916 resultados para digital terrain analysis
Resumo:
Objective. Pixel intensity values (PI) and fractal dimensions (FD) were compared in selected mandibular regions on digital panoramic images of normal, osteopenic, and osteoporotic perimenopausal and postmenopausal women to evaluate their relative efficacies in detecting osteoporotic-associated bone density changes.Study design. Standardized mandibular angle, body, and canine/premolar (C/PM) regions on 54 charge-coupied device (CCD) digital panoramic images of normal and potentially osteoporotic postmenopausal women were analyzed for PI and FD. Lumbar spine and femoral neck dual-energy x-ray absorptiometry QXA) on each patient served as the reference standard examination. Pearson correlation coefficients and analysis of variance (ANOVA) were performed.Results. There was significant correlation among PI measurements (P < 0.01), and no significant correlation between FD. C/PM had significantly lower PI than control C/PM (P = 0.049).Conclusions. Osteoporotic changes in mandibular C/PM cancellous bone were detected in our study population on CCD digital panoramic images by using a robust image analysis paradigm. Future automated application of such image analysis could enable widespread, cost effective screening for osteoporosis in dental settings.
Resumo:
Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.
Resumo:
P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing image, calculation, subtract, and new document tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.
Resumo:
The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Concern regarding hydrological resources has been a theme of growing importance in Brazil, associating the development of new management policies and maintenance of natural areas related to rivers. An efficient way to maintain natural areas around rivers has been the development of greenways, and some cites have already adopted specific legislation in this respect. Following this growing evolution in the treatment of hydrological resources, this study was carried out to demarcate a greenway along the Corumbatai River in the state of São Paulo, Using multi-criteria analysis in a GIS environment. First, thematic maps were elaborated based on Landsat 7 satellite, aerial photographs and digital topographic base, Supported by field activities. With the use of multi-criteria analysis, for which ad hoe consultations were conducted to attribute weights to the thematic maps, a suitability map was elaborated for the allocation of the greenway. Sites that should be included in the greenway were also selected, such as areas appropriate for leisure activities, and ecologically important areas. Based on the suitability map, a pathway analysis was done, connecting the relevant points of interest, thus generating a greenway that runs along the Corumbatai River, with the aim of contributing to the conservation of this important hydrological resource. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Reliable spectral analysis is only achieved if the spectrum is thoroughly investigated in regard to all hidden and overlapped peaks. This paper describes the steps undertaken to find and separate such peaks in the range of 3000 to 4000 cm(-1) in the case of three different infrared absorption spectra of the glass surface of hydrolyzed silica optical fibers. Peak finding was done by the analysis of the second and fourth derivatives of the digital data, coupled with the available knowledge of infrared spectroscopy of silica-water interaction in the investigated range. Peak separation was accomplished by curve fitting with four different models. The model with the best fit was described by a sum of pure Gaussian peaks. Shoulder limit and detection limit maps were used to validate the revealed spectral features.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O objetivo deste estudo foi avaliar a influência do cetoprofeno sobre o processo de reparação óssea em tíbias de ratos, por meio da análise da densidade óptica digital. Vinte ratos da linhagem Wistar foram divididos em 2 grupos: um grupo controle (sem tratamento) e um grupo tratado com cetoprofeno. Os procedimentos experimentais consistiram de: anestesia, cirurgia, administração do cetoprofeno e exame radiográfico. As imagens radiográficas foram adquiridas empregando-se o sensor digital Visualix GX-S-HDI™ e um aparelho de raios X. As radiografias foram realizadas nos períodos baseline (inicial), 7, 14, 21 e 30 dias pós-operatório, sendo a densidade óptica (DO) avaliada por meio do sistema Vix winTM 1.4. Os valores médios da leitura da do obtidos foram analisados estatisticamente por meio de ANOVA e teste de Tukey com nível de significância de 5%. No grupo controle, houve diferença estatisticamente significante (p=0,001) entre o tempo e a DO, enquanto no grupo tratado com cetoprofeno a diferença não foi estatisticamente significante (p=0,100). O grupo controle apresentou as menores proporções de do (%) no 1º e 7º dias e as maiores proporções de do (%) no 14º, 21º e 30º dias, com diferença estatisticamente significante (p=0,001). Não houve diferença estatisticamente significante (p=0,100) entre as proporções médias de do (%) no grupo tratado, independentemente do período de avaliação. Os achados deste trabalho sugerem que houve influência do cetoprofeno sobre o processo de reparo ósseo, uma vez que na primeira semana o medicamento proporcionou aumento na densidade óptica e provocou atraso na neoformação óssea após o 21º dia.
Resumo:
Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.
Resumo:
Grinding is a finishing process in machining operations, and the topology of the grinding tool is responsible for producing the desired result on the surface of the machined material The tool topology is modeled in the dressing process and precision is therefore extremely important This study presents a solution in the monitoring of the dressing process, using a digital signal processor (DSP) operating in real time to detect the optimal dressing moment To confirm the monitoring efficiency by DSP, the results were compared with those of a data acquisition system (DAQ) and offline processing The method employed here consisted of analyzing the acoustic emission and electrical power signal by applying the DPO and DPKS parameters The analysis of the results allowed us to conclude that the application of the DPO and DPKS parameters can be substituted by processing of the mean acoustic emission signal, thus reducing the computational effort
Resumo:
Grinding process is usually the last finishing process of a precision component in the manufacturing industries. This process is utilized for manufacturing parts of different materials, so it demands results such as low roughness, dimensional and shape error control, optimum tool-life, with minimum cost and time. Damages on the parts are very expensive since the previous processes and the grinding itself are useless when the part is damaged in this stage. This work aims to investigate the efficiency of digital signal processing tools of acoustic emission signals in order to detect thermal damages in grinding process. To accomplish such a goal, an experimental work was carried out for 15 runs in a surface grinding machine operating with an aluminum oxide grinding wheel and ABNT 1045 e VC131 steels. The acoustic emission signals were acquired from a fixed sensor placed on the workpiece holder. A high sampling rate acquisition system at 2.5 MHz was used to collect the raw acoustic emission instead of root mean square value usually employed. In each test AE data was analyzed off-line, with results compared to inspection of each workpiece for burn and other metallurgical anomaly. A number of statistical signal processing tools have been evaluated.