990 resultados para Passive Air Sampling
Resumo:
The sea surface microlayer (SML), although poorly understood, is important in biogeochemical cycling and sea - air exchanges; it is a source or a sink for a range of pollutants. In this paper, an overview of sampling techniques and the role of SML in biogeochemical cycles and climate is presented. The chemical and biological nature of the ocean surface film and its interaction with atmospheric aerosols are discussed. Special attention is given to organic constituents, gel-like compounds, surfactants, halogenated compounds, and metals. Estimates of air - sea exchange fluxes-with focus on organic carbon, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls-are compiled. In addition, research gaps in the chemical composition of marine aerosols and their relationship with SML are described.
Resumo:
Oopperasta Faust.
Resumo:
Teollisuuden jäähdytysjärjestelmiä tarvitaan prosessien lämpötilan ja paineen hal-litsemiseen. Vesi on käytetyin lämmönsiirtoaine hyvän saatavuutensa, halvan hin-nan ja korkean lämmönsiirtokyvyn ansiosta. Jäähdytysjärjestelmät jaetaan kolmeen päätyyppiin, joita ovat läpivirtausjäähdytys, suljettu ja avoin kiertojäähdytys. Kullakin järjestelmätyypillä on tyypilliset alatyyppinsä. Avoimella kiertojär-jestelmällä on eniten alatyyppejä, joista yleisin on jäähdytystorni. Jäähdytystorneja on kolmea tyyppiä: märkä-, kuiva ja hybriditorni. Kullakin järjestelmätyypillä on ominaiset piirteensä käyttökohteiden, ympäristövaikutusten, ohjattavuuden, investointi- ja käyttökulujen suhteen, joita tässä työssä esitellään. Työssä tutkitaan teollisuuden jäähdytysjärjestelmien esittelyn lisäksi erään ali-painekaasunpoistimen soveltuvuutta suljetun kiertojäähdytysjärjestelmän kaasun-poistoon. Suljettuun kiertojäähdytysjärjestelmään jää ilmaa täyttövaiheessa ja kul-keutuu liuenneena käytettävän jäähdytysveden mukana. Muodostuva ylikylläinen seos synnyttää veden sekaan ilmakuplia, jotka aiheuttavat korroosiota kemiallisesti ja kuluttamalla. Lisäksi kaasukuplat vievät tilavuutta nesteeltä. Tämä pienentää järjestelmän jäähdytystehoa merkittävästi, koska kaasun lämmönsiirtokyky verrat-tuna veden lämmönsiirtokykyyn on pieni. Työssä esitellään myös muita mahdolli-sia suljetun järjestelmän kaasulähteitä ja niiden aiheuttamia ongelmia. Alipainekaasunpoistimen kaasunerotustehokkuutta mitattiin jäähdytysvesinäyttei-den selkeytymisnopeudella ja lämmönsiirtimien tehon paranemisella. Kahden viikon tarkastelujaksolla selkeytymisajat paranivat 36–60 % eri mittauspaikoissa ja lämmönsiirtimien tehot paranivat 6–29 %. Järjestelmään kuitenkin jäi merkittävä määrä kaasua, vaikka laitteen käyttöä jatkettiin tarkastelujakson jälkeen, joten tavoitteisiin ei päästy. Tutkitun alipainekaasunpoistolaitteen ei todettu soveltuvan tehdasympäristöön kestämättömyyden, hankalakäyttöisyyden ja tehottomuuden takia. Tulokset kuitenkin osoittavat, että kaasunerotuksella on merkittävä vaikutus suljetun jäähdytysjärjestelmän toimivuuteen ja saavutettavaan jäähdytystehoon.
Resumo:
This study was carried to evaluate the efficiency of the Bitterlich method in growth and yield modeling of the even-aged Eucalyptus stands. 25 plots were setup in Eucalyptus grandis cropped under a high bole system in the Central Western Region of Minas Gerais, Brazil. The sampling points were setup in the center of each plot. The data of four annual mesurements were colleted and used to adjust the three model types using the age, the site index and the basal area as independent variables. The growths models were fitted for volume and mass of trees. The efficiency of the Bitterlich method was confirmed for generating the data for growth and yield modeling.
Resumo:
In order to verify Point-Centered Quarter Method (PCQM) accuracy and efficiency, using different numbers of individuals by per sampled area, in 28 quarter points in an Araucaria forest, southern Paraná, Brazil. Three variations of the PCQM were used for comparison associated to the number of sampled individual trees: standard PCQM (SD-PCQM), with four sampled individuals by point (one in each quarter), second measured (VAR1-PCQM), with eight sampled individuals by point (two in each quarter), and third measuring (VAR2-PCQM), with 16 sampled individuals by points (four in each quarter). Thirty-one species of trees were recorded by the SD-PCQM method, 48 by VAR1-PCQM and 60 by VAR2-PCQM. The level of exhaustiveness of the vegetation census and diversity index showed an increasing number of individuals considered by quadrant, indicating that VAR2-PCQM was the most accurate and efficient method when compared with VAR1-PCQM and SD-PCQM.
Resumo:
ABSTRACTWhile a number of papers have shown that subway systems have an impact on the air quality through the release of particulate matters, no information about the impact of such particles on tree attributes is available. Tree leaves from three different species from the exit side of a subway station in Rio de Janeiro, Brazil, were more asymmetrical than leaves from the entrance side. This leaves also presenting changes in leaves cuticle and chlorophyll content.
Resumo:
This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.
