986 resultados para Pressure range


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Previous research suggested that proper blood pressure (BP) management in acute stroke may need to take into account the underlying etiology. METHODS: All patients with acute ischemic stroke registered in the ASTRAL registry between 2003 and 2009 were analyzed. Unfavorable outcome was defined as modified Rankin Scale score >2. A local polynomial surface algorithm was used to assess the effect of baseline and 24- to 48-hour systolic BP (SBP) and mean arterial pressure (MAP) on outcome in patients with lacunar, atherosclerotic, and cardioembolic stroke. RESULTS: A total of 791 patients were included in the analysis. For lacunar and atherosclerotic strokes, there was no difference in the predicted probability of unfavorable outcome between patients with an admission BP of <140 mm Hg, 140-160 mm Hg, or >160 mm Hg (15.3 vs 12.1% vs 20.8%, respectively, for lacunar, p = 015; 41.0% vs 41.5% vs 45.5%, respectively, for atherosclerotic, p = 075), or between patients with BP increase vs decrease at 24-48 hours (18.7% vs 18.0%, respectively, for lacunar, p = 0.84; 43.4% vs 43.6%, respectively, for atherosclerotic, p = 0.88). For cardioembolic strokes, increase of BP at 24-48 hours was associated with higher probability of unfavorable outcome compared to BP reduction (53.4% vs 42.2%, respectively, p = 0.037). Also, the predicted probability of unfavorable outcome was significantly different between patients with an admission BP of <140 mm Hg, 140-160 mm Hg, and >160 mm Hg (34.8% vs 42.3% vs 52.4%, respectively, p < 0.01). CONCLUSIONS: This study provides evidence to support that BP management in acute stroke may have to be tailored with respect to the underlying etiopathogenetic mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We characterize divergence times, intraspecific diversity and distributions for recently recognized lineages within the Hyla arborea species group, based on mitochondrial and nuclear sequences from 160 localities spanning its whole distribution. Lineages of H. arborea, H. orientalis, H. molleri have at least Pliocene age, supporting species level divergence. The genetically uniform Iberian H. molleri, although largely isolated by the Pyrenees, is parapatric to H. arborea, with evidence for successful hybridization in a small Aquitanian corridor (southwestern France), where the distribution also overlaps with H. meridionalis. The genetically uniform H. arborea, spread from Crete to Brittany, exhibits molecular signatures of a postglacial range expansion. It meets different mtDNA clades of H. orientalis in NE-Greece, along the Carpathians, and in Poland along the Vistula River (there including hybridization). The East-European H. orientalis is strongly structured genetically. Five geographic mitochondrial clades are recognized, with a molecular signature of postglacial range expansions for the clade that reached the most northern latitudes. Hybridization with H. savignyi is suggested in southwestern Turkey. Thus, cryptic diversity in these Pliocene Hyla lineages covers three extremes: a genetically poor, quasi-Iberian endemic (H. molleri), a more uniform species distributed from the Balkans to Western Europe (H. arborea), and a well-structured Asia Minor-Eastern European species (H. orientalis).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Recent reviews of randomized control trials have shown that pharmacist interventions improve cardiovascular diseases (CVD) risk factors in outpatients. Various interventions were evaluated in different settings, and a substantial heterogeneity was observed in the effect estimates. To better express uncertainties in the effect estimates, prediction intervals (PI) have been proposed but are, however, rarely reported. Objective: Pooling data from two systematic reviews, we estimated the effect of pharmacist interventions on systolic blood pressure (BP), computed PI, and evaluated potential causes of heterogeneity. Methods: Data were pooled from systematic reviews assessing the effect of pharmacist interventions on CVD risk factors in patients with or without diabetes, respectively. Effects were estimated using random effect models. Results: Systolic BP was the outcome in 31 trials including 12 373 patients. Pharmacist interventions included patient educational interventions, patient-reminder systems, measurement of BP, medication management and feedback to physician, or educational intervention to health care professionals. Pharmacist interventions were associated with a large reduction in systolic BP (-7.5 mmHg; 95% CI: -9.0 to -5.9). There was a substantial heterogeneity (I2: 66%). The 95% PI ranged from -13.9 to -1.0 mmHg. The effect tended to be larger if the intervention was conducted in a community pharmacy and if the pharmacist intervened at least monthly. Conclusion: On average, the effect of pharmacist interventions on BP was substantial. However, the wide PI suggests that the effect differed between interventions, with some having modest effects and others very large effects on BP. Part of the heterogeneity could be due to differences in the setting and in the frequency of the interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The distribution limits of Crocidura russula (Hermann, 1780) and C. leucodon (Hermann, 1780) were investigated during an interval of 25 years in the bottom of the Rhone valley above Lake Geneva, Switzerland (total data set: 105 spatio-temporal occurrences, 1137 shrews). In 1975, the contact zone between the two species was situated in the region of Martigny. In 1999/2000, new sampling revealed three results: (1) The