924 resultados para amperometric detection (L)-dopa
Resumo:
Two simple methods were developed to determine, 11 pesticides in coconut water, a natural isotonic drink rich in salts, sugars and vitamins consumed by the people and athletes. The first procedure involves solid-phase extraction using Sep-Pak Vac C-18 disposable cartridges with methanol for elution. Isocratic analysis was carried out by means of high-performance liquid chromatography with ultraviolet detection at 254 nm to analyse captan, chlorothalonil, carbendazim, lufenuron and diafenthiuron. The other procedure is based on liquid-liquid extraction with hexane-dichloromethane (1:1, v/v), followed by gas chromatographic analysis with effluent splitting to electron-capture detection for determination of endosulfan, captan, tetradifon and trichlorfon and thermionic specific detection for determination of malathion, parathion-methyl and monocrotophos. The methods were validated with fortified samples at different concentration levels (0.01-12.0 mg/kg). Average recoveries ranged from 75 to 104% with relative standard deviations between 1.4 and 11.5%. Each recovery analysis was repeated at least five times. Limits of detection ranged from 0.002 to 2.0 mg/kg. The analytical procedures were applied to 15 samples and no detectable amounts of the pesticides were found in any samples under the conditions described. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Ceftazidime is hydrolysed only slowly at pH 10 at room temperature. This is indicated by a small cathodic stripping voltammetric peak obtained at pH 10 at a hanging mercury drop electrode at about -0.6 V which corresponds to the reduction of the hydrolysis product. This peak is enhanced more than tenfold by the addition of poly-L-lysine (PLL) to the electrolyte solution. The optimum accumulation potential is between 0 and -0.1 V: the size of the peak decreases steadily, however, as the accumulation potential is moved to more negative potentials and is about one-sixth the size for accumulation at -0.4 V. Existing knowledge of the organic chemistry of cephalosporins indicates that the accumulation must involve an aminolysis reaction of the unprotonated PLL with the beta-lactam ring of the ceftazidime. The limit of detection (3 sigma) in standard solutions was calculated to be 1 x 10(-10) mol l(-1). The detection limit in buffer solution containing 1% of urine was calculated to be 5 x 10(-9) mol l(-1), i.e. 5 x 10(-6) mol l(-1) in the urine. (C) 1999 Elsevier B.V. B.V. AU rights reserved.
Resumo:
Objectives. The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer.Methods. Between July 2001 and February 2003, 56 patients with cervical cancer 1160 stage I (it 53) or stage 11 (it 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (Te-99m-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intratoperative lymphatic mapping with a handheld gamma probe, Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy, Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy.Results. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe, Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliae region, and 6.7),) in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (4100 had bilateral sentinel nodes, Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel node.,, that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% - 56.6-96.2) and the negative predictive value was 92.1% (CI 95% 78.6 98.3) the accuracy of sentinel node in predicting the lymph node status was 94.2%,Conclusion. Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with Tc-99-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection call be avoided. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The oxidation of a reactive dye, Cibacron Blue F3GA, CB, (C.I. 61211), widely used in the textile industries to color natural fibers, was studied by electrochemical techniques. The oxidation on glassy carbon electrode occurs in two steps at 2.0 < pH < 10 involving one electron transfer each to the amine group leading to the imide derivative. Stable films of poly-L-lysine (PLL) in the presence of glutaraldehyde (GA) 97.5%:2.5% on glassy carbon electrode can be used to detect low levels of dye using its oxidation peak at +0.75V by voltammetry. Linear calibration graphs were obtained for the CB reactive dye, from 1.0 X 10(-6) to 1.0 X 10(-5) mol L-1 in B-R buffer, pH 2.0, using a pre-concentration off-line during 10 min. The detection limit (3 sigma/slope) was calculated to be 4.5 X 10(-8) mol L-1. Films of PLL can readily be applied for the determination of CB dye bearing aminoanthraquinone as chromophore and chlorotriazinyl as reactive group at concentrations at least 100 times lesser than using a glassy carbon electrode without modification. The method described was applied for the determination of CB dye in tap water and raw water collected from the municipal treatment plant with a recovery of 89.2% +/- 5.4 and 88.0% +/- 6.5, respectively. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
In this article some considerations obtained during the utilization of rotor response analysis techniques in hydraulic powerplants are discussed. An applied research work was carried out in two hydraulic turbines analysing the rotor response both theoretically and experimentally. A developed mathematical model was used to simulate the rotordynamic behaviour of Francis and Kaplan turbines. The main dynamical effects that appear during the operation of the machines are discussed too. A series of measurements were carried out in the turbines using impact hammers to determine the modal behaviour of the units. The tests were carried out with the machine still and in operation. Some results and the comparison with the theory is presented in this article. The improved theoretical model was used for a sensitivity analysis of the different bearings to the main excitations that fake place during the machine operation. From this analysis, the best measuring points for condition monitoring were determined.
