940 resultados para Ultrasonic atomization
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Com o objetivo de avaliar a superfície dentinária apical, após a remoção de diferentes pastas de hidróxido de cálcio (Ca(OH)2), foram selecionados 68 dentes unirradiculares, preparados por um único operador, valendo-se da técnica regressiva. Os canais foram irrigados com 5ml de hipoclorito de sódio (NaOCl) a 1%, seguido de irrigação final com 10 ml de ácido etilenodiaminotetracético associado ao tergentol (EDTA-T) a 17%. As amostras foram divididas, aleatoriamente, em 4 grupos (n=15), de acordo com o tipo de associação de Ca(OH)2: associado à solução de clorexidina 0.2% (Grupo 1); ao propilenoglicol (Grupo 2); à ciprofloxacina, metronidazol e água destilada (Grupo 3); à ciprofloxacina, metronidazol e propilenoglicol (Grupo 4). Os dentes controle negativos (n=4) não foram preenchidos com Ca(OH)2, e nos controle positivo, (n=4) não foi feita a remoção do Ca(OH)2. As amostras foram armazenadas à 37ºC, em 100% de umidade relativa, por 21 dias. A remoção da medicação foi realizada com: irrigação com 5ml de NaOCl 1%; limagem circunferencial com instrumento memória; 5ml de NaOCl 1%; patência com lima K #10; ultra-som com lima K #15; e 10ml de EDTA-T a 17%. Os espécimes foram analisados em microscópio eletrônico de varredura e, após a aplicação do teste de Kruskal-Wallis (α = 5%), observou-se que não houve diferença entre os grupos em relação à remoção do Ca(OH)2 (p = 0.0951). O teste Qui-quadrado (α = 5%) indicou a predominância de Ca(OH)2 obstruindo os túbulos dentinários, independente do veículo utilizado. Após análise química pontual (espectrometria por dispersão de raios-x EDS) e, aplicação do teste de análise das variâncias e Tukey (α = 5%), pôde-se observar que houve diferença na quantidade de íons cálcio (Ca) remanescente entre os grupos 1 e 4 (p<0.01). Com base na metodologia empregada, concluiu-se que, independente do tipo de veículo utilizado, a superfície dentinária apical permaneceu igualmente coberta por Ca (OH)2.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Selenium is both essential and toxic to man and animals, depending on the concentration and the ingested form. Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source. Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C). This simple sample treatment avoided contamination and decreased the analysis time. The standard additions method was adopted for quantification. The action of the autosampler was improved by the presence of the amines mixture in the suspension. A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk. Background correction was performed by means of the Zeeman effect. Pyrolytically coated graphite tubes were employed. Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200oC, respectively. For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 mg L-1 and in coconut milk from 24.2 to 25.1 mg L-1. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3% range. The main advantage of the proposed method is that it can be directly applied without sample decomposition.
Resumo:
Calcium aluminate cements (CAC) were prepared using the sonochemical process, followed by heat treatment. A study was made of the action of ultrasonic waves and the influence of thermal treatment conditions on two initial molar compositions of 1:1 and 1:2 of calcia:alumina. The aqueous suspension containing the raw materials (A-50 alumina and CaO) was subjected to an ultrasonic bath, followed by drying and burning at 1000, 1200 and 1300 ºC. These cements were characterized by SEM, XRD and the mechanical strength was evaluated by splitting tensile tests, using commercial cement as a reference. Furthermore, the phases were semi-quantified using the Rietveld method. The results show that hydration and sonochemical action increased the reactivity of the raw materials during firing and that phase formation is dependent on the thermal treatment conditions. The CAC cements were obtained at temperatures at least 200 ºC lower than those used in conventional methods, indicating the potential of this route of synthesis.
Resumo:
As imagens da parede do poço obtidas através da ferramenta UBI (Ultrasonic Borehole Imager) são amplamente utilizadas por geólogos e engenheiros de petróleo para identificar eventos geológicos nas paredes de poços abertos e na inspeção dos tubos de revestimento, uma vez que este perfil praticamente fornece uma fotografia da parede do poço. As ferramentas de imageamento acústico produzem imagens do tempo de trânsito e da amplitude do pulso acústico gerado pela ferramenta e refletido na parede do poço. Entretanto, estas imagens podem ter uma interpretação não realista, uma vez que elas podem ter seu aspecto alterado em razão do movimento da ferramenta no interior do poço. Este trabalho apresenta o modelamento das imagens de tempo de trânsito a partir da aplicação do critério de Coulomb para a ruptura da parede do poço submetida a um estado plano de tensões, a qual fornecerá a seção do poço, que é a forma geométrica que será traçada pela ferramenta de imageamento acústico do poço. O deslocamento ascensional da ferramenta e as imperfeições da parede do poço, normalmente, são os responsáveis pelo deslocamento da posição do transdutor em relação ao eixo do poço. Este efeito pode ter grande responsabilidade nas imperfeições das imagens de tempo de trânsito. Assim, a correção dessas imagens, chamada de correção da descentralização, busca o reposicionamento do transdutor para a posição do eixo do poço. Apresenta-se, também, um método de correção do efeito da descentralização da ferramenta baseado neste modelamento. O método é proposto com base na geometria analítica plana e no método do raio para a definição do tempo de trânsito do pulso acústico, com o objetivo de reconstruir as imagens de tempo de trânsito obtidas com a ferramenta descentralizada, ou seja, corrigir estas imagens tornando-as como se fossem obtidas com a ferramenta centralizada em relação ao eixo do poço.