833 resultados para fault accommodation
Resumo:
This paper discusses the control and protection of a microgrid that is connected to utility through back-to-back converters. The back-to-back converter connection facilitates bidirectional power flow between the utility and the microgrid. These converters can operate in two different modes–one in which a fixed amount of power is drawn from the utility and the other in which the microgrid power shortfall is supplied by the utility. In the case of a fault in the utility or microgrid side, the protection system should act not only to clear the fault but also to block the back-to-back converters such that its dc bus voltage does not fall during fault. Furthermore, a converter internal mechanism prevents it from supplying high current during a fault and this complicates the operation of a protection system. To overcome this, an admittance based relay scheme is proposed, which has an inverse time characteristic based on measured admittance of the line. The proposed protection and control schemes are able to ensure reliable operation of the microgrid.
Resumo:
A number of recent legislative amendments impact on property law practice in Queensland. Property Law (Mortgagor Protection) Amendment Act 2008 (Qld) Body Corporate and Community Management Amendment Act 2009 (Qld) Residential Tenancies and Rooming Accommodation Act 2008 (Qld) Sustainable Planning Act 2009 (Qld) Vegetation Management and Other Legislation Amendment Bill 2009 (Qld) Property Agents and Motor Dealers Act 2000 (Qld)
Resumo:
Faced with the need for strategic change, structural and cultural realignment, innovation and value-adding, many public sector organisations are tapping into a wider senior leadership talent pool and attracting successful leaders from other sectors (Flynn and Thompson, 2009). Leadership renewal has resulted, in some cases, in the external recruitment of whole senior leadership teams (Hockridge, 2008), raising issues about the influence of context on leader success (Pawar and Eastman, 1997) and potential leader transition failure, a costly outcome for leaders and organisations (Howard, 2001). There is little research on inter-sector leader transitions, which is surprising given the significant costs associated with leader acquisition and failure(Conger, 2010; Day and Halpin, 2004). For example, it is not clear what organizations do (or do not do) to ensure the outcomes of their significant investment in inter sector transitions are realised. In addition, it is not clear how the individual leader manages the challenging transition into a new leadership context and how their approach to leadership facilitates or inhibits successful transition (Avolio, 2010). Leader assimilation programs have been developed to assimilate new leaders (Manderscheid, 2008); however, assimilation is not necessarily a desired organisational outcome (Denis and Pineault, 2000). In this paper we critically review the limited literature on inter-sector leader transitions and transformational change outcomes and argue for a mutual accommodation approach. We draw on our own initial empirical work to propose the elements of a program for achieving this outcome from the perspective of the public organisation and the inter-sector appointee.
Resumo:
This paper presents an approach to predict the operating conditions of machine based on classification and regression trees (CART) and adaptive neuro-fuzzy inference system (ANFIS) in association with direct prediction strategy for multi-step ahead prediction of time series techniques. In this study, the number of available observations and the number of predicted steps are initially determined by using false nearest neighbor method and auto mutual information technique, respectively. These values are subsequently utilized as inputs for prediction models to forecast the future values of the machines’ operating conditions. The performance of the proposed approach is then evaluated by using real trending data of low methane compressor. A comparative study of the predicted results obtained from CART and ANFIS models is also carried out to appraise the prediction capability of these models. The results show that the ANFIS prediction model can track the change in machine conditions and has the potential for using as a tool to machine fault prognosis.
Resumo:
With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.
Resumo:
This article describes an exercise in collective narrative practice, built around the metaphor of adventure. This metaphor helped to scaffold the development of stories of personal agency for a group of Australian primary school children whose teachers were afraid they might be traumatised by events which occurred during a school excursion. During the excursion, the group of 110 Year 5 and 6 school children had their accommodation broken into on two separate occasions and various belongings stolen. The very brief period made available for ‘debriefing’ was used to introduce the metaphor of adventure, and open up space for the children to begin constructing a story in which they were ‘powerful’, as an alternative to the story of powerlessness and victimhood in which they were initially caught up.
Resumo:
In fault detection and diagnostics, limitations coming from the sensor network architecture are one of the main challenges in evaluating a system’s health status. Usually the design of the sensor network architecture is not solely based on diagnostic purposes, other factors like controls, financial constraints, and practical limitations are also involved. As a result, it quite common to have one sensor (or one set of sensors) monitoring the behaviour of two or more components. This can significantly extend the complexity of diagnostic problems. In this paper a systematic approach is presented to deal with such complexities. It is shown how the problem can be formulated as a Bayesian network based diagnostic mechanism with latent variables. The developed approach is also applied to the problem of fault diagnosis in HVAC systems, an application area with considerable modeling and measurement constraints.