Resumo:
A total of 163 dogs with neuromuscular, respiratory and/or gastrointestinal disorders, was admitted at the Veterinary Hospital, Federal University of Uberlandia, Brazil, and submitted to serology for Toxoplasma gondii and Neospora caninum. Assays for T gondii included indirect haemagglutination (IHA), indirect fluorescent antibody (IFAT-Tg), immunoenzymatic (ELISA), and immunoblotting (IB-Tg). Assays for N, caninum included IFAT-Nc and immunoprecipitation (IP-Nc). Based on concordant results by three serological tests (IHA, IFAT-Tg and ELISA) for T gondii, and divergent results further confirmed by IB-Tg for reactivity to TgSAG1, the 163 sera were divided into two groups: 59 (36%) Tg-seropositive samples and 104 (64%) Tg-seronegative samples. Antibodies to Neospora were detected in 11 (6.7%) out of 163 analyzed dog sera, with 5 (3.1 %) samples reactive to both parasites (Tg+/Nc+), and 6 (3.7%) reactive only to Neospora (Tg-/Nc+). Antibodies only to T: gondii were found in 54 (33%) samples. Among the 11 Neospora-positive sera analyzed by IB-Tg, the five sera Tg+/Nc+ showed strong reactivity to Toxoplasma antigens, especially to TgSAG1 (p30). No reactivity was observed to TgSAG1 in the six samples Tg-/Nc+. By TP-Nc, two highly immunodominant antigens (29 and 35 kDa proteins) were recognized by all 11 IFAT-Nc positive sera. Our results suggest that the infection by N, caninum can be concomitantly present in dogs from this area, although less common, and therefore should be considered in the differential clinical diagnosis with T. gondii in dogs presenting neuromuscular, respiratory and/or gastrointestinal disorders. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
Minidosimeters of L-alanine and 2-methylalanine (2MA) were prepared and tested as potential candidates for small radiation field dosimetry. To quantify the free radicals created by radiation a K-Band (24 GHz) EPR spectrometer was used. X-rays provided by a 6 MV clinical linear accelerator were used to irradiate the minidosimeters in the dose range of 0.5-30 Gy. The dose-response curves for both radiation sensitive materials displayed a good linear behavior in the dose range indicated with 2MA being more radiation sensitive than L-alanine. Moreover, 2MA showed a smaller LLD (lower limit detection) value. The proposed system minidosimeter/K-Band spectrometer was able to detect 10 Gy EPR spectra with good signal-to-noise ratio (S/N). The overall uncertainty indicates that this system shows a good performance for the detection of dose values of 20 Gy and above, which are dose values typically used in radiosurgery treatments. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Sporothrix schenckii is the etiologic agent of sporotrichosis, a mycosis of world-wide distribution more commonly occurring in tropical regions. The immunological mechanisms involved in the prevention and control of sporotrichosis are not fully understood but apparently include both the humoral and cellular responses. In the present investigation, cellular immunity was evaluated by in vivo and in vitro tests in mice infected with yeast-like forms of S. schenckii. The disease developed systemically and cellular immunity was evaluated for a period of 10 weeks. The soluble antigen utilized in the tests was prepared from yeast form of the fungus through the sonication (20 min: 10 sonications at 50 W at 2-min intervals). Delayed hypersensitivity and lymphocyte transformation tests showed that the cellular immune response was depressed between the 4th and 6th week of infection when the animals were challenged with the soluble fungal antigen. This depression frequently indicates worsening of the disease, with greater involvement of the host. This is a promising field of research for a better understanding of the pathogeny of this mycosis.
Resumo:
In view of the importance of venereal transmission of bovine leptospirosis, the objective of the present study was to apply the polymerase chain reaction (PCR) to 26 serovars of Leptospira interrogans, L. borgpetersenii, L. santarosai, L. noguchii and L. biflexa, to determine the detection threshold in semen samples and to evaluate the possibility of differentiation among serovars using 19 restriction endonucleases. The results showed that all serovars were amplified and the detection threshold in semen samples of a bull was 100 bacteria/ml. Using endonucleases we could classify the 26 serovars into eight groups. The present results show that PCR is a method of great potential for the detection of Leptospira spp, at bovine artificial insemination centers. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
The routine methods for detecting Listeria sp. in foods are time consuming and involve using selective enrichments and plating on agars. In this study, the presence of Listeria sp. in 120 meat and meat product samples was investigated by two rapid immunoassays (TECRA Listeria Visual Immunoassay [VIA] and BioControl Visual Immunoprecipitate Assay [VIP] for Listeria) and a cultural procedure. The cultural method of detecting Listeria sp. followed Canada's Health Protection Branch Method, and the rapid tests followed the manufacturers' instructions. The agreement between the cultural and the rapid tests was established at a confidence limit of 95%. Seventy-nine samples (65.8%) were Listeria sp. positive in at least one of the three tests. There was no statistically significant difference between the cultural procedure and any of the rapid immunoassays. The agreement rates between the VIA and the cultural method and between the VIP and the cultural method were 87 and 84%, respectively. Both tests - the VIA and VIP - proved to be rapid, efficient and easy to perform.
