978 resultados para Medical errors
Resumo:
This work presents the results on the development of a high pressure Xe gaseous detector envisaging medical imaging. The detector uses two VUV photosensors operating face-to-face, based on the CsI-MHSP with position discrimination capability. The known effect of the charge gain decrease with the gas pressure is compensated with a light gain using the electroluminescence process. Studies of signal amplitude, energy and position resolution are presented. On the second part, gaseous detectors based on THGEM where studied in order to fulfill the requirements of present and future high energy physics experiments. The work is focused on the application of THGEM in RICH detectors elements: a triple THGEM detector using CsI photocathodes in Ne mixtures was suggested. The ion backflow to the photocathode remains a concern and a limitation; to minimize it, the application of a new hole-structure, THCOBRA, was suggested. Preliminary results foresee good perspectives for the successful application of THCOBRA in ion back-flow suppression. This work contains several methods and measurements of the CsI photocathodes behaviour in radiation gaseous detectors. A long discussion on its issues and possible solutions are presented.
Resumo:
Dissertação de mestrado, Engenharia Informática, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015
Resumo:
This work addresses the joint compensation of IQimbalances and carrier phase synchronization errors of zero- IF receivers. The compensation scheme based on blind-source separation which provides simple yet potent means to jointly compensate for these errors independent of modulation format and constellation size used. The low-complexity of the algorithm makes it a suitable option for real-time deployment as well as practical for integration into monolithic receiver designs.
Resumo:
In this paper, we carry out a detailed performance analysis of the blind source separation based I/Q corrector operating at the baseband. Performance of the digital I/Q corrector is evaluated not only under time-varying phase and gain errors but also in the presence of multipath and Rayleigh fading channels. Performance under low-SNR and different modulation formats and constellation sizes is also evaluated. What is more, BER improvement after correction is illustrated. The results indicate that the adaptive algorithm offers adequate performance for most communication applications hence, reducing the matching requirements of the analog front-end enabling higher levels of integration.
Resumo:
This paper explores the benefits of compensating transmitter gain and phase inbalances in the receiver for quadrature communication systems. It is assumed that the gain and phase imbalances are introduced at the transmitter only. A simple non-data aided DSP algorithm is used at the reciever to compensate for the imbalances. Computer simulation has been formed to study a coherent QPSK communication system.
Resumo:
In this study, we utilise a novel approach to segment out the ventricular system in a series of high resolution T1-weighted MR images. We present a brain ventricles fast reconstruction method. The method is based on the processing of brain sections and establishing a fixed number of landmarks onto those sections to reconstruct the ventricles 3D surface. Automated landmark extraction is accomplished through the use of the self-organising network, the growing neural gas (GNG), which is able to topographically map the low dimensionality of the network to the high dimensionality of the contour manifold without requiring a priori knowledge of the input space structure. Moreover, our GNG landmark method is tolerant to noise and eliminates outliers. Our method accelerates the classical surface reconstruction and filtering processes. The proposed method offers higher accuracy compared to methods with similar efficiency as Voxel Grid.
Resumo:
Researchers want to analyse Health Care data which may requires large pools of compute and data resources. To have them they need access to Distributed Computing Infrastructures (DCI). To use them it requires expertise which researchers may not have. Workflows can hide infrastructures. There are many workflow systems but they are not interoperable. To learn a workflow system and create workflows in a workflow system may require significant effort. Considering these efforts it is not reasonable to expect that researchers will learn new workflow systems if they want to run workflows of other workflow systems. As a result, the lack of interoperability prevents workflow sharing and a vast amount of research efforts is wasted. The FP7 Sharing Interoperable Workflow for Large-Scale Scientific Simulation on Available DCIs (SHIWA) project developed the Coarse-Grained Interoperability (CGI) to enable workflow sharing. The project created the SHIWA Simulation Platform (SSP) to support CGI as a production-level service. The paper describes how the CGI approach can be used for analysis and simulation in Health Care.
Resumo:
Data registration refers to a series of techniques for matching or bringing similar objects or datasets together into alignment. These techniques enjoy widespread use in a diverse variety of applications, such as video coding, tracking, object and face detection and recognition, surveillance and satellite imaging, medical image analysis and structure from motion. Registration methods are as numerous as their manifold uses, from pixel level and block or feature based methods to Fourier domain methods. This book is focused on providing algorithms and image and video techniques for registration and quality performance metrics. The authors provide various assessment metrics for measuring registration quality alongside analyses of registration techniques, introducing and explaining both familiar and state–of–the–art registration methodologies used in a variety of targeted applications.
Resumo:
This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material. This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented. Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future. The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols. To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies. On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents. Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.
Resumo:
Soft-tissue and bone necrosis, although rare in childhood, occasionally occur in the course of infectious diseases, either viral or bacterial, and seem to be the result of hypoperfusion on a background of disseminated intravascular coagulation. Treatment consists in correction of septic shock and control of necrosis. Necrosis, once started, shows extraordinarily rapid evolution, leading to soft-tissue and bone destruction and resulting in anatomic, functional, psychological, and social handicaps. Ten mutilated children were treated from January 1986 to January 1999 in Hospital de Dona Estefaˆ nia, Lisbon, Portugal. One was recovering from hemolytic-uremic syndrome with a severe combined immunodeficiency, another malnourished, anemic child had malaria, and three had chicken pox (in one case complicated by meningococcal septicemia). There were three cases of meningococcal and two of pyocyanic septicemia (one in a burned child and one in a patient with infectious mononucleosis). The lower limbs (knee,leg, foot) were involved in five cases, the face (ear, nose, lip) in four, the perineum in three, the pelvis (inguinal region, iliac crest) in two, the axilla in one, and the upper limb (radius, hand) in two. Primary prevention is based on early recognition of risk factors and timely correction. Secondary prevention consists of immediate etiologic and thrombolytic treatment to restrict the area of necrosis. Tertiary prevention relies on adequate rehabilitation with physiotherapy and secondary operations to obtain the best possible functional and esthetic result.
Resumo:
RESUMO - Os erros de medicação (EM) são uma das principais causas de eventos adversos, estimando-se serem as causas não relacionados com procedimentos cirúrgicos mais frequentes. Estes podem ser classificados por erros latentes ou erros ativos. Objetivos Definiram-se como principais objetivos deste estudo, determinar a prevalência de EM ativos num internamento hospitalar evitados e não evitados, nos momentos da prescrição escrita, transcrição, distribuição e administração, bem como a sua relação com algumas variáveis, como o Grupo farmacológico, Via de administração, Especialidade médica do prescritor e Área médica do médico responsável pelo episódio de internamento (MREI). Metodologia O estudo foi do tipo observacional descritivo de abordagem quantitativa, transversal com recrutamento prospetivo. Foi utilizado um instrumento de observação (check-list) para o registo de todos os EM e das variáveis em cada fase. Resultados Foram observadas 513 unidades amostrais com uma prevalência de 98,2% de EM, num total de 1655 erros dos quais 75% foram evitados. Nas variáveis Grupo farmacológico e Área médica do MREI não foram encontradas relações estatísticas relevantes. Obteve-se um OR=1,97 [1,18;3,27] para medicamentos orais quando comparados aos endovenosos nos erros de prescrição (EP) e um OR=7 [2,77;17,71] quando comparados com os endovenosos na transcrição dos Serviços Farmacêuticos (TSF). A anestesiologia apresentou um OR=0,41 [0,27;0,63] nos EP comparativamente às outras especialidades. Do total de EM observaram-se 30% de erros de prescrição (EP), 20% de erros na transcrição do internamento, 36% de erros na TSF, 2% de erros na distribuição e 12% de erros na administração. Os erros mais prevalentes foram a identificação do prescritor ilegível (16%) e a identificação do doente omissa na TSF (16%). Conclusão Apesar da elevada prevalência de EM observados, a maioria dos erros foram corrigidos e não chegaram ao doente. Tendo em conta os EM observados, a utilização de meios informáticos e o aumento da adesão dos enfermeiros ao procedimento de identificação dos doentes poderão permitir a redução do número de EM em cerca de 80%, reduzindo também a probabilidade de ocorrência de eventos adversos relacionados com os erros ativos na utilização de medicamentos.