999 resultados para Ultra cold quantum gases


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the effects of the world's most challenging mountain ultra-marathon (Tor des Géants(®) 2012) on the energy cost of three types of locomotion (cycling, level and uphill running) and running kinematics. METHODS: Before (pre-) and immediately after (post-) the competition, a group of ten male experienced ultra-marathon runners performed in random order three submaximal 4-min exercise trials: cycling at a power of 1.5 W kg(-1) body mass; level running at 9 km h(-1) and uphill running at 6 km h(-1) at an inclination of +15 % on a motorized treadmill. Two video cameras recorded running mechanics at different sampling rates. RESULTS: Between pre- and post-, the uphill-running energy cost decreased by 13.8 % (P = 0.004); no change was noted in the energy cost of level running or cycling (NS). There was an increase in contact time (+10.3 %, P = 0.019) and duty factor (+8.1 %, P = 0.001) and a decrease in swing time (-6.4 %, P = 0.008) in the uphill-running condition. CONCLUSION: After this extreme mountain ultra-marathon, the subjects modified only their uphill-running patterns for a more economical step mechanics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: New methods of ultra-rapid opiate detoxification (URD) under intravenous sedation have been criticized because of limited data on safety and long-term follow-up. Premedication with buprenorphine has been advocated to improve safety by decreasing vomiting. Prior research has not explored URD in socially impaired patients. METHOD: Sixteen patients were detoxified with URD and prospectively evaluated over at least 30 months. Data of this procedure were compared with those of our previous study without buprenorphine preparation (Drug Alcohol Depend. 52(3) (1998) 243). The 16 patients were followed up by a general practitioner (GP) before and after URD. The GPs also supervised the 7-day course of buprenorphine treatment prescribed for the 16 patients prior to URD. RESULTS: During the procedure, only one episode of vomiting occurred instead of 13 out of 20 in our previous study. Post-procedure, only two patients experienced moderate withdrawal symptoms, such as persistent nausea, abdominal cramps and vomiting lasting from 24 to 48 h, in comparison with most patients in the previous study without buprenorphine. After a period of at least 30 months (36.0+/-6.38), the 16 patients were still alive and were regularly monitored by their GP. Only two of the 16 never relapsed after URD and reported total opiate abstinence. Fourteen patients relapsed; 12 of these were prescribed a licensed methadone substitution program and two were still using heroin. CONCLUSION: In this small sample, the data indicated that URD with buprenorphine preparation was safe and that it markedly decreased post-procedure morbidity. No patient died over a minimum 30-month follow-up period. Furthermore, the procedure was employed with socially impaired patients. In the long term, a few patients were still free of opiates, while the majority opted for a methadone maintenance program, showing that URD can serve as one possible step in a long-term treatment program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conditions for the analysis of selected doping substances by UHPSFC-MS/MS were optimized to ensure suitable peak shapes and maximized MS responses. A representative mixture of 31 acidic and basic doping agents was analyzed, in both ESI+ and ESI- modes. The best compromise for all compounds in terms of MS sensitivity and chromatographic performance was obtained when adding 2% water and 10mM ammonium formate in the CO2/MeOH mobile phase. Beside mobile phase, the nature of the make-up solvent added for interfacing UHPSFC with MS was also evaluated. Ethanol was found to be the best candidate as it was able to compensate for the negative effect of 2% water addition in ESI- mode and provided a suitable MS response for all doping agents. Sensitivity of the optimized UHPSFC-MS/MS method was finally assessed and compared to the results obtained in conventional UHPLC-MS/MS. Sensitivity was improved by 5-100-fold in UHPSFC-MS/MS vs. UHPLC-MS/MS for 56% of compounds, while only one compound (bumetanide) offered a significantly higher MS response (4-fold) under UHPLC-MS/MS conditions. In the second paper of this series, the optimal conditions for UHPSFC-MS/MS analysis will be employed to screen >100 doping agents in urine matrix and results will be compared to those obtained by conventional UHPLC-MS/MS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review covers some of the contributions to date from cerebellar imaging studies performed at ultra-high magnetic fields. A short overview of the general advantages and drawbacks of the use of such high field systems for imaging is given. One of the biggest advantages of imaging at high magnetic fields is the improved spatial resolution, achievable thanks to the increased available signal-to-noise ratio. This high spatial resolution better matches the dimensions of the cerebellar substructures, allowing a better definition of such structures in the images. The implications of the use of high field systems