942 resultados para Wall Thickness
Resumo:
This work considers a problem of interest in several technological applications such as the thermal control of electronic equipment. It is also important to study the heat transfer performance of these components under off-normal conditions, such as during failure of cooling fans. The effect of natural convection on the flow and heat transfer in a cavity with two flush mounted heat sources on the left vertical wall, simulating electronic components, is studied numerically and experimentally. The influence of the power distribution, spacing between the heat sources and cavity aspect ratio have been investigated. An analysis of the average Nusselt number of the two heat sources was performed to investigate the behavior of the heat transfer coefficients. The results obtained numerically and experimentally, after an error analysis, showed a good agreement.
Resumo:
The plant cell wall is composed mainly of polysaccharides some constituted of repeating units of a single sugar, as cellulose or by two or more sugars grouped in repeating oligosaccharide blocks as the galactomannans and xyloglucans. Variations in composition and fine structure of these cell wall polysaccharides have been used as taxonomic markers and in the comprehension of the evolutive process, particularly in the Leguminosae. Partial hydrolysis of these compounds give rise to oligomers, some of which are capable of eliciting the synthesis of defensive substances in plants named phytoalexins. Species which differ in respect to phytoalexin liberation also differ in cell wall composition, particularly in the pectic fraction of the wall. Pectinases (mainly endopolygalacturonases) present in fungi, have been shown to hydrolyze plant cell walls yielding phytoalexin-eliciting oligosaccharides which differ in composition and in eliciting capacity in different species. These differences can be associated with the capacity of a given species to produce phytoalexins. On the other hand, the phytoalexin induction in plants is being used as a method of producing novel bioactive secondary metabolites.
Resumo:
Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.
Resumo:
The vascular segment of the caudal vena cava of the dog at the level of the caudate lobe was shown to be intimately related to hepatic tissue through the hepatic capsule and parenchyma. The tunica adventitia of the caudal vena cava was formed mainly by smooth muscle cells with collagen and elastic fibers arranged in bundles. The thin tunica media of the vein was also formed by smooth muscle cells, collagen and elastic fibers arranged in bundles. The tunica intima presented an elastic sub-endothelial network. The hepatic segment of the caudal vena cava showed a myoconnective architecture and propulsive characteristics in terms of its hemodynamic pattern.
Resumo:
Objective - To determine effects of reducing the diameter of the left ventricle of dogs by plication of the left ventricular free wall. Animals - 8 healthy adult mixed-breed dogs. Procedure - Left lateral thoracotomy and a T-shaped pericardiotomy were performed. The free wall of the left ventricle was imbricated with 3 interrupted transfixing sutures applied in a horizontal mattress pattern, using 3-0 polypropylene suture assembled on a straight cutting needle. Surgeons were careful to avoid the coronary vessels. Echocardiography was performed 24 hours before and 48 hours after surgery. Electrocardiography was performed before and 1, 2, 7, 15, 21, 30, and 60 days after surgery. Results - Echocardiographic measurements revealed that the diameter of the left ventricle was reduced by a mean of 23.5%. Electrocardiography revealed ventricular premature complexes 24 hours after surgery that regressed without treatment during the first week after surgery. Conclusions and Clinical Relevance - Plication of the left ventricular free wall of dogs can reduce end-diastolic and end-systolic dimensions of the left ventricle. The technique is simple and does not require cardiopulmonary bypass. According to Laplace's law, the reduction of cardiac diameter leads to reduction on free-wall tension and may improve left ventricular function in dilatated hearts. Thus, additional studies involving dogs with dilated cardiomyopathy should be conducted.
Resumo:
Objective - To evaluate plication of the free wall of the left ventricle, which reduces the left ventricular area and volume, as a method to improve the left ventricular systolic function without cardiopulmonary bypass. Animals - 8 mixed-breed adult dogs. Procedure - Dilated cardiomyopathy (DCM) was induced in each dog by administration of doxorubicin (30 mg/m2, IV, q 21 d for 168 days). Two dogs died during induction of cardiomyopathy. Plication surgery was performed in 4 dogs. Two dogs did not ondergo to surgery (control group). Values for cardiac output (CO), 2-dimensional and M-mode echocardiography, arterial blood pressure, electrocardiography, blood cell counts, and serum biochemical analyses were recorded after induction of DCM (baseline) and 1, 2, 7, 15, 21, 30, 60, 90, 120, 150, and 180 days after plication surgery. Ambulatory ECG (Holter) recordings were conducted for 24 hours on the day of surgery. Results - 1 dog died after plication surgery. The remaining dogs undergoing ventricular plication had a significant improvement in CO, ejection fraction, and fractional shortening and reductions of left ventricular area and volume after surgery. Electrocardiographic and Holter recordings revealed premature ventricular complexes, which resolved without treatment during the first week after surgery. Clinical condition of the control dogs declined, and these 2 dogs died approximately 40 days after induction of cardiomyopathy. Conclusions and Clinical Relevance - Plication of the free wall of the left ventricle improved left ventricular systolic function in dogs with doxorubicin-induced cardiomyopathy. Additional studies are needed to evaluate its application in dogs with naturally developing DCM.
