940 resultados para Parallel hot-wire method
Resumo:
A single and practical method to slain Malassezia furfur and Corynebacterium minutissimum in lesions' scales is described. The scales are collected by pressing small pieces of scotch tape (about 4 cm lenght and 2 cm width) onto the lesions and following withdrawl the furfuraceous scales will remain on the glue side. These pieces are then immersed for some minutes in lactophenol-cotton blue stain. Following absorption of the stain the scales are washed in current water to remove the excess of blue stain, dried with filter paper, dehydrated via passage in two bottles containing absolute alcohol and then placed in xylene in a centrifugation tube. The xylene dissolves the scotch tape glue and the scales fall free in the tube. After centrifugation and decantation the scales concentrated on the bottom of the tube are collected with a platinum-loop, placed in Canada balsam on a microscopy slide and closed with a cover slip. The preparations are then ready to be submitted to microscopic examination. Other stains may also be used instead of lactophenol-cotton blue. This method is simple, easily performed, and offers good conditions to study these fungi as well as being useful for the diagnosis of the diseases that they cause.
Resumo:
Sustainable Construction, Materials and Practice, p. 426-432
Resumo:
We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination
Resumo:
Dissertação de Mestrado apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Empreendedorismo e Internacionalização, sob orientação da Professora Doutora Maria Clara Ribeiro
Resumo:
As caldeiras são equipamentos de extrema importância na maioria das indústrias portuguesas. É prática frequente os projectos de caldeiras possuírem apenas cálculos de materiais ou estruturais, nunca abordando as questões térmicas das mesmas. Neste contexto surge o presente trabalho que teve como principal objectivo estudar e modelar o comportamento térmico de uma caldeira alimentada a biomassa florestal. A caldeira em estudo é uma caldeira tubos de fumo com ante-fornalha, alimentada a biomassa e com pressão de funcionamento de 10 bar. A primeira parte do trabalho consistiu no levantamento de toda a informação relativa aos aspectos construtivos da caldeira e as condições de operação da mesma, através da consulta do seu projecto. O estudo do comportamento térmico da caldeira foi dividido em 2 partes: a modelação do comportamento térmico na ante-fornalha seguido da modelação do comportamento térmico do feixe tubular. Na ante fornalha admitiu-se que o calor seria transferido do gás para as paredes da mesma por convecção e por radiação, tendo-se utilizado o Método de Hottel para modelar a transferência de calor por radiação. No feixe tubular a transferência de calor por radiação foi desprezada, tendo-se considerado apenas transferência de calor por condução e convecção entre os gases quentes e a água. Os resultados obtidos mostram que, na ante-fornalha, o peso da potência transferida por radiação (96%) é muito superior à potência transferida por convecção (4%), tendo-se obtido os valores de 384,8 kW e de 16,0 kW para a potência térmica transferida por radiação e por convecção, respectivamente. O valor obtido para a temperatura dos gases na ante-fornalha foi de 1085 K. No feixe tubular a potência térmica transferida por convecção foi de 2559 kW tendo-se obtido o valor de 240ºC para a temperatura de exaustão dos gases pela chaminé. As perdas para o exterior foram estimadas em 1,5 %. O balanço global de energia à caldeira indicou um peso para a potência transferida por convecção de 86,3% e para a potência transferida por radiação de 13,6%. O rendimento da caldeira foi calculado pelo método das perdas tendo-se obtido o valor de 39%.
Resumo:
For the purpose of research a large quantity of anti-measles IgG working reference serum was needed. A pool of sera from five teenagers was prepared and named Alexandre Herculano (AH). In order to calibrate the AH serum, 18 EIA assays were performed testing in parallel AH and the 2nd International Standard 1990, Anti-Measles Antibody, 66/202 (IS) in a range of dilutions (from 1/50 to 1/25600). A method which compared parallel lines resulting from the graphic representation of the results of laboratory tests was used to estimate the power of AH relative to IS. A computer programme written by one of the authors was used to analyze the data and make potency estimates. Another method of analysis was used, comparing logistic curves relating serum concentrations with optical density by EIA. For that purpose an existing computer programme (WRANL) was used. The potency of AH relative to IS, by either method, was estimated to be 2.4. As IS has 5000 milli international units (mIU) of anti-measles IgG per millilitre (ml), we concluded that AH has 12000 mIU/ml.
Resumo:
O desenvolvimento deste trabalho teve como principal objetivo obter uma primeira avaliação da nova proposta de revisão do Regulamento das Características do Comportamento Térmico de Edifícios (RCCTE), relativamente à certificação energética de edifícios existentes. Inicialmente foi feito um estudo da regulamentação térmica de edifícios em Portugal relativamente ao desempenho energético de edifícios. De seguida abordou-se o caso de estudo, onde para uma fração autónoma existente se compara a aplicação do RCCTE com a nova proposta de revisão. Este estudo comparativo foi realizado através de um método detalhado e um outro simplificado, que no caso do RCCTE está relacionado com a Nota Técnica NT-SCE-01 para a certificação térmica de edifícios existentes. Após obtidos os resultados das necessidades energéticas para todas as metodologias, referidas no parágrafo anterior, foi elaborada uma proposta de melhoria e a respetiva análise económica, de acordo com o Fundo de Eficiência Energética, FEE. As medidas de melhoria preconizadas, de acordo com este fundo, foram a substituição das janelas existentes por janelas eficientes e a utilização de coletores solares térmicos para preparação de água quente sanitária, AQS. Por fim, é feita uma análise dos resultados obtidos relativos às necessidades energéticas da fração autónoma, antes e após da proposta de melhoria.
Resumo:
A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
Resumo:
Euromicro Conference on Digital System Design (DSD 2015), Funchal, Portugal.
Resumo:
6th Real-Time Scheduling Open Problems Seminar (RTSOPS 2015), Lund, Sweden.
Resumo:
The local fractional Poisson equations in two independent variables that appear in mathematical physics involving the local fractional derivatives are investigated in this paper. The approximate solutions with the nondifferentiable functions are obtained by using the local fractional variational iteration method.