956 resultados para In-row spacing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare image quality and radiation dose of thoracoabdominal computed tomography (CT) angiography at 80 and 100 kVp and to assess the feasibility of reducing contrast medium volume from 60 to 45 mL at 80 kVp. MATERIALS AND METHODS: This retrospective study had institutional review board approval; informed consent was waived. Seventy-five patients who had undergone thoracoabdominal 64-section multidetector-row CT angiography were divided into 3 groups of 25 patients each. Patients of groups A (tube voltage, 100 kVp) and B (tube voltage, 80 kVp) received 60 mL of contrast medium at 4 mL/s. Patients of group C (tube voltage, 80 kVp) received 45 mL of contrast medium at 3 mL/s. Mean aortoiliac attenuation, image noise, and contrast-to-noise ratio were assessed. The measurement of radiation dose was based on the volume CT dose index. Three independent readers assessed the diagnostic image quality. RESULTS: Mean aortoiliac attenuation for group B (621.1 +/- 90.5 HU) was significantly greater than for groups A and C (485.2 +/- 110.5 HU and 483.1 +/- 119.8 HU; respectively) (P < 0.001). Mean image noise was significantly higher for groups B and C than for group A (P < 0.05). The contrast-to-noise ratio did not significantly differ between the groups (group A, 35.0 +/- 13.8; group B, 31.7 +/- 10.1; group C, 27.3 +/- 11.5; P = 0.08). Mean volume CT dose index in groups B and C (5.2 +/- 0.4 mGy and 4.9 +/- 0.3 mGy, respectively) were reduced by 23.5% and 27.9%, respectively, compared with group A (6.8 +/- 0.8 mGy) (P < 0.001). The average overall diagnostic image quality for the 3 groups was graded as good or better. The score for group A was significantly higher than that for group C (P < 0.01), no difference was seen between group A and B (P = 0.92). CONCLUSIONS: Reduction of tube voltage from 100 to 80 kVp for thoracoabdominal CT angiography significantly reduces radiation dose without compromising image quality. Reduction of contrast medium volume to 45 mL at 80 kVp resulted in lower but still diagnostically acceptable image quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The antimycobacterial activity of nitro/ acetamido alkenol derivatives and chloro/ amino alkenol derivatives has been analyzed through combinatorial protocol in multiple linear regression (CP-MLR) using different topological descriptors obtained from Dragon software. Among the topological descriptor classes considered in the study, the activity is correlated with simple topological descriptors (TOPO) and more complex 2D autocorrelation descriptors (2DAUTO). In model building the descriptors from other classes, that is, empirical, constitutional, molecular walk counts, modified Burden eigenvalues and Galvez topological charge indices have made secondary contribution in association with TOPO and / or 2DAUTO classes. The structure-activity correlations obtained with the TOPO descriptors suggest that less branched and saturated structural templates would be better for the activity. For both the series of compounds, in 2DAUTO the activity has been correlated to the descriptors having mass, volume and/ or polarizability as weighting component. In these two series of compounds, however, the regression coefficients of the descriptors have opposite arithmetic signs with respect to one another. Outwardly these two series of compounds appear very similar. But in terms of activity they belong to different segments of descriptor-activity profiles. This difference in the activity of these two series of compounds may be mainly due to the spacing difference between the C1 (also C6) substituents and rest of the functional groups in them.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two rotational-grazing systems, a 13-paddock and a 4-paddock, have been demonstrated on CRP land near Corning, Iowa since 1991 and this report summarizes the 2001 production data. Establishment of this project was to show economically feasible grass alternatives to row crops and CRP for steeply sloping (9% - 14% slope), highly-erodible land (HEL). Stocking rates were 1.57 and 1.72 acres per pair on the 13- and 4-paddock systems, respectively. In a 119 day grazing season calves gained 2.23 and 2.27 lbs/day for the 13- and 4-paddock systems, while cows gained 51.4 and 113.4 lbs, respectively. While some system hay growth was utilized to stave off drought conditions, there was a net hay gain of 11 and 5.5 bales of hay for the 13- and 4-paddock systems, respectively

Relevância:

30.00% 30.00%

Publicador:

Resumo:

HYPOTHESIS We hypothesized that arthroscopic rotator cuff repairs using leukocyte- and platelet-rich fibrin (L-PRF) in a standardized, modified protocol is technically feasible and results in a higher vascularization response and watertight healing rate during early healing. METHODS Twenty patients with chronic rotator cuff tears were randomly assigned to 2 treatment groups. In the test group (N = 10), L-PRF was added in between the tendon and the bone during arthroscopic rotator cuff repair. The second group served as control (N = 10). They received the same arthroscopic treatment without the use of L-PRF. We used a double-row tension band technique. Clinical examinations including subjective shoulder value, visual analog scale, Constant, and Simple Shoulder Test scores and measurement of the vascularization with power Doppler ultrasonography were made at 6 and 12 weeks. RESULTS There have been no postoperative complications. At 6 and 12 weeks, there was no significant difference in the clinical scores between the test and the control groups. The mean vascularization index of the surgical tendon-to-bone insertions was always significantly higher in the L-PRF group than in the contralateral healthy shoulders at 6 and 12 weeks (P = .0001). Whereas the L-PRF group showed a higher vascularization compared with the control group at 6 weeks (P = .001), there was no difference after 12 weeks of follow-up (P = .889). Watertight healing was obtained in 89% of the repaired cuffs. DISCUSSION/CONCLUSIONS Arthroscopic rotator cuff repair with the application of L-PRF is technically feasible and yields higher early vascularization. Increased vascularization may potentially predispose to an increased and earlier cellular response and an increased healing rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study uses the widths, the spacing and the grain-size pattern of Oligo/Miocene alluvial fan conglomerates in the central segment of the Swiss Alpine foreland to reconstruct the topographic development of the Alps. These data are analysed with models of longitudinal stream profile development, to propose that the Alpine topography evolved from an early transient state where streams adjusted to rock uplift by headward retreat, to a mature phase where any changes in rock uplift were accommodated by vertical incision. The first stage comprises the time interval between ca 31 Ma and 22 Ma, when the Alpine streams deposited many small fans with a lateral spacing of <30 km in the north Alpine foreland. As the range evolved, the streams joined and the fans coalesced into a few large depositional systems with a lateral spacing of ca 80 to 100 km at 22 Ma. The models used here suggest that the overall elevation of the Alps increased rapidly within <5 Myr. The variability in pebble size increased either due to variations in sediment supply, enhanced orographic effects, or preferentially due to a change towards a stormier palaeoclimate. By 22 Ma, only two large rivers carried material into the foreland fans, suggesting that the major Alpine streams had established themselves. This second phase of stable drainage network was maintained until ca 5 Ma, when the uplift and erosion of the Molasse started and streams were redirected both in the Alps and in the foreland. This study illustrates that sedimentological archives of foreland basins can be used to reconstruct the chronology of the topographic development of mountain belts. It is suggested that the finite elevation of mountainous landscapes is reached early during orogeny and can be maintained for millions of years, provided that erosion is efficient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This participatory action-research project addressed the hypothesis that strengthened community and women's capacity for self-development will lead to action to address maternal health problems and the prevention of maternal morbidity and mortality in Mali. Research objectives were: (1) to undertake a comparative cross-sectional study of the association of community capacity with improved maternal health in rural areas of Sanando, Mali, where capacity building interventions have taken place in some villages but not in others. (2) to describe women's maternal health status, access to and use of maternal health services given their residence in program or comparison communities.^ The participatory action research project was an integrated qualitative and quantitative study using participatory rural appraisal exercises, semi-structured group interviews and a cross-sectional survey.^ Factors related to community capacity for self-development were identified: community harmony; an understanding of the benefits of self-development; dynamic leadership; and a structure to implement collective activities.^ A distinct difference between the program and comparison villages was the commitment to train and support traditional birth attendants (TBAs). The TBAs in the program villages work in the context of the wider, integrated self-development program and, 10 years after their initial training, the TBAs continue to practice.^ Many women experience labor and childbirth alone or are attended by an untrained relative in both program and comparison villages. Nevertheless a significant change is apparent, with more women in program villages than in comparison villages being assisted by the TBAs. The delivery practices of the TBAs reveal the positive impact of their training in the "three cleans" (clean hands of the assistant, clean delivery surface and clean cord-cutting). The findings of this study indicate a significant level of unmet need for child spacing methods in all villages.^ The training and support of TBAs in the program villages yielded significant improvements in their delivery practices, and resulting outcomes for women and infants. However, potential exists for further community action. Capacities for self-development have not yet been directed toward an action plan encompassing other Safe Motherhood interventions, including access to family planning services and emergency obstetric care services. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We track dated firn horizons within 400 MHz short-pulse radar profiles to find the continuous extent over which they can be used as historical benchmarks to study past accumulation rates in West Antarctica. The 30-40 cm pulse resolution compares with the accumulation rates of most areas. We tracked a particular set that varied from 30 to 90 m in depth over a distance of 600 km. The main limitations to continuity are fading at depth, pinching associated with accumulation rate differences within hills and valleys, and artificial fading caused by stacking along dips. The latter two may be overcome through multi-kilometer distances by matching the relative amplitude and spacing of several close horizons, along with their pulse forms and phases. Modeling of reflections from thin layers suggests that the - 37 to - 50 dB range of reflectivity and the pulse waveforms we observed are caused by the numerous thin ice layers observed in core stratigraphy. Constructive interference between reflections from these close, high-density layers can explain the maintenance of reflective strength throughout the depth of the firn despite the effects of compaction. The continuity suggests that these layers formed throughout West Antarctica and possibly into East Antarctica as well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1944/1945 wurde in Cham-Hagendorn eine Wassermühle ausgegraben, die dank ihrer aussergewöhnlich guten Holzerhaltung seit langem einen prominenten Platz in der Forschung einnimmt. 2003 und 2004 konnte die Kantonsarchäologie Zug den Platz erneut archäologisch untersuchen. Dabei wurden nicht nur weitere Reste der Wassermühle, sondern auch Spuren älterer und jüngerer Anlagen geborgen: eine ältere und eine jüngere Schmiedewerkstatt (Horizont 1a/Horizont 3) sowie ein zweiphasiges Heiligtum (Horizonte 1a/1b). All diese Anlagen lassen sich nun in das in den neuen Grabungen erkannte stratigraphische Gerüst einhängen (s. Beil. 2). Dank der Holzerhaltung können die meisten Phasen dendrochronologisch datiert werden (s. Abb. 4.1/1a): Horizont 1a mit Schlagdaten zwischen 162(?)/173 und 200 n. Chr., Horizont 1b um 215/218 n. Chr. und Horizont 2 um 231 n. Chr. Ferner konnten in den neuen Grabungen Proben für mikromorphologische und archäobotanische Untersuchungen entnommen werden (Kap. 2.2; 3.11). In der vorliegenden Publikation werden der Befund und die Baustrukturen vorgelegt, (Kap. 2), desgleichen sämtliche stratifizierten Funde und eine umfassende Auswahl der 1944/1945 geborgenen Funde (Kap. 3). Dank anpassender Fragmente, sog. Passscherben, lassen sich diese zum Teil nachträglich in die Schichtenabfolge einbinden. Die mikromorphologischen und die archäobotanischen Untersuchungen (Kap. 2.2; 3.11) zeigen, dass der Fundplatz in römischer Zeit inmitten einer stark vom Wald und dem Fluss Lorze geprägten Landschaft lag. In unmittelbarer Nähe können weder eine Siedlung noch einzelne Wohnbauten gelegen haben. Die demnach nur gewerblich und sakral genutzten Anlagen standen an einem Bach, der vermutlich mit jenem Bach identisch ist, der noch heute das Groppenmoos entwässert und bei Cham-Hagendorn in die Lorze mündet (s. Abb. 2.4/1). Der antike Bach führte wiederholt Hochwasser ─ insgesamt sind fünf grössere Überschwemmungsphasen auszumachen (Kap. 2.2; 2.4). Wohl anlässlich eines Seehochstandes durch ein Überschwappen der Lorze in den Bach ausgelöst, müssen diese Überschwemmungen eine enorme Gewalt entwickelt haben, der die einzelnen Anlagen zum Opfer fielen. Wie die Untersuchung der Siedlungslandschaft römischer Zeit rund um den Zugersee wahrscheinlich macht (Kap. 6 mit Abb. 6.2/2), dürften die Anlagen von Cham-Hagendorn zu einer in Cham-Heiligkreuz vermuteten Villa gehören, einem von fünf grösseren Landgütern in diesem Gebiet. Hinweise auf Vorgängeranlagen fehlen, mit denen die vereinzelten Funde des 1. Jh