971 resultados para Mandibular prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept. Materials and Methods: Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software. Results: Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue. Conclusion: Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:482-491

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were, through a literature review, to point the differences between orbital implants and their advantages and disadvantages, to evaluate prosthesis motility after orbital implants are inserted, and to point the implant wrapping current risks. Sixty-seven articles were reviewed. Enucleation implants can be autoplastics or alloplastics and porous (including natural and synthetic hydroxyapatite [HA]) or nonporous (silicone). Hydroxyapatite is the most related in the literature, but it has disadvantages, too, that is, all orbital implants must be wrapped. Exposure of the porous orbital implant can be repaired using different materials, which include homologous tissue, as well as autogenous graft, xenograft, and synthetic material mesh. The most used materials are HA and porous polyethylene orbital implant. The HA implant is expensive and possibly subject corals to damage, different from porous polyethylene orbital implants. Porous implants show the best prosthesis motility and a minimum rate of implants extrusion. Implant wraps can facilitate smoother entry of the implant into the orbit and allow reattachment of extraocular muscles. They also serve as a barrier between the overlying soft tissue and the rough surface of the implant, protecting implants from exposure or erosion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prosthetic treatments play a role in the rehabilitation of patients with congenital and acquired cleft palate. To prepare the surgical field and/or correct inevitable sequelae of the surgery, the rehabilitation with obturator prosthesis is an auxiliary or complementary treatment to surgical treatments. In cases where the surgical treatment is contraindicated, the prosthetic rehabilitation becomes a definitive treatment. The denture is planned and fabricated according to each patient. Therefore, the aim of this study was to discuss the prosthetic rehabilitation performed in patients with oronasal communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Osseointegrated implants in craniofacial reconstructions improve prostheses retention and stability and comfort and safety for a patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgical technique associated to a retention system that provides favorable tension distribution to implants. Furthermore, patient expectation, esthetics, function, and anatomic limitations must be evaluated during treatment planning. Therefore, the aims of this study were to present available retention systems to implant-supported craniofacial prosthesis and to highlight the advantages, indications, and limitations. A literature review was conducted through a MEDLINE search. Sixteen articles and 2 textbooks met the inclusion criteria and were included in the review. It was concluded that the success of craniofacial rehabilitation with implants depends on an adequate surgical technique and an adequate selection of a retention system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the frequency of removable partial dentures (RPD) at the Aracatuba Dental School.Methods: The study was conducted by analysing 412 clinical history of patients attended at the RPD clinics in the period from 2000 to 2007.Results: 412 charts were analysed: 148 (35.9%) men and 264 (64.1%) women. The mean age was 53.8 years (men) and 52.4 years (women). A total of 556 dentures were made; of these, 233 (41.90%) were maxillary and 323 (58.09%) were mandibular dentures. The most frequent Kennedy classification found was Class III (maxilla) and Class I (mandible). In the maxilla, 55% (126) of the major connectors were of the anterior-posterior palatal bar, while in the mandible, 64% (202) were the lingual bar. As regards the claps, 401 were circumferential and 318 were bar claps.Conclusion: The mean age of the patients was 52.9 years with higher prevalence of female patients; the most frequent Kennedy's classification was Class I in mandible and Class III in maxilla; the most common major connector was anterior-posterior palatal bar for maxilla and lingual bar for mandible; the circumferential clasps were the most common retainer used in both jaws.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 310316 Background. Generalized aggressive periodontitis (GAP) in primary teeth is a rare periodontal disease that occurs during or soon after eruption of the primary teeth. An association with systemic diseases is a possibility. Case Report. A 4-year-old Brazilian girl presented with GAP involving the entire primary dentition. The patient and her parents and sister were subjected to microbiological testing to identify the microorganisms involved in the disease. The patient underwent tooth extraction to eradicate the disease and received a prosthesis for the restoration of masticatory function. After the permanent teeth erupted, fixed orthodontic appliances were place to restore dental arch form and occlusion. Conclusions. The results show the importance of an early diagnosis of GAP and of a multidisciplinary approach involving laboratory and clinical management to treat the disease and to restore masticatory function, providing a better quality of life for patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although tumors of minor salivary glands are rare, the pleomorphic adenoma is the most common pathology among the benign neoplasm and can be found with high prevalence in the junction between hard palate and soft palate. The treatment of choice for most of maxillary tumors is surgical through either a total or partial maxillectomy. However, surgical defects caused by such type of treatment lead to both clinical and psychologic disorders for the patient. The immediate oral rehabilitation using interim palate obturator after maxillectomy provides optimization on the healing process, recovers the stomatognathic functions after surgery, and avoids psychosocial sequelae for the patients. This clinical report aimed to present the rehabilitation with immediate palate obturator of a patient who underwent a partial maxillectomy due to a hard palate pleomorphic adenoma of minor salivary glands. We report the clinical importance of the prosthetic rehabilitation and the improvements on both quality of life and stomatognathic functions of this patient. It can be concluded that the immediate rehabilitation of the patient after partial maxillectomy by using an interim palate obturator was a great option and provided clinical benefits in the immediate postoperative period, improving the patient's quality of life, allowing the patient's reinsertion into society, and reducing the surgical treatment sequelae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the color stability of MDX4-4210 maxillofacial elastomer with opacifier addition submitted to chemical disinfection and accelerated aging.Materials and Methods: Ninety specimens were obtained from Silastic MDX4-4210 silicone. The specimens were divided into three groups (n = 30): Group I: colorless, Group II: barium sulfate opacifier, Group III: titanium dioxide opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was conducted three times a week for 2 months. Afterward, the specimens were submitted to different periods of accelerated aging. Color evaluation was carried out after 60 days (disinfection period) and after 252, 504, and 1008 hours of accelerated aging, using a reflection spectrophotometer. Color alterations were calculated by the CIE L*a*b* system. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05).Results: Group II exhibited the lowest color change, whereas Group III the highest (p < 0.05), regardless of the chemical disinfection and accelerated aging periods.Conclusion: Opacifier addition, chemical disinfection, and accelerated aging procedures affected the color stability of the maxillofacial silicone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous origin and bruxism were divided into 2 groups treated with splints in maximum intercuspation (I) or centric relation (II). Clinical, electrognathographic and electromyographic examinations were performed before and 3 months after therapy. Data were analyzed by the Student's t test. Differences at 5% level of probability were considered statistically significant. There was a remarkable reduction in pain symptomatology, without statistically significant differences (p>0.05) between the groups. There was mandibular repositioning during therapy, as demonstrated by the change in occlusal contacts on the splints. Electrognathographic examination demonstrated a significant increase in maximum left lateral movement for group I and right lateral movement for group II (p<0.05). There were no significant differences (p>0.05) in the electromyographic activities at rest after utilization of both splints. In conclusion, both occlusal splints were effective for pain control and presented similar action. The results suggest that maximum intercuspation may be used for fabrication of occlusal splints in patients with occlusal stability without large discrepancies between centric relation and maximum intercuspation. Moreover, this technique is simpler and less expensive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The record of electrical activity of elevator muscles in mandible is important for the evaluation of muscular potency and diagnosis of neuromuscular pathologies, which allows prevention and treatment. The aim of this study was to define silent periods (SPs) and the importance in dentistry and compare the SPs in masticatory muscles of dentate and edentulous patients wearing prosthesis considering the presence or absence of craniomandibular dysfunction (CMD).Materials and Methods: Literature review in PubMed database.Discussion: Silent periods are isolated pulses of transcranial magnetic stimulation in the primary motor cortex during voluntary muscular activity that generates an interruption of muscular activity for hundredths of milliseconds. The SP duration depends on the patient (dentate or edentulous), type of stimulus, and presence of CMD.Conclusions: The SP is higher in complete edentulous patients and in individuals with occlusal disharmonies than in dentate patients without CMDs. The treatment of CMDs through occlusal therapy decreases SP duration.