987 resultados para Significant differences
Resumo:
The amount of fat is a component that complicates the clinical evaluation and the differential diagnostic between benign and malign lesions in the breast MRI examinations. To overcome this problem, an effective erasing of the fat signal over the images acquisition process, is essentials. This study aims to compare three fat suppression techniques (STIR, SPIR, SPAIR) in the MR images of the breast and to evaluate the best image quality regarding its clinical usefulness. To mimic breast women, a breast phantom was constructed. First the exterior contour and, in second time, its content which was selected based on 7 samples with different components. Finally it was undergone to a MRI breast protocol with the three different fat saturation techniques. The examinations were performed on a 1.5 T MRI system (Philips®). A group of 5 experts evaluated 9 sequences, 3 of each with fat suppression techniques, in which the frequency offset and TI (Inversion Time) were the variables changed. This qualitative image analysis was performed according 4 parameters (saturation uniformity, saturation efficacy, detail of the anatomical structures and differentiation between the fibroglandular and adipose tissue), using a five-point Likert scale. The statistics analysis showed that anyone of the fat suppression techniques demonstrated significant differences compared to the others with (p > 0.05) and regarding each parameter independently. By Fleiss’ kappa coefficient there was a good agreement among observers P(e) = 0.68. When comparing STIR, SPIR and SPAIR techniques it was confirmed that all of them have advantages in the study of the breast MRI. For the studied parameters, the results through the Friedman Test showed that there are similar advantages applying anyone of these techniques.
Resumo:
Introdução – Os estudos Gated – Single Photon Emission Computed Tomography (SPECT) são uma das técnicas de imagiologia cardíaca que mais evoluiu nas últimas décadas. Para a análise das imagens obtidas, a utilização de softwares de quantificação leva a um aumento da reprodutibilidade e exatidão das interpretações. O objetivo deste estudo consiste em avaliar, em estudos Gated-SPECT, a variabilidade intra e interoperador de parâmetros quantitativos de função e perfusão do miocárdio, obtidos com os softwares Quantitative Gated SPECT (QGS) e Quantitative Perfusion SPECT (QPS). Material e métodos – Recorreu-se a uma amostra não probabilística por conveniência de 52 pacientes, que realizaram estudos Gated-SPECT do miocárdio por razões clínicas e que integravam a base de dados da estação de processamento da Xeleris da ESTeSL. Os cinquenta e dois estudos foram divididos em dois grupos distintos: Grupo I (GI) de 17 pacientes com imagens com perfusão do miocárdio normal; Grupo II (GII) de 35 pacientes que apresentavam defeito de perfusão nas imagens Gated-SPECT. Todos os estudos foram processados 5 vezes por 4 operadores independentes (com experiência de 3 anos em Serviços de Medicina Nuclear com casuística média de 15 exames/semana de estudos Gated-SPECT). Para a avaliação da variabilidade intra e interoperador foi utilizado o teste estatístico de Friedman, considerando α=0,01. Resultados e discussão – Para todos os parâmetros avaliados, os respectivos valores de p não traduziram diferenças estatisticamente significativas (p>α). Assim, não foi verificada variabilidade intra ou interoperador significativa no processamento dos estudos Gated-SPECT do miocárdio. Conclusão – Os softwares QGS e QPS são reprodutíveis na quantificação dos parâmetros de função e perfusão avaliados, não existindo variabilidade introduzida pelo operador.
Resumo:
Introdução – A tomografia de emissão de fotão simples sincronizada com o sinal eletrocardiográfico (Gated-SPECT) é essencial para a avaliação conjunta da perfusão e da função ventricular esquerda (VE) do miocárdio. Objetivo – Investigar a relação entre a função VE e o índice de captação (IC) miocárdio/pulmão direito (M/PD) e M/P esquerdo (M/PE) nos estudos Gated-SPECT com 99mTc-Tetrofosmina. Metodologia – Amostra de 32 pacientes que realizaram estudos Gated-SPECT por indicação clínica, sendo subdividida em dois grupos: Grupo I (GI) – pacientes com a informação clínica de enfarte agudo do miocárdio (EAM); Grupo II (GII) – pacientes com a informação clínica de isquemia. Por cada paciente adquiriram-se imagens estáticas torácico-abdominais e dois estudos Gated-SPECT do miocárdio (protocolo de um dia esforço/repouso). Nas imagens estáticas
definiram-se regiões de interesse (Regions of interest – ROI) para calcular os IC. Nos estudos Gated-SPECT utilizou-se o software Quantitative Gated SPECT/Quantitative Perfusion SPECT para calcular a Fração de Ejeção do Ventrículo Esquerdo (FEVE). Efetuou-se análise estatística descritiva para caracterização da amostra. Aplicou-se o teste de Spearman para avaliar a correlação entre a FEVE e os IC por grupo de pacientes. O Teste de Willcoxon foi usado para comparar FEVE em repouso e em esforço. Resultados – Nos estudos Gated-SPECT em esforço não se verificou correlação estatisticamente significativa entre a FEVE e os IC, para GI e GII; em repouso existe correlação positiva estatisticamente significativa entre a FEVE e os IC, para GI; para GII não se verificou correlação. Na comparação dos valores de FEVE em esforço e repouso nos dois grupos constatou-se a existência de diferenças estatisticamente significativas, sendo a FEVE em Esforço
Resumo:
Perceber a rede estrutural formada pelos neurónios no cérebro a nível da macro escala é um desafio atual na área das neurociências. Neste estudo analisou-se a conectividade estrutural do cérebro em 22 indivíduos saudáveis e em dois doentes com epilepsia pós-traumática. Avaliaram-se as diferenças entre estes dois grupos. Também se pesquisaram diferenças a nível do género e idade no grupo de indivíduos saudáveis e os que têm valores médios mais elevados nas métricas de caracterização da rede. Para tal, desenvolveu-se um protocolo de análise recorrendo a diversos softwares especializados e usaram-se métricas da Teoria dos Grafos para a caracterização da conectividade estrutural entre 118 regiões encefálicas distintas. Dentro do grupo dos indivíduos saudáveis concluiu-se que os homens, no geral, são os que têm média mais alta para as métricas de caracterização da rede estrutural. Contudo, não se observaram diferenças significativas em relação ao género nas métricas de caracterização global do cérebro. Relativamente à idade, esta correlaciona-se negativamente, no geral, com as métricas de caracterização da rede estrutural. As regiões onde se observaram as diferenças mais importantes entre indivíduos saudáveis e doentes são: o sulco rolândico, o hipocampo, o pré-cuneus, o tálamo e o cerebelo bilateralmente. Estas diferenças são consistentes com as imagens radiológicas dos doentes e com a literatura estudada sobre a epilepsia pós-traumática. Preveem-se desenvolvimentos para o estudo da conectividade estrutural do cérebro humano, uma vez que a sua potencialidade pode ser combinada com outros métodos de modo a caracterizar as alterações dos circuitos cerebrais.
Resumo:
Introdução – O presente estudo avaliou o efeito da cafeína no valor da razão contraste ruído (CNR) em imagens SWI. Objetivos – Avaliar o efeito da cafeína qualitativamente e quantificado pelo cálculo do valor CNR em imagens de magnitude e MIP para as estruturas: veia cerebral interna, seio sagital superior, tórcula e artéria cerebral média. Metodologia – A população do estudo incluiu 24 voluntários saudáveis que estiveram pelo menos 24h privados da ingestão de cafeína. Adquiriram-se imagens SWI antes e após a ingestão de 100ml de café. Os voluntários foram subdivididos em quatro grupos de seis indivíduos/grupo e avaliados separadamente após decorrido um intervalo de tempo diferente para cada grupo (15, 25, 30 ou 45min pós-cafeína). Utilizou-se um scanner Siemens Avanto 1,5 T com bobine standard de crânio e os parâmetros: T2* GRE 3D de alta resolução no plano axial, TR=49; TE=40; FA=15; FOV=187x230; matriz=221x320. O processamento de imagem foi efetuado no software OsiriX® e a análise estatística no GraphPadPrism®. Resultados e Discussão – As alterações de sinal e diferenças de contraste predominaram nas estruturas venosas e não foram significantes na substância branca, LCR e artéria cerebral média. Os valores CNR pré-cafeína diferiram significativamente do pós-cafeína nas imagens de magnitude e MIP na veia cerebral interna e nas imagens de magnitude do seio sagital superior e da tórcula (p<0,0001). Não se verificaram diferenças significativas entre os grupos avaliados nos diferentes tempos pós-cafeína. Conclusões – Especulamos que a cafeína possa vir a ser usada como agente de contraste nas imagens SWI barato, eficaz e de fácil administração.
Resumo:
Mestrado em Auditoria
Resumo:
Several antineoplastic drugs have been classified as carcinogens by the International Agency for Research on Cancer (IARC) on the basis of epidemiological findings, animal carcinogenicity data, and outcomes of in vitro genotoxicity studies. 5-Fluorouracil (5-FU), which is easily absorbed through the skin, is the most frequently used antineoplastic agent in Portuguese hospitals and therefore may be used as an indicator of surface contamination. The aims of the present investigation were to (1) examine surface contamination by 5-FU and (2) assess the genotoxic risk using cytokinesis-block micronucleus assay in nurses from two Portuguese hospitals. The study consisted of 2 groups: 27 nurses occupationally exposed to cytostatic agents (cases) and 111 unexposed individuals (controls). Peripheral blood lymphocytes (PBL) were collected in order to measure micronuclei (MN) in both groups. Hospital B showed a higher numerical level of contamination but not significantly different from Hospital A. However; Hospital A presented the highest value of contamination and also a higher proportion of contaminated samples. The mean frequency of MN was significantly higher in exposed workers compared with controls. No significant differences were found among MN levels between the two hospitals. The analysis of confounding factors showed that age is a significant variable in MN frequency occurrence. Data suggest that there is a potential genotoxic damage related to occupational exposure to cytostatic drugs in oncology nurses.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
O estudo teve como objectivo comparar o impacto do estigma e do bem-estar subjectivo em pessoas com diferentes doenças crónicas. Foram avaliados 729 doentes, recrutados em hospitais de Portugal, que após o diagnóstico retomaram a sua vida normal. Controlando para um conjunto de variáveis sócio-demográficas e clínicas, a aplicação de Modelos de Análise de Covariância Multivariada, permitiu verificar diferenças significativas apenas para a percepção do estigma entre os grupos de doenças crónicas. Pessoas com obesidade, epilepsia e esclerose múltipla referem mais estigma e pessoas com diabetes tipo1 e miastenia gravis referem menos estigma.
Resumo:
QuEChERS method was evaluated for extraction of 16 PAHs from fish samples. For a selective measurement of the compounds, extracts were analysed by LC with fluorescence detection. The overall analytical procedure was validated by systematic recovery experiments at three levels and by using the standard reference material SRM 2977 (mussel tissue). The targeted contaminants, except naphthalene and acenaphthene, were successfully extracted from SRM 2977 with recoveries ranging from 63.5–110.0% with variation coefficients not exceeding 8%. The optimum QuEChERS conditions were the following: 5 g of homogenised fish sample, 10 mL of ACN, agitation performed by vortex during 3 min. Quantification limits ranging from 0.12– 1.90 ng/g wet weight (0.30–4.70 µg/L) were obtained. The optimized methodology was applied to assess the safety concerning PAHs contents of horse mackerel (Trachurus trachurus), chub mackerel (Scomber japonicus), sardine (Sardina pilchardus) and farmed seabass (Dicentrarchus labrax). Although benzo(a)pyrene, the marker used for evaluating the carcinogenic risk of PAHs in food, was not detected in the analysed samples (89 individuals corresponding to 27 homogenized samples), the overall mean concentration ranged from 2.52 l 1.20 ng/g in horse mackerel to 14.6 ± 2.8 ng/ g in farmed seabass. Significant differences were found between the mean PAHs concentrations of the four groups.
Resumo:
Concentrations of eleven trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) were measured in 39 (natural and flavoured) water samples. Determinations were performed using graphite furnace electrothermetry for almost all elements (Al, As, Cd, Cr, Co, Mn, Ni, Pb, and Si). For Se determination hydride generation was used, and cold vapour generation for Hg. These techniques were coupled to atomic absorption spectrophotometry. The trace element content of still or sparkling natural waters changed from brand to brand. Significant differences between natural still and natural sparkling waters (p<0.001) were only apparent for Mn. The Mann–Whitney U-test was used to search for significant differences between flavoured and natural waters. The concentration of each element was compared with the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. It was shown that flavoured waters generally increase the trace element content. The addition of preservatives and acidifying regulators had a significant influence on Mn, Co, As and Si contents (p<0.05). Fruit juice can also be correlated to the increase of Co and As. Sweeteners did not provide any significant difference in Mn, Co, Se and Si content.
Flavoured versus natural waters: macromineral (Ca, Mg, K, Na) and micromineral (Fe, Cu, Zn) contents
Resumo:
Macro (Ca, Mg, K, Na) and micromineral (Fe, Zn, Cu) composition of 39 waters was analysed. Determinations were made by atomic flame spectrophotometry for macrominerals and electrothermic atomisation in graphite furnace for microminerals. Mineral contents of still or sparkling natural waters (without flavours) changed from brand to brand. Mann–Whitney test was used to search for significant differences between flavoured and natural waters. For that, the concentration of each mineral was compared to the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. The statistical study demonstrated that flavoured waters generally have increased contents of K, Na, Fe and Cu. The added preservatives also led to significant differences in the mineral composition. Acidifying agents and fruit juice can also be correlated to the increase of Mg, K, Na, Fe and Cu. Sweeteners do not provide any significant difference in Ca, Mg, Fe and Zn contents.
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular