996 resultados para body schema


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human body is an extremely challenging environment for the operation of wireless communications systems, not least because of the complex antenna-body electromagnetic interaction effects which can occur. This is further compounded by the impact of movement and the propagation characteristics of the local environment which all have an effect upon body centric communications channels. As the successful design of body area networks (BANs) and other types of body centric system is inextricably linked to a thorough understanding of these factors, the aim of this paper is to conduct a survey of the current state of the art in relation to propagation and channel models primarily for BANs but also considering other types of body centric communications. We initially discuss some of the standardization efforts performed by the Institute of Electrical and Electronics Engineers 802.15.6 task group before focusing on the two most popular types of technologies currently being considered for BANs, namely narrowband and Ultrawideband (UWB) communications. For narrowband communications the applicability of a generic path loss model is contended, before presenting some of the scenario specific models which have proven successful. The impacts of human body shadowing and small-scale fading are also presented alongside some of the most recent research into the Doppler and time dependencies of BANs. For UWB BAN communications, we again consider the path loss as well as empirical tap delay line models developed from a number of extensive channel measurement campaigns conducted by research institutions around the world. Ongoing efforts within collaborative projects such as Committee on Science and Technology Action IC1004 are also described. Finally, recent years have also seen significant developments in other areas of body centric communications such as off-body and body-to-body communications. We highlight some of the newest relevant research in these areas as well as discussing some of the advanced topics which are currently being addressed in the field of body centric communications. Key Points Channel models for body centric comms ©2014. The Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shape memory NiTi alloys have been used extensively for medical device applications such as orthopedic, dental, vascular and cardiovascular devices on account of their unique shape memory effect (SME) and super-elasticity (SE). Laser welding is found to be the most suitable method used to fabricate NiTi-based medical components. However, the performance of laser-welded NiTi alloys under corrosive environments is not fully understood and a specific focus on understanding the corrosion fatigue behaviour is not evident in the literature. This study reveals a comparison of corrosion fatigue behaviour of laser-welded and bare NiTi alloys using bending rotation fatigue (BRF) test which was integrated with a specifically designed corrosion cell. The testing environment was Hanks’ solution (simulated body fluid) at 37.5oC. Electrochemical impedance spectroscopic (EIS) measurement was carried out to monitor the change of corrosion resistance at different periods during the BRF test. Experiments indicate that the laser-welded NiTi alloy would be more susceptible to the corrosion fatigue attack than the bare NiTi alloy. This finding can serve as a benchmark for the product designers and engineers to determine the factor of safety of NiTi medical devices fabricated using laser welding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wear and corrosion of metal-on-metal hip replacements results in wear debris and metal-ion release in vivo, which may subsequently cause pain and hypersensitivity for patients. Retrieved metal-on-metal hip replacements have revealed that two-body sliding wear and three-body abrasive wear are the predominant wear mechanisms. However, there is a lack of understanding of the combined effects of wear/corrosion, especially the effect of abrasion-corrosion.

