969 resultados para Validation Measures
Resumo:
The updated Vienna Prediction Model for estimating recurrence risk after an unprovoked venous thromboembolism (VTE) has been developed to identify individuals at low risk for VTE recurrence in whom anticoagulation (AC) therapy may be stopped after 3 months. We externally validated the accuracy of the model to predict recurrent VTE in a prospective multicenter cohort of 156 patients aged ≥65 years with acute symptomatic unprovoked VTE who had received 3 to 12 months of AC. Patients with a predicted 12-month risk within the lowest quartile based on the updated Vienna Prediction Model were classified as low risk. The risk of recurrent VTE did not differ between low- vs higher-risk patients at 12 months (13% vs 10%; P = .77) and 24 months (15% vs 17%; P = 1.0). The area under the receiver operating characteristic curve for predicting VTE recurrence was 0.39 (95% confidence interval [CI], 0.25-0.52) at 12 months and 0.43 (95% CI, 0.31-0.54) at 24 months. In conclusion, in elderly patients with unprovoked VTE who have stopped AC, the updated Vienna Prediction Model does not discriminate between patients who develop recurrent VTE and those who do not. This study was registered at www.clinicaltrials.gov as #NCT00973596.
Resumo:
BACKGROUND AND PURPOSE: The Prestroke Independence, Sex, Age, National Institutes of Health Stroke Scale (ISAN) score was developed recently for predicting stroke-associated pneumonia (SAP), one of the most common complications after stroke. The aim of the present study was to externally validate the ISAN score. METHODS: Data included in the Athens Stroke Registry between June 1992 and December 2011 were used for this analysis. Inclusion criteria were the availability of all ISAN score variables (prestroke independence, sex, age, National Institutes of Health Stroke Scale score). Receiver operating characteristic curves and linear regression analyses were used to determine the discriminatory power of the score and to assess the correlation between actual and predicted pneumonia in the study population. Separate analyses were performed for patients with acute ischemic stroke (AIS) and intracerebral hemorrhage (ICH). RESULTS: The analysis included 3204 patients (AIS: 2732, ICH: 472). The ISAN score demonstrated excellent discrimination in patients with AIS (area under the curve [AUC]: .83 [95% confidence interval {CI}: .81-.85]). In the ICH group, the score was less effective (AUC: .69 [95% CI: .63-.74]). Higher-risk groups of ISAN score were associated with an increased relative risk of SAP; risk increase was more prominent in the AIS population. Predicted pneumonia correlated very well with actual pneumonia (AIS group: R(2) = .885; β-coefficient = .941, P < .001; ICH group: R(2) = .880, β-coefficient = .938, P < .001). CONCLUSIONS: In our external validation in the Athens Stroke Registry cohort, the ISAN score predicted SAP very accurately in AIS patients and demonstrated good discriminatory power in the ICH group. Further validation and assessment of clinical usefulness would strengthen the score's utility further.
Resumo:
Following their detection and seizure by police and border guard authorities, false identity and travel documents are usually scanned, producing digital images. This research investigates the potential of these images to classify false identity documents, highlight links between documents produced by a same modus operandi or same source, and thus support forensic intelligence efforts. Inspired by previous research work about digital images of Ecstasy tablets, a systematic and complete method has been developed to acquire, collect, process and compare images of false identity documents. This first part of the article highlights the critical steps of the method and the development of a prototype that processes regions of interest extracted from images. Acquisition conditions have been fine-tuned in order to optimise reproducibility and comparability of images. Different filters and comparison metrics have been evaluated and the performance of the method has been assessed using two calibration and validation sets of documents, made up of 101 Italian driving licenses and 96 Portuguese passports seized in Switzerland, among which some were known to come from common sources. Results indicate that the use of Hue and Edge filters or their combination to extract profiles from images, and then the comparison of profiles with a Canberra distance-based metric provides the most accurate classification of documents. The method appears also to be quick, efficient and inexpensive. It can be easily operated from remote locations and shared amongst different organisations, which makes it very convenient for future operational applications. The method could serve as a first fast triage method that may help target more resource-intensive profiling methods (based on a visual, physical or chemical examination of documents for instance). Its contribution to forensic intelligence and its application to several sets of false identity documents seized by police and border guards will be developed in a forthcoming article (part II).
Resumo:
OBJECTIVE: Since 2011, the new national final examination in human medicine has been implemented in Switzerland, with a structured clinical-practical part in the OSCE format. From the perspective of the national Working Group, the current article describes the essential steps in the development, implementation and evaluation of the Federal Licensing Examination Clinical Skills (FLE CS) as well as the applied quality assurance measures. Finally, central insights gained from the last years are presented. METHODS: Based on the principles of action research, the FLE CS is in a constant state of further development. On the foundation of systematically documented experiences from previous years, in the Working Group, unresolved questions are discussed and resulting solution approaches are substantiated (planning), implemented in the examination (implementation) and subsequently evaluated (reflection). The presented results are the product of this iterative procedure. RESULTS: The FLE CS is created by experts from all faculties and subject areas in a multistage process. The examination is administered in German and French on a decentralised basis and consists of twelve interdisciplinary stations per candidate. As important quality assurance measures, the national Review Board (content validation) and the meetings of the standardised patient trainers (standardisation) have proven worthwhile. The statistical analyses show good measurement reliability and support the construct validity of the examination. Among the central insights of the past years, it has been established that the consistent implementation of the principles of action research contributes to the successful further development of the examination. CONCLUSION: The centrally coordinated, collaborative-iterative process, incorporating experts from all faculties, makes a fundamental contribution to the quality of the FLE CS. The processes and insights presented here can be useful for others planning a similar undertaking.
Resumo:
AIM: To develop and test the Parental PELICAN Questionnaire, an instrument to retrospectively assess parental experiences and needs during their child's end-of-life care. BACKGROUND: To offer appropriate care for dying children, healthcare professionals need to understand the illness experience from the family perspective. A questionnaire specific to the end-of-life experiences and needs of parents losing a child is needed to evaluate the perceived quality of paediatric end-of-life care. DESIGN: This is an instrument development study applying mixed methods based on recommendations for questionnaire design and validation. METHOD: The Parental PELICAN Questionnaire was developed in four phases between August 2012-March 2014: phase 1: item generation; phase 2: validity testing; phase 3: translation; phase 4: pilot testing. Psychometric properties were assessed after applying the Parental PELICAN Questionnaire in a sample of 224 bereaved parents in April 2014. Validity testing covered the evidence based on tests of content, internal structure and relations to other variables. RESULTS: The Parental PELICAN Questionnaire consists of approximately 90 items in four slightly different versions accounting for particularities of the four diagnostic groups. The questionnaire's items were structured according to six quality domains described in the literature. Evidence of initial validity and reliability could be demonstrated with the involvement of healthcare professionals and bereaved parents. CONCLUSION: The Parental PELICAN Questionnaire holds promise as a measure to assess parental experiences and needs and is applicable to a broad range of paediatric specialties and settings. Future validation is needed to evaluate its suitability in different cultures.
Resumo:
The aim of this study was the validation of a brief form of the Perceived Neighborhood Social Cohesion questionnaire using data from 5065 men from the "Cohort Study on Substance-Use Risk Factors." A 9-item scale covering three factors was proposed. Excellent indices of internal consistency were measured (α = .93). The confirmatory factor analyses resulted in acceptable fit indices supporting measurement invariance across French and German forms. Significant correlations were found between the brief form of the Perceived Neighborhood Social Cohesion questionnaire, and satisfaction and self-reported health, providing evidence of the concurrent validity of the scale. Perceived neighborhood social cohesion, and depression and suicide attempts were negatively associated, sustaining the protective effect of perceived social cohesion.
Resumo:
Objectives: The present study evaluates the reliability of the Radio Memory® software (Radio Memory; Belo Horizonte,Brasil.) on classifying lower third molars, analyzing intra- and interexaminer agreement of the results. Study Design: An observational, descriptive study of 280 lower third molars was made. The corresponding orthopantomographs were analyzed by two examiners using the Radio Memory® software. The exam was repeated 30 days after the first observation by each examiner. Both intra- and interexaminer agreement were determined using the SPSS v 12.0 software package for Windows (SPSS; Chicago, USA). Results: Intra- and interexaminer agreement was shown for both the Pell & Gregory and the Winter classifications, p<0.01, with 99% significant correlation between variables in all the cases. Conclusions: The use of Radio Memory® software for the classification of lower third molars is shown to be a valid alternative to the conventional method (direct evaluation on the orthopantomograph), for both clinical and investigational applications.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.
Resumo:
The purpose of this study is the adaptation and validation of the"Survey Work-Home Interaction NijmeGen" (SWING) developed by Geurts and colleagues to Spanish speaking countries (SWING-SSC). In order to analyze the questionnaire"s psychometric properties, confirmatory factor analysis (CFA) was carried out with a sample of 203 employees from various Spanish-speaking countries. Criterion related validity was tested by examining correlations between the SWING-SSC, and the theoretically relevant variables: health, role conflict, role clarity and supervisor support. Finally, reliability was tested analyzing the internal consistency of the scales. The analyses carried out indicate that SWING-SSC has good psychometric properties. In addition, the present results support the relation of the construct with health, role conflict, role clarity, and supervisor support. This study offers evidence for a sound work-life balance measure that contributes to the encouragement adequate conditions in the workplace, to reduce the conflict between the two spheres of professional and personal life, and to enhance positive relationships.
Resumo:
We have designed and validated a novel generic platform for production of tetravalent IgG1-like chimeric bispecific Abs. The VH-CH1-hinge domains of mAb2 are fused through a peptidic linker to the N terminus of mAb1 H chain, and paired mutations at the CH1-CL interface mAb1 are introduced that force the correct pairing of the two different free L chains. Two different sets of these CH1-CL interface mutations, called CR3 and MUT4, were designed and tested, and prototypic bispecific Abs directed against CD5 and HLA-DR were produced (CD5xDR). Two different hinge sequences between mAb1 and mAb2 were also tested in the CD5xDR-CR3 or -MUT4 background, leading to bispecific Ab (BsAbs) with a more rigid or flexible structure. All four Abs produced bound with good specificity and affinity to CD5 and HLA-DR present either on the same target or on different cells. Indeed, the BsAbs were able to efficiently redirect killing of HLA-DR(+) leukemic cells by human CD5(+) cytokine-induced killer T cells. Finally, all BsAbs had a functional Fc, as shown by their capacity to activate human complement and NK cells and to mediate phagocytosis. CD5xDR-CR3 was chosen as the best format because it had overall the highest functional activity and was very stable in vitro in both neutral buffer and in serum. In vivo, CD5xDR-CR3 was shown to have significant therapeutic activity in a xenograft model of human leukemia.
Resumo:
OBJECTIVE: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. METHODS: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. RESULTS: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). CONCLUSION: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. ADVANCES IN KNOWLEDGE: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.
Resumo:
Fibrose pulmonaire idiopathique La fibrose pulmonaire idiopathique (FPI, Idiopathic Pulmonary Fibrosis) est une maladie diffuse du parenchyme pulmonaire de cause inconnue caractérisée par une aggravation de la dyspnée, une réduction du volume pulmonaire et une altération des échanges gazeux. Elle est la plus fréquente de pneumopathies interstitielles idiopathiques (IIPs, Idiopathic Interstitial Pneumonias), avec une incidence annuelle estimée entre 4,6 et 16,3 pour 100'000 personnes et une prévalence de 13 à 20 cas pour 100 000 personnes. Son évolution est progressive, irréversible et de mauvais pronostic avec une survie médiane de 2 à 3.5 ans et une survie à 5 ans de moins de 20%.