962 resultados para Nose-to-nose transmission


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we present a Constraint Logic Programming (CLP) based model, and hybrid solving method for the Scheduling of Maintenance Activities in the Power Transmission Network. The model distinguishes from others not only because of its completeness but also by the way it models and solves the Electric Constraints. Specifically we present a efficient filtering algorithm for the Electrical Constraints. Furthermore, the solving method improves the pure CLP methods efficiency by integrating a type of Local Search technique with CLP. To test the approach we compare the method results with another method using a 24 bus network, which considerers 42 tasks and 24 maintenance periods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a new methodology to reduce the probability of occurring states that cause load curtailment, while minimizing the involved costs to achieve that reduction. The methodology is supported by a hybrid method based on Fuzzy Set and Monte Carlo Simulation to catch both randomness and fuzziness of component outage parameters of transmission power system. The novelty of this research work consists in proposing two fundamentals approaches: 1) a global steady approach which deals with building the model of a faulted transmission power system aiming at minimizing the unavailability corresponding to each faulted component in transmission power system. This, results in the minimal global cost investment for the faulted components in a system states sample of the transmission network; 2) a dynamic iterative approach that checks individually the investment’s effect on the transmission network. A case study using the Reliability Test System (RTS) 1996 IEEE 24 Buses is presented to illustrate in detail the application of the proposed methodology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To study the risk of Trypanosoma cruzi domestic transmission using an entomological index and to explore its relationship with household's characteristics and cultural aspects. METHODS: There were studied 158 households in an endemic area in Argentina. Each household was classified according to an entomological risk indicator (number of risky bites/human). A questionnaire was administered to evaluate risk factors among householders. RESULTS: Infested households showed a wide range of risk values (0 to 5 risky bites/human) with skewed distribution, a high frequency of lower values and few very high risk households. Of all collected Triatoma infestans, 44% had had human blood meals whereas 27% had had dogs or chickens blood meals. Having dogs and birds sharing room with humans increased the risk values. Tidy clean households had contributed significantly to lower risk values as a result of low vector density. The infested households showed a 24.3% correlation between time after insecticide application and the number of vectors. But there was no correlation between the time after insecticide application and T. infestans' infectivity. The statistical analysis showed a high correlation between current values of the entomological risk indicator and Trypanosoma cruzi seroprevalence in children. CONCLUSIONS: The risk of T. cruzi domestic transmission assessed using an entomological index show a correlation with children seroprevalence for Chagas' disease and householders' habits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Congestion management of transmission power systems has achieve high relevance in competitive environments, which require an adequate approach both in technical and economic terms. This paper proposes a new methodology for congestion management and transmission tariff determination in deregulated electricity markets. The congestion management methodology is based on a reformulated optimal power flow, whose main goal is to obtain a feasible solution for the re-dispatch minimizing the changes in the transactions resulting from market operation. The proposed transmission tariffs consider the physical impact caused by each market agents in the transmission network. The final tariff considers existing system costs and also costs due to the initial congestion situation and losses. This paper includes a case study for the 118 bus IEEE test case.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a methodology which is based on statistical failure and repair data of the transmission power system components and uses fuzzyprobabilistic modeling for system component outage parameters. Using statistical records allows developing the fuzzy membership functions of system component outage parameters. The proposed hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models allows catching both randomness and fuzziness of component outage parameters. A network contingency analysis to identify any overloading or voltage violation in the network is performed once obtained the system states by Monte Carlo simulation. This is followed by a remedial action algorithm, based on optimal power flow, to reschedule generations and alleviate constraint violations and, at the same time, to avoid any load curtailment, if possible, or, otherwise, to minimize the total load curtailment, for the states identified by the contingency analysis. In order to illustrate the application of the proposed methodology to a practical case, the paper will include a case study for the Reliability Test System (RTS) 1996 IEEE 24 BUS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent decades, all over the world, competition in the electric power sector has deeply changed the way this sector’s agents play their roles. In most countries, electric process deregulation was conducted in stages, beginning with the clients of higher voltage levels and with larger electricity consumption, and later extended to all electrical consumers. The sector liberalization and the operation of competitive electricity markets were expected to lower prices and improve quality of service, leading to greater consumer satisfaction. Transmission and distribution remain noncompetitive business areas, due to the large infrastructure investments required. However, the industry has yet to clearly establish the best business model for transmission in a competitive environment. After generation, the electricity needs to be delivered to the electrical system nodes where demand requires it, taking into consideration transmission constraints and electrical losses. If the amount of power flowing through a certain line is close to or surpasses the safety limits, then cheap but distant generation might have to be replaced by more expensive closer generation to reduce the exceeded power flows. In a congested area, the optimal price of electricity rises to the marginal cost of the local generation or to the level needed to ration demand to the amount of available electricity. Even without congestion, some power will be lost in the transmission system through heat dissipation, so prices reflect that it is more expensive to supply electricity at the far end of a heavily loaded line than close to an electric power generation. Locational marginal pricing (LMP), resulting from bidding competition, represents electrical and economical values at nodes or in areas that may provide economical indicator signals to the market agents. This article proposes a data-mining-based methodology that helps characterize zonal prices in real power transmission networks. To test our methodology, we used an LMP database from the California Independent System Operator for 2009 to identify economical zones. (CAISO is a nonprofit public benefit corporation charged with operating the majority of California’s high-voltage wholesale power grid.) To group the buses into typical classes that represent a set of buses with the approximate LMP value, we used two-step and k-means clustering algorithms. By analyzing the various LMP components, our goal was to extract knowledge to support the ISO in investment and network-expansion planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Between November 2001 and December 2002, 600 dog fecal samples were collected in main squares and public parks of 13 cities in Chile, from the extreme north to the extreme south of the country. The samples were processed in the laboratory by centrifugal sedimentation and the Harada-Mori methods. T. canis eggs were found in 12 cities. Detection rates ranged from 1.9 to 12.5% with an average of 5.2%. Seven percent of the samples had eggs and 9.5% had rhabditoid and/or filariform larvae of Ancylostomatidae. Strongyloides stercoralis were not found. Squares and public parks in Chile pose a potential risk of exposure to visceral, ocular, and/or cutaneous larva migrans syndromes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In context of electricity market, the transmission price is an important tool to an efficient development of the electricity system. The electricity market is influenced by several factors; however the transmission network management is one of the most important aspects, because the network is a natural monopoly. The transmission tariffs can help to regulate the market, for that reason evaluate tariff must have strict criterions. This paper explains several methodologies to tariff the use of transmission network by transmission network users. The methods presented are: Post-Stamp Method; MW-Mile Method; Distribution Factors Methods; Tracing Methodology; Bialek’s Tracing Method and Locational Marginal Price.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the context of electricity markets, transmission pricing is an important tool to achieve an efficient operation of the electricity system. The electricity market is influenced by several factors; however the transmission network management is one of the most important aspects, because the network is a natural monopoly. The transmission tariffs can help to regulate the market, for this reason transmission tariffs must follow strict criteria. This paper presents the following methods to tariff the use of transmission networks by electricity market players: Post-Stamp Method; MW-Mile Method Distribution Factors Methods; Tracing Methodology; Bialek’s Tracing Method and Locational Marginal Price. A nine bus transmission network is used to illustrate the application of the tariff methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An auction model is used to increase the individual profits for market players with products they do not use. A Financial Transmission Rights Auction has the goal of trade transmission rights between Bidders and helps them raise their own profits. The ISO plays a major rule on keep the system in technical limits without interfere on the auctions offers. In some auction models the ISO decide want bids are implemented on the network, always with the objective maximize the individual profits for all bidders in the auction. This paper proposes a methodology for a Financial Transmission Rights Auction and an informatics application. The application receives offers from the purchase and sale side and considers bilateral contracts as Base Case. This goal is maximize the individual profits within the system in their technical limits. The paper includes a case study for the 30 bus IEEE test case.