995 resultados para Ophthalmology.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To evaluate agreement between clinical examination (slit lamp examination and gonioscopy) and ultrasound biomicroscopy (UBM) in characterizing various features of the anterior chamber angle and adjacent structures. Methods. Twenty-eight patients (51 eyes) with open angle glaucoma (14), closed angle glaucoma (4), narrow angle and/or plateau iris (10), who had undergone UBM between March 94 and September 95 were studied. Evaluated parameters included angle width, iris configuration and presence of angle closure. The UBMs were reviewed in a masked fashion. Results. In 87.8% of cases there was agreement (within 10 degrees) between gonioscopic and UBM estimates of angle width. In all cases with greater than 10 degrees difference (12.2%) the angle size estimated by UBM was less than that estimated clinically. Iris configuration was graded identically in 51% of cases; the majority of disagreements (76.1%) occurred in cases graded as "regular" by gonioscopy and as "steep" by UBM. Angle closure was judged to be present more frequently by UBM. Conclusions. UBM and gonioscopy do not necessarily yield identical values for angle width, iris configuration, and presence of angle closure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims. To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas. Methods. 15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tono-Pen readings of IOP were obtained sequentially from the affected and non-affected corneal surface. Additionally, Goldmann applanation tonometry was attempted. Results. Determination of IOP with the Tono-Pen was possible in all cases, while Goldmann tonometry was not performed in three patients because of severe corneal irregularities. The average of the Tono-Pen readings obtained from the affected cornea (34.8 (SD 14.0) mmHg) was consistently and significantly higher (p <0.001) than mean IOP obtained by the Tono-Pen from the non-affected area (14.8 (4.3) mmHg). The average of Goldmann tonometry readings (14.4 (6.1) mmHg) did not differ significantly from the Tono-Pen values obtained from the non-affected corneal area (p = 0.47) but was significantly lower than the Tono-Pen measurements obtained from the affected area (p <0.001) Conclusion. In patients with band keratopathy or glued corneas determination of IOP by Tono-Pen tonometry varies from affected to non-affected area. The Tono-Pen overestimates the level of IOP when it is applied to areas with band keratopathy or with glue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background - The study of corneal endothelium, by specular microscopy, in patients with anterior uveitis has largely been restricted to observations on the endothelial cells. In this prospective study 'keratic precipitates' (KP) in different types of uveitis were examined in different stages of the disease process and the endothelial changes occurring in the vicinity of the KP were evaluated in comparison with the endothelium of the uninvolved eye. Methods - 13 patients with active unilateral uveitis were recruited. The mean age was 42.9 years (range 20-76 years). A Tomey-1100 contact wide field specular (x10) microscope was used to capture endothelial images and KP until the resolution of uveitis. Data regarding type of uveitis, number, size, and nature of KP were recorded. Automated morphometric analysis was done for cell size, cell density and coefficient of variation, and statistical comparisons of cell size and cell density were made (Student's t test) between the endothelium in the vicinity of fresh and resolving KP, fresh KP and normal endothelium, and resolving KP and normal endothelium. Results - On specular microscopy, fresh KP were seen as dense, white glistening deposits occupying 5-10 endothelial cells in diameter and fine KP were widely distributed and were one or two endothelial cells in diameter. The KP in Posner-Schlossman syndrome had a distinct and different morphology. With clinical remission of uveitis, the KP were observed to undergo characteristic morphological changes and old KP demonstrated a large, dark halo surrounding a central white deposit and occasionally a dark shadow or a 'lacuna' replaced the site of the original KP. Endothelial blebs were noted as dark shadows or defects in the endothelial mosaic in patients with recurrent uveitis. There was significant statistical difference in the mean cell size and cell density of endothelial cells in the vicinity of fresh KP compared with normal endothelium of the opposite eye. Conclusion - This study elucidated the different specular microscopic features of KP in anterior uveitis. Distinct morphological features of large and fine KP were noted. These features underwent dramatic changes on resolution of uveitis. The endothelium was abnormal in the vicinity of KP, which returned to near normal values on resolution of uveitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe the outcome of a series of Acanthamoeba keratitis treated with a similar regimen. Methods: All cases diagnosed with Acanthamoeba keratitis in a referral centre from June 1994 through June 1997 were included. Diagnosis of Acanthamoeba keratitis was based in clinical presentation and laboratory results. Positive laboratory identification of Acanthamoeba from corneal scraping or contact lens was required, unless the patient had very characteristic symptoms (severe pain) and signs of the infection, including perineural infiltrates. Initial intensive treatment included topical polyhexamethylene biguanide (PHMB) 0.02%, propamidine isothionate 0.1% and broad-spectrum antibiotics. The treatment was gradually tapered. After documented response to anti-acanthamoeba therapy, topical steroids were introduced; they were discontinued before cessation of the antiAcanthamoeba regimen. Results: Six males and four females, with a mean age of 30.0 ± 7.4 years were included in this study. All cases weared contact lenses. On presentation all cases had severe pain, and epitheliopathy was associated with stromal infiltrate in most (seven of ten) cases. Four patients had anterior uveitis. Perineural infiltrates were present in three cases and ring infiltrate in one patient. Anti-amoebic treatment was started 12.7 ± 7.2 days after beginning of symptoms. The clinical response to therapy was very satisfactory in all patients. Within two to three weeks all patients had remarkable lessening of pain and photophobia, and improvement of clinical signs. At two to three months, visual acuity had improved in all patients. Two patients required penetrating keratoplasty for visual rehabilitation. Conclusion: The use of PHMB and propamidine cured all cases of Acanthamoeba keratitis. Cautious introduction of steroids was associated with expedited resolution of inflammation and provided symptomatic relief.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glaucoma is one of the leading causes of blindness in the world. A wide range of therapeutic possibilities to control the disease and prevent glaucomatous optic nerve damage with subsequent loss of vision already exist. In a relatively high proportion of patients, medical and/or surgical therapies are contraindicated or become non-effective. The purpose of this article is to provide an overview on the latest achievements in the research of potential use of cannabinoids in glaucoma. Methods: The literature on recent basic science research on cannabinoids and a range of research studies using cannabinoids under different preparations and ways of application was reviewed. Conclusions: Cannabinoids effectively lower the intraocular pressure. Newer research findings allow a better understanding of the different possible mechanisms of action of cannabinoids on IOP. Future progress in different research fields concerning possible clinical applications of cannabinoids may offer better preparations with less or possibly no undesired side effects.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To evaluate differences in optic disc and visual field damage between African-American and Caucasian Normal Tension Glaucoma (NTG) patients. Methods. We retrospectively selected 33 African-American patients with the diagnosis of NTG and age-matched them with 33 Caucasian patients with the same diagnosis. Three masked observers graded disc photographs and visual fields as being normal, globally damaged or focally damaged for both eyes of the subject. Chi-square test was used to evaluate statistically significant differences between groups. Results. The results of the visual fields showed that in the African-American group, 24% were graded normal, 30% showed global damage, and 46% showed focal damage. This data was compared with the Caucasian group which showed 41% normal graded eyes, 22% with global damage, and 37% with focal damage (p = 0.28). The results of the optic disc photos showed that in the African-American group, 25% were graded normal, 45% showed global damage, and 30% showed focal damage. This data was compared with the Caucasian group which showed 43% graded normal, 32% with global damage, and 25% with focal damage (p=0.16). Conclusions. In our study there was no difference in the frequency of globally damaged, focally damaged, and normal graded discs or visual fields between African-American and Caucasian NTG patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report a case of malignant glaucoma after diode laser cyclophotocoagulation. METHOD: Case report. RESULTS: A 45-year-old man with uncontrolled secondary glaucoma in his right eye after corneoscleral graft and cataract extraction underwent diode laser cyclophotocoagulation. The right eye was aphakic, with an intact posterior capsule. Two weeks later, the patient presented with blurred vision, edematous cornea, and flat anterior chamber. The posterior capsule was touching the endothelium. Intraocular pressure was 20 mm Hg. Repeated Nd:YAG laser capsulotomy was effective in reversing the malignant glaucoma attack, and the anterior chamber deepened. CONCLUSION: Malignant glaucoma can occur after diode laser cyclophotocoagulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To describe plateau iris syndrome associated with multiple neuroepithelial cysts of the pars plicata. Methods: Case reports of 3 patients with plateau iris syndrome who were found to have multiple bilateral ciliary body cysts on ultrasound biomicroscopic examination. Results: Ultrasound biomicroscopy revealed classic features of plateau iris syndrome in each patient but also showed multiple neuroepithelial cysts of the ciliary body in each eye. Conclusion: Plateau iris syndrome may be associated with multiple ciliary body cysts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Therapeutic strategies aimed to reverse the pathogenic process, replace diseased tissue, and restore visual function represent the final frontier in treatment of chronic ocular disease. The goal in this approach is improvement, not stabilization or slowing the decline of the disease. Lines of research that can lead to identification of new treatments that could reverse the disease course are reviewed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the new millennium anesthetic agents will be safer and more efficient. Topical anesthesia will be the most frequently used technique. Time- and cost-saving measures will expand the current trend of outpatient surgery and anesthesia will be reduced. Patients' perioperative comfort will improve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.