908 resultados para dialysis dose


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80 kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100 kg with 80 kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50 kg; groups 2-6: 51-100 kg, decadally increasing) were compared. CNR was higher in patients weighing less than 60 kg than in the BW groups 71-99 kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P = 0.165-0.605), noise (P = 0.063), and image quality (P = 0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R = -0.585), BSA (R = -0.582), cross-sectional area (R = -0.544), and anteroposterior diameter of the chest (R = -0.457; P < 0.001 all parameters). We conclude that 80 kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100 kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CTA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1 years) imaged with CR and LSDR within a mean time interval of 2.8 days +/- 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with CR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To test the hypothesis that reduced responsiveness to adrenocorticotropin (ACTH) stimulation before elective major abdominal surgery is associated with an increased incidence of postoperative complications. METHODS: A low-dose (1 microg) ACTH test was performed the day before surgery, during the operation, on the first postoperative day, and before discharge from the hospital in 77 patients undergoing major abdominal surgery (age 62 [47;69] yrs [median, quartiles]; 30 female). Thirty-one patients undergoing minor, non-abdominal surgery (mostly inguinal hernia repair) (age 57 [40;66] yrs; 14 female) served as controls with minor surgical stress. A stimulated plasma cortisol concentration >or=500 nmol/l or an increment of >or=200 nmol/l in response to 1 microg ACTH was defined as normal. Scores for surgical stress and comprehensive risk, postoperative complications, and length of hospital stay (LOS) were assessed. RESULTS: On the day before major abdominal surgery, basal and stimulated plasma cortisol were 242 (165;299) nmol/l and 497 (404;568) nmol/l, respectively. Eighteen (23%) patients had an abnormal ACTH test, and 7 of these (39%) had complications versus 25 (42%) of the 59 patients with normal ACTH tests (P = .992). Surgical stress, comprehensive risk, and intra- and postoperative basal cortisol levels were higher and the response to ACTH stimulation smaller in patients with major abdominal compared to minor surgery. The peri-operative course of ACTH responses was not associated with complications or LOS in abdominal surgery patients. CONCLUSION: In patients scheduled for abdominal surgery, pre-operatively reduced adrenal response to stimulation with 1 microg ACTH is common but not associated with postoperative complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We aimed to examine different intratumoral changes after single-dose and fractionated radiotherapy, using diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in a rat rhabdomyosarcoma model. Four WAG/Rij rats with rhabdomyosarcomas in the flanks received single-dose radiotherapy of 8 Gy, and four others underwent fractionated radiotherapy (five times 3 Gy). In rats receiving single-dose radiotherapy, a significant perfusion decrease was found in the first 2 days post-treatment, with slow recuperation afterwards. No substantial diffusion changes could be seen; tumor growth delay was 12 days. The rats undergoing fractionated radiotherapy showed a similar perfusion decrease early after the treatment. However, a very strong increase in apparent diffusion coefficient occurred in the first 10 days; growth delay was 18 days. DW-MRI and DCE-MRI can be used to show early tumoral changes induced by radiotherapy. Single-dose and fractionated radiotherapy induce an immediate perfusion effect, while the latter induces more intratumoral necrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Airborne particles entering the respiratory tract may interact with the apical plasma membrane (APM) of epithelial cells and enter them. Differences in the entering mechanisms of fine (between 0.1 μm and 2.5 μm) and ultrafine ( ≤ 0.1 μm) particles may be associated with different effects on the APM. Therefore, we studied particle-induced changes in APM surface area in relation to applied and intracellular particle size, surface and number. Methods Human pulmonary epithelial cells (A549 cell line) were incubated with various concentrations of different sized fluorescent polystyrene spheres without surface charge (∅ fine – 1.062 μm, ultrafine – 0.041 μm) by submersed exposure for 24 h. APM surface area of A549 cells was estimated by design-based stereology and transmission electron microscopy. Intracellular particles were visualized and quantified by confocal laser scanning microscopy. Results Particle exposure induced an increase in APM surface area compared to negative control (p < 0.01) at the same surface area concentration of fine and ultrafine particles a finding not observed at low particle concentrations. Ultrafine particle entering was less pronounced than fine particle entering into epithelial cells, however, at the same particle surface area dose, the number of intracellular ultrafine particles was higher than that of fine particles. The number of intracellular particles showed a stronger increase for fine than for ultrafine particles at rising particle concentrations. Conclusion This study demonstrates a particle-induced enlargement of the APM surface area of a pulmonary epithelial cell line, depending on particle surface area dose. Particle uptake by epithelial cells does not seem to be responsible for this effect. We propose that direct interactions between particle surface area and cell membrane cause the enlargement of the APM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Nursing in 'live islands' and routine high dose intravenous immunoglobulins after allogeneic hematopoietic stem cell transplantation were abandoned by many teams in view of limited evidence and high costs. METHODS: This retrospective single-center study examines the impact of change from nursing in 'live islands' to care in single rooms (SR) and from high dose to targeted intravenous immunoglobulins (IVIG) on mortality and infection rate of adult patients receiving an allogeneic stem cell or bone marrow transplantation in two steps and three time cohorts (1993-1997, 1997-2000, 2000-2003). RESULTS: Two hundred forty-eight allogeneic hematopoetic stem cell transplantations were performed in 227 patients. Patient characteristics were comparable in the three cohorts for gender, median age, underlying disease, and disease stage, prophylaxis for graft versus host disease (GvHD) and cytomegalovirus constellation. The incidence of infections (78.4%) and infection rates remained stable (rates/1000 days of neutropenia for sepsis 17.61, for pneumonia 6.76). Cumulative incidence of GvHD and transplant-related mortality did not change over time. CONCLUSIONS: Change from nursing in 'live islands' to SR and reduction of high dose to targeted IVIG did not result in increased infection rates or mortality despite an increase in patient age. These results support the current practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A decision support system based on a neural network approach is proposed to advise on insulin regime and dose adjustment for type 1 diabetes patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synergism/antagonism between interleukin (IL)-1beta and parathyroid hormone (PTH) has been the subject of in vitro and in vivo work, but a possible direct action of the cytokine on PTH release has not been reported. We have investigated the effect of a continuous infusion of human recombinant IL-1beta (rIL-1beta) on circulating PTH during a 14-day period in 7-week-old female rats. This time interval was chosen in order to exclude initial hypercalcemia and to enable data collection under steady-state conditions. Five groups of 20 animals each had miniosmotic pumps (Alzet 2002, 200 microl) implanted subcutaneously and primed to release either distilled water (controls) or 100, 500, 1,000 and 2, 000 ng/24 h of rIL-1beta. Blood was drawn on days 1 and 14 for PTH, corticosterone and Ca2+ determinations. Adequate biological activity of the infused rIL-1beta was supported by elevated rectal temperature records and significant elevations of plasma corticosterone on day 14. The 100-ng dose had no effect but 500-2, 000 ng rIL-1beta/24 h significantly reduced plasma PTH in a dose-dependent manner down to 54% of basal value (20.4 +/- 1.1 vs. 15.3 +/- 1.4 pg/ml for 500 ng, p < 0.005; 20.5 +/- 1.3 vs 12.3 +/- 1.1 for 1,000 ng, p < 0.001, and 19.5 +/- 2.0 vs. 10.6 +/- 1.1 pg/ml for 2,000 ng, p < 0.0008). Despite these findings, no differences in blood Ca2+ could be detected between treated animals and controls. The following conclusions can be inferred from the foregoing: Systemic administration of rIL-1beta to rats induced a dose-dependent fall in circulating PTH without altering calcemia, calling into question the biological relevance of the former finding. Although the recorded PTH depression may indeed not have been severe enough to cause hypocalcemia, it can be hypothesized that osteoclast activation by rIL-1beta would enhance bone mineral release into the pool compensating for depressed PTH activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the modulation of the nociceptive withdrawal reflex (NWR) and temporal summation (TS) by low-dose acepromazine (ACP) in conscious dogs. To assess the short- and long-term stability of the reflex thresholds. STUDY DESIGN: Randomized, blinded, placebo-controlled cross-over experimental study. ANIMALS: Eight adult male Beagles. METHODS: The NWR was elicited using single transcutaneous electrical stimulation of the ulnar nerve. Repeated stimuli (10 pulses, 5 Hz) were applied to evoke TS. The responses of the deltoideus muscle were recorded and quantified by surface electromyography and the behavioural reactions were scored. Each dog received 0.01 mg kg(-1) ACP or an equal volume saline intravenously (IV) at 1 week intervals. Measurements were performed before (baseline) and 20, 60 and 100 minutes after drug administration. Sedation was scored before drug administration and then at 10 minutes intervals. Data were analyzed with Friedman repeated measures analysis of variance on ranks and Wilcoxon signed rank tests. RESULTS: Acepromazine resulted in a mild tranquilization becoming obvious at 20 minutes and peaking 30 minutes after injection. Single (I(t)) and repeated stimuli (TS(t)) threshold intensities, NWR and TS characteristics and behavioural responses were not affected by the ACP at any time point. Both I(t) and TS(t) were stable over time. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, 0.01 mg kg(-1) ACP IV had no modulatory action on the NWR evoked by single or repeated stimuli, suggesting no antinociceptive activity on phasic nociceptive stimuli. The evidence of the stability of the NWR thresholds supports the use of the model as an objective tool to investigate nociception in conscious dogs. A low dose of ACP administered as the sole drug, can be used to facilitate the recordings in anxious subjects without altering the validity of this model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study quantitatively investigated the analgesic action of a low-dose constant-rate-infusion (CRI) of racemic ketamine (as a 0.5 mg kg(-1) bolus and at a dose rate of 10 microg kg(-1) min(-1)) in conscious dogs using a nociceptive withdrawal reflex (NWR) and with enantioselective measurement of plasma levels of ketamine and norketamine. Withdrawal reflexes evoked by transcutaneous single and repeated electrical stimulation (10 pulses, 5 Hz) of the digital plantar nerve were recorded from the biceps femoris muscle using surface electromyography. Ketamine did not affect NWR thresholds or the recruitment curves after a single nociceptive stimulation. Temporal summation (as evaluated by repeated stimuli) and the evoked behavioural response scores were however reduced compared to baseline demonstrating the antinociceptive activity of ketamine correlated with the peak plasma concentrations. Thereafter the plasma levels at pseudo-steady-state did not modulate temporal summation. Based on these experimental findings low-dose ketamine CRI cannot be recommended for use as a sole analgesic in the dog.