Resumo:
Objective: The aim of this study is to analyze the effects of copper vapor laser radiation on the radicular wall of human teeth. Materials and Methods: Immediately after the crowns of 10 human uniradicular teeth were cut along the cement-enamel junction, a chemical-surgical preparation of the radicular canals was completed. Then the roots were longitudinally sectioned to allow for irradiation of the surfaces of the dentin walls of the root canals. The hemi-roots were separated into two groups: one (control) with five hemi-roots that were not irradiated, and another (experimental) with 15 hemi-roots divided into three subgroups that were submitted to the following exposure times: 0.02,0.05, and 0.1 s. A copper vapor laser (510.6 nm) with a total average power of 6.5 W in green emission, frequency of 16.000 Hz, and pulse duration of 30 ns was used. Results: The results obtained by scanning electron microscope analysis showed the appearance of a cavity in the region of laser beam impact, with melting, recrystallization, and cracking on the edges of the dentin of the cavity due to heat diffusion. Conclusions: We determined that the copper vapor laser produces significant morphologic changes in the radicular wall of human teeth when using the parameters in this study. However, further research should be done to establish parameters that are compatible with dental structure in order to eliminate thermal damages. © Mary Ann Liebert, Inc.
Resumo:
Eimeria rhynchoti is redescribed parasitizing partridge (Rhynchotus rufescens), reared in captivity, from Jaboticabal City, São Paulo State, Brazil. Sporulation takes place in 48 hours, the shape of oocysts found vary from spherical to elliptic with 23.01 micro +/- 1.57 of length by 21.0 micro +/- 1.78 of width. The microple, polar cap and residuum of the oocysts were absent. The oocyst wall, measures 2.2 micro +/- 0.31 of thickness, is composed by two smooth layers; the polar granule is present. The sporocysts length was 15.03 mm +/- 2.12 by 8.08 mm +/- 0.84 of width vary from elliptic to elongate. Sporocyst wall slender with is fine and Stieda body; the residue found in form of several smaller granules spherical compacts. The sporozoites are contrary extending along the sporocysts wall possessing refracts body of easy visualization.
Resumo:
Light microscopy analysis of the mural structure of the common carotid artery, internal carotid artery and external carotid artery in mongrel dog revealed variability in the middle values of vascular diameter and thickness of the intimal plus medial coats and adventitial coat. The vascular diameter did not differ between the internal carotid artery and external carotid artery, but was significantly increased in the common carotid artery from which the other two arteries had origin. The increased thickness of the intimal plus medial coats of the common carotid artery revealed the constant mechanical adjustment of the arterial wall and local shearing stress that occurred among the arterial coats. The adventitial coat of the internal carotid artery was significantly thicker than those of the common carotid and external carotid arteries, with no significant difference noted between the latter arteries. These histomorphometric results were related to the qualitative observations regarding the mural structure of the three arteries analyzed, especially regarding to the increased thickness and structural complexity of the adventitial coat of the internal carotid artery. Perhaps it acted as an external protective sheath of the vascular wall during its long course until the carotid channel. © 2006 Sociedad Chilena de Anatomía.
Resumo:
The genus Staurogyne Wall. comprises about 140 tropical species, and in the Neotropics 28 species are recognized, especially found in preserved forested areas. A recent revision of the genus for the Americas revealed four new species in Brazil, which are here described. The new taxa are known from Goiás, Minas Gerais, Espírito Santo, São Paulo, Rio de Janeiro, Paraná and Santa Catarina States, three of them occurring in the Atlantic Rain Forest, and one in the gallery forests of the cerrado domain.
Resumo:
This study aimed to evaluate the influence of cement thickness on the bond strength of a fiber-reinforced composite (FRC) post system to the root dentin. Eighteen single-rooted human teeth were decoronated (length: 16 mm), the canals were prepared, and the specimens were randomly allocated to 2 groups (n = 9): group 1 (low cement thickness), in which size 3 FRC posts were cemented using adhesive plus resin cement; and group 2 (high cement thickness), in which size 1 FRC posts were cemented as in group 1. Specimens were sectioned, producing 5 samples (thickness: 1.5 mm). For cement thickness evaluation, photographs of the samples were taken using an optical microscope, and the images were analyzed. Each sample was tested in push-out, and data were statistically analyzed. Bond strengths of groups 1 and 2 did not show significant differences (P = .558), but the cement thicknesses for these groups were significantly different (P < .0001). The increase in cement thickness did not significantly affect the bond strength (r2 = 0.1389, P = .936). Increased cement thickness surrounding the FRC post did not impair the bond strength.