Resumo:
Diesel engine fuel injector faults can lead to reduced power, increased fuel consumption and greater exhaust emission levels and if left unchecked, can eventually lead to premature engine failure. This paper provides an overview of the Diesel, or compression ignition combustion process, and of the two basic fuel injector nozzle designs used in Diesel engines, namely, the pintle-type and hole-type nozzles. Also described are some common faults associated with these two types of fuel injector nozzles and the techniques previously used to experimentally simulate these faults. This paper also presents a recent experimental campaign undertaken using two different diesel engines whereby various fuel injector nozzle faults were induced into the engines. The first series of tests was undertaken using a turbo-charged 5.9 litre; Cummins Diesel engine whist the second series of tests was undertaken using a naturally aspirated 4 cylinder, 2.216 litre, Perkins Diesel engine. Data corresponding to different injector fault conditions was captured using in-cylinder pressure, and acoustic emission transducers along with both crank-angle encoder and top-dead centre reference signals. Using averaged in-cylinder pressure signals, it was possible to qualify the severity of the faults whilst averaged acoustic emission signals were in turn, used as the basis for wavelets decomposition. Initial observations from this signal decomposition are also presented and discussed.
Resumo:
Acoustic emission has been found effective in offering earlier fault detection and improving identification capabilities of faults. However, the sensors are inherently uncalibrated. This paper presents a source to sensor paths calibration technique which can lead to diagnosis of faults in a small size multi-cylinder diesel engine. Preliminary analysis of the acoustic emission (AE) signals is outlined, including time domain, time-frequency domain, and the root mean square (RMS) energy. The results reveal how the RMS energy of a source propagates to the adjacent sensors. The findings lead to allocate the source and estimate its inferences to the adjacent sensor, and finally help to diagnose the small size diesel engines by minimising the crosstalk from multiple cylinders.
Resumo:
This study examined the psychosocial factors impacting upon the rule-following behaviour of residents of a hostel providing crisis accommodation to women who are homeless. After their arrival, residents of a women’s hostel (N = 83) completed questionnaires assessing the Theory of Planned Behaviour constructs of attitude, subjective norm, perceived behavioural control (PBC), and intentions related to rule-following while residing at the hostel. Perceived resident group norms for rule-following were assessed also. Follow-up staff evaluations of the target behaviour were completed after participants ceased their hostel residence. As expected, attitude, subjective norm, PBC, and group norm significantly predicted intention to follow hostel rules, and intention and PBC predicted rule following behaviour. As rule following is a crucial requirement for continuation of their stay, these findings can inform strategies to improve the experiences and outcomes of women’s short-term hostel stays.
Resumo:
Continuing monitoring of diesel engine performance is critical for early detection of fault developments in the engine before they materialize and become a functional failure. Instantaneous crank angular speed (IAS) analysis is one of a few non intrusive condition monitoring techniques that can be utilized for such tasks. In this experimental study, IAS analysis was employed to estimate the loading condition of a 4-stroke 4-cylinder diesel engine in a laboratory condition. It was shown that IAS analysis can provide useful information about engine speed variation caused by the changing piston momentum and crankshaft acceleration during the engine combustion process. It was also found that the major order component of the IAS spectrum directly associated with the engine firing frequency (at twice the mean shaft revolution speed) can be utilized to estimate the engine loading condition regardless of whether the engine is operating at normal running conditions or in a simulated faulty injector case. The amplitude of this order component follows a clear exponential curve as the loading condition changes. A mathematical relationship was established for the estimation of the engine power output based on the amplitude of the major order component of the measured IAS spectrum.
Resumo:
Continuing monitoring of diesel engine performance is critical for early detection of fault developments in the engine before they materialize and become a functional failure. Instantaneous crank angular speed (IAS) analysis is one of a few non intrusive condition monitoring techniques that can be utilized for such tasks. In this experimental study, IAS analysis was employed to estimate the loading condition of a 4-stroke 4-cylinder diesel engine in a laboratory condition. It was shown that IAS analysis can provide useful information about engine speed variation caused by the changing piston momentum and crankshaft acceleration during the engine combustion process. It was also found that the major order component of the IAS spectrum directly associated with the engine firing frequency (at twice the mean shaft revolution speed) can be utilized to estimate the engine loading condition regardless of whether the engine is operating at normal running conditions or in a simulated faulty injector case. The amplitude of this order component follows a clear exponential curve as the loading condition changes. A mathematical relationship was established for the estimation of the engine power output based on the amplitude of the major order component of the measured IAS spectrum.
Resumo:
Since the 1980s the locus of manufacturing and some services have moved to countries of the Global South. Liberalization of trade and investment has added two billion people to world labour supply and brought workers everywhere into intense competition with each other. Under orthodox neoliberal and neoclassical approaches free trade and open investment should benefit all countries and lead to convergence. However considerable differences in wages and working hours exist between workers of the Global North and those of the Global South. The organising question for the thesis is why workers in different countries but the same industries get different wages. Empirical evidence reviewed in the thesis shows that productivity does not explain these wage differences and that workers in some parts of the South are more productive than workers in the North. Part of the thesis examines the usefulness of explanations drawn from Marxist, institutionalist and global commodity chain approaches. There is a long established argument in Marxist and neo-Marxist writings that differences between North and South result from imperialism and the exercise of power. This is the starting point to review ways of understanding divisions between workers as the outcome of a global class structure. In turn, a fault line is postulated between productive and unproductive labour that largely replicates the division between the Global North and the Global South. Workers and their organizations need shared actions if they are to resist global competition and wage disparities. Solidarity has been the clarion of progressive movements from the Internationals of the early C19th through to the current Global Unions and International Confederation of Trade Unions (ICTU). The thesis examines how nationalism and particular interests have undermined solidarity and reviews the major implications for current efforts to establish and advance a global labour position.