942 resultados para Water quality indicator parameters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report summarizes the results of groundwater monitoring that took place from October 2014 - April 2015. Raw, untreated groundwater was sampled from forty-five municipal wells generall characterized as vulnerable to contamination from surface activities. Samples were analyzed for basic water quality parameters, nutrients, atrazine and two of its breakdown products, chloroacetanilide herbicides and their ethanesulfonic and oxanalic acid degradates, and a suite of sixteen pharmaceutical compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report summarizes the results of groundwater quality monitoring conducted at 68 public water supply wells in Iowa between October 2015 and March 2016. Raw groundwater samples were analyzed for basic water quality parameters, nutrients, atrazine and its degradates, and chloroacetanilide herbicides and their ethanesulfonic and oxanilic acid degradates. In addition, a subset of samples were analyzed for radionuclides including gross alpha and gross beta radioactivity, radium-226, and radium-228.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper a water quality index is developed to subsidize management actions in the Atibaia River for upon protection of aquatic organisms. This index is composed of two measurable environmental parameters normaly, ammonia and dissolved oxygen, the latter representing the contribution of organic matter. Concentrations of these two variables were normalized on a scale from 0 to 100 and translated into statements of quality (excellent, good, regular, bad and very bad). The index was applied to three monitoring points in the Atibaia River and compared to other indices used by the State of São Paulo Environmental Agency (CETESB). The results showed that the degradation in this watershed follows the urban population density. The developed index is more restricted than the other ones routinely used to infer water quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aeromonas genus is considered an emerging pathogen and its presence in drinking water supplies is a reason to public health concern. This study investigated the occurrence of Aeromonas in samples from collective reservoirs and wells used as drinking water sources in a peri-urban area. A total of 35 water samples were collected from collective reservoirs and 32 from wells bimonthly, from September 2007 to September 2008. Aeromonas spp determination was carried out using a Multiple-Tube Technique. Samples were inoculated into alkaline peptone water and the superficial film formed was transferred to blood agar plates amended with ampicillin. Typical Aeromonas colonies were submitted to a biochemical screening and then to biochemical tests for species differentiation. Aeromonas was detected in 13 (19%) of the 69 samples examined (6 from collective reservoirs and 7 from wells). Concentrations of Aeromonas in collective reservoirs ranged from <0.3 to 1.2 x10²MPN/100mL and, in wells, from <0.3 to 2.4 x10²MPN/100mL. The most frequent specie in the collective reservoir samples was Aeromonas spp (68%), followed by A. encheleia (14%) and A. allosaccharophila (8%) and A. hydrophila (8%). Aeromonas spp (87%) was the most frequent specie isolated from well samples, followed by A. allosacchariphila (8%), A. encheleia (2%) and A. jandaei (5%). These data show the presence and diversity of Aeromonas genus in the samples analyzed and highlight that its presence in drinking water poses a significant public health concern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effluents from pulp mill are usually toxic and mutagenic. This characteristic is mainly a consequence of xenobiotic compounds that are formed during the process. Global parameters such as chemical oxidation demand, total organic carbon and others, do not permit identify whether the toxic potential was remedied by the treatments or not. The objective of this research was to evaluate the performance of an horizontal-flow anaerobic immobilized biomass reactor (HAIB) treating the bleaching effluent from a Kraft pulp mill using toxicological (Daphnia similis - Ceriodaphnia sdvestrii) mutagenicity and citotoxicological assays (Allium cepa L). The results showed high sensibility of the test-organisms and capability of the anaerobic reactor to remove compounds that are exerting toxic and mutagenic effects. The bioassays represented an attractive alternative to water quality analyzes and the performance evaluation of treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As many countries are moving toward water sector reforms, practical issues of how water management institutions can better effect allocation, regulation, and enforcement of water rights have emerged. The problem of nonavailability of water to tailenders on an