Resumo:
Purpose: The aim of this study was to evaluate the fracture resistance of ceramic plates cemented to dentin as a function of the resin cement film thickness. Materials and Methods: Ceramic plates (1 and 2 mm thicknesses) were cemented to bovine dentin using resin composite cement. The film thicknesses used were approximately 100, 200, and 300 μm. Noncemented ceramic plates were used as control. Fracture loads (N) were obtained by compressing a steel indenter in the center of the ceramic plates. ANOVA and Tukey tests (α = 0.05) were used for each ceramic thickness to compare fracture loads among resin cement films used. Results: Mean fracture load (N) for 1-mm ceramic plates were: control - 26 (7); 100 μm - 743 (150); 200 μm - 865 (105); 300 μm - 982 (226). Test groups were significantly different from the control group; there was a statistical difference in fracture load between groups with 100 and 300 μm film thicknesses (p < 0.01). Mean fracture load for 2-mm ceramic plates were: control - 214 (111); 100 μm - 1096 (341); 200 μm - 1067 (226); 300 μm - 1351 (269). Tested groups were also significantly different from the control group (p < 0.01). No statistical difference was shown among different film thicknesses. Conclusions: Unluted specimens presented significantly lower fracture resistance than luted specimens. Higher cement film thickness resulted in increased fracture resistance for the 1-mm ceramic plates. Film thickness did not influence the fracture resistance of 2-mm porcelain plates. Copyright © 2007 by The American College of Prosthodontists.
Resumo:
In this work the color dependence of resin composites with the background color was evaluated. The objective was to measure since what thickness the color of the sample stops being influenced by the color of the background over which the resin is placed and the methodology used in experiment was based in analyzing the contrast of digital images of the sample over a black background. The results shown that since 0.8 mm the images contrast becomes almost constant; it prove that since this thickness the color of resin composite depends on the optical resin properties only. The experiment was repeated under three conditions of luminosity to evaluate the influence of it on the image contrast and the results obtained were identical.
Resumo:
Selection of the proper shade and color matching of restorations to natural dentition continues to be one of the most frustrating problems in dentistry and currently available shade guide presents a limited selection of colors compared to those found in natural dentition. This investigation evaluation if the composites resins shade B2 are equivalent to the Vita shade guide B2. Twelve composite resins (Renamel Microfill Super Brite- Cosmedent USA, Renamel Universal Brite- Cosmedent USA, Renamel Microfill Body- Cosmedent USA, Renamel Universal Body- Cosmedent USA, Opallis EB2-FGM, Opallis DB2-FGM, Filtek Supreme XT-3M/ESPE, Filtek Z250-3M/ESPE, Filtek Z350-3M/ESPE, Z100-3M/ESPE, 4 Seasons Dentin - Ivoclar/Vivadent, Tetric Ceram - Ivoclar/Vivadent) shade B2 were used. From each composite, two specimens were made in a steel matrix with 8.0 mm diameter and 10.0 mm different predetermined thickness (0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0 mm). The specimens were 40 seconds light polymerized by LED Ultrablue (DMC). The specimens were measured 10 times each to determine the shade using a reflectance spectrophotometer (Pocket Spec). According to results was verified that not any of composites resins shade B2 evaluated in this study presented values of color difference (ΔE) equivalent to the Vita shade guide B2 and the 2 mm thickness showed the closer match to the Vita shade guide B2.
Resumo:
Purpose: This study evaluated the influence of polymerization cycle and thickness of maxillary complete denture bases on the porosity of acrylic resin. Materials and Methods: Two heat-activated denture base resins - one conventional (Clássico) and one designed for microwave polymerization (Onda-Cryl) - were used. Four groups were established, according to polymerization cycles: A (Onda-Cryl, short microwave cycle), B (Onda-Cryl, long microwave cycle), C (Onda-Cryl, manufacturing microwave cycle), and T (Clássico, water bath). Porosity was evaluated for different thicknesses (2.0, 3.5, and 5.0 mm; thicknesses I, II, and III, respectively) by measurement of the specimen volume before and after its immersion in water. The percent porosity data were submitted to Kruskal-Wallis for comparison among the groups. Results: The Kruskal-Wallis test detected that the combinations of the different cycles and thicknesses showed significant differences, and the mean ranks of percent porosity showed differences only in the thinnest (2.0 mm) microwave-polymerized specimens (A = 53.55, B = 40.80, and C = 90.70). Thickness did not affect the results for cycle T (I = 96.15, II = 70.20, and III = 82.70), because porosity values were similar in the three thicknesses. Conclusions: Microwave polymerization cycles and the specimen thickness of acrylic resin influenced porosity. Porosity differences were not observed in the polymerized resin bases in the water bath cycle for any thickness. © 2007 by The American College of Prosthodontists.