is discussed for several imaging sequences and image contrast mechanisms. This review covers studies which were performed in vivo in both rodents and humans, with a special focus on studies that were directed towards the observation of the different cerebellar layers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is dedicated to investigation of the energy spectrum of one of the most anisotropic narrow-gap semiconductors, CdSb. At the beginning of the present studies even the model of its energy band structure was not clear. Measurements of galvanomagnetic effects in wide temperature range (1.6 - 300 K) and in magnetic fields up to 30 T were chosen for clarifying of the energy spectrum in the intentionally undoped CdSb single crystals and doped with shallow impurities (In, Ag). Detection of the Shubnikov - de Haas oscillations allowed estimating the fundamental energy spectrum parameters. The shapes of the Fermi surfaces of electrons (sphere) and holes (ellipsoid), the number of the equivalent extremums for valence band (2) and their positions in the Brillouin zone were determined for the first time in this work. Also anisotropy coefficients, components of the tensor of effective masses of carriers, effective masses of density of states, nonparabolicity of the conduction and valence bands, g-factor and its anisotropy for n- and p-CdSb were estimated for the first time during these studies. All the results obtained are compared with the cyclotron resonance data and the corresponding theoretical calculations for p-CdSb. This is basic information for the analyses of the complex transport properties of CdSb and for working out the energy spectrum model of the shallow energy levels of defects and impurities in this semiconductor. It was found out existence of different mechanisms of hopping conductivity in the presence of metal - insulator transition induced by magnetic field in n- and p-CdSb. Quite unusual feature opened in CdSb is that different types of hopping conductivity may take place in the same crystal depending on temperature, magnetic field or even orientation of crystal in magnetic field. Transport properties of undoped p-CdSb samples show that the anisotropy of the resistivity in weak and strong magnetic fields is determined completely by the anisotropy of the effective mass of the holes. Temperature and magnetic field dependence of the Hall coefficient and magnetoresistance is attributed to presence of two groups of holes with different concentrations and mobilities. The analysis demonstrates that below Tcr ~ 20 K and down to ~ 6 - 7 K the low-mobile carriers are itinerant holes with energy E2 ≈ 6 meV. The high-mobile carriers, at all temperatures T < Tcr, are holes activated thermally from a deeper acceptor band to itinerant states of a shallower acceptor band with energy E1 ≈ 3 meV. Analysis of temperature dependences of mobilities confirms the existence of the heavy-hole band or a non-equivalent maximum and two equivalent maxima of the light-hole valence band. Galvanomagnetic effects in n-CdSb reveal the existence of two groups of carriers. These are the electrons of a single minimum in isotropic conduction band and the itinerant electrons of the narrow impurity band, having at low temperatures the energies above the bottom of the conduction band. It is found that above this impurity band exists second impurity band of only localized states and the energy of both impurity bands depend on temperature so that they sink into the band gap when temperature is increased. The bands are splitted by the spin, and in strong magnetic fields the energy difference between them decreases and redistribution of the electrons between the two impurity bands takes place. Mobility of the conduction band carriers demonstrates that scattering in n-CdSb at low temperatures is strongly anisotropic. This is because of domination from scattering on the neutral impurity centers and increasing of the contribution to mobility from scattering by acoustic phonons when temperature increases. Metallic conductivity in zero or weak magnetic field is changed to activated conductivity with increasing of magnetic field. This exhibits a metal-insulator transition (MIT) induced by the magnetic field due to shift of the Fermi level from the interval of extended states to that of the localized states of the electron spectrum near the edge of the conduction band. The Mott variablerange hopping conductivity is observed in the low- and high-field intervals on the insulating side of the MIT. The results yield information about the density of states, the localization radius of the resonant impurity band with completely localized states and about the donor band. In high magnetic fields this band is separated from the conduction band and lies below the resonant impurity bands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä on tutkittu vetojännityskuormituksen alaisena olevien hitsattujen kuormaa kantamattomien X-liitosten hitsin paikallisen geometrian variaation vaikutusta väsymislujuuteen. Muuttujina olivat reunan pyöristyssäde, kylmäjuoksun suuruus ja kylkikulma. Geometristen muuttujien parametrinen riippuvuussuhde on analysoitu usealla elementtimallilla. Väsymistarkastelu on