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the prevalence of missed opportunities for congenital syphilis and HIV prevention in pregnant women who had access to prenatal care and to assess factors associated to non-testing of these infections. METHODS: Cross-sectional study comprising a randomly selected sample of 2,145 puerperal women who were admitted in maternity hospitals for delivery or curettage and had attended at least one prenatal care visit, in Brazil between 1999 and 2000. No syphilis and/or anti-HIV testing during pregnancy was a marker for missed prevention opportunity. Women who were not tested for either or both were compared to those who had at least one syphilis and one anti-HIV testing performed during pregnancy (reference category). The prevalence of missed prevention opportunity was estimated for each category with 95% confidence intervals. Factors independently associated with missed prevention opportunity were assessed through multinomial logistic regression. RESULTS: The prevalence of missed prevention opportunity for syphilis or anti-HIV was 41.2% and 56.0%, respectively. The multivariate analysis showed that race/skin color (non-white), schooling (<8 years), marital status (single), income (<3 monthly minimum wages), having sex during pregnancy, history of syphilis prior to the current pregnancy, number of prenatal care visits (<6), and last prenatal visit before the third trimester of gestation were associated with an increased risk of missed prevention opportunity. A negative association with missed prevention opportunity was found between marital status (single), prenatal care site (hospital) and first prenatal visit in the third trimester of gestation. CONCLUSIONS: High rates of non-tested women indicate failures in preventive and control actions for HIV infection and congenital syphilis. Pregnant women have been discontinuing prenatal care at an early stage and are failing to undergo prenatal screening for HIV and syphilis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents the Fuzzy Monte Carlo Model for Transmission Power Systems Reliability based studies (FMC-TRel) methodology, which is based on statistical failure and repair data of the transmission power system components and uses fuzzyprobabilistic modeling for system component outage parameters. Using statistical records allows developing the fuzzy membership functions of system component outage parameters. The proposed hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models allows catching both randomness and fuzziness of component outage parameters. A network contingency analysis to identify any overloading or voltage violation in the network is performed once obtained the system states. This is followed by a remedial action algorithm, based on Optimal Power Flow, to reschedule generations and alleviate constraint violations and, at the same time, to avoid any load curtailment, if possible, or, otherwise, to minimize the total load curtailment, for the states identified by the contingency analysis. For the system states that cause load curtailment, an optimization approach is applied to reduce the probability of occurrence of these states while minimizing the costs to achieve that reduction. This methodology is of most importance for supporting the transmission system operator decision making, namely in the identification of critical components and in the planning of future investments in the transmission power system. A case study based on Reliability Test System (RTS) 1996 IEEE 24 Bus is presented to illustrate with detail the application of the proposed methodology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the growth parameters in infants who were born to HIV-1-infected mothers. METHODS: The study was a longitudinal evaluation of the z-scores for the weight-for-age (WAZ), weight-for-length (WLZ) and length-for-age (LAZ) data collected from a cohort. A total of 97 non-infected and 33 HIV-infected infants born to HIV-1-infected mothers in Belo Horizonte, Southeastern Brazil, between 1995 and 2003 was studied. The average follow-up period for the infected and non-infected children was 15.8 months (variation: 6.8 to 18.0 months) and 14.3 months (variation: 6.3 to 18.6 months), respectively. A mixed-effects linear regression model was used and was fitted using a restricted maximum likelihood. RESULTS: There was an observed decrease over time in the WAZ, LAZ and WLZ among the infected infants. At six months of age, the mean differences in the WAZ, LAZ and WLZ between the HIV-infected and non-infected infants were 1.02, 0.59, and 0.63 standard deviations, respectively. At 12 months, the mean differences in the WAZ, LAZ and WLZ between the HIV-infected and non-infected infants were 1.15, 1.01, and 0.87 standard deviations, respectively. CONCLUSIONS: The precocious and increasing deterioration of the HIV-infected infants' anthropometric indicators demonstrates the importance of the early identification of HIV-infected infants who are at nutritional risk and the importance of the continuous assessment of nutritional interventions for these infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We study a fractional model for malaria transmission under control strategies.Weconsider the integer order model proposed by Chiyaka et al. (2008) in [15] and modify it to become a fractional order model. We study numerically the model for variation of the values of the fractional derivative and of the parameter that models personal protection, b. From observation of the figures we conclude that as b is increased from 0 to 1 there is a corresponding decrease in the number of infectious humans and infectious mosquitoes, for all values of α. This means that this result is invariant for variation of fractional derivative, in the values tested. These results are in agreement with those obtained in Chiyaka et al.(2008) [15] for α = 1.0 and suggest that our fractional model is epidemiologically wellposed.