986 resultados para X-RAY-SCATTERING


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through the use of time-integrated space-resolved keV spectroscopy, we characterize line plasmas showing gain in Ne-like Zn with prepulsed irradiation to explain the enhanced performances of x-ray lasers using the prepulse technique. It is observed that the value of the electron temperature does not vary significantly with prepulse level, nor does its spatially resolved profile along the line. The lateral width and density of the Ne-like region in the plasma are seen to increase with the prepulse level. (C) 1995 Optical Society of America

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lasing properties of a collisional-excitation Ne-like Ge soft-x-ray laser have been studied with exploding-foil, single-slab, and double-slab targets under identical pumping conditions. Experimental results for the angular intensity distributions and the temporal variations of the lasing intensities are examined with a hydrodynamic code and ray-trace calculations. The observed angular distribution are well reproduced by these analyses, and it is found that the effective gain regions are located on the high-density side of the expected gain regions. It is shown that the observed lasing intensity of the J = 0 to J = 1 line is strongly correlated with the temporal change of the calculated electron temperature for both the slab and the exploding-foil targets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coupling of a soft X-ray laser beam with a relaying concave mirror in a sequentially pumped amplifier geometry using the Ne-like Ge system has been studied experimentally. Preliminary observations indicate an increase in the spatial coherence of the amplified relayed beam. In addition, near-field imaging of one of the amplifier plasmas shows a double-lobed intensity pattern of the emergent beam indicating refractive guiding of the amplified beam with components both normal and tangential to the target surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From measurements of spatial coherence and beam divergence of Ge soft x-ray laser at a far field, the x-ray laser beam has been characterized as a partially coherent Gaussian beam. Double-pass amplification will improve spatial and temporal coherence, spectral brightness and efficiency. Close to 100% geometrical coupling efficiency has been obtained in double pass amplification in Ge. Transient loss of feedback is attributed to mirror structure damage within the build-up time of the x-ray laser. Prospect for generation of coherent x-ray laser beam is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent developments and progress on collision pumped soft X-ray lasers using the VULCAN glass laser at Rutherford-Appleton Laboratory are presented. This includes saturated output operation of a double target germanium system within a low Fresnel number half-cavity, measurement of the spatial coherence of the output beam in the above and other geometries, use of the beam to demonstrate almost-equal-to 0.15 mum spatial resolution in a full-field microscope and initial studies of other Ne-like and Ni-like systems. Future directions, in the light of new developments of VULCAN facilities, are outlined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The photo-pump strengths of both the ((3 (d) over bar(4))(0)(3d(6))(0))(0)-(((3 (d) over bar(3))(3/2)(3d(6))(0))(3/2)(5 (f) over bar)(5/2))(1) and the ((3 (d) over bar(4))(0)(3d(6))0)0-(((3 (d) over bar(4))(0)(3d(5))(5/2))(5/2)(5f)(7/2))(1) transitions in Ni-like Sm34+ have been measured to be 2.0 x 10(-4) and 2.4 x 10(-4) photons/mode respectively. The implications of the measurement are briefly discussed in a comparison of the merits of automatically line matched photo-pump scheme to those of the collisional excitation Ni-like Sm+34 scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An imaging microscope, comprising a Schwarzchild condenser and zone plate optical arrangement, has been established on the Vulcan Nd-glass laser system at the Rutherford Appleton Laboratory (RAL). Images of simple test structures have been taken in X-ray transmission using doublet X-ray laser radiation at 23.2 nm and 23.6 nm from collisionally pumped Ne-like germanium. Image resolution of about 0.15 mum has been measured.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the properties of the exploding foil neon-like germanium soft X-ray lasers having wavelengths of 19-28 nm and gain length product of more than 10. The measured X-ray intensity of lasing lines from an exploding foil target has been explained with the results of the plasma hydrodynamic code from the viewpoint of suitable condition of electron density and temperature for creating population inversion.