986 resultados para Spray chamber
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Epigallocatechin gallate (EGCG), an antioxidant with several pharmacological and biological activities, was encapsulated in carbohydrate particles to preserve its antioxidant properties and improve its bioavailability. Gum arabic–maltodextrin particles loaded with EGCG (EGCG/P) were successfully produced by homogenization and spray-drying, with an EGCG loading efficiency of 96 ± 3%. Spray-dried particles are spherical or corrugated and polydisperse with diameters less than 20 m. The particles in aqueous suspension revealed two main populations, with mean average diameters of 40 nm and 400 nm. Attenuated total reflection-infrared spectroscopy (ATR-IR) confirmed that EGCG was incorporated in the carbohydrate matrix by intermolecular interactions, maintaining its chemical integrity. Atomic force microscopy imaging proved the particle spherical shape and size. The present study demonstrates that the carbohydrate matrix is able to preserve EGCG antioxidant properties, as proof of concept to be used as polymeric drug carrier.
Resumo:
Resumo I - O projecto “Piano e outros Instrumentos/orquestra” consiste na implementação do formato Piano e Orquestra em complemento às aulas individuais e aos ensaios de conjunto. O trabalho foi dirigido a um grupo de três alunos com idades de 9, 12 e 16 anos, do curso de Iniciação, Básico e Secundário da EMNSC (Escola de Música de Nossa Senhora do Cabo). Foram criados momentos distintos em cada fase. Estimulou-se o desenvolvimento de competências musicais e de estratégias metacognitivas visando a evolução dos alunos e a eficácia na realização do estudo individual. O Projecto foi criado com o objectivo de desenvolver as competências musicais, a motivação para realização do estudo individual e de grupo, o espírito e a audição crítica, o controlo dos factores psicológicos, a ansiedade, o aumento da autoconfiança, a aprendizagem, a melhoria da atitude positiva no momento da execução pública e o incremento do interesse pelas actividades relacionadas com a prática musical. A realização deste projecto visou analisar o grau de motivação, o desenvolvimento e a aquisição de competências musicais dos alunos de piano que frequentaram semanalmente aulas individuais, aulas extra de preparação, ensaios com Orquestra “Da Capo”, ensaios com a Orquestra Maior, duos com violoncelo e com canto. Um dos objectivos era comparar o grau de motivação e desenvolvimento dos alunos quando estudam obras nas aulas individuais que constituem o programa curricular e, por outro lado, quando o fazem em peças seleccionadas especificamente para este Projecto. Esta experiência visou proporcionar um conhecimento nos diversos domínios da música, uma visão diferente da funcionalidade do piano em conjunto com os outros instrumentos, a descoberta das sonoridades do piano contrastante e ao mesmo tempo, integrante com outros instrumentos, as formas de funcionamento dos instrumentos de corda, de sopro, dos assuntos relacionados com a afinação e pretendendo-se assim apurar o sentido de fazer parte integrante de um todo.
Resumo:
Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Imagem Digital com Radiação X
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
This work presents the results of the experimental study of proton induced nuclear reactions in lithium, namely the 7Li(p,α) 4He, 6Li(p,α) 3He and 7Li(p,p)7Li reactions. The amount of 7Li and 6Li identified as primordial and observed in very old stars of the Milky Way galactic halo strongly deviates from the predictions of primordial nucleosynthesis and stellar evolution models which depend, among other factors, on the cross sections of reactions like 7Li(p,α) 4He and 6Li(p,α) 3He. These discrepancies have triggered a large amount of research in the fields of stellar evolution, cosmology, pre-galactic evolution and low energy nuclear reactions. Focusing on nuclear reactions, this work has measured the 7Li(p,α) 4He and 6Li(p,α) 3He reactions cross sections (expressed in terms of the astrophysical S -factor) with higher accuracy, and the electron screening effects in these reactions for different environments (insulators and metallic targets). The 7Li(p,α) 4He angular distributions were also measured. These measurementstook place in two laboratory facilities, in the framework of the LUNA (Laboratory for Undergroud Nuclear Astrophysics) international collaboration, namely the Laboratorio ´ de Feixe de Ioes ˜ in ITN (Instituto Tecnologico ´ e Nuclear) Sacavem, ´ Portugal, and the Dynamitron-TandemLaboratorium in Ruhr-Universitat¨ Bochum, Germany. The ITN target chamber was modified to measure these nuclear reactions, with the design and construction of new components, the addition of one turbomolecular pump and a cold finger. The 7Li(p,α) 4He and 6Li(p,α) 3He reactions were measured concurrently with seven and four targets, respectively. These targets were produced in order to obtain adequate and stable lithium depth profiles. In metallic environments, the measured electron screening potential energies are much higher than the predictions of atomic-physics models. The Debye screening model applied to the metallic conduction electrons is able to explain these high values. It is a simple model, but also very robust. Concerning primordial nucleosynthesis and stellar evolution models, these results are very important as they show that laboratory measurements are well controlled, and the model inputs from these cross sections are therefore correct. In this work the 7Li(p,p)7Li differential cross section was also measured, which is useful to describe the 7Li(p,α) 4He entrance channel.
Resumo:
The chemical and mineralogical charactetistics of the intrusive and extrusive rocks of this igneous complex are presented. The suggest affinities between these rocks. The major and the trace elements lead us to conclude that these rocks were originated in a common magmatic chamber by fractional crystallization.
Resumo:
Shape Memory Alloy (SMA) Ni-Ti films have attracted much interest as functional and smart materials due to their unique properties. However, there are still important issues unresolved like formation of film texture and its control as well as substrate effects. Thus, the main challenge is not only the control of the microstructure, including stoichiometry and precipitates, but also the identification and control of the preferential orientation since it is a crucial factor in determining the shape memory behaviour. The aim of this PhD thesis is to study the optimisation of the deposition conditions of films of Ni-Ti in order to obtain the material fully crystallized at the end of the deposition, and to establish a clear relationship between the substrates and texture development. In order to achieve this objective, a two-magnetron sputter deposition chamber has been used allowing to heat and to apply a bias voltage to the substrate. It can be mounted into the six-circle diffractometer of the Rossendorf Beamline (ROBL) at the European Synchrotron Radiation Facility (ESRF), Grenoble, France, enabling an in-situ characterization by X-ray diffraction(XRD) of the films during their growth and annealing. The in-situ studies enable us to identify the different steps of the structural evolution during deposition with a set of parameters as well as to evaluate the effect of changing parameters on the structural characteristics of the deposited film. Besides the in-situ studies, other complementary ex-situ characterization techniques such as XRD at a laboratory source, Rutherford backscattering spectroscopy(RBS), Auger electron spectroscopy (AES), cross-sectional transmission electron microscopy (X-TEM), scanning electron microscopy (SEM), and electrical resistivity (ER) measurements during temperature cycling have been used for a fine structural characterization. In this study, mainly naturally and thermally oxidized Si(100) substrates, TiN buffer layers with different thicknesses (i.e. the TiN topmost layer crystallographic orientation is thickness dependent) and MgO(100) single crystals were used as substrates. The chosen experimental procedure led to a controlled composition and preferential orientation of the films. The type of substrate plays an important role for the texture of the sputtered Ni-Ti films and according to the ER results, the distinct crystallographic orientations of the Ni-Ti films influence their phase transformation characteristics.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
OBJECTIVE Analyze the implementation of drug price regulation policy by the Drug Market Regulation Chamber.METHODS This is an interview-based study, which was undertaken in 2012, using semi-structured questionnaires with social actors from the pharmaceutical market, the pharmaceuticals industry, consumers and the regulatory agency. In addition, drug prices were compiled based on surveys conducted in the state of Sao Paulo, at the point of sale, between February 2009 and May 2012.RESULTS The mean drug prices charged at the point of sale (pharmacies) were well below the maximum price to the consumer, compared with many drugs sold in Brazil. Between 2009 and 2012, 44 of the 129 prices, corresponding to 99 drugs listed in the database of compiled prices, showed a variation of more than 20.0% in the mean prices at the point of sale and the maximum price to the consumer. In addition, many laboratories have refused to apply the price adequacy coefficient in their sales to government agencies.CONCLUSIONS The regulation implemented by the pharmaceutical market regulator was unable to significantly control prices of marketed drugs, without succeeding to push them to levels lower than those determined by the pharmaceutical industry and failing, therefore, in its objective to promote pharmaceutical support for the public. It is necessary reconstruct the regulatory law to allow market prices to be reduced by the regulator as well as institutional strengthen this government body.
Resumo:
Journal of Applied Physics, Vol. 96, nº3
Resumo:
Vacuum, Vol. 64
Resumo:
Trabalho final de Mestrado para obtenção do grau de mestre em Engenharia Mecânica Ramo de Energia, Refrigeração e Climatização