This study investigates the sliding-corrosion and abrasion-corrosion performance of a cast CoCrMo alloy in simulated hip joint environments using a microabrasion rig integrated with an electrochemical cell. Tests have been conducted in 0.9% NaCl, phosphate buffered saline solution, 25% and 50% bovine serum solutions with 0 or 1 g cm(-3) SiC at 37 degrees C. Experimental results reveal that under abrasion-corrosion test conditions, the presence of proteins increased the total specific wear rate. Conversely, electrochemical noise measurements indicated that the average anodic current levels were appreciably lower for the proteinaceous solutions when compared with the inorganic solutions. A severely deformed nanocrystalline layer was identified immediately below the worn surface for both proteinaceous and inorganic solutions. The layer is formed by a recrystallisation process and/or a strain-induced phase transformation that occurs during microabrasion-corrosion. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The abrasion seen on some of the retrieved CoCrMo hip joints has been reported to be caused by entrained hard particles in vivo. However, little work has been reported on the abrasion mechanisms of CoCrMo alloy in simulated body environments. Therefore. this study covers the mapping of micro-abrasion wear mechanisms of cast CoCrMo induced by third body hard particles under a wide range of abrasive test conditions. This study has a specific focus on covering the possible in vivo wear modes seen on metal-on-metal (MoM) surfaces. Nano-indentation and nano-scratch tests were also employed to further investigate the secondary wear mechanisms-nano-scale material deformation that involved in micro-abrasion processes. This work addresses the potential detrimental effects of third body hard particles in vivo such as increased wear rates (debris generation) and corrosion (metal-ion release). The abrasive wear mechanisms of cast CoCrMo have been investigated under various wear-corrosion conditions employing two abrasives, SiC (similar to 4 mu m) and Al(2)O(3) (similar to 1 mu m), in two test solutions, 0.9% NaCl and 25% bovine serum. The specific wear rates, wear mechanisms and transitions between mechanisms are discussed in terms of the abrasive size, volume fraction and the test solutions deployed. The work shows that at high abrasive volume fractions, the presence of protein enhanced the wear loss due to the enhanced particle entrainment, whereas at much lower abrasive volume fractions, protein reduced the wear loss by acting as a boundary lubricant or rolling elements which reduced the abrasivity (load per particle) of the abrasive particles. The abrasive wear rate and wear mechanisms of the CoCrMo are dependent on the nature of the third body abrasives, their entrainment into the contact and the presence of the proteins. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study focuses on the effect of the material type and the lubricant on the abrasive wear behaviour of two important commercially available ceramic on ceramic prosthetic systems, namely, Biolox(R) forte and Bioloxl(R) delta (CeramTec AG, Germany). A standard microabrasion wear apparatus was used to produce '3-body' abrasive wear scars with three different lubricants: ultrapure water, 25 vol% new-born calf serum solution and 1 wt% carboxymethyl cellulose sodium salt (CMC-Na) solution. 1 mu m alumina particles were used as the abrasive. The morphology of the wear scar was examined in detail using Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM). Subsurface damage accumulation was investigated by Focused Ion Beam (FIB) cross-sectional milling and Transmission Electron Microscopy (TEM). The effect of the lubricant on the '3-body' abrasive wear mechanisms is discussed and the effect of material properties compared. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some retrieved CoCrMo hip implants have shown that abrasive wear is one of the possible wear mechanisms invoked within such joints. To date, little work has focused on the third body abrasion of CoCrMo and therefore there is a general lack of understanding of the effect of abrasive size and volume concentration on the tribo-corrosion performance of the CoCrMo alloys. The present work assessed the tribo-corrosion behaviour of cast CoCrMo (F-75) under various abrasion-corrosion conditions by using a modified microabrasion tester incorporating a three-electrode electrochemical cell. The effects of reduced abrasive size/hardness and volume concentration, as well as the role of proteins on the tribo-corrosion performance of the cast CoCrMo alloy were addressed. The correlation between electrochemical and mechanical processes for different abrasion-corrosion test conditions has been discussed in detail. Results show that the reduction in abrasive size and volume concentration can significantly affect the abrasion-corrosion wear mechanisms and the wear-induced corrosion response of the material. The finding of this study implies that the smaller/softer third body particles generated in vivo could also result in significant wear-induced corrosion and therefore potential metal ion release, which could be potentially detrimental to both the patient health and the life span of the implants. © 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we compare a number of the classical models used to characterize fading in body area networks (BANs) with the recently proposed shadowed ț–ȝ fading model. In particular, we focus on BAN channels which are considered to be susceptible to shadowing by the human body. The measurements considered in this study were conducted at 2.45 GHz for hypothetical BAN channels operating in both anechoic and highly reverberant environments while the person was moving. Compared to the Rice, Nakagami and lognormal fading models, it was found that the recently proposed shadowed ț௅μ fading model provided an enhanced fit to the measured data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using device-to-device communications as an underlay for cellular communications will provide an exciting opportunity to increase network capacity as well as improving spectral efficiency. The unique geometry of device-to-device links, where user equipment is often held or carried at low elevation and in close proximity to the human body, will mean that they are particularly susceptible to shadowing events caused not only by the local environment but also by the user's body. In this paper, the shadowed κ - μ fading model is proposed, which is capable of characterizing shadowed fading in wireless communication channels. In this model, the statistics of the received signal are manifested by the clustering of multipath components. Within each of these clusters, a dominant signal component with arbitrary power may exist. The resultant dominant signal component, which is formed by the phasor addition of these leading contributions, is assumed to follow a Nakagami- m distribution. The probability density function, moments, and the moment-generating function are also derived. The new model is then applied to device-to-device links operating at 868 MHz in an outdoor urban environment. It was found that shadowing of the resultant dominant component can vary significantly depending upon the position of the user equipment relative to the body and the link geometry. Overall, the shadowed κ - μ fading model is shown to provide a good fit to the field data as well as providing a useful insight into the characteristics of the received signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The association between body size and head and neck cancers (HNCA) is unclear, partly because of the biases in case–control studies. Methods: In the prospective NIH–AARP cohort study, 218,854 participants (132,288 men and 86,566 women), aged 50 to 71 years, were cancer free at baseline (1995 and 1996), and had valid anthropometric data. Cox proportional hazards regression was used to examine the associations between body size and HNCA, adjusted for current and past smoking habits, alcohol intake, education, race, and fruit and vegetable consumption, and reported as HR and 95% confidence intervals (CI). Results: Until December 31, 2006, 779 incident HNCAs occurred: 342 in the oral cavity, 120 in the oro- and hypopharynx, 265 in the larynx, 12 in the nasopharynx, and 40 at overlapping sites. There was an inverse association between HNCA and body mass index, which was almost exclusively among current smokers (HR = 0.76 per each 5 U increase; 95% CI, 0.63–0.93), and diminished as initial years of follow-up were excluded. We observed a direct association with waist-to-hip ratio (HR = 1.16 per 0.1 U increase; 95% CI, 1.03–1.31), particularly for cancers of the oral cavity (HR, 1.40; 95% CI, 1.17–1.67). Height was also directly associated with total HNCAs (P = 0.02), and oro- and hypopharyngeal cancers (P < 0.01). Conclusions: The risk of HNCAs was associated inversely with leanness among current smokers, and directly with abdominal obesity and height. Impact: Our study provides evidence that the association between leanness and risk of HNCAs may be due to effect modification by smoking. Cancer Epidemiol Biomarkers Prev; 23(11); 2422–9. ©2014 AACR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The effect of dietary sucrose on insulin resistance and the pathogenesis of diabetes and vascular disease is unclear. We assessed the effect of 5% versus 15% sucrose intakes as part of a weight maintaining, eucaloric diet in overweight/obese subjects.

