performed by a professional. Biofilm coverage area (%) was quantified on the internal surface of maxillary dentures at baseline and after 21 days. Afterward, the differences between initial and posttreatment results were compared by means of the Kruskal-Wallis test (a = 0.05). Results: Median values for biofilm coverage area after treatment were: (G1) 36.0%; (G2) 5.3%; and (G3) 1.4%. Differences were significant (KW = 35.25; p < 0.001), although G2 and G3 presented similar efficacy in terms of biofilm removal. Conclusions: Both chlorhexidine-based treatments had a similar ability to remove denture biofilm. Immersion in 0.12% or 2.0% chlorhexidine solutions can be used as an auxiliary method for cleaning complete dentures.