Resumo:
In the forced-air cooling process of fruits occurs, besides the convective heat transfer, the mass transfer by evaporation. The energy need in the evaporation is taken from fruit that has its temperature lowered. In this study it has been proposed the use of empirical correlations for calculating the convective heat transfer coefficient as a function of surface temperature of the strawberry during the cooling process. The aim of this variation of the convective coefficient is to compensate the effect of evaporation in the heat transfer process. Linear and exponential correlations are tested, both with two adjustable parameters. The simulations are performed using experimental conditions reported in the literature for the cooling of strawberries. The results confirm the suitability of the proposed methodology.
Resumo:
Taking into account that the sampling intensity of soil attributes is a determining factor for applying of concepts of precision agriculture, this study aims to determine the spatial distribution pattern of soil attributes and corn yield at four soil sampling intensities and verify how sampling intensity affects cause-effect relationship between soil attributes and corn yield. A 100-referenced point sample grid was imposed on the experimental site. Thus, each sampling cell encompassed an area of 45 m² and was composed of five 10-m long crop rows, where referenced points were considered the center of the cell. Samples were taken from at 0 to 0.1 m and 0.1 to 0.2 m depths. Soil chemical attributes and clay content were evaluated. Sampling intensities were established by initial 100-point sampling, resulting data sets of 100; 75; 50 and 25 points. The data were submitted to descriptive statistical and geostatistics analyses. The best sampling intensity to know the spatial distribution pattern was dependent on the soil attribute being studied. The attributes P and K+ content showed higher spatial variability; while the clay content, Ca2+, Mg2+ and base saturation values (V) showed lesser spatial variability. The spatial distribution pattern of clay content and V at the 100-point sampling were the ones which best explained the spatial distribution pattern of corn yield.
Resumo:
To maintain a competitive development of the Brazilian aviculture, some measures must be taken to enable the identification and reduction of risks to the health of birds, as well as for the physical environment. Therefore, the aim of this study was to evaluate the effectiveness of three different systems of minimum ventilation (positive pressure - SVMP, negative pressure - SVMN and natural ventilation - SVMNat) in the air quality during the first 21 days of life of broiler chicks, during winter. Three points were selected along the length to verify ammonia, carbon monoxide and oxygen concentrations at 3a.m., 9a.m., 3p.m. and 9p.m., by the respiration level of birds and workers. The averages of pollutant gases did not exceed the tolerance levels for the three minimum ventilation systems evaluated, which is 20 and 10ppm for the birds level and 20 and 39ppm for the workers level, for ammonia and carbon monoxide, respectively. It was evident that the minimum ventilation systems were appropriately sized for the required minimum ambient air renovation, in respect to ventilation rates applied for the SVMN and SVMP systems, and with air velocity at levels that do not stress the chicks, including for the SVMNat. The three studied systems of minimum ventilation allowed the birds to externalize their productive performance, with values close to the ones considered satisfactory for all evaluated parameters, in accordance with the Brazilian aviculture standards.
Resumo:
The air dry-bulb temperature (t db),as well as the black globe humidity index (BGHI), exert great influence on the development of broiler chickens during their heating phase. Therefore, the aim of this study was to analyze the structure and the magnitude of the t db and BGHI spatial variability, using geostatistics tools such as semivariogram analysis and also producing kriging maps. The experiment was conducted in the west mesoregion of the states of Minas Gerais in 2010, in a commercial broiler house with heating system consisting of two furnaces that heat the air indirectly, in the firsts 14 days of the birds' life. The data were registered at intervals of five minutes in the period from 8 a.m. to 10 a.m. The variables were evaluated by variograms fitted by residual maximum likelihood (REML) testing the Spherical and Exponential models. Kriging maps were generated based on the best model used to fit the variogram. It was possible to characterize the variability of the t db and BGHI, which allowed observing the spatial dependence by using geostatistics techniques. In addition, the use of geostatistics and distribution maps made possible to identify problems in the heating system in regions inside the broiler house that may harm the development of chicks.
Resumo:
The air included in droplets generated by spray nozzles directly int0erferes in transport, deposition and retention of the droplets after its impact on the target. The objective of this study was to analyze the interference of adjuvants in the amount of air included in droplets generated by spray nozzles. The treatments were composed by four spray solutions containing mineral oil, vegetable oil, surfactant and water, and three spray nozzles, two air induction type and one pre-orifice. The air included was calculated by the difference between the volume of spray mix (air plus liquid) and only the liquid, which was made by means of sprayed samples captured in a funnel and collected in a graduated cylinder. The surface tension was estimated by the gravimetric method using a precision scale and a graduated pipette. The surfactant provided the largest percentage of air included in the spray. For the surface tension, the mineral oil and the surfactant had the lowest values. It was concluded that the use of adjuvants had a direct influence on the percentage of air included. In addition, products with greater ability to reduce surface tension and to form homogeneous solutions provided the increase in the percentage of air included in the droplet.
Resumo:
The air-assisted ground spray is fairly widespread. However, due to the unpredictable weather conditions, the operational efficiency is impaired by stops on grounds of low humidity and high temperatures. The aim of this work was to assess an air humidification method and evaluate its impact on temperature and air humidity for the air curtain of the air-assisted sprayer. With respect to relative air humidity, it has increased in 6.59%, being the maximum change when inserting 1.92 L min-1. So, it is concluded that the pipeline humidification might significantly reduce temperature and enhance air humidity. The treatments performed in this study consisted of a varied flow of a humidity device, related to weather conditions. Temperature and relative air humidity were measured at 1.0 m height from right to left of middle point of the machine, corresponding to the end of the spray boom, in the middle and end of right spray boom. The readings were also performed at three different distances from the end of the pipeline and at 0.25 and 0.50 m from that to the soil. The results show that 0.48 L min-1 in the humidification system has promoted a better efficiency in reducing air-temperature, on average 2.52 ºC when compared to the non-humidified one.