955 resultados para angular displacement
Resumo:
Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)
Resumo:
A novel flow-tagging technique is presented which was employed to measure gas velocities in the free stream of a shock tube. This method is based on the laser spectroscopic techniques of Laser-Enhanced Ionisation (LEI) and Laser-Induced Fluorescence (LIF). The flow in the shock tube is seeded with small amounts of sodium, and LEI is used to produce a substantial depletion of neutral sodium atom concentration in a well-defined region of the flow, by using two wavelength-resonance excitation and subsequent collisional ionisation. At a specific time delay, single-laser-pulse planar LIF is utilised to produce a two-dimensional (2-D) inverse image of the depleted tagged region downstream of the flow. By measuring the displacement of the tagged region, free stream velocities in a shock tube were determined. Large variations in the concentration of sodium seeded into the flow were observed and even in the presence of these large variations accurate free-stream velocity measurements were obtained. The experimentally determined value for velocity compares very well with the predicted velocity.
Resumo:
The St. Lawrence Island polynya (SLIP) is a commonly occurring winter phenomenon in the Bering Sea, in which dense saline water produced during new ice formation is thought to flow northward through the Bering Strait to help maintain the Arctic Ocean halocline. Winter darkness and inclement weather conditions have made continuous in situ and remote observation of this polynya difficult. However, imagery acquired from the European Space Agency ERS-1 Synthetic Aperture Radar (SAR) has allowed observation of the St. Lawrence Island polynya using both the imagery and derived ice displacement products. With the development of ARCSyM, a high resolution regional model of the Arctic atmosphere/sea ice system, simulation of the SLIP in a climate model is now possible. Intercomparisons between remotely sensed products and simulations can lead to additional insight into the SLIP formation process. Low resolution SAR, SSM/I and AVHRR infrared imagery for the St. Lawrence Island region are compared with the results of a model simulation for the period of 24-27 February 1992. The imagery illustrates a polynya event (polynya opening). With the northerly winds strong and consistent over several days, the coupled model captures the SLIP event with moderate accuracy. However, the introduction of a stability dependent atmosphere-ice drag coefficient, which allows feedbacks between atmospheric stability, open water, and air-ice drag, produces a more accurate simulation of the SLIP in comparison to satellite imagery. Model experiments show that the polynya event is forced primarily by changes in atmospheric circulation followed by persistent favorable conditions: ocean surface currents are found to have a small but positive impact on the simulation which is enhanced when wind forcing is weak or variable.
Resumo:
Molecular dynamics simulations are used to study the interaction of low-energy Ar atoms with the Ni(001) surface, Angular scattering distributions, in and out of the plane of incidence, are investigated as a function of incident energy, angles of incidence, crystallographic orientation of the incident beam and surface temperature. The results show a clear transition to the structure scattering regime at around 2 eV. However, at lower energies, two sub-regimes are revealed by the simulations, Far energies up to 250 meV, scattering is mainly diffuse, and significant trapping on the surface is observed, At energies above this level, lobular patterns start to form and trapping decreases with the increase in energy, Generally, there is a weak temperature dependence, but variations in the angle of incidence and/or changes in the crystallographic direction, generate significant changes in the scattering patterns.
Resumo:
The purpose of this study was to evaluate the mid- and long-term results of percutaneous transhepatic cholangiography (PTC) and biliary drainage in children with isolated bilioenteric anastomotic stenosis (BAS) after pediatric liver transplantation. Sixty-four children underwent PTC from March 1993 to May 2008. Nineteen cholangiograms were normal; 10 showed intrahepatic biliary stenosis and BAS, and 35 showed isolated BAS. Cadaveric grafts were used in 19 and living donor grafts in 16 patients. Four patients received a whole liver, and 31 patients received a left lobe or left lateral segment. Roux-en-Y hepaticojejunostomy was performed in all patients. Indication for PTC was based on clinical, laboratory, and histopathologic findings. In patients with isolated BAS, dilation and biliary catheter placement, with changes every 2 months, were performed. Patients were separated into 4 groups according to number of treatment sessions required. The drainage catheter was removed if cholangiogram showed no significant residual stenosis and normal biliary emptying time after a minimum of 6 months. The relationship between risk factors (recipient`s weight < 10 kg, previous exposure to Cytomegalovirus, donor-recipient sex and weight relations, autoimmune disease as indication for transplantion, previous Kasai`s surgery, use of reduced liver grafts, chronic or acute rejection occurrence) and treatment was evaluated. Before PTC, fever was observed in 46%, biliary dilation in 23%, increased bilirubin in 57%, and increased gamma-glutamyltransferase (GGT) in 100% of patients. In the group with BAS, 24 of 35 (69%) patients had histopathologic findings of cholestasis as did 9 of 19 (47%) patients in the group with normal PTC. Of the 35 patients, 23 (65.7%) needed 1 (group I), 7 needed 2 (group II), 4 needed 3 (group III), and 1 needed 4 treatment sessions (group IV). The best results were observed after 1 treatment session, and the mean duration of catheter placement and replacement was 10 months. The primary patency rate was 61.2%, and the recurrence rate was 34.3% (group I). Seven patients (7 of 35; 20%) had their stricture treated with a second treatment session (group II). The average drainage time in group II was 24 months. During a period > 20 months, 4 patients (4 of 35; 11.4%) required 1 additional treatment session (group III), and 1 patient (1 of 35; 2.9%) had a catheter placed at the end of the study period (group IV). Drainage time in group I was significantly shorter than those in groups II, III, and IV (p < 0.05). There was no statistically significant relation between therapeutic response and the selected risk factors (p > 0.05). The majority of complications, such as catheter displacement and leakage, were classified as minor; however, 2 patients (5.7%) with hemobilia were noted. Complications increased according to the need for reintervention. In conclusion, balloon dilation and percutaneous drainage placement is safe and effective, and it has long-term patency for children with BAS after liver transplantation. Because of prolonged treatment time, reintervention may be necessary, thereby increasing the complication rate. Balloon dilation and percutaneous drainage placement should be considered as the first treatment option because of its minimally invasive nature.
Resumo:
The suprathermal particles, electrons and protons, coming from the magnetosphere and precipitating into the high-latitude atmosphere are an energy source of the Earth's ionosphere. They interact with ambient thermal gas through inelastic and elastic collisions. The physical quantities perturbed by these precipitations, such as the heating rate, the electron production rate, or the emission intensities, can be provided in solving the kinetic stationary Boltzmann equation. This equation yields particle fluxes as a function of altitude, energy, and pitch angle. While this equation has been solved through different ways for the electron transport and fully tested, the proton transport is more complicated. Because of charge-changing reactions, the latter is a set of two-coupled transport equations that must be solved: one for protons and the other for H atoms. We present here a new approach that solves the multistream proton/hydrogen transport equations encompassing the collision angular redistributions and the magnetic mirroring effect. In order to validate our model we discuss the energy conservation and we compare with another model under the same inputs and with rocket observations. The influence of the angular redistributions is discussed in a forthcoming paper.
Resumo:
This study aimed to compare the resting energy expenditure (REE) of white and non-white severely obese Brazilian women. REE was examined in 83 severely obese Brazilian women (n = 58 white and 25 non-white) with mean (+/- SD) age 42.99 +/- 11.35 and body mass index 46.88 +/- 6.22 kg/m(2) who were candidates for gastric bypass surgery. Body composition was assessed by air displacement plethysmography (ADP) BOD PODO body composition system (Life Measurement Instruments, Concord, CA) and REE was measured, under established protocol, with an open-circuit calorimeter (Deltatrac II MBM-200, Datex-Ohmeda, Madison, WI, USA). There was no significant difference between the REE of white and non-white severely obese women (1,953 +/- 273 and 1,906 +/- 271 kcal/d, respectively; p = 0.48). However, when adjusted for fat free mass (MLG), REE was significantly higher in non-white severely obese women (difference between groups of 158.4 kcal, p < 0.01). REE in white women was positively and significantly correlated to C-reactive protein (PCR) (r = 0.41.8; P < 0.001) and MLG (r = 0.771; P < 0.001). In the non-white women, REE was only significantly correlated to MLG (r = 0.753; P < 0.001). The multiple linear regression analysis showed that skin color, MLG and PCR were the significant determinants of REE (R(2) = 0.55). This study showed that, after adjustment for MLG, non-white severely obese women have a higher REE than the white ones. The association of body composition inflammation factors and REE in severely obese Brazilian women remains to be further investigated.
