964 resultados para SE Brazilian coast (23 degrees S and 42 degrees W)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim  To report the prevalence, clinical associations, and trends over time of oromotor dysfunction and communication impairments in children with cerebral palsy (CP).

Method  Multiple sources of ascertainment were used and children followed up with a standardized assessment including motor speech problems, swallowing/chewing difficulties, excessive drooling, and communication impairments at age 5 years.

Results  A total of 1357 children born between 1980 and 2001 were studied (781 males, 576 females; median age 5y 11mo, interquartile range 3–9y; unilateral spastic CP, n=447; bilateral spastic CP, n=496; other, n=112; Gross Motor Function Classification System [GMFCS] level: I, 181; II, 563; III, 123; IV, 82; IV, 276). Of those with ‘early-onset’ CP (n=1268), 36% had motor speech problems, 21% had swallowing/chewing difficulties, 22% had excessive drooling, and 42% had communication impairments (excluding articulation defects). All impairments were significantly related to poorer gross motor function and intellectual impairment. In addition, motor speech problems were related to clinical subtype; swallowing/chewing problems and communication impairments to early mortality; and communication impairments to the presence of seizures. Of those with CP in GMFCS levels IV to V, a significant proportion showed a decline in the rate of motor speech impairment (p=0.008) and excessive drooling (p=0.009) over time.

Interpretation  These impairments are common in children with CP and are associated with poorer gross motor function and intellectual impairment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leventhal's common sense model has provided a useful framework for explaining psychological distress in several chronic illnesses. The model indicates that a person's perception of their illness and their coping strategies are the key determinants of their experience of psychological distress. The present research examines whether illness perceptions and coping strategies are related to levels of psychological distress among survivors of esophageal cancer. Everyone registered with the Oesophageal Patients' Association in the UK was mailed a questionnaire booklet, which included the Illness Perception Questionnaire-Revised, the Cancer Coping Questionnaire, and the Hospital Anxiety and Depression Scale. Complete responses were received from 484 people. Regression models indicated that the variables measured could explain 51% of the variance in anxiety and 42% of the variance in depression. Perceptions of esophageal cancer explained the majority of this variance. Positive focus coping strategies were also found to be important in explaining psychological distress. The results of this study are consistent with previous research demonstrating that illness perceptions are stronger correlates of adaptive outcomes than coping strategies. The findings suggest that cognition-based interventions could potentially be most effective in minimizing emotional distress among survivors of esophageal cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To characterize and map temporal changes in the biological and clinical phenotype during a 21-day experimental gingivitis study. Materials and Methods: Experimental gingivitis was induced over 21 days in healthy human volunteers (n = 56), after which normal brushing was resumed (resolution phase). Gingival and plaque indices were assessed. Gingival crevicular fluid was collected from four paired test and contra-lateral control sites in each volunteer during induction (Days 0, 7, 14 and 21) and resolution (Days 28 and 42) of experimental gingivitis. Fluid volumes were measured and a single analyte was quantified from each site-specific, 30s sample. Data were evaluated by analysis of repeated measurements and paired sample tests. Results: Clinical indices and gingival crevicular fluid volumes at test sites increased from Day 0, peaking at Day 21 (test/control differences all p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have surveyed the frequency band 218.30-263.55 GHz toward the core positions N and M and the quiescent cloud position NW in the Sgr B2 molecular cloud using the Swedish-ESO Submillimetre Telescope. In total 1730, 660, and 110 lines were detected in N, M, and NW, respectively, and 42 different molecular species were identified. The number of unidentified lines are 337, 51, and eight. Toward the N source, spectral line emission constitutes 22% of the total detected flux in the observed band, and complex organic molecules are the main contributors. Toward M, 14% of the broadband flux is caused by lines, and SO2 is here the dominant source of emission. NW is relatively poor in spectral lines and continuum. In this paper we present the spectra together with tables of suggested line identifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, the physicochemical properties and preliminary in vivo clinical performance of formulations containing hydroxyethylcellulose (HEC; 3, 5, 10% w/w, poly(vinylpyrrolidone) (PVP; 3, 5% w/w), polycarbophil (PC; 1, 3, 5% w/w), and flurbiprofen (5% w/w) were examined. Flurbiprofen release into PBS pH 7.4 was performed at 37 degrees C. The mechanical properties (hardness, compressibility, adhesiveness, initial stress) and syringeability of formulations were determined using a texture analyzer in texture profile analysis (TPA) and compression modes, respectively. In general, the time required for release of 10 and 30% of the original mass of flurbiprofen (t(10%), t(30%)) increased as the concentration of each polymeric component increased. However, in the presence of either 5 or 10% HEC and 5% PC, increased PVP concentration decreased both t(10%), t(30%) due to excessive swelling land disintegration) of these formulations. Increased concentrations of HEC, PVP, and PC significantly increased formulation hardness, compressibility, work of syringe expression, and initial stress due to the effects of these polymers on formulation viscoelasticity. Similarly, increased concentrations of PC (primarily), HEC, and PVP increased formulation adhesiveness-due to the known bioadhesive properties of these polymers. Clinical efficacies of formulations containing 3% HEC, 3% PVP, 3% PC, and either 0% (control) of 5% (test) flurbiprofen, selected to offer optimal drug release and mechanical properties, were evaluated and clinically compared in an experimental gingivitis model. The test (flurbiprofen-containing) formulation significantly reduced gingival inflammation, as evaluated using the gingival index, and the gingival crevicular fluid volume, whereas, these clinical parameters were generally increased in volunteers who had received the control formulation. There were no observed differences in the plaque indices of the two subject groups, confirming that the observed differences in gingival inflammation could not be accredited to differences in plaque accummulation. This study has shown both the applicability of the in vitro methods used, particularly TPA, for the rational selection of formulations for clinical evaluation and, additionally, the clinical benefits of the topical application of a bioadhesive semisolid flurbiprofen-containing formulation for the treatment of experimental gingivitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unlabelled single- and double-stranded DNA (ssDNA and dsDNA, respectively) has been detected at concentrations =10-9?M by surface-enhanced Raman spectroscopy. Under appropriate conditions the sequences spontaneously adsorbed to the surface of both Ag and Au colloids through their nucleobases; this allowed highly reproducible spectra with good signal-to-noise ratios to be recorded on completely unmodified samples. This eliminated the need to promote absorption by introducing external linkers, such as thiols. The spectra of model ssDNA sequences contained bands of all the bases present and showed systematic changes when the overall base composition was altered. Initial tests also showed that small but reproducible changes could be detected between oligonucleotides with the same bases arranged in a different order. The spectra of five ssDNA sequences that correspond to different strains of the Escherichia coli bacterium were found to be sufficiently composition-dependent so that they could be differentiated without the need for any advanced multivariate data analysis techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To determine whether 80-lead body surface potential mapping (BSPM) improves detection of acute coronary artery occlusion in patients presenting with out-of-hospital cardiac arrest (OHCA) due to ventricular fibrillation (VF) and who survived to reach hospital. Methods and results: Of 645 consecutive patients with OHCA who were attended by the mobile coronary care unit, VF was the initial rhythm in 168 patients. Eighty patients survived initial resuscitation, 59 of these having had BSPM and 12-lead ECG post-return of spontaneous circulation (ROSC) and in 35 patients (age 69±13 yrs; 60% male) coronary angiography performed within 24. h post-ROSC. Of these, 26 (74%) patients had an acutely occluded coronary artery (TIMI flow grade [TFG] 0/1) at angiography. Twelve-lead ECG criteria showed ST-segment elevation (STE) myocardial infarction (STEMI) using Minnesota 9-2 criteria - sensitivity 19%, specificity 100%; ST-segment depression (STD) =0.05. mV in =2 contiguous leads - sensitivity 23%, specificity 89%; and, combination of STEMI or STD criteria - sensitivity 46%, specificity 100%. BSPM STE occurred in 23 (66%) patients. For the diagnosis of TFG 0/1 in a main coronary artery, BSPM STE had sensitivity 88% and specificity 100% (c-statistic 0.94), with STE occurring most commonly in either the posterior, right ventricular or high right anterior territories. Conclusion: Among OHCA patients presenting with VF and who survived resuscitation to reach hospital, post-resuscitation BSPM STE identifies acute coronary occlusion with sensitivity 88% and specificity 100% (c-statistic 0.94). © 2012 Elsevier Ireland Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES:: We assessed the effectiveness of ToT from VR laparoscopic simulation training in 2 studies. In a second study, we also assessed the TER. ToT is a detectable performance improvement between equivalent groups, and TER is the observed percentage performance differences between 2 matched groups carrying out the same task but with 1 group pretrained on VR simulation. Concordance between simulated and in-vivo procedure performance was also assessed. DESIGN:: Prospective, randomized, and blinded. PARTICIPANTS:: In Study 1, experienced laparoscopic surgeons (n = 195) and in Study 2 laparoscopic novices (n = 30) were randomized to either train on VR simulation before completing an equivalent real-world task or complete the real-world task only. RESULTS:: Experienced laparoscopic surgeons and novices who trained on the simulator performed significantly better than their controls, thus demonstrating ToT. Their performance showed a TER between 7% and 42% from the virtual to the real tasks. Simulation training impacted most on procedural error reduction in both studies (32- 42%). The correlation observed between the VR and real-world task performance was r > 0·96 (Study 2). CONCLUSIONS:: VR simulation training offers a powerful and effective platform for training safer skills.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim - To evaluate the reproducibility of the background fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Methods - 10 normal volunteers and 10 patients with retinal disease were included in the study. One eye per subject was chosen randomly. Five images of the same eye of each individual were obtained, after pupillary dilatation, by two investigators using a confocal scanning laser ophthalmoscope. Background fundus autofluorescence was measured at 7 degrees temporal to the fovea in normal volunteers and between 7 and 15 degrees temporal to the fovea in patients. Within session reproducibility of the measurements obtained by each investigator and interobserver reproducibility were evaluated. Results - For investigator 1 the median values of fundus autofluorescence obtained were 31.9 units for normal volunteers and 27.3 units for patients. The median largest difference in readings in normal volunteers was 5.7 units (range 1.4-13.5 units) and in patients 4.2 units (1.5-15.1 units). For investigator 2 the median values of fundus autofluorescence obtained were 28.9 units for normal volunteers and 27.4 units for patients. The median largest difference in readings in normal volunteers was 3.6 units (2.7-11.7 units), and in patients 4.1 units (1.5-9.3 units). The median interobserver difference in readings in normal volunteers was 3.3 units and for patients 6.6 units. The median greatest interobserver difference in measurements obtained for normal volunteers was 8.8 units (8.4-23.0 units) and for patients 11.1 units (7.1-40.8 units). Conclusion - Within session reproducibility of the measurements of background fundus autofluorescence was satisfactory. Although interobserver reproducibility was moderate, the variability of the measurements of fundus autofluorescence between observers appears to be small when compared with variation in fundus autofluorescence with age and disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aetiology of primary brain tumours is largely unknown; the role of non-steroidal anti-inflammatory drugs (NSAIDs) or aspirin use and glioma risk has been inconclusive, but few population-based studies with reliable prescribing data have been conducted, and the association with meningioma risk has yet to be assessed. Methods: The UK Clinical Practice Research Datalink was used to assess the association between aspirin and non-aspirin NSAID use and primary brain tumour risk using a nested case-control study design. Conditional logistic regression analysis was performed on 5,052 brain tumour patients aged 16 years and over, diagnosed between 1987 and 2009 and 42,678 controls matched on year of birth, gender and general practice, adjusting for history of allergy and hormone replacement therapy use in the glioma and meningioma models, respectively.

Results: In conditional logistic regression analysis, excluding drug use in the year preceding the index date, there was no association with non-aspirin NSAID use (OR 0.96, 95 % CI 0.81-1.13) or glioma risk comparing the highest category of daily defined dose to non-users; however, non-aspirin NSAID use was positively associated with meningioma risk (OR 1.35, 95 % CI 1.06-1.71). No association was seen with high- or low-dose aspirin use irrespective of histology.

Conclusions: This large nested case-control study finds no association between aspirin or non-aspirin NSAID use and risk of glioma but a slight increased risk with non-aspirin NSAIDs and meningioma. © 2013 Springer Science+Business Media Dordrecht.