Resumo:
The design and characteristics of a novel electrochemical system, which uses a drop as a renewable electroanalytical sensor, are described. This article describes the performance of the electrochemical system, the coupling of the experimental arrangement with flow injection technique and a demonstration of its applicability for the measurement of sulfide. The method is based on renewable drops of ferricyanide ions, buffered by borate. The ferrocyanide ions, product of the reaction between ferricyanide and sulfide ions, are oxidized on a platinum microelectrode and the current measured is related to sulfide concentration. The measurements can be done in continuous or static flow mode. In continuous mode, the detection limit is 5.0 x 10(-5) mol L-1.
Resumo:
Several clean-up procedures which included the use of glass chromatography columns (silica gel, alumina, Florisil, silanized Celite-charcoal), Sep-Pak cartridges and standard solutions were compared for the determination of the following N-methylcarbamate (NMC) insecticides: aldicarb, carbaryl, carbofuran, methomyl and propoxur. According to recovery results of the compounds after elution in a glass column, the most efficient systems employed 4.6% deactivated alumina and a silanized Celite-charcoal (4:1) as adsorbents, using dichloromethane-methanol (99:1) and toluene-acetonitrile (75:25) mixtures, respectively, as binary eluents. The recoveries of the compounds studied varied from 84 to 120%. Comparable recoveries (75-100%) for Sep-Pak cartridges in normal phase (NH2, CN) and reversed phase (C-8) were observed. Different temperatures were tested during the concentration step in a rotary evaporator, and we verified a strong influence of this parameter on the stability of some compounds, such as carbofuran and carbaryl. Recovery studies employing the best clean up procedures were performed at the Brazilian agricultural level in potato and carrot samples; Validation methodology of the US Food and Drug Administration was adapted for the N-methylcarbamate analysis. Their recoveries ranged between 79 and 93% with coefficients of variation of 2.3-8%. (C) 1998 Elsevier B.V. B.V.
Resumo:
Sodium nitroprusside (NP), a commercial vasodilator, can be pre-concentrated on vitreous carbon electrode modified by films of 97.5%: 2.5% Poly-L-lysine (PLL): glutaraldehyde (GA). This coating gives acceptable anion exchange properties whilst giving the required improvement of adhesion to the glassy carbon electrode surface. Linear response range and detection limit on nitroprusside in B-R buffer pH 4.0, were 1 x 10(-6) to 2 x 10-(5) mol L-1 and 1 x 10(-7) mol L-1, respectively. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was measured as 4.1% for 10 experiments. The voltammetric sensor was directly applied to determination of nitroprusside in human plasma and urine samples and the average recovery for these samples was around 95-97% without any pre treatment.
Resumo:
A highly sensitive amperometric biosensor for determination of carbamate pesticides directly in water, fruit and vegetable samples has been evaluated, electrochemically characterized and optimized. The biosensor strip was fabricated in screen printed technique on a ceramic support using silver-based paste for reference electrode, and platinum-based paste for working and auxiliary electrodes. The working electrode was modified by a layer of carbon paste mixed with cobalt(II) phthalocyanine and acetylcellulose. Cholinesterase (ChE) enzymes with low enzymatic charge were immobilized on this layer. The operational simplicity of the biosensor consists in that a small drop (similar to 50 mu l) of substrate or sample is deposited on a horizontally positioned biosensor strip representing the microelectrochemical cell. The working potential of the biosensor was 370 mV versus Ag/AgI on a ship reference electrode preventing the interference of electroactive species which are oxidable at more positive potentials. The biosensor was applied to investigate the degradation of two reference ChE inhibitors in freeze dried water under different storage conditions and for direct determination of some N-methylcarbamates (NMCs) in fruit and vegetable samples at ppb concentration levels without any sample pretreatment. A comparison of the obtained results for the total carbamate concentration was done against those obtained using HPLC measurements. (C) 1999 Elsevier B.V. B.V. All rights reserved.