suoritettu käyttämällä lineaaris-elastista murtumismekaniikkaa (LEFM) tasovenymätilassa ja materiaalina terästä. Särönkasvun suunnan ennustamisessaon käytetty maksimipääjännityskriteeriä sekä jännitysintensiteettikertoimet on määritetty J-integraalilla. Särön ydintymisvaihetta ei ole otettu huomioon. Rakenteen on oletettu olevan hitsatussa tilassa ja jännitysheilahdus on kokonaan tehollinen. Särön kasvunopeuden ennustamiseen on käytetty Paris'n lakia. Väsymislujuustulokset on esitetty karakteristisina väsymisluokkina (FAT) ja sovitettu parametriseksi yhtälöksi. Lopuksi väsymisanalyysin ennustamia tuloksia on verrattu saatavilla oleviin väsytystestituloksiin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of buprenorphine and its major metabolite norbuprenorphine in human plasma. In order to speed up the process and decrease costs, sample preparation was performed by simple protein precipitation with acetonitrile. To the best of our knowledge, this is the first application of this extraction technique for the quantification of buprenorphine in plasma. Matrix effects were strongly reduced and selectivity increased by using an efficient chromatographic separation on a sub-2μm column (Acquity UPLC BEH C18 1.7μm, 2.1×50mm) in 5min with a gradient of ammonium formate 20mM pH 3.05 and acetonitrile as mobile phase at a flow rate of 0.4ml/min. Detection was made using a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The procedure was fully validated according to the latest Food and Drug Administration guidelines and the Société Française des Sciences et Techniques Pharmaceutiques. Very good results were obtained by using a stable isotope-labeled internal standard for each analyte, to compensate for the variability due to the extraction and ionization steps. The method was very sensitive with lower limits of quantification of 0.1ng/ml for buprenorphine and 0.25ng/ml for norbuprenorphine. The upper limit of quantification was 250ng/ml for both drugs. Trueness (98.4-113.7%), repeatability (1.9-7.7%), intermediate precision (2.6-7.9%) and internal standard-normalized matrix effects (94-101%) were in accordance with international recommendations. The procedure was successfully used to quantify plasma samples from patients included in a clinical pharmacogenetic study and can be transferred for routine therapeutic drug monitoring in clinical laboratories without further development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High reflectivity to laser light, alloying element evaporation during high power laser welding makes aluminium alloys highly susceptibility to weld defects such as porosity, cracking and undercutting. The dynamic behaviour of the keyhole, due to fluctuating plasma above the keyhole and the vaporization ofthe alloying elements with in the keyhole, is the key problem to be solved for the improvement of the weld quality and stabilization of the keyhole dynamics isperhaps the single most important development that can broaden the application of laser welding of aluminium alloys. In laser welding, the shielding gas is commonly used to stabilize the welding process, to improve the welded joint features and to protect the welded seam from oxidation. The chemicalcomposition of the shielding gas is a key factor in achieving the final qualityof the welded joints. Wide range of shielding gases varying from the pure gasesto complex mixtures based on helium, argon, nitrogen and carbon dioxide are commercially available. These gas mixtures should be considered in terms of their suitability during laser welding of aluminium alloys to produce quality welds. The main objective of the present work is to study the effect of the shielding gascomposition during laser welding of aluminium alloys. Aluminium alloy A15754 was welded using 3kW Nd-YAG laser (continuous wave mode). The alloy samples were butt welded with different shielding gases (pure and mixture of gases) so that high quality welds with high joint efficiencies could be produced. It was observed that the chemical composition of the gases influenced the final weld quality and properties. In general, the mixture gases, in correct proportions, enabled better utilisation of the properties of the mixing gases, stabilized the welding process and produced better weld quality compared to the pure shielding gases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'introduction des technologies de séquençage de nouvelle génération est en vue de révolutionner la médecine moderne. L'impact de ces nouveaux outils a déjà contribué à la découverte de nouveaux gènes et de voies cellulaires impliqués dans la pathologie de maladies génétiques rares ou communes. En revanche, l'énorme quantité de données générées par ces systèmes ainsi que la complexité des analyses bioinformatiques nécessaires, engendre un goulet d'étranglement pour résoudre les cas les plus difficiles. L'objectif de cette thèse a été d'identifier les causes génétiques de deux maladies héréditaires utilisant ces nouvelles techniques de séquençage, couplées à des technologies d'enrichissement de gènes. Dans ce cadre, nous avons développé notre propre méthode de travail (pipeline) pour l'alignement des fragments de séquence (reads). Suite à l'identification de gènes, nous avons réalisé une analyse fonctionnelle pour élucider leur rôle dans la maladie. Dans un premier temps, nous avons étudié et identifié des mutations impliquées dans une forme récessive de la rétinite pigmentaire qui est à ce jour la dégénérescence rétinienne héréditaire la plus fréquente. En particulier, nous avons constaté que des mutations faux-sens dans le gène FAM161A étaient la cause de la rétinite pigmentaire préalablement associé avec le locus RP28. De plus, nous avons démontré que ce gène avait des fonctions au niveau du cil du photorécepteur, complétant le large spectre des cilliopathies rétiniennes héréditaires. Dans un second temps, nous avons exploré la possibilité qu'un syndrome, relativement fréquent en pédiatrie de fièvre récurrente, appelé PFAPA (acronyme de fièvre périodique avec adénite stomatite, pharyngite et cervical aphteuse) puisse avoir une origine génétique. L'étiologie de cette maladie n'étant pas claire, nous avons tenté d'identifier le spectre génétique de patients PFAPA. Comme nous n'avons pas pu mettre à jour un nouveau gène unique muté et responsable de la maladie chez tous les individus dépistés, il semblerait qu'un modèle génétique plus complexe suggérant l'implication de plusieurs gènes dans la pathologie ait été identifié chez les patients touchés. Ces gènes seraient notamment impliqués dans des processus liés à l'inflammation ce qui élargirait l'impact de ces études à d'autres maladies auto-inflammatoires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobiililaitteet ovat kehittyneet merkittävästi viimeisen vuosikymmenen aikana. Ne eivät enää ole pelkästään puhelimia tai kämmentietokoneita, vaan multimediatietokoneita, jotka pystyvät tuottamaan korkealaatuisia elämyksiä käyttäjälleen.Sisällön laadun paraneminen johtaa väistämättä myös siirrettävän tietomäärän kasvamiseen. Siksi uusia, nopeampia tiedonsiirtomenetelmiä on otettava käyttöön. Ultra Wideband (UWB) on uusi radioaaltotekniikka, jokamahdollistaa korkeat tiedonsiirtonopeudet lyhyillä etäisyyksillä. Tekniikka operoi erittäin leveällä 3.1 - 10.6 gigahertsin taajuuskaistalla.UWB on suunnattu nopeaan, langattomaan tiedonsiirtoon personal area networkin (PAN) laitteiden välillä. Tämän diplomityön tarkoituksena on arvioida UWBn soveltuvuutta mobiililaitteisiin. Arviointi tehdään teoreettiselta pohjalta, sillä UWBtä ei vielä ole implementoitu kaupallisiin laitteisiin. Ensin esitellään UWBn tekniikka ja ominaisuudet, jonka jälkeen sen soveltuvuutta arvioidaan esimerkkikäyttötapausten valossa. Esimerkkikäyttötapauksiksi on valittu kolme tyypillistä mutta erilaista toimintoa, jotka mahdollisimman hyvin kuvaavat mobiililaitteiden käyttöä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mangas 'Tommy Atkins' produzidas na região de Ibirá, São Paulo, foram pulverizadas na pré-colheita com cloreto de cálcio, nas concentrações de 0,0%, 2,5% e 5,0%, em três épocas de seu desenvolvimento (40; 60 e 90 dias após a floração) a fim de verificar a influência do cálcio na estrutura da parede celular destes frutos através de microscopia eletrônica de transmissão, imediatamente após a colheita e depois de 35 dias de armazenamento. Para fixar o material da polpa, utilizou-se metodologia descrita por Jacob e Gowanlock (1995). Nas condições experimentais, verificou-se que os frutos do tratamento-controle (sem cloreto de cálcio), no dia da colheita, já apresentavam desestruturação da parede celular e dissolução da lamela média (LM). A degradação da parede celular ocorre inicialmente na LM, levando à formação de espaços vazios bastante distintos, apresentando uma dissolução ainda maior, com o armazenamento prolongado (35 dias). Os frutos tratados com cloreto de cálcio a 5,0% apresentaram uma LM bem definida e ausência de espaços vazios, mesmo após o armazenamento, mostrando ser uma concentração efetiva na preservação da lamela média.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a lack of quick, simple and reliable methods for determination of nanoparticle size. An investigation of the size of hydrophobic (CdSe) and hydrophilic (CdSe/ZnS) quantum dots was performed by using the maximum position of the corresponding fluorescence spectrum. It has been found that fluorescence spectroscopy is a simple and reliable methodology to estimate the size of both quantum dot types. For a given solution, the homogeneity of the size of quantum dots is correlated to the relationship between the fluorescence maximum position (FMP) and the quantum dot size. This methodology can be extended to the other fluorescent nanoparticles. The employment of evolving factor analysis and multivariate curve resolution-alternating least squares for decomposition of the series of quantum dots fluorescence spectra recorded by a specific measuring procedure reveals the number of quantum dot fractions having different diameters. The size of the quantum dots in a particular group is defined by the FMP of the corresponding component in the decomposed spectrum. These results show that a combination of the fluorescence and appropriate statistical method for decomposition of the emission spectra of nanoparticles may be a quick and trusted method for the screening of the inhomogeneity of their solution.