976 resultados para fluorescence emission spectra
Resumo:
Keywords Diabetes mellitus; coronary artery disease; myocardial ischemia; prognostic value; single-photon emission computed tomography myocardial perfusion imaging Summary Aim: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. Methods: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curves and independent predictors were determined by Cox multivariate analyses. Results: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65±10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p<.0001), followed by history of CAD (Hazard Ratio (HR)= t 5.9, p=0.0001), diabetic retinopathy (HR=10.0, p=0.001) and inability to exercise (HR=7.7, p=0.02). Patients with normal 1VIPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. Conclusion: Diabetic patients with normal MPI had an excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a > 5 fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients. Mots-Clés Diabète; maladie coronarienne; ischémie myocardique; valeur pronostique; tomoscintigraphie myocardique de perfusion par émission monophotonique Résumé Objectifs: Déterminer la valeur pronostique à long terme de la tomoscintigraphie myocardique de perfusion (TSMP) chez les patients diabétiques pour prédire les événements cardiovasculaires (ECV). Méthodes: Etude de 210 diabétiques caucasiens consécutifs référés pour une TSMP. Les courbes de survie ont été déterminées par Kaplan-Meier et les facteurs prédictifs indépendants par analyses multivariées de type Cox. Résultats: Le suivi a été complet chez 200 (95%) patients avec une durée médiane de 3.0 ans (0.8-50). La population était composée de 114 (57%) hommes, âge moyen 65±10 ans, avec 181 (90.5%) diabète de type 2, 50 (25%) antécédents de maladie coronarienne (AMC) et 98 (49%) patients connus pour un angor avant la TSMP. La prévalence de TSMP anormales était de 58%. Aucun décès d'origine cardiaque ou infarctus du myocarde n'est survenu chez les patients avec une TSMP normale, ceci indépendamment de leurs AMC et des douleurs thoraciques. Les facteurs prédictifs indépendants pour les ECV sont une TSMP anormale (p<.0001), les AMC (Hazard Ratio (HR)=15.9, p-0.0001), suivi de la rétinopathie diabétique (HR-10.0, p=0.001) et de l'incapacité à effectuer un exercice (HR=7.7, p=0.02). Les patients avec une TSMP normale ont présenté un taux de revascularisations de 2.4%. La présence de défauts mixtes accroît le risque d'ECV de 20.1 fois, les défauts fixes de 8.5 fois et les défauts réversibles de 5.2 fois comparés aux sujets avec une TSMP normale. Conclusion: Les patients diabétiques, coronariens ou non, avec une tomoscintigraphie myocardique de perfusion normale ont un excellent pronostique. A l'opposé, une TSMP anormale est associée à une augmentation du risque d'ECV de plus de 5 fois. Ceci confirme l'utilité de la TSMP dans la stratification du risque chez les patients diabétiques.
Resumo:
BACKGROUND To compare outcomes for patients with recurrent or persistent papillary thyroid cancer (PTC) who had metastatic tumors that were fluorodeoxyglucose-positron emission tomography (FDG-PET) positive or negative, and to determine whether the FDG-PET scan findings changed the outcome of medical and surgical management. METHODS From a prospective thyroid cancer database, we retrospectively identified patients with recurrent or persistent PTC and reviewed data on demographics, initial stage, location and extent of persistent or recurrent disease, clinical management, disease-free survival and outcome. We further identified subsets of patients who had an FDG-PET scan or an FDG-PET/CT scan and whole-body radioactive iodine scans and categorized them by whether they had one or more FDG-PET-avid (PET-positive) lesions or PET-negative lesions. The medical and surgical treatments and outcome of these patients were compared. RESULTS Between 1984 and 2008, 41 of 141 patients who had recurrent or persistent PTC underwent FDG-PET (n = 11) or FDG-PET/CT scans (n = 30); 22 patients (54%) had one or more PET-positive lesion(s), 17 (41%) had PET-negative lesions, and two had indeterminate lesions. Most PET-positive lesions were located in the neck (55%). Patients who had a PET-positive lesion had a significantly higher TNM stage (P = 0.01), higher age (P = 0.03), and higher thyroglobulin (P = 0.024). Only patients who had PET-positive lesions died (5/22 vs. 0/17 for PET-negative lesions; P = 0.04). In two of the seven patients who underwent surgical resection of their PET-positive lesions, loco-regional control was obtained without evidence of residual disease. CONCLUSION Patients with recurrent or persistent PTC and FDG-PET-positive lesions have a worse prognosis. In some patients loco-regional control can be obtained without evidence of residual disease by reoperation if the lesion is localized in the neck or mediastinum.
Resumo:
Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.
Resumo:
Todos los cuerpos emiten luz espontaneamente al ser calentados. El espectro de radiacion es una funcion de la temperatura y el material. Sin embargo, la mayoria de los materiales irradia, en general, en una banda espectral amplia. Algunas matereiales, por el contrario, son capaces de concentrar la radiacion termica en una banda espectral mucho mas estrecha. Estos materiales se conocen como emisores selectivos y su uso tiene un profundo impacto en la eficiencia de sistemas sistemas tales como iluminacion y conversion de energia termofotovoltaica. De los emisores selectivos se espera que sean capaces de operar a altas temperaturas y que emitan en una banda espectral muy concisa. Uno de los metodos mas prometedores para controlar y disenar el espectro de emision termico es la utilizacion de cristales fotonicos. Los cristales fotonicos son estructuras periodicas artificiales capaces de controlar y confinar la luz de formas sin precedentes. Sin embargo, la produccion de dichas estructuras con grandes superficies y capaces de soportar altas temperaturas sigue siendo una dificil tarea. Este trabajo esta dedicada al estudio de las propiedades de emision termica de estructuras 3D de silicio macroporoso en el rango espectral mid-IR (2-30 m). En particular, este trabajo se enfoca en reducir la elevada emisividad del silicio cristalino. Las muestras estudiadas en este trabajo tienen una periodicidad de 4 m, lo que limitan los resultados obtenidos a la banda del infrarrojo medio, aunque estructuras mucho mas pequenas son tecnologicamente realizables con el metodo de fabricacion utilizado. Hemos demostrado que el silicio macroporoso 3D puede inhibir completamente la emision termica en su superficie. Mas aun, esta banda se puede ajustar en un amplio margen mediante pequenos cambios durante la formacion de los macroporos. Tambien hemos demostrado que tanto el ancho como la frecuencia de la banda de inhibicion se puede doblar mediante la aplicacion de tecnicas de postprocesado adecuadas. Finalmente hemos mostrado que es posible crear bandas de baja emisividad arbitrariamente anchas mediante estructuras macroporosas aperiodicas.
Resumo:
It has been demonstrated in earlier studies that patients with a cochlear implant have increased abilities for audio-visual integration because the crude information transmitted by the cochlear implant requires the persistent use of the complementary speech information from the visual channel. The brain network for these abilities needs to be clarified. We used an independent components analysis (ICA) of the activation (H2 (15) O) positron emission tomography data to explore occipito-temporal brain activity in post-lingually deaf patients with unilaterally implanted cochlear implants at several months post-implantation (T1), shortly after implantation (T0) and in normal hearing controls. In between-group analysis, patients at T1 had greater blood flow in the left middle temporal cortex as compared with T0 and normal hearing controls. In within-group analysis, patients at T0 had a task-related ICA component in the visual cortex, and patients at T1 had one task-related ICA component in the left middle temporal cortex and the other in the visual cortex. The time courses of temporal and visual activities during the positron emission tomography examination at T1 were highly correlated, meaning that synchronized integrative activity occurred. The greater involvement of the visual cortex and its close coupling with the temporal cortex at T1 confirm the importance of audio-visual integration in more experienced cochlear implant subjects at the cortical level.
Resumo:
In high hyperdiploid acute lymphoblastic leukemia (ALL), the concurrence of specific trisomies confers a more favorable outcome than hyperdiploidy alone. Interphase fluorescence in situ hybridization (FISH) complements conventional cytogenetics (CC) through its sensitivity and ability to detect chromosome aberrations in nondividing cells. To overcome the limits of manual I-FISH, we developed an automated four-color I-FISH approach and assessed its ability to detect concurrent aneuploidies in ALL. I-FISH was performed using centromeric probes for chromosomes 4, 6, 10, and 17. Parameters established for nucleus selection and signal detection were evaluated. Cutoff values were determined. Combinations of aneuploidies were considered relevant when each aneuploidy was individually significant. Results obtained in 10 patient samples were compared with those obtained with CC. Various combinations of aneuploidies were identified. All clones detected by CC were observed also by I-FISH, and I-FISH revealed numerous additional abnormal clones in all patients, ranging from < or =1% to 31.6% of cells analyzed. We conclude that four-color automated I-FISH permits the identification of concurrent aneuploidies of potential prognostic significance. Large numbers of cells can be analyzed rapidly. The large number of nuclei scored revealed a high level of chromosome variability both at diagnosis and relapse, the prognostic significance of which is of considerable clinical interest and merits further evaluation.
Resumo:
Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning.
Resumo:
The subject of this project is about “Energy Dispersive X-Ray Fluorescence ” (EDXRF).This technique can be used for a tremendous variety of elemental analysis applications.It provides one of the simplest, most accurate and most economic analytical methods for thedetermination of the chemical composition of many types of materials.The purposes of this project are:- To give some basic information about Energy Dispersive X-ray Fluorescence.- To perform qualitative and quantitative analysis of different samples (water-dissolutions,powders, oils,..) in order to define the sensitivity and detection limits of the equipment.- To make a comprehensive and easy-to-use manual of the ‘ARL QUANT’X EnergyDispersive X-Ray Fluorescence’ apparatus
Resumo:
Tetrasomy 8 constitutes a relatively rare recurring chromosome defect in myeloid disorders. The patient reported here, a 71-year-old man, presented with tetrasomy 8 as the sole chromosome abnormality associated with an acute nonlymphocytic leukemia of the M2 type. He failed to respond to chemotherapy and died one year after diagnosis. Following conventional cytogenetics and fluorescence in situ hybridization (FISH) with a centromeric probe specific for chromosome 8, tetrasomy 8 was detected in 61% of the metaphases analyzed and trisomy 8 in 39%. FISH analysis of interphase nuclei confirmed the existence of tetrasomic (35%) and trisomic cells (56%) and revealed a number of cells with two chromosomes 8 (8%). This normal population may represent lymphocytes or myeloid cells that escaped conventional analysis due to their inability to divide or to the small number of metaphases available. The relatively higher proportion of tetrasomic cells in metaphase compared with interphase may be attributed to a proliferative advantage of tetrasomic cells in vitro or to the longer duration of their cell cycle. The simultaneous presence of trisomic and tetrasomic cells confirms the hypothesis of a clonal relationship between trisomy 8 and tetrasomy 8. Our case brings further evidence to the specificity of tetrasomy 8 to myeloid disorders and to the association of this chromosome abnormality with a relatively poor prognosis. However, new patients must be studied to further delineate this cytogenetic entity.
Resumo:
Les maladies cardiovasculaires restent la cause de mortalité la plus élevée dans le monde occidental. Il s'agit d'un processus long et complexe, dont l'infarctus du myocarde et la mort cardiaque ne sont que la fin d'un spectrum. La perfusion myocardique joue un rôle central dans l'évolution de la maladie et survient chronologiquement en amont de la dysfonction diastolique et systolique, ainsi que de l'infarctus du myocarde. Une meilleure compréhension de la Physiopathologie sous-jacente est cruciale dans le diagnostique et la prise en charge du patient. Dans ce sens, ce travail tente d'évaluer l'apport de l'évaluation de la perfusion myocardique évaluée par la tomographic à émission de positron (PET/CT) quant à la prédiction d'événements cardiovasculaires. De plus, l'apport de l'évaluation quantitative par rapport à l'évaluation qualitative a été démontré dans ce travail. Nous avons utilisé un radiotraceur unique au regard de ses caractéristiques. En effet, Le Rubidium-82 est un traceur qui ne nécessite pas d'un cyclotron pour sa fabrication, dès lors qu'il est produit par un générateur, rendant ainsi sa disponibilité un atout et un avantage potentiel lors de futurs implémentations à plus grande échelle. Ce travail démontre la supériorité de l'analyse de perfusion myocardique quantitative par rapport à l'analyse traditionnelle qualitative, ce qui n'était pas encore confirmé avec le Rubidium-82. Les résultats montrent une démarcation significative entre les différentes valeurs de perfusion quantitative/absolue, permettant de distinguer différentes populations plus ou moins à risque en terme de prédiction d'événements cardiaques futurs. Il est intéressant de noter que dans un modèle combinant l'analyse qualitative et quantitative proposé dans ce travail, l'inclusion des résultats les plus ischémiques obtenus par l'analyse qualitative avec les résultats de perfusion les plus bas en terme de flux myocardique absolu (analyse quantitative) démarque une population à très bas risque d'événements cardiovasculaires majeurs, une prédiction pouvant être observée surplus de 1'000 jours. Ces résultats forment un ajout significatif quant à l'évaluation de la perfusion myocardique par la médecine nucléaire, notamment par ce model intégratif proposé, lequel permet une prédiction précise et contributive dans le cadre de futurs événements cardiovasculaires majeurs.
