999 resultados para Micro-imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A published formula containing minimal aortic cross-sectional area and the flow deceleration pattern in the descending aorta obtained by cardiovascular magnetic resonance predicts significant coarctation of the aorta (CoA). However, the existing formula is complicated to use in clinical practice and has not been externally validated. Consequently, its clinical utility has been limited. The aim of this study was to derive a simple and clinically practical algorithm to predict severe CoA from data obtained by cardiovascular magnetic resonance. Seventy-nine consecutive patients who underwent cardiovascular magnetic resonance and cardiac catheterization for the evaluation of native or recurrent CoA at Children's Hospital Boston (n = 30) and the University of California, San Francisco (n = 49), were retrospectively reviewed. The published formula derived from data obtained at Children's Hospital Boston was first validated from data obtained at the University of California, San Francisco. Next, pooled data from the 2 institutions were analyzed, and a refined model was created using logistic regression methods. Finally, recursive partitioning was used to develop a clinically practical prediction tree to predict transcatheter systolic pressure gradient ≥ 20 mm Hg. Severe CoA was present in 48 patients (61%). Indexed minimal aortic cross-sectional area and heart rate-corrected flow deceleration time in the descending aorta were independent predictors of CoA gradient ≥ 20 mm Hg (p <0.01 for both). A prediction tree combining these variables reached a sensitivity and specificity of 90% and 76%, respectively. In conclusion, the presented prediction tree on the basis of cutoff values is easy to use and may help guide the management of patients investigated for CoA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the problem of intensity inhomogeneity athigh magnetic field on magnetic resonance images isaddressed. Specifically, rat brain images at 9.4Tacquired with a surface coil are bias corrected. Wepropose a low- pass frequency model that takes intoaccount not only background-object contours but alsoother important contours inside the image. Twopre-processing filters are proposed: first, to create avolume of interest without contours, and second, toextrapolate the image values of such masked area to thewhole image. Results are assessed quantitatively andvisually in comparison to standard low pass filterapproach, and they show as expected better accuracy inenhancing image intensity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The DEFUSE (n_74) and EPITHET (n_101) studies have in common that a baseline MRI was obtained prior to treatment (tPA in DEFUSE; tPA or placebo in EPITHET) in the 3-6 hour time-window. There were however important methodological differences between the studies. A standardized reanalysis of pooled data was undertaken to determine the effect of these differences on baseline characteristics and study outcomes. Methods: To standardize the studies 1) the DWI and PWI source images were reprocessed and segmented using automated image processing software (RAPID); 2) patients were categorized according to their baseline MRI profile as either Target Mismatch (PWITmax_6/DWI ratio_ 1.8 and an absolute mismatch _15mL), Malignant (DWI or PWITmax_10 lesion _ 100 mL), or No Mismatch. 3) favorable clinical response was defined as NIHSS score of 0-1 or a _8 points improvement on the NIHSSS at day 90. Results: Prior to standardization there was no difference in the proportion of Target Mismatch patients between EPITHET and DEFUSE (54% vs 49%, p_0.6), but the EPITHET study had more patients with the Malignant profile than DEFUSE (35% vs 9%, p_0.01) and fewer patients that had No Mismatch (11% vs 42%, p_0.01). These differences in baseline MRI profiles between EPITHET and DEFUSE were largely eliminated by standardized processing of PWI and DWI images with RAPID software (Target Mismatch 49% vs 48%; Malignant 15% vs 8%; No Mismatch 36% vs 25%; p_NS for all comparisons) Reperfusion was strongly associated with a favorable clinical response in mismatch patients (figure). This relationship was not affected by the standardization procedures (pooled odds ratio of 8.8 based on original data and 6.6 based on standardized data). Conclusion: Standardization of image analyses procedures in acute stroke is important as non-standardized techniques introduce significant variability in DWI and PWI imaging characteristics. Despite methodological differences, the DEFUSE and EPITHET studies show a consistent and robust association between reperfusion and favorable clinical response in Target Mismatch patients regardless of standardization. These data support an RCT of iv tPA in the 3-6 hour time-window for Target Mismatch patients identified using RAPID.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Patients with type 1 diabetes and nephropathy maintain an excess cardiovascular mortality compared with diabetic patients with normoalbuminuria. We sought to evaluate coronary and aortic atherosclerosis in a cohort of asymptomatic type 1 diabetic patients with and without diabetic nephropathy using cardiovascular magnetic resonance imaging. METHODS AND RESULTS: In a cross-sectional study, 136 subjects with long-standing type 1 diabetes without symptoms or history of cardiovascular disease, including 63 patients (46%) with nephropathy and 73 patients with normoalbuminuria, underwent cardiovascular magnetic resonance imaging. All subjects underwent cardiac exercise testing and noninvasive tests for peripheral artery disease and autonomic neuropathy. Coronary artery stenoses were identified in 10% of subjects with nephropathy (versus 0% with normoalbuminuria; P=0.007). Coronary plaque burden, expressed as right coronary artery mean wall thickness (1.7+/-0.3 versus 1.3+/-0.2 mm; P<0.001) and maximum right coronary artery wall thickness (2.2+/-0.5 versus 1.6+/-0.3 mm; P<0.001), was greater in subjects with nephropathy. The prevalence of thoracic (3% versus 0%; P=0.28) and abdominal aortic plaque (22% versus 16%; P=0.7) was similar in both groups. Subjects with and without abdominal aortic plaques had similar coronary plaque burden. CONCLUSIONS: In asymptomatic type 1 diabetes, cardiovascular magnetic resonance imaging reveals greater coronary plaque burden in subjects with nephropathy compared with those with normoalbuminuria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the determining factors of cience-based cooperation in the case of small and micro firms. In this research, we propose an analytical framework based on the resource-based view of the firm and we identify a set of organisational characteristics, which we classify as internal, external and structural factors. Each factor can be linked to at least one reason, from the firm¿s point of view, to cooperate with universities and public research centres. Each reason can, in turn, be used as an indicator of a firm¿s organisational needs or organisational capacities. In order to validate the theoretical model, we estimate a logistic regression that models the propensity to participate in science-based cooperation activities within a sample of 285 small and micro firms located in Barcelona. The results show the key role played by the absorptive capacity of new and small companies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Noninvasive imaging of atherosclerosis is being increasingly used in clinical practice, with some experts recommending to screen all healthy adults for atherosclerosis and some jurisdictions mandating insurance coverage for atherosclerosis screening. Data on the impact of such screening have not been systematically synthesized. OBJECTIVES: We aimed to assess whether atherosclerosis screening improves cardiovascular risk factors (CVRF) and clinical outcomes. DESIGN: This study is a systematic review. DATA SOURCES: We searched MEDLINE and the Cochrane Clinical Trial Register without language restrictions. STUDY ELIGIBILITY CRITERIA: We included studies examining the impact of atherosclerosis screening with noninvasive imaging (e.g., carotid ultrasound, coronary calcification) on CVRF, cardiovascular events, or mortality in adults without cardiovascular disease. RESULTS: We identified four randomized controlled trials (RCT, n=709) and eight non-randomized studies comparing participants with evidence of atherosclerosis on screening to those without (n=2,994). In RCTs, atherosclerosis screening did not improve CVRF, but smoking cessation rates increased (18% vs. 6%, p=0.03) in one RCT. Non-randomized studies found improvements in several intermediate outcomes, such as increased motivation to change lifestyle and increased perception of cardiovascular risk. However, such data were conflicting and limited by the lack of a randomized control group. No studies examined the impact of screening on cardiovascular events or mortality. Heterogeneity in screening methods and studied outcomes did not permit pooling of results. CONCLUSION: Available evidence about atherosclerosis screening is limited, with mixed results on CVRF control, increased smoking cessation in one RCT, and no data on cardiovascular events. Such screening should be validated by large clinical trials before widespread use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to compare myocardial blood flow (MBF) and myocardial flow reserve (MFR) estimates from rubidium-82 positron emission tomography ((82)Rb PET) data using 10 software packages (SPs) based on 8 tracer kinetic models. BACKGROUND: It is unknown how MBF and MFR values from existing SPs agree for (82)Rb PET. METHODS: Rest and stress (82)Rb PET scans of 48 patients with suspected or known coronary artery disease were analyzed in 10 centers. Each center used 1 of 10 SPs to analyze global and regional MBF using the different kinetic models implemented. Values were considered to agree if they simultaneously had an intraclass correlation coefficient >0.75 and a difference <20% of the median across all programs. RESULTS: The most common model evaluated was the Ottawa Heart Institute 1-tissue compartment model (OHI-1-TCM). MBF values from 7 of 8 SPs implementing this model agreed best. Values from 2 other models (alternative 1-TCM and Axially distributed) also agreed well, with occasional differences. The MBF results from other models (e.g., 2-TCM and retention) were less in agreement with values from OHI-1-TCM. CONCLUSIONS: SPs using the most common kinetic model-OHI-1-TCM-provided consistent results in measuring global and regional MBF values, suggesting that they may be used interchangeably to process data acquired with a common imaging protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review covers some of the contributions to date from cerebellar imaging studies performed at ultra-high magnetic fields. A short overview of the general advantages and drawbacks of the use of such high field systems for imaging is given. One of the biggest advantages of imaging at high magnetic fields is the improved spatial resolution, achievable thanks to the increased available signal-to-noise ratio. This high spatial resolution better matches the dimensions of the cerebellar substructures, allowing a better definition of such structures in the images. The implications of the use of high field systems is discussed for several imaging sequences and image contrast mechanisms. This review covers studies which were performed in vivo in both rodents and humans, with a special focus on studies that were directed towards the observation of the different cerebellar layers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the past decade, PET and PET/CT have been widely studied for myocardial perfusion imaging. Several studies demonstrated the incremental value of PET for the diagnostic and prognostic assessment of patients with coronary artery disease. Moreover, PET allows for non-invasively quantifying myocardial blood flow and myocardial flow reserve, that both are recognized as surrogate marker of cardiac event free survival. By enabling the exploration of epicardial disease and the microvasculature, PET constitutes a unique tool to study pathophysiogical mechanisms leading to atherosclerosis genesis. The recent emergence of high-tech hybrid machines may even provide further incremental information about coronary function and morphology. By taking the best of each modality, a better assessment of patients with coronary artery disease is expected. (C) 2011 Elsevier Masson SAS. All rights reserved.