irrigation system in developing countries, due to unlicensed upstream diversions is well documented. The reliability of access or equivalently the uncertainty associated with water availability at their diversion point becomes a parameter that is likely to influence the application by users for water licenses, as well as their willingness to pay for licensed use. The ability of a water agency to reduce this uncertainty through effective water rights enforcement is related to the fiscal ability of the agency to monitor and enforce licensed use. In this paper, this interplay across the users and the agency is explored, considering the hydraulic structure or sequence of water use and parameters that define the users and the agency`s economics. The potential for free rider behavior by the users, as well as their proposals for licensed use are derived conditional on this setting. The analyses presented are developed in the framework of the theory of ""Law and Economics,`` with user interactions modeled as a game theoretic enterprise. The state of Ceara, Brazil, is used loosely as an example setting, with parameter values for the experiments indexed to be approximately those relevant for current decisions. The potential for using the ideas in participatory decision making is discussed. This paper is an initial attempt to develop a conceptual framework for analyzing such situations but with a focus on the reservoir-canal system water rights enforcement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inorganic elements analyses of Carapicuiba lake reveal that As, Cr, Pb and Mn are above the recommended drinking water standards. The mean total concentrations of toxic elements in surface water decrease in the order Mn > Cr > Pb > As. At elevated concentrations, toxic elements like Cr can accumulate in soils and enter the food chain, leading to serious health hazards and threatening the long-term sustainability of the local ecosystem. Absorbing materials has often been used to improve water quality. In this investigation three types of material were studied: the natural zeolite (mordenite); synthetic goethite and the powdered block carbon modified. The adsorption of Pb(2+) and Mn(2+) onto natural zeolite as a function of their concentrations was studied at 24 degrees C by varying the metal concentration from 100 to 400 mg L(-1) while keeping all other parameters constant. The low-cost zeolites removed Pb from water without any pretreatment at pH values <6. The maximum adsorption attained was as follows: Pb(2+) 78.7% and Mn(2+) 19.6%. The modified powdered block carbon effectively removed As(V) and Cr(VI) while goethite removed more chromate than arsenate in the pH range 5-6. Results of this study will be used to evaluate the application these materials for the treatment of the Carapicuiba lake`s water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The removal of chemicals in solution by overland how from agricultural land has the potential to be a significant source of chemical loss where chemicals are applied to the soil surface, as in zero tillage and surface-mulched farming systems. Currently, we lack detailed understanding of the transfer mechanism between the soil solution and overland flow, particularly under field conditions. A model of solute transfer from soil solution to overland flow was developed. The model is based on the hypothesis that a solute is initially distributed uniformly throughout the soil pore space in a thin layer at the soil surface. A fundamental assumption of the model is that at the time runoff commences, any solute at the soil surface that could be transported into the soil with the infiltrating water will already have been convected away from the area of potential exchange. Solute remaining at the soil surface is therefore not subject to further infiltration and may be approximated as a layer of tracer on a plane impermeable surface. The model fitted experimental data very well in all but one trial. The model in its present form focuses on the exchange of solute between the soil solution and surface water after the commencement of runoff. Future model development requires the relationship between the mass transfer parameters of the model and the time to runoff: to be defined. This would enable the model to be used for extrapolation beyond the specific experimental results of this study. The close agreement between experimental results and model simulations shows that the simple transfer equation proposed in this study has promise for estimating solute loss to surface runoff. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents major findings from a recent study aiming to systematically determine suitable river sections for local domestic water supply along the Yangtze River in Jiangsu Province, China. On the basis of analysis on the current riverbank utilization and bank stability, accessible and stable river sections in the region were selected. The water quality in these river sections was then studied using a two-dimensional unsteady flow and pollutant transport/transformation model, RBFVM-2D. The model was calibrated and verified against the hydrodynamic data, water quality data and remote sensing data collected from the river. The investigation on the pollution sources along the river identified 56 main pollution point sources. The pollution zones downstream of these point sources are the main threat for the water quality in the river. The model was used to compute the pollution zones. In particular, simulations were conducted to establish the relationship between the extent of the pollution zone and the wastewater discharge rate of the associated point source. These water quality simulation results were combined with the riverbank stability analysis to determine suitable river sections for local domestic water supply.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract: The Murray-Darling Basin comprises over 1 million km2; it lies within four states and one territory; and over 12, 800 GL of irrigation water is used to produce over 40% of the nation's gross value of agricultural production. This production is used by a diverse collection of some-times mutually exclusive commodities (e.g. pasture; stone fruit; grapes; cotton and field crops). The supply of water for irrigation is subject to climatic and policy uncertainty. Variable inflows mean that water property rights do not provide a guaranteed supply. With increasing public scrutiny and environmental issues facing irrigators, greater pressure is being placed on this finite resource. The uncertainty of the water supply, water quality (salinity), combined with where water is utilised, while attempting to maximising return for investment makes for an interesting research field. The utilisation and comparison of a GAMS and Excel based modelling approach has been used to ask: where should we allocate water?; amongst what commodities?; and how does this affect both the quantity of water and the quality of water along the Murray-Darling river system?

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effluent water from shrimp ponds typically contains elevated concentrations of dissolved nutrients and suspended particulates compared to influent water. Attempts to improve effluent water quality using filter feeding bivalves and macroalgae to reduce nutrients have previously been hampered by the high concentration of clay particles typically found in untreated pond effluent. These particles inhibit feeding in bivalves and reduce photosynthesis in macroalgae by increasing effluent turbidity. In a small-scale laboratory study, the effectiveness of a three-stage effluent treatment system was investigated. In the first stage, reduction in particle concentration occurred through natural sedimentation. In the second stage, filtration by the Sydney rock oyster, Saccostrea commercialis (Iredale and Roughley), further reduced the concentration of suspended particulates, including inorganic particles, phytoplankton, bacteria, and their associated nutrients. In the final stage, the macroalga, Gracilaria edulis (Gmelin) Silva, absorbed dissolved nutrients. Pond effluent was collected from a commercial shrimp farm, taken to an indoor culture facility and was left to settle for 24 h. Subsamples of water were then transferred into laboratory tanks stocked with oysters and maintained for 24 h, and then transferred to tanks containing macroalgae for another 24 h. Total suspended solid (TSS), chlorophyll a, total nitrogen (N), total phosphorus (P), NH4+, NO3-, and PO43-, and bacterial numbers were compared before and after each treatment at: 0 h (initial); 24 h (after sedimentation); 48 h (after oyster filtration); 72 h (after macroalgal absorption). The combined effect of the sequential treatments resulted in significant reductions in the concentrations of all parameters measured. High rates of nutrient regeneration were observed in the control tanks, which did not contain oysters or macroalgae. Conversely, significant reductions in nutrients and suspended particulates after sedimentation and biological treatment were observed. Overall, improvements in water quality (final percentage of the initial concentration) were as follows: TSS (12%); total N (28%); total P (14%); NH4+ (76%); NO3- (30%); PO43-(35%); bacteria (30%); and chlorophyll a (0.7%). Despite the probability of considerable differences in sedimentation, filtration and nutrient uptake rates when scaled to farm size, these results demonstrate that integrated treatment has the potential to significantly improve water quality of shrimp farm effluent. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new type of dual-channel PAM chlorophyll fluorometer has been developed, which is specialised in the detection of extremely small differences in photosynthetic activity in algae or thylakoids suspensions. In conjunction with standardised algae cultures or isolated thylakoids, the new device provides an ultrasensitive biotest system for detection of toxic substances in water samples. In this report, major features of the new device are outlined and examples of its performance are presented using suspensions of Phaeodactylum tricornutum (diatoms) and of freeze-dried thylakoids of Lactuca sativa (salad). Investigated and reference samples are exposed to the same actinic intensity of pulse-modulated measuring light. The quantum yields are assessed by the saturation pulse method. Clock-triggered repetitive measurements of quantum yield typically display a standard deviation of 0.1%, corresponding to the inhibition induced by 0.02 mug diuron l(-1). Hence, for diuron or compounds with similar toxicity, the detection limit is well below the 0.1 mug l(-1) defined as the limit for the presence of a single toxic substance in water by the European Commission drinking water regulation. The amounts of water and biotest material required for analysis are very small, as a single assay involves two 1 ml samples, each containing ca. 0.5 mug chlorophyll. Both with Phaeodactylum and thylakoids the relationship between inhibition and diuron concentration is strictly linear up to 10% inhibition, with very similar slopes. Apparent inhibition depends on the actinic effect of the measuring light, showing optima at 6 and 4 mumol quanta m(-2) s(-1) with Phaeodactylum and thylakoids, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gestão dos recursos hídricos necessita da integração entre os critérios físicos e químicos, e os aspectos bióticos, os quais possibilitam identificar os efeitos combinados de substâncias e avaliar suas influências. Os sistemas testes Allium cepa e Tradescantia pallida, são utilizados para o estudo da poluição aquática a partir de aspectos citogenéticos. Além destes biomarcadores, os teores de clorofila também são utilizados em estudos de estresse devido ao reflexo a múltiplos fatores. Assim, o objetivo deste trabalho foi avaliar a qualidade da água da lagoa Juara (Município de Serra/ES) pela análise integrada de aspectos físicos, químicos e ecotoxicológicos a partir de estudos citogenéticos em A. cepa e T. pallida, e fotossintéticos nesta última espécie. Foram definidas três estações amostrais ao longo da lagoa e a partir de amostras de água foram analisados parâmetros tais como condutividade, oxigênio dissolvido, concentração de nutrientes e metais. A determinação dos metais ocorreu por análises de espectrometria de massa. O teste do A. cepa foi realizado a partir sementes germinadas em amostras de água da lagoa. Com plantas de T. pallida, foi realizado o ensaio da mitose em ponta de raiz de T. pallida e dosado os teores de pigmentos cloroplastídicos em folhas totalmente expandidas. Para tanto, foi realizado ensaio utilizando-se a água da lagoa como solvente para solução de Hoagland onde estacas previamente enraizadas de T. pallida foram expostas durante 24 horas e 40 dias para as avaliações citogenéticas e fotossintéticas, respectivamente. Foi realizado novo teste do A. cepa nas águas da lagoa após os 40 dias de ensaio para aferir a manutenção das propriedades químicas das amostras. A avaliação citogenética nas duas espécies envolveu a análise dos índice mitótico (IM), índice de aberrações cromossômicas (AC) e frequência de micronúcleos (MN). Para a análise estatística foi utilizada a análise de variância seguida pelo teste de Tukey (p < 0.05) para a comparação dos tratamentos durante a mesma campanha, e teste de Bonferroni (p < 0,05) para a comparação entre as campanhas. Os resultados físicos e químicos mensurados demonstram que a lagoa Juara apresenta indícios de eutroficação artificial. Duas estações amostrais, em pelo menos uma campanha amostral, apresentaram potenciais citotóxico, genotóxico e mutagênico. Todavia, esses potenciais não demonstram relação com os teores de Fe e Mn quantificados, levando a crer que tais pontos apresentam outros potenciais poluentes. Os danos citogenéticos observados apresentaram efeitos maximizados durante a segunda campanha, demostrando o efeito do período de chuva na intensificação da poluição nesse ambiente. O estudo do metabolismo fotossintético em T. pallida, demonstrou os teores de pigmentos cloroplastídicos relacionados ao elevado aporte de nutrientes presentes nas estações J2 e J3. Sendo o excesso destes, o provável responsável pelo teor inferior de pigmentos em J3. Observa-se que os ensaios com A. cepa e T. pallida responderam de maneira fidedigna ao risco potencial do ambiente, complementando as análises físicas e químicas usualmente utilizadas na avaliação da qualidade da água de ambientes lacustres.