Resumo:
Background & aims: Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Methods: Severely obese subjects (83 female/36 mate, mean age = 41.6 +/- 11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman`s graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. Results: BF estimations from BIA (64.8 +/- 15 kg) and ADP (65.6 +/- 16.4 kg) did not differ (p > 0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide Limit of agreement (- 10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p < 0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Conclusions: Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment. (C) 2008 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Resumo:
Study design: Single-blind randomized, controlled clinical study. Objectives: To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Setting: Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Methods: Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. Results: There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Conclusion: Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries. Spinal Cord (2011) 49, 1001-1007; doi:10.1038/sc.2011.37; published online 3 May 2011
Resumo:
P>Background There is good evidence for the use of compression for some clinical indications but little is known about dosimetry in compression. Objective The aim of this work was to evaluate whether or not the use of compression stockings during part of the day would help in the reduction of evening oedema in patients with clinical, epidemiological, anatomical and physiopathological (CEAP) classifications C0 and C1. Methods The effects of elastic compression stockings on volumetric variations during the working day were evaluated for the legs of two men and 18 women (40 legs). The inclusion criterion was classification as C0 (10 legs) or C1 (30 legs) according to the CEAP criteria. Participants used three-quarter-length elastic compression stockings (20-30 mmHg) on three consecutive days for the entire day or only for the morning or they did not use the stockings at all. Volumetry using the water displacement technique was performed in the morning and in the evening. When the patients wore the stockings only during the morning, volumetry was also performed at 13:00 h. Results Significant increases in volume were observed for both legs when stockings were not used compared with the use of stockings in the morning only. After removing the stockings, both legs had significant increases in volume in the afternoon. However, use for half the day was better than not using the stockings at all. Conclusions The use of elastic compression stockings can reduce volumetric variations during working hours, with the use of stockings for the entire day being better than for just half the day.
Resumo:
Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)
Resumo:
Pectus excavatum is a congenital deformity that can require surgical treatment. Since Nuss proposed a correction technique, several modifications have been proposed in order to achieve more safety and efficiency in the placement and removal of both bars. Our objective is to describe the technique of placing and removing the bars by proposing three technical modifications: two in bar placement and one in the bar removal. We describe two cases where Nuss bars were placed and one case where the bar was removed as per the technical modification proposed herein. According to the original technique, bar stabilisers. were placed close to the lateral bar edges. We propose a more medial position in order to reduce bar displacement. New stabilisers were designed with central grooves in the posterior surface, which allow better sliding. The technical modification suitable for bar removal was the use of a protective film around the bars to protect the surrounding tissues from the sharp edges, and thereby minimise the risk of injuries. All the proposed modifications were performed without any additional surgical risk or perioperative complication. These three technical modifications can be easily and safety performed, and seem to reduce the risk of bleeding with no additional perioperative complications. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Resumo:
Patella stabilizer muscle response and patellar kinematics were evaluated in 19 women with anterior knee pain (AKP) and 20 healthy women during maximum voluntary isometric contraction (MVIC) with the knee positioned at 15 degrees, 30 degrees and 45 degrees flexion during open (OKC) and closed (CKC) kinetic chain exercises. Patellar kinematics was evaluated through patellar tilt and displacement, and the electrical activity of patellar stabilizers through the root mean square normalized during MVIC and OKC with the knee at 90 degrees flexion. Data revealed that the vastus medialis oblique muscle (VMO) was more active in the control group compared to the AKP group during OKC exercises with the knee at 45 degrees flexion. However, no difference in the patellar kinematics was observed between these groups; nevertheless, the correlation between these parameters also showed, with the knee at 45 degrees flexion, that lateral patellar tilt increase was associated with a reduction in the activity of lateral patellar stabilizers in the control group and with an increase in the VMO activity in the AKP group. In conclusion, electrical activity is an important factor in evaluating AKP and in AKP treatment evolution. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objective: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. Methods: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex (R)). Results: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex (R) and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex (R) screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). Conclusion: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.
Resumo:
Study design: Cross-sectional study. Objectives: To assess the importance of proprioceptive and vision information on different types of wheelchair seats with regard to postural control in paraplegic individuals during static posture. Setting: Centre of Rehabilitation at the University Hospital/FMRP-USP and Rehabilitation Outpatient Clinic at University Hospital/UNICAMP, Brazil. Methods: This study involved 11 individuals with paraplegia. All individuals were submitted to an evaluation of static balance with their eyes open and closed in three different types of seats: wheelchair seat, foam seat and gel seat. Balance evaluation was performed by using the Polhemus system, in which body displacements and anteroposterior and mediolateral speeds were assessed in a static seated position in the different types of seats. Data were analyzed using analysis of variance. The differences were considered at P<0.05. Results: No statistical differences were found between the three types of seats in terms of displacements and anteroposterior and mediolateral speeds, or between seats with individuals keeping their eyes open or closed (P>0.05). However, it was observed that body displacements were more prominent toward an anteroposterior than a mediolateral direction. Conclusion: This study suggests that individuals with paraplegia tend to exhibit a more anteroposterior body displacement than a mediolateral one, with no significant differences between the types of seats in both situations of eyes open and closed. Spinal Cord (2010) 48, 825-827; doi:10.1038/sc.2010.30; published online 30 March 2010