970 resultados para external validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan™ and minor groove binder (MGB™) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach has been developed to determine ranitidine in paediatric samples using dried blood spots (DBS) on Guthrie cards (Whatman 903). A selective and sensitive HPLC-MS/MS assay has been developed and validated using small volumes of blood (30µl). A 6mm disc was punched from each DBS and extracted with methanolic solution of the internal standard (IS) nizatidine. This was further subjected to solid phase extraction (SPE), followed by reversed phase HPLC separation, using a XBridge™ C18 column and mobile phase 10mM ammonium acetate/methanol (98:2 v/v) with a flow rate of 0.3mL/min. This was combined with multiple reaction monitoring (MRM) mass detection using electrospray ionisation (ESI). The calibration curve for ranitidine was found linear over the range 10-500ng/mL (r=0.996). The limit of quantification (LOQ) of the method was validated at 10ng/mL. Accuracy and precision values for within and between days were

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Current prognostic factors are poor at identifying patients at risk of disease recurrence after surgery for stage II colon cancer. Here we describe a DNA microarray-based prognostic assay using clinically relevant formalin-fixed paraffin-embedded (FFPE) samples. Patients and Methods: A gene signature was developed from a balanced set of 73 patients with recurrent disease (high risk) and 142 patients with no recurrence (low risk) within 5 years of surgery. Results: The 634-probe set signature identified high-risk patients with a hazard ratio (HR) of 2.62 (P <.001) during cross validation of the training set. In an independent validation set of 144 samples, the signature identified high-risk patients with an HR of 2.53 (P <.001) for recurrence and an HR of 2.21 (P = .0084) for cancer-related death. Additionally, the signature was shown to perform independently from known prognostic factors (P <.001). Conclusion: This gene signature represents a novel prognostic biomarker for patients with stage II colon cancer that can be applied to FFPE tumor samples. © 2011 by American Society of Clinical Oncology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The speciation of chlorozincate(II) ionic liquids, prepared by mixing 1-octyl-3-methylirnidazolium chloride, [C(8)mim]Cl, and zinc(II) chloride in various molar ratios, chi zncl(2), was investigated using Raman spectroscopy and differential scanning calorimetry; the Gutmann acceptor number, which is a quantitative measure of Lewis acidity, was also determined as a function of the composition. These results were combined with literature data to define the anionic speciation; in the neat liquid phase, the existence of cl(-), [ZnCl4](2-), [Zn2Cl6](2-), [Zn3Cl8](2-), and [Zn4Cl10](2-) anions was confirmed. From two chlorozincate(H) ionic liquids with [C(2)mim](+) cations (chi zncl(2) = 0.33 and chi zncl(2) = 0.50), crystals have been obtained, revealing the structures of [C(2)mim)(2)[ZnCl4] and [C(2)mim](2)[Zn2Cl6] forming three-dimensional hydrogen-bond networks. The compound [C(2)mim](2){Zn4Cl10} was crystallized from the chi zncl(1) = 0.75 composition, showing an open-framework structure, with the first example of zinc in a trigonal-bipyramidal chloride coordination. Reinvestigation of the electrospray ionization mass spectrometry of these systems demonstrated that it is an unreliable technique to study liquid-phase speciation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme employing an external axial magnetic field is proposed to diagnose the intrinsic divergence of laser-generated fast electron beams, and this is studied numerically with hybrid simulations. The maximum beam radius of fast electrons increases with the initial divergence and decreases with the amplitude of the axial magnetic field. It is indicated that the intrinsic divergence of fast electrons can be inferred from measurements of the beam radius at different depth under the axial field. The proposed scheme here may be useful for future fast ignition experiments and in other applications of laser-generated fast electron beams. (C) 2011 American Institute of Physics. [doi:10.1063/1.3630925]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the results of computational fluid dynamics simulations of flow, temperature, and concentration distributions used in the design of a microreactor for the high-throughput screening of catalytic coatings (Mies et al., Chem. Eng. J. 2004, 101, 225) are compared with experimental