919 resultados para Mandibular advancement device
Resumo:
The design of the ParalAB device facilitates transfer of the path of insertion from the diagnostic cast to the mouth quickly and efficiently.
Resumo:
We investigated whether Melipona quadrifasciata worker mandibular gland secretions contribute directly to their cuticular hydrocarbon profile. The mandibular gland secretion composition and cuticular surface compounds of newly emerged worker bees, nurse bees, and foragers were determined by gas chromatography and mass spectrometry and compared. Both the mandibular gland secretions and the cuticular surface compounds of all worker stages were found to be composed almost exclusively of hydrocarbons. Although the relative proportion of hydrocarbons from the cuticular surface and gland secretion was statistically different, there was a high similarity in the qualitative composition between these structures in all groups of bees. © FUNPEC-RP.
Resumo:
In adults, the mandibular accessory foramina are variables and are located on the medial surface of the mandible in positions above or below of the mandibular foramen. The aim of this study was to evaluate the incidence of the mandibular accessory foramina in Brazilians human mandibles and discuss the clinical aspects related to the presence of these foramina. Were evaluated 222 mandibles, adults, irrespective of gender. Was observed that 27.93% and 43.24% of the mandibles presented at least one mandibular accessory foramina located on the medial surface in position below and above, respectively, of the mandibular foramen. Unilaterally, the mandibular accessory foramina were observed below and above of the mandibular foramen in 22.07% and 25.22%, of the mandibles, respectively, and 5.85% and 18.02% bilaterally, respectively. This study demonstrated that the incidence of mandibular accessory foramen in the Brazilian population is significant and should be considered in the planning and execution of procedures in several areas of dental clinical practice in order to avoid complications.
Resumo:
Introduction: This present study's purpose is to evaluate the degree of paresthesia and recovery of inferior alveolar nerve in patients with mandible fractures who underwent surgical treatment. Material and methods: Nineteen patients were evaluated (27 hemimandibles) at six different times: preoperative (T1), postoperative 1 week (T2), postoperative 1 month (T3), postoperative 3 months (T4), postoperative 6 months (T5), and postoperative 1 year (T6). Subjective and objective methods were used for this evaluation. Results: The results were analyzed using likelihood ratio chi-square test for the hypothesis of no association between indicators of sensitivity and responses to the questionnaire, and the Cochran-Mantel-Haenszel test for equality hypothesis. All objective tests showed a statistically significant worsening in sensitivity at T2 (p < 0. 0001) and a significant improvement after T4 (α < 0. 05). The subjective tests showed an association with the objectives tests, and improvement in sensitivity after T4 (p < 0. 0001) was noted. Discussion: The first postoperative week is the period in which there are major changes with respect to sensitivity, and after 3 months postoperatively, the recovery reaches its apex with little difference observed after this period. In this research 100 % of the patients analyzed recovered all sensibility until T6. © 2012 Springer-Verlag.
Resumo:
Odontogenics tumors are uncommon in the dog. Ameloblastoma is considered a benign, aggressive and non-inductive odontogenic neoplasia commonly located in the incisor teeth. Its conclusive diagnosis is obtained by histopathological examination. Due to the expansive nature of this neoplasia, its resection needs to have an adequate surgical margin so it will have excellent prognostics. A canine, male, Pekingese, 8 years old had an increased volume in the rostral region of the mandible, adhered, consistency moderately firm. Radiography revealed extensive mandibular bone lysis caused by the neoplasia. Biopsy identified the tumor as ameloblastoma. Combining data from the clinical, radiographic and histopatological study and after explain to the owner regarding the postoperative esthetic it was held a bilateral rostral mandibulectomy. The fragment removed was assessed radiographically and histopathologically for evidence of tumor at its edges. The patient is active and healthy without evidence of metastasis or recurrence. The radiographic and histopathologic evaluation of edges of the fragment showed no tumor evidence. The patient is active and healthy without evidence of metastasis or recurrence since January 2010 when mandibulectomy was performed.
Resumo:
Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking reconstruction plate in the fixation of atrophic mandible fractures. Polyurethane mandibles with a simulated linear fracture at the midline were used as substratum. Results show that resistance of the fixation is poor when one and two screws are used on each side of the fracture. Three screws on each side of the fracture significantly increases the resistance to displacement. However, no additional strength is added to the construct when more than three screws per side are used. © 2013 International Association of Oral and Maxillofacial Surgeons.
Resumo:
In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL (xsuperconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level. © 2002-2011 IEEE.
Resumo:
Osteochondroma is one of the most common benign tumors of the skeleton. This tumor is rare in the craniofacial region, with the most common sites of occurrence being the coronoid process of the mandible and the mandibular condyle. Traditionally, the treatments of these lesions include total condylectomy or local resection of the lesion. Conservative condylectomy procedure with reshaping of the remaining condylar neck and repositioning of the articular disk has been suggested. This article aimed to describe a 35-year-old woman with osteochondroma in the left mandibular condyle who was treated by conservative condylectomy. The patient has been free of recurrence for 2 years, showing good aesthetic and functional stability. Copyright © 2013 by Mutaz B. Habal, MD.
Resumo:
PURPOSE: The present case describes an inferior alveolar nerve lateralization for implant placement that caused mandible fracture a few days after surgery. CLINICAL REPORT: In this case, a 56-year-old female patient who had a severely atrophied jaw and showing bone height less than 7 mm from the bone crest and the mandibular canal was submitted to surgery lateralization of the inferior alveolar conducted with piezzo. Even with all postoperative care, the patient suffered an incomplete fracture of the mandible a few days after lateralization of the inferior alveolar nerve for implant placement. The patient was treated with soft diet and medications for pain and antibiotics, besides removing the implant associated with the fracture. CONCLUSION: It is suggested that this procedure may be conducted in 2 operative periods: firstly, the lateralization of the inferior alveolar; and secondly, after a period of 3 months, the implant placement in a situation of more bone stability. Copyright © 2013 by Mutaz B. Habal, MD.
Resumo:
Objectives: The aim of this study was to evaluate the stress distribution in mandibular free-end removable partial dentures (RPD) associated with FPD in the abutment teeth considering different inclinations of the residual ridge: (1) horizontal and (2) distal descending ridges and two designs of free-end RPD with different attachment systems were tested: (1) clasp and (2) system ERA. Methods. Axial loads (100 N) were applied on the teeth of the RPD. The images were recorded and the stress distribution was evaluated through photoelastic fringes. Results. In general, the distal descending ridge presented more photoelastic fringes in the region of the roots of the abutment teeth while the horizontal ridge exhibited higher compression in the base of the prosthesis. In the horizontal ridge, the denture with clasp presented more favourable stress distribution than the denture with the system ERA. In the distal descending ridge, the denture with the system ERA relieved the region of the abutment teeth and overloaded the residual ridge. Conclusion: The horizontal ridge presented more favourable performance; the dentures with clasp exhibited better performance for both ridges evaluated; the denture with the system ERA presented better results in the distal descending ridge. © 2013 Informa Healthcare.
Resumo:
Brazil has the largest cattle herd in the world with approximately 200 million head. An important feature of the Brazilian cattle industry is that most of its herd is raised on pasture, which constitutes one of the most economical and practical ways to produce and provide food for cattle. However, this production model is mishandled and can lead to soil degradation. Maintaining soil quality is essential for the conservation of natural ecosystems and the areas of production, thus soil quality improves the conditions for biogeochemical cycles. In this context, the objective of this study was to develop a device for testing the Inderbitzen way of assessing soil erodibility in two situations of usage and occupation. Therefore, one area was used as a sample collection occupied by grazing and the other as a forest fragment; both located in the city of Sorocaba in Sao Paulo State, Brazil. Thus, we concluded that the proposed device - the Inderbitzen - proved capable of assessing soil erodibility of the pasture and remnant forest. Accordingly, there was a tendency for a smaller loss of forest soils in the remnant when compared to the degraded pasture. The greatest resistance of the soil erosion in the forest remnant may be associated with the amount of organic matter released by the forest litter in all its diversity, influencing the quality of the structure of aggregates. © 2013 WIT Press.
Resumo:
Condylar hyperplasia is an overdevelopment of the condyle, which may manifest unilaterally or bilaterally. This pathological condition can lead to facial asymmetry, malocclusion, and dysfunction of the temporomandibular joint. The etiology and pathogenesis of condylar hyperplasia remain uncertain, but it has been suggested that its etiology may be associated with hormonal factors, trauma, and hereditary hypervascularity, affecting both genders. The diagnosis is made by clinical examination, and radiological imaging, and additionally, bone scintigraphy, is a fundamental resource for determining whether the affected condyle shows active growth. Patients with active condylar hyperplasia management have better results when they are subjected to the high condylectomy procedure. The authors report a case in a 20-year-old female subject with unilateral active condylar hyperplasia who was treated by high condylectomy. The patient has been followed up for 4 years without signs of recurrence and with good functional stability of the occlusion. © 2013 by Mutaz B. Habal, MD.
Resumo:
Fractures of the severely atrophic (<10 mm) edentulous mandible are not common, and these fractures with a vertical height of 10 mm or less have long been recognized as being particularly problematic. Although there are advances in the treatment of the atrophic mandibular fracture, the treatment remains controversial. There are some options for treatment planning because of using small miniplates to large reconstruction plates. However, when the fixation method fails, it causes malunion, nonunion, and/or infection, and sometimes it has been associated with large bone defects. The authors describe a clinical report of a failed miniplate fixation for atrophic mandibular fracture management. The authors used a load-bearing reconstruction plate combined with autogenous bone graft from iliac crest for this retreatment. The authors show a follow-up of 6 months, with union of the fracture line and no complication postoperatively. © 2013 by Mutaz B. Habal, MD.
Resumo:
Background: Dental implants, indicated for re-establishing both mastigatory and aesthetic functions, can be placed in the sockets immediately after tooth extraction. Most studies investigate the anterior and upper regions of the dental arch, whereas few examine longitudinal appraisal of immediate implant installation in the mandibular molar region. Objective: The aim of this retrospective study was to evaluate the success rate of immediate dental implants placement in mandibular molars within a follow-up period as long as 8 years. Materials and methods: Seventy-four mandibular molar implants after non-traumatic tooth extraction between 2002 and 2008 were examined in the study. All implants were evaluated radiographically immediately after prosthesis placement, 1 year after implantation, and by the end of the experimental period, in 2010. Clinical evaluation was done according to [Albrektsson et al. (1986) The International Journal of Oral & Maxillofacial Implants, 1, 11-25] success criteria for marginal bone loss. The mean bone losses, calculated as the difference between the final evaluation measures and those taken by the end of the first year of implant, were compared using Kruskal-Wallis test with a significance level of 5%. Results: All implants presented clinical and radiographic stable conditions, that is, 100% success rate. Significant bone loss was not found between final evaluation and that of the first functional year (P > 0.05). Conclusion: Immediate implant placement of mandibular molars proved to be a viable surgical treatment given the high success rate up to 8 years after implantation. © 2012 John Wiley & Sons A/S.
Resumo:
Objective: The goal of this study was to evaluate the efficacy of the Self-Adjusting File (SAF) and ProTaper for removing calcium hydroxide [Ca(OH)2] from root canals. Material And Methods: Thirty-six human mandibular incisors were instrumented with the ProTaper system up to instrument F2 and filled with a Ca(OH)2-based dressing. After 7 days, specimens were distributed in two groups (n=15) according to the method of Ca(OH)2 removal. Group I (SAF) was irrigated with 5 mL of NaOCl and SAF was used for 30 seconds under constant irrigation with 5 mL of NaOCl using the Vatea irrigation device, followed by irrigation with 3 mL of EDTA and 5 mL of NaOCl. Group II (ProTaper) was irrigated with 5 mL of NaOCl, the F2 instrument was used for 30 seconds, followed by irrigation with 5 mL of NaOCl, 3 mL of EDTA, and 5 mL of NaOCl. In 3 teeth Ca(OH)2 was not removed (positive control) and in 3 teeth canals were not filled with Ca(OH)2 (negative control). Teeth were sectioned and prepared for the scanning electron microscopy. The amounts of residual Ca(OH)2 were evaluated in the middle and apical thirds using a 5-score system. Results: None of the techniques completely removed the Ca(OH)2 dressing. No difference was observed between SAF and ProTaper in removing Ca(OH)2 in the middle (P=0.11) and the apical (P=0.23) thirds. Conclusion: The SAF system showed similar efficacy to rotary instrument for removal of Ca(OH)2 from mandibular incisor root canals.