contact zone showed an upward shift of about 25 km. (2) In the expanded range of C. russula, the resident species has totally disappeared (confirmed by owl pellets analysis). (3) This demonstrates a dominance of C, russula over C. leucodon. Three hypotheses which may explain the range expansion of C. russula were evaluated: (1) habitat modification favouring linear dispersal due to the construction of a highway; (2) temporal event favoured by climate fluctuations, or (3) ongoing postglacial colonisation of Europe. Hypothesis 1 was rejected, because the progression of the shrews anticipated the construction. Hypothesis 3 received only weak support because range limits of C. russula in the region of Nice have been stable for thousands of years. Therefore hypothesis 2, admitting that ongoing climate change has facilitated range expansion, is the most probable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMEDurant la phase de récupération d'un exercice de course à pied d'intensité maximale ou submaximale, une augmentation de la pression artérielle systolique centrale (aortique) résultant de la réflexion des ondes de pouls sur l'arbre vasculaire est constatée chez l'individu en bonne santé. En diastole cependant, l'impact de la réflexion de ces ondes de pouls sur la pression centrale demeure inconnu durant la récupération d'un exercice.Nous avons évalué les ondes de pouls centrales systolique et diastolique chez onze athlètes d'endurance durant la phase de récupération d'un exercice de course à pied dans des conditions d'effort maximal (sur tapis de course) et lors d'un effort submaximal lors d'une course à pied de 4000 mètres en plein air sur terrain mixte.Pour chaque sujet et lors des deux exercices, l'onde de pouls a été mesurée au niveau radial par tonométrie d'aplanation durant une phase de repos précédant l'exercice, puis à 5, 15, 25, 35 et 45 minutes après la fin de l'exercice. En utilisant une fonction mathématique de transfert, l'onde de pouls centrale a été extrapolée à partir de l'onde de pouls radiale. En compilant la forme de l'onde de pouls centrale avec une mesure simultanée de la pression artérielle brachiale, un index d'augmentation de l'onde de pouls en systole (Alx) et en diastole (Als) peut être calculé, reflétant l'augmentation des pressions résultant de la réflexion des ondes sur l'arbre vasculaire périphérique.A 5 minutes de la fin de l'exercice, les deux index ont été mesurés moindres que ceux mesurés lors de la phase précédant celui-ci. Lors des mesures suivantes, Alx est resté bas, alors que Aid a progressivement augmenté pour finalement dépasser la valeur de repos après 45 minutes de récupération. Le même phénomène a été constaté pour les deux modalités d'exercice (maximal ou submaximal). Ainsi, au-delà de quelques minutes de récupération après un exercice de course d'intensité maximale ou submaximale, nous avons montré par ces investigations que les ondes de pouls réfléchies en périphérie augmentent de façon sélective la pression centrale en diastole chez l'athlète d'endurance.ABSTRACTDuring recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 minutes after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (Alx) and a diastolic index (Aid) of pressure augmentation by reflections. At 5 minutes, both indices were below preexercise. At further time-points, Alx remained low, while Aid progressively increased, to overshoot above preexercise at 45 minutes. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance- trained athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Located at the internal border of the Grand-Saint-Bernard Zone, the diorite and its aureole lie on top of intensively studied Alpine eclogitic units but this pluton, poorly studied yet, has kept locally almost undeformed. The pluton intruded, at similar to 360 Ma, country-rocks mostly composed of dark shales with Na2O > K2O and minor mafic intercalations of tholeiitic basalt affinity. This association is characteristic of the Vanoise (France) basement series, where available age determinations suggest an Early Paleozoic age. Parts of the pluton, and of its hornfels aureole that is evidenced here for the first time, in the Punta Bioula section of Valsavaranche valley (NW-Italy), have been well-preserved from the Alpine deformation. Syn-emplacement hardening, dehydration-induced, probably prevented strain-enhanced Alpine recrystallization. Magmatic rock-types range continuously from subordinate mafic types at SiO2 similar to 48%, of hornblendite with cumulative or appinite affinities, to the main body of quartz diorite to quartz monzonite (SiO2 up to 62%). P-T estimates for the pluton emplacement, based on the abundance of garnet in the hornfelses, using also zircon and apatite saturation thermometry and Al-in-hornblende barometry, suggest T similar to 800-950 degrees C and minimum P in the 0.2-0.5 GPa range, with records of higher pressure conditions (up to 1-2 GPa?) in hornblendite phlogopite-cored amphibole. The high-K, Na > K, calcalkaline geochemistry is in line with a destructive plate-margin setting. Based on major element data and radiogenic isotope signature (epsilon Nd-360 Ma from -1.2 to + 0.9, Sr-87/Sr-86(360 MA) from 0.7054 to 0.7063), the parental magmas are interpreted in terms of deep-seated metabasaltic partial melts with limited contamination from shallower sources, the low radiogenic Nd-content excluding a major contribution from Vanoise tholeiites. There is no other preserved evidence for Variscan magmatism of similar age and composition in the Western Alps, but probable analogs are known in the western and northern parts of French Massif Central. Regarding the Alpine tectonics, not only the age of the pluton and its host-rocks (instead of the Permo-Carboniferous age previously believed), but also its upper mylonitic contact, suggest revisions of the Alpine nappe model. The Cogne diorite allegedly constituted the axial part of the E-verging ``pli en retour [backfold] du Valsavaranche'', a cornerstone of popular Alpine structural models: in fact, the alleged fold limbs, as attested here by field and geochemical data, do not belong to the same unit, and the backfold hypothesis is unfounded. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the relationship between blood pressure (BP) levels and physical activity (PA) domains accounting for overweight/obesity. Adolescents aged 10 to 17 years old were recruited (n = 1021). International Obesity Task Force (IOTF) criteria were used to define overweight and obesity. High BP was defined using the Center of Disease Control and Prevention criteria. Different domains of PA (school activities, sport out of school, and leisure time PA) were assessed using a validated questionnaire. The prevalence of overweight/obesity was 21.9% for boys and 14.8% for girls. Some 13.4% of boys and 10.2% of girls, respectively, had high blood pressure (HBP). A strong and positive association was found between overweight and HBP. After adjustment for body mass index (BMI), total PA was inversely associated with BP. When all PA domains were entered simultaneously in a regression model, and after adjustment for BMI, only sport out of school was significantly and inversely associated with systolic BP [β: -0.82 (-1.50; -0.13)]. These findings open avenue for the early prevention of HBP by the prevention of obesity and promotion of PA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Control of blood pressure (BP) remains a major challenge in primary care. Innovative interventions to improve BP control are therefore needed. By updating and combining data from 2 previous systematic reviews, we assess the effect of pharmacist interventions on BP and identify potential determinants of heterogeneity. METHODS AND RESULTS: Randomized controlled trials (RCTs) assessing the effect of pharmacist interventions on BP among outpatients with or without diabetes were identified from MEDLINE, EMBASE, CINAHL, and CENTRAL databases. Weighted mean differences in BP were estimated using random effect models. Prediction intervals (PI) were computed to better express uncertainties in the effect estimates. Thirty-nine RCTs were included with 14 224 patients. Pharmacist interventions mainly included patient education, feedback to physician, and medication management. Compared with usual care, pharmacist interventions showed greater reduction in systolic BP (-7.6 mm Hg, 95% CI: -9.0 to -6.3; I(2)=67%) and diastolic BP (-3.9 mm Hg, 95% CI: -5.1 to -2.8; I(2)=83%). The 95% PI ranged from -13.9 to -1.4 mm Hg for systolic BP and from -9.9 to +2.0 mm Hg for diastolic BP. The effect tended to be larger if the intervention was led by the pharmacist and was done at least monthly. CONCLUSIONS: Pharmacist interventions - alone or in collaboration with other healthcare professionals - improved BP management. Nevertheless, pharmacist interventions had differential effects on BP, from very large to modest or no effect; and determinants of heterogeneity could not be identified. Determining the most efficient, cost-effective, and least time-consuming intervention should be addressed with further research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood pressures measured casually by a doctor often differ considerably from those recorded during everyday activities away from the medical environment. In the present study, we compared office and ambulatory recorded pressures in 475 consecutive untreated patients diagnosed hypertensive by physicians. Blood pressure monitored non-invasively during the day was, on average 15/7 mmHg lower than the corresponding office pressures. The difference between office and ambulatory recorded pressure tended to be greatest in those patients with the highest office blood pressure levels, although the relationship between the two types of measurement was too weak (r = 0.50 and 0.38 for systolic and diastolic pressure, respectively) to have any predictive value in the individual patient. Office blood pressures were at least 10 mmHg higher than ambulatory pressures in 62% of patients for systolic and 42% for diastolic pressure. Blood pressure levels recorded during ambulatory monitoring were higher than in the doctor's office for 18% of patients for systolic and 22% for diastolic pressure. Among patients with systolic pressures of between 161 and 180 mmHg or diastolic pressures between 96 and 105 mmHg when facing a doctor, 27 and 37% respectively, showed markedly lower systolic (less than 140 mmHg) or diastolic (less than 90 mmHg) ambulatory recorded pressures. These data therefore indicate that ambulatory blood pressure monitoring may help to identify those truly hypertensive patients who are most likely to benefit from antihypertensive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iowa Code Section 216A.135 requires the Criminal and Juvenile Justice Planning Advisory Council (CJJPAC) to submit a long-range plan for Iowa's justice system to the Governor and General Assembly every five years. The first plan developed after the creation of the Division of Criminal and Juvenile Justice Planning was issued in 1990 and annually updated through 1994. Since 1992, appropriation law has required the CJJPAC to coordinate their planning activities with those of the Iowa Juvenile Justice Advisory Council (JJAC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.