data, and good agreement is obtained in all cases. The experimental results on flow distribution were obtained from laser Doppler anemometry measurements in the range of Reynolds numbers from 6 to 113. The measured flow nonuniformity in the separate reactor compartments was below 2%. The temperature distribution was obtained from thermocouple measurements. The temperature nonuniformity between the reactor compartments was below 3 K at a maximum heat production rate of 1.3 W in ethylene oxidation at 425 degrees C over CuO/Al2O3/Al coatings. With respect to concentration gradients, a deviation from the average rate of reaction of only 2.3% was obtained at realistic process conditions in the ethylene ammoxidation process over identical Co-ZSM-5 coatings in all reactor compartments. The cross talking noise between separate compartments does not exceed 0.1% when the reactor parts have a smooth surface finish. This illustrates the importance of ultraprecision machining of surfaces in microtechnology, when interfaces cannot be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitive and specific enzyme-linked immunosorbent assays (ELISAs) were developed for the detection of two illegal synthetic dyes: Methyl Yellow (MY) and Rhodamine B (RB) in food. Polyclonal antibodies were raised against synthesised immunogens and employed in unique direct disequilibrium ELISAs. The time of the assays was only twenty minutes (five minutes for each incubation step with sample and enzyme conjugate and ten minutes with enzyme substrate). The IC50 for MY was in the range 1.4-4.2 ng mL(-1) and for RB 0.1-0.5 ng mL(-1). A simple sample preparation method was developed for the analysis of a range of sauces. In the case of spices a dispersive solid phase extraction was applied to purify the extracts. The testing of twenty samples took approximately one and a half hours (including sample preparation and analysis). Both assays were validated according to the Commission Decision 2002/657/EC criteria for use in sauces and spices. The detection capability for MY in sauces and spices was determined to be less than 15 ng g(-1) and 50 ng g(-1), respectively and for RB, 10 ng g(-1) for both types of food samples. The precision of the developed assays was determined in a repeatability study. The intra-and inter-assay coefficients of variation were less than 25% for both tests and matrix types. The simplicity and performance of both assays indicate that they will be very reliable screening methods for the detection of the illegal dyes MY and RB in a range of food products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is described for the quantitative confirmation of halofuginone (HFG) residues in chicken liver and eggs. This method is based on LC coupled to positive ion electrospray MS-MS of the tissue extracts, prepared by trypsin digestion of the tissues followed by liquid-liquid extraction and final clean-up using Solid Phase Extraction (SPE). The [M+H](+) ion at m/z 416 is monitored along with four transitions at m/z 398, 138, 120 and 100. The method has been validated according to the draft EU criteria for the analysis of veterinary drug residues at 15, 30 and 45 mug kg (-1) in liver and 5, 15 and 50 mug kg (-1) in eggs. The new analytical limits, CCalpha and CCbeta were calculated for liver and were 35.4 and 43.6 mug kg (-1), respectively. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zeranol, an oestrogenic growth promoter in food animals, is banned within the European Union (EU). However, commercially available immunoassay kits for zeranol cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the validation of a specificity enhanced, rapid dry reagent time-resolved fluoroimmunoassay (TR-FIA) for zeranol (recovery 99%, limit of detection 1.3 ng ml(-1)) demonstrating that up to 150 ng ml(-1) of Fusarium spp. toxins in urine do not lead to false-positive results. This assay will assist EU Member States to implement Council Directive 961 23\EC, which requires states to monitor for potential abuses of zeranol. A similar TR-FIA for the Fusarium spp. toxin a-zearalenol, using the same sample extract, is also described (recovery 68%, limit of detection 5.6 ng ml(-1)). Only the addition of diluted sample extract is required to perform these dry-reagent TR-FIAs, the results being available within 1 h of extract application. The EU-funded project 'Natural Zeranol' (FAIR5-CT97-3443) will use these fluoroimmunoassays to screen bovine urine in four Member States to gather data on the seasonality of Fusarium spp. toxin contamination of urine and the incidence of zeranol screening test positives.