METHODS: Thirteen subjects took part in a randomised controlled crossover study (M:F 9:4, median age 46 years, range 37-56 years, BMI 31.7±0.9 kg/m(2)). Subjects completed two 6 week dietary periods separated by 4 week washout. Diets were designed to have identical macronutrient profile. Insulin action was assessed using a two-step hyperinsulinaemic euglycaemic clamp; glucose tolerance, vascular compliance, body composition and lipid profiles were also assessed.

RESULTS: There was no change in weight or body composition between diets. There was no difference in peripheral glucose utilization or suppression of endogenous glucose production. Fasting glucose was significantly lower after the 5% diet. There was no demonstrated effect on lipid profiles, blood pressure or vascular compliance.

CONCLUSION: A low-sucrose diet had no beneficial effect on insulin resistance as measured by the euglycaemic glucose clamp. However, reductions in fasting glucose, one hour insulin and insulin area under the curve with the low sucrose diet on glucose tolerance testing may indicate a beneficial effect and further work is required to determine if this is the case. Clinical Trial Registration number ISRCTN50808730.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the importance of laughter in social interactions it remains little studied in affective computing. Respiratory, auditory, and facial laughter signals have been investigated but laughter-related body movements have received almost no attention. The aim of this study is twofold: first an investigation into observers' perception of laughter states (hilarious, social, awkward, fake, and non-laughter) based on body movements alone, through their categorization of avatars animated with natural and acted motion capture data. Significant differences in torso and limb movements were found between animations perceived as containing laughter and those perceived as nonlaughter. Hilarious laughter also differed from social laughter in the amount of bending of the spine, the amount of shoulder rotation and the amount of hand movement. The body movement features indicative of laughter differed between sitting and standing avatar postures. Based on the positive findings in this perceptual study, the second aim is to investigate the possibility of automatically predicting the distributions of observer's ratings for the laughter states. The findings show that the automated laughter recognition rates approach human rating levels, with the Random Forest method yielding the best performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The propagation of UWB signals for body-centric communications within a modern classroom/conference room environment was investigated. Presented results demonstrate that the body-antenna mounting position has a marked impact on the received power levels and positioning the antenna on the chest as opposed to the shoulder or wrist creates more extreme values in receive power, mean excess delay and rms delay spread. Additionally, the best fit models for each scenario are presented and highlight the difference between the chest and other compared antenna locations. The work concluded that the chest is a poor choice of mounting position for the antenna due to significant body shadowing effects, with the wrist or shoulder considered better options for UWB systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single ‘baseline’ measurement and such analyses cannot account for possible changes in these which may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25–<30 kg/m2) or moderately obese (≥30–<35) tended to be associated with a lower risk of mortality compared to normal (≥18.5–<25): ESTHER, HR (95 % CI) 0.69 (0.58–0.82) and 0.78 (0.63–0.97); Rotterdam, 0.86 (0.79–0.94) and 0.80 (0.72–0.89). A similar relationship was found, but only for overweight in Glostrup, HR (95 % CI) 0.88 (0.76–1.02); and moderately obese in Tromsø, HR (95 % CI) 0.79 (0.62–1.01). Associations were not evident between repeated measures of BMI and CVD. Conversely, increasing CRP concentrations, measured on more than one occasion, were associated with an increasing risk of mortality and CVD. Being overweight or moderately obese is associated with a lower risk of mortality, while CRP, independent of BMI, is positively associated with mortality and CVD risk. If inflammation links CRP and BMI, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity.