998 resultados para Ruth Cardoso
Resumo:
This paper presents the development of a prototype of a tubular linear induction motor applied to onshore oil exploitation, named MAT AE OS (which is the Portuguese acronym for Tubular Asynchronous Motor for Onshore Oil Exploitation). The function of this motor is to directly drive the sucker-rod pump installed in the down hole of the oil well. Considering the drawbacks and operational costs of the conventional oil extraction method, which is based on the walking beam and rod, string system, the developed prototype is intended to become a feasible alternative from both technical and economic points of view. At the present time, the MAT AE OS prototype is installed in a test bench at the Applied Electromagnetism Laboratory at the Escola Politecnica da Universidade de Sao Paulo. The complete testing system is controlled and supervised by special software, enabling good flexibility in operation, data acquisition, and performance analysis. The test results indicate that the motor develops a constant lift force along the pumping cycle, as shown by the measured dynamometric charts. Also, the evaluated electromechanical performance seems to be superior to that obtained by the traditional method. The system utilizing the MAT AE OS prototype allows the complete elimination of the rod string sets required by the conventional equipment, indicating that the new system may advantageously replace the surface mechanical components presently utilized.
Resumo:
An improvement to the quality bidimensional Delaunay mesh generation algorithm, which combines the mesh refinement algorithms strategy of Ruppert and Shewchuk is proposed in this research. The developed technique uses diametral lenses criterion, introduced by L. P. Chew, with the purpose of eliminating the extremely obtuse triangles in the boundary mesh. This method splits the boundary segment and obtains an initial prerefinement, and thus reducing the number of necessary iterations to generate a high quality sequential triangulation. Moreover, it decreases the intensity of the communication and synchronization between subdomains in parallel mesh refinement.
Resumo:
A geometrical approach of the finite-element analysis applied to electrostatic fields is presented. This approach is particularly well adapted to teaching Finite Elements in Electrical Engineering courses at undergraduate level. The procedure leads to the same system of algebraic equations as that derived by classical approaches, such as variational principle or weighted residuals for nodal elements with plane symmetry. It is shown that the extension of the original procedure to three dimensions is straightforward, provided the domain be meshed in first-order tetrahedral elements. The element matrices are derived by applying Maxwell`s equations in integral form to suitably chosen surfaces in the finite-element mesh.
Resumo:
One of the most important recent improvements in cardiology is the use of ventricular assist devices (VADs) to help patients with severe heart diseases, especially when they are indicated to heart transplantation. The Institute Dante Pazzanese of Cardiology has been developing an implantable centrifugal blood pump that will be able to help a sick human heart to keep blood flow and pressure at physiological levels. This device will be used as a totally or partially implantable VAD. Therefore, an improvement on device performance is important for the betterment of the level of interaction with patient`s behavior or conditions. But some failures may occur if the device`s pumping control does not follow the changes in patient`s behavior or conditions. The VAD control system must consider tolerance to faults and have a dynamic adaptation according to patient`s cardiovascular system changes, and also must attend to changes in patient conditions, behavior, or comportments. This work proposes an application of the mechatronic approach to this class of devices based on advanced techniques for control, instrumentation, and automation to define a method for developing a hierarchical supervisory control system that is able to perform VAD control dynamically, automatically, and securely. For this methodology, we used concepts based on Bayesian network for patients` diagnoses, Petri nets to generate a VAD control algorithm, and Safety Instrumented Systems to ensure VAD system security. Applying these concepts, a VAD control system is being built for method effectiveness confirmation.
Resumo:
A procedure is proposed to accurately model thin wires in lossy media by finite element analysis. It is based on the determination of a suitable element width in the vicinity of the wire, which strongly depends on the wire radius to yield accurate results. The approach is well adapted to the analysis of grounding systems. The numerical results of the application of finite element analysis with the suitably chosen element width are compared with both analytical results and those computed by a commercial package for the analysis of grounding systems, showing very good agreement.
Resumo:
The following papers constitute a selection among the best papers presented at the Ninth IEEE/IAS International Conference on Industry Applications (INDUSCON) held in Sao Paulo from 8(th) to 10(th) of November, 2010. This event gathered a significant number of people from academia and industry interested in applications of Electrical and Electronic engineering to industry.
Resumo:
The evaporators of sugar plants in Brazil have used carbon steel intensively because of it is, a low priced material, which possesses inferior corrosion resistance. The materials more indicated for the substitution of carbon steel are stainless steels, however they are considered expensive. The environmental and financial performances of evaporator pipes constructed with carbon steel and with types AISI 304 444 and 439 stainless steel were evaluated. For the environmental evaluation, the Life Cycle Assessment (LCA) methodology Was used and it, revealed that stainless steel is more environmentally efficient than carbon steel. The life cycle costing (LCC) technique was the tool chosen for the financial evaluation and it showed that stainless steel is a better investment option compared to carbon steel. The results also indicate that LCA and LCC methodologies must be used together Therefore, it can he seen that safer environmental products can come to be the most profitable investment options.
Resumo:
Demands for optimal boiler performance and increased concerns in lowering emission have always been the driving force in the reevaluation and evolution of the Kraft boiler: specifically the air distribution strategies that are directly related to achieving increased residence time of flue gas combustion inside the furnace which in turn lowers atmosphere emission levels and enhances boiler operation. This paper presents the results of a study that analyzes the interaction of the different multilevel air injections have on flue gas flow patterns including various quaternary air supply arrangements. Additionally, this study assesses the performance of the CFD (Computational Fluid Dynamics) model against data available in literature. Simulations were performed considering isothermal and incompressible flows, and did not take into account thermal phenomena or chemical reactions. The numerical solutions generated proved to be coherently related to the data available in literature, and provided proof of the efficiency of tertiary level air injection, as well as revealed that quaternary air injection ports arranged in a symmetrical configuration is most suitable for optimal equipment operation. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Intravascular ultrasound (IVUS) image segmentation can provide more detailed vessel and plaque information, resulting in better diagnostics, evaluation and therapy planning. A novel automatic segmentation proposal is described herein; the method relies on a binary morphological object reconstruction to segment the coronary wall in IVUS images. First, a preprocessing followed by a feature extraction block are performed, allowing for the desired information to be extracted. Afterward, binary versions of the desired objects are reconstructed, and their contours are extracted to segment the image. The effectiveness is demonstrated by segmenting 1300 images, in which the outcomes had a strong correlation to their corresponding gold standard. Moreover, the results were also corroborated statistically by having as high as 92.72% and 91.9% of true positive area fraction for the lumen and media adventitia border, respectively. In addition, this approach can be adapted easily and applied to other related modalities, such as intravascular optical coherence tomography and intravascular magnetic resonance imaging. (E-mail: matheuscardosomg@hotmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in which the active control is executed in only one degree of freedom, in the axial direction of the rotor. Remaining degrees of freedom, excepting the rotation, are restricted only by the attraction force between pairs of permanent magnets. This study is part of a joint project in development by IDPC and Escola Politecnica of Sao Paulo University, Brazil. This article shows advances in that project, presenting two promising solutions for magnetic bearings. One solution uses hybrid cores as electromagnetic actuators, that is, cores that combine iron and permanent magnets. The other solution uses actuators, also of hybrid type, but with the magnetic circuit closed by an iron core. After preliminary analysis, a pump prototype has been developed for each solution and has been tested. For each prototype, a brushless DC motor has been developed as the rotor driver. Each solution was evaluated by in vitro experiments and guidelines are extracted for future improvements. Tests have shown good results and demonstrated that one solution is not isolated from the other. One complements the other for the development of a single-axis-controlled, hybrid-type magnetic bearing for a mixed-flow type VAD.
Resumo:
The design, construction, and characterization of a portable opto-coupled potentiostat are presented. The potentiostat is battery-powered, managed by a microcontroller, which implements cyclic voltammetry (CV) using suitable sensor electrodes. Its opto-coupling permits a wide range of current measurements, varying from mA to nA. Two software interfaces were developed to perform the CV measurement: a virtual instrument for a personal computer (PC) and a C-base interface for personal digital assistant (PDA). The potentiostat has been evaluated by detection of potassium ferrocyanide in KCl medium, both with macro and microelectrodes. There was good agreement between the instrumental results and those from commercial equipment.
Resumo:
BACKGROUND: Guidelines for red blood cell (RBC) transfusions exist; however, transfusion practices vary among centers. This study aimed to analyze transfusion practices and the impact of patients and institutional characteristics on the indications of RBC transfusions in preterm infants. STUDY DESIGN AND METHODS: RBC transfusion practices were investigated in a multicenter prospective cohort of preterm infants with a birth weight of less than 1500 g born at eight public university neonatal intensive care units of the Brazilian Network on Neonatal Research. Variables associated with any RBC transfusions were analyzed by logistic regression analysis. RESULTS: Of 952 very-low-birth-weight infants, 532 (55.9%) received at least one RBC transfusion. The percentages of transfused neonates were 48.9, 54.5, 56.0, 61.2, 56.3, 47.8, 75.4, and 44.7%, respectively, for Centers 1 through 8. The number of transfusions during the first 28 days of life was higher in Center 4 and 7 than in other centers. After 28 days, the number of transfusions decreased, except for Center 7. Multivariate logistic regression analysis showed higher likelihood of transfusion in infants with late onset sepsis (odds ratio [OR], 2.8; 95% confidence interval [CI], 1.8-4.4), intraventricular hemorrhage (OR, 9.4; 95% CI, 3.3-26.8), intubation at birth (OR, 1.7; 95% CI, 1.0-2.8), need for umbilical catheter (OR, 2.4; 95% CI, 1.3-4.4), days on mechanical ventilation (OR, 1.1; 95% CI, 1.0-1.2), oxygen therapy (OR, 1.1; 95% CI, 1.0-1.1), parenteral nutrition (OR, 1.1; 95% CI, 1.0-1.1), and birth center (p < 0.001). CONCLUSIONS: The need of RBC transfusions in very-low-birth-weight preterm infants was associated with clinical conditions and birth center. The distribution of the number of transfusions during hospital stay may be used as a measure of neonatal care quality.
Resumo:
This paper focuses on the characterization of carbide lime (CL) - a by-product of acetylene production, composed mainly of calcium hydroxide with minor parts of carbonate - and compares its features to those of ""dry"" hydrated lime (HL) commonly used as a building material. Chemical, thermogravimetric and X-ray diffraction analyses indicated that the limes are similar in chemical and mineralogical compositions. except for the presence of carbon in the waste. Morphological and elemental chemical analyses by SEM and EDS revealed that CL particles differ from HL ones in their morphology and by the presence of carbon formations, Physical characterization included density and BET surface area of the materials. as well as, their particle size distributions in deionized water at diverse time periods. CL underwent agglomeration after approximately 60 min in water, whereas HL progressively became finer with time as determined by laser diffraction. In addition, water retention and squeeze flow tests were used to assess the pastes` fresh properties. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a rheological investigation of pure gypsum (PG) and a commercial gypsum-lime-filler plaster (CP) using the modified Vicat apparatus and squeeze flow method. The samples were tested at several different intervals after manual or mechanical mixing. The results confirmed squeeze flow to be more sensitive in determining fresh paste behavior than the modified Vicat apparatus. PG set faster when prepared in mechanical mixer than when manually mixed. Conversely, the CP composition presented longer setting when mixed mechanically. The study also included the analysis of two ready-to-use polymer-based products for leveling and rendering (drywall joint compound - DJC; acrylic putty - AP) measured by squeeze flow and compared to the commercial composition. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this work was evaluate the effect of citric acid at 1% and 2% in the maintenance of the quality of minimally processed `Regis` peaches, during 9 days storage under refrigeration (5+/-1 degrees C, 85-87% RU) and passive modified atmospheres. The following analyses were realized: color, firmness, texture, soluble solids, titratable acidity, pH, CO(2) and O(2). Increasing in a value and decreasing in b and L values on minimally processed peaches were observed, independent of the citric acid treatment, indicating a browning on the product mainly on the 9(th) day of storage. Overall, the levels of titratable acidity and pH changed at the storage period and at the concentrations studied, unlike the content of soluble solids that remained unchanged. The texture, CO(2) and O(2) changed only for the storage period unlike texture that was higher with the treatment of citric acid 2%. It can be concluded that neither tested concentration of citric acid was effective in preventing enzymatic browning of minimally processed peaches stored the 5+/-1 degrees C and 85-87% RU and passive modified atmosphere.