839 resultados para Spectrum sensing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Descrever o recrutamento de pacientes, instrumentos de avaliação, métodos para o desenvolvimento de estudos colaborativos multicêntricos e os resultados preliminares do Consórcio Brasileiro de Pesquisa em Transtornos do Espectro Obsessivo-Compulsivo, que inclui sete centros universitários. MÉTODO: Este estudo transversal incluiu entrevistas semi-estruturadas (dados sociodemográficos, histórico médico e psiquiátrico, curso da doença e diagnósticos psiquiátricos comórbidos) e instrumentos que avaliam os sintomas do transtorno obsessivo-compulsivo (Escala para Sintomas Obsessivo-Compulsivos de Yale-Brown e Escala Dimensional para Sintomas Obsessivo-Compulsivos de Yale-Brown), sintomas depressivos (Inventário de Depressão de Beck), sintomas ansiosos (Inventário de Ansiedade de Beck), fenômenos sensoriais (Escala de Fenômenos Sensoriais da Universidade de São Paulo), juízo crítico (Escala de Avaliação de Crenças de Brown), tiques (Escala de Gravidade Global de Tiques de Yale) e qualidade de vida (questionário genérico de avaliação de qualidade de vida, Medical Outcome Quality of Life Scale Short-form-36 e Escala de Avaliação Social). O treinamento dos avaliadores consistiu em assistir cinco entrevistas filmadas e entrevistar cinco pacientes junto com um pesquisador mais experiente, antes de entrevistar pacientes sozinhos. A confiabilidade entre todos os líderes de grupo para os instrumentos mais importantes (Structured Clinical Interview for DSM-IV, Dimensional Yale-Brown Obsessive-Compulsive Scale, Universidade de São Paulo Sensory Phenomena Scale ) foi medida após seis entrevistas completas. RESULTADOS: A confiabilidade entre avaliadores foi de 96%. Até março de 2008, 630 pacientes com transtorno obsessivo-compulsivo tinham sido sistematicamente avaliados. A média de idade (±SE) foi de 34,7 (±0,51), 56,3% eram do sexo feminino e 84,6% caucasianos. Os sintomas obsessivo-compulsivos mais prevalentes foram os de simetria e os de contaminação. As comorbidades psiquiátricas mais comuns foram depressão maior, ansiedade generalizada e transtorno de ansiedade social. O transtorno de controle de impulsos mais comum foi escoriação neurótica. CONCLUSÃO: Este consórcio de pesquisa, pioneiro no Brasil, permitiu delinear o perfil sociodemográfico, clínico e terapêutico do paciente com transtorno obsessivo-compulsivo em uma grande amostra clínica de pacientes. O Consórcio Brasileiro de Pesquisa em Transtornos do Espectro Obsessivo-Compulsivo estabeleceu uma importante rede de colaboração de investigação clínica padronizada sobre o transtorno obsessivo-compulsivo e pode abrir o caminho para projetos semelhantes destinados a integrar outros grupos de pesquisa no Brasil e em todo o mundo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IR-spectrum of the isonicotinamide molecule (C(2)H(2)NC(3)H(2)CONH(2)) is studied by means of theoretical and experimental methods. For an appropriate representation of the molecular environment, Gaussian basis sets to the atoms of these molecule are built and then contracted (5s and 6s5p). For evaluation of the quality of contracted basis sets in molecular calculations, we have accomplished calculations of the total and the orbital (HOMO and HOMO-1) energies in the HF-Roothaan method for the molecule studied. The results obtained with the contracted basis sets [5s/6s5p] are compared to values obtained with our (21s/22s14p) basis sets and with those obtained with the D95, 6-31G, and 6-311G basis sets from literature. It was added one d polarization function in the [6s5p] contracted basis set for C ((3)P) atom, which was used in combination with the basis sets for H ((2)S), N ((4)S). and O((3)P) atoms to calculate the infrared spectrum of isonicotinamide. The calculations were performed at B3LYP level and were compared to corresponding experimental values also obtained in our laboratory. The theoretical results in comparison with the corresponding experimental values indicate a very good interpretation of the IR-spectrum and that the strategy of an appropriate representation of the molecular environment through the basis sets is an effective alternative to investigate vibrational theoretical properties of the nicotinamide molecule. (c) 2006 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilayered nanostructured films have been widely investigated for electrochemical applications as modified electrodes, including the layer-by-layer (LbL) films where properties such as thickness and film architecture can be controlled at the molecular level. In this study, we investigate the electrochemical features of LbL films of poly (o-methoxyaniline; POMA) and tetrasulfonated phthalocyanines containing nickel (NiTsPc) or copper (CuTsPc). The films displayed well-defined electroactivity, with redox pairs at 156 and 347 mV vs SCE, characteristic of POMA, which allowed their use as modified electrodes for detecting dopamine and ascorbic acid at concentrations as low as 10(-5) M.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The in vitro activity of cefepime was compared to that of ceftazidime, ceftriaxone, and cefotaxime in a multicenter study involving 10 clinical microbiology laboratories and clinical isolates from 18 Brazilian hospitals from 7 cities (4 states). A total of 982 isolates consecutively collected between December 1995 and March 1996 were susceptibility tested by using Etest and following the NCCLS procedures for agar diffusion tests. The cefepime spectrum was broader than that of the other broad-spectrum cephalosporins against both Gram-negative rods and Gram-positive cocci. Cefepime tons particularly move active against Enterobacter sp. (MIC90, 2 mu g/ml), Serratia sp. (MIC90, 2 mu g/ml) and oxacillin-susceptible Staphylococcus aureus (MIC90, 3 mu g/ml). Against Pseudomonas aeruginosa, cefepime (MIC90 16 mu g/ml) was slightly more active than ceftazidime (MIC90 32 mu g/ml) and 8- to 16-fold more active than ceftriaxone or cefotaxime (MIC90 >256 mu g/ml). Our results show that nosocomial bacteria, especially Gram-negative rods, have a high rate of cephalosporin resistance in Brazil. However, part of these resistant bacteria remains susceptible to cefepime. The Etest was shown to be an excellent method for multicenter studies of the in vitro evaluation of new antimicrobial agents. (C) 1997 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Langmuir-Blodgett (LB) films from a ruthenium complex, mer-[RuCl3(dppb)(py)] (dppb = PPh2(CH2)(4)PPh2; py = pyridine) (Rupy), and from mixtures with varied amounts of polyaniline (PANi) were fabricated. Molecular-level interactions between the two components are investigated by surface potential, dc conductivity and Raman spectroscopy measurements, particularly for the mixed film with 10% of Rupy. For the latter, the better miscibility led to an interaction with Rupy inducing a decrease in the conducting state of PANi, as observed in the Raman spectra and conductivity measurement. The interaction causes the final film properties to depend on the concentration of Rupy, and this was exploited to produce a sensor array made up of sensing units consisting of 11-layer LB films from pure PANi, pure Rupy and mixtures with 10 and 30% of Rupy. It is shown that the combination of only four non-specific sensing units allows one to distinguish the basic tastes detected by biological systems, viz. saltiness, sweetness, sourness and bitterness, at the muM level. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have obtained the photoconductivity (PC) excitation spectrum for a stretch-oriented poly(paraphenylene vinylene) film over a wide spectral range (up to 5 eV). The measurements were performed in the surface cell configuration with the electric field parallel or perpendicular to the stretch direction. Although the sample had a stretch ratio of similar to 4, the dark conductivity and the steady-state photoconductivity were both about 40 and 20 times higher with the electric field parallel to the average chain direction, respectively. However, the shape of the PC excitation spectrum was independent of field direction and did not show a significant rise in the ultraviolet, as is usually observed for measurements in the photodiode configuration. The implications of these results to the charge photogeneration mechanism in conjugated polymers are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanostructured films of lignin (macromolecule extracted from sugar cane bagasse), polypyrrole (conducting polymer) and bis butylimido perylene (organic dye) were used in the detection of trace levels of fluorine (from H2SiF6), chlorine (from NaCIO), Pb+2, Cu+2, and Cd+2 in aqueous solutions. Langmuir monolayers on ultrapure water were characterised by surface pressure-mean molecular area (II-A) isotherms. Langmuir-Blodgett (LB) films were transferred onto gold interdigitated electrodes and used as individual sensing units of an electronic tongue system. Impedance spectroscopy measurements were taken with the sensor immersed into aqueous solutions containing the ions described above in different molar concentrations. Fourier transform infrared absorption (FTIR) was employed to identify possible interactions between the LB films and the analytes in solution, and no significant changes could be observed in the FTIR spectra of BuPTCD and Ppy. Therefore, the results for lignin point to an interaction involving the electronic cloud of the phenyl groups with the metallic ions.