Resumo:
The classical description of Si oxidation given by Deal and Grove has well-known limitations for thin oxides (below 200 Ã). Among the large number of alternative models published so far, the interfacial emission model has shown the greatest ability to fit the experimental oxidation curves. It relies on the assumption that during oxidation Si interstitials are emitted to the oxide to release strain and that the accumulation of these interstitials near the interface reduces the reaction rate there. The resulting set of differential equations makes it possible to model diverse oxidation experiments. In this paper, we have compared its predictions with two sets of experiments: (1) the pressure dependence for subatmospheric oxygen pressure and (2) the enhancement of the oxidation rate after annealing in inert atmosphere. The result is not satisfactory and raises serious doubts about the model’s correctness
Resumo:
We diagnosed a non-small cell lung carcinoma in a 49-year-old female patient with the histopathological diagnosis of stage IIIB mixed bronchioloalveolar and papillary adenocarcinoma with extensive micropapillary feature, which was not visualized on the preoperative multimodality imaging with positron emission tomography (PET) and computed tomography (CT). The micropapillary component characterized by a unique growth pattern with particular morphological features can be observed in all subtypes of lung adenocarcinoma. Micropapillary component is increasingly recognized as a distinct entity associated with higher aggressiveness. Even the most modern multimodality PET/CT imaging technology may fail to adequately visualize this important component with highly relevant prognostic implications. Thus, the pathologist needs to consciously look for a micropapillary component in the surgical specimen or in preoperative biopsies or cytology. This may have potential future treatment implications, as adjuvant or neoadjuvant chemotherapy may be of relevance, even in the early stages of the disease.
Resumo:
PURPOSE: F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and MRI are used for detecting liver metastases from uveal melanoma. The introduction of new treatment options in clinical trials might benefit from early response assessment. Here, we determine the value of FDG-PET/CT with respect to MRI at diagnosis and its potential for monitoring therapy. MATERIAL AND METHODS: Ten patients with biopsy-proven liver metastases of uveal melanoma enrolled in a randomized phase III trial (NCT00110123) underwent both FDG-PET coupled with unenhanced CT and gadolinium-diethylene triamine pentaacetic acid-enhanced liver MRI within 4 weeks. FDG-PET and MRI were evaluated blindly and then compared using the ratio of lesion to normal liver parenchyma PET-derived standardized uptake value (SUV). The influence of lesion size and response to chemotherapy were studied. RESULTS: Overall, 108 liver lesions were seen: 34 (31%) on both modalities (1-18 lesions/patient), four (4%) by PET/CT only, and 70 (65%) by MRI only. SUV correlated with MRI lesion size (r=0.81, P<0.0001). PET/CT detected 26 of 33 (79%) MRI lesions of more than or equal to 1.2 cm, whereas it detected only eight of 71 (11%) lesions of less than 1.2 cm (P<0.0001). MRI lesions without PET correspondence were small (0.6±0.2 vs. 2.1±1.1 cm, P<0.0001). During follow-up (six patients, 30 lesions), the ratio lesion-to-normal-liver SUV diminished in size-stable lesions (1.90±0.64-1.46±0.50, P<0.0001), whereas it increased in enlarging lesions (1.56±0.40-1.99±0.56, P=0.032). CONCLUSION: MRI outweighs PET/CT for detecting small liver metastases. However, PET/CT detected at least one liver metastasis per patient and changes in FDG uptake not related to size change, suggesting a role in assessing early therapy response.
Resumo:
Antibiotic-resistant pathogens are a major health concern in everyday clinical practice. Because their detection by conventional microbial techniques requires minimally 24 h, some of us have recently introduced a nanomechanical sensor, which can reveal motion at the nanoscale. By monitoring the fluctuations of the sensor, this technique can evidence the presence of bacteria and their susceptibility to antibiotics in less than 1 h. Their amplitude correlates to the metabolism of the bacteria and is a powerful tool to characterize these microorganisms at low densities. This technique is new and calls for an effort to optimize its protocol and determine its limits. Indeed, many questions remain unanswered, such as the detection limits or the correlation between the bacterial distribution on the sensor and the detection's output. In this work, we couple fluorescence microscopy to the nanomotion investigation to determine the optimal experimental protocols and to highlight the effect of the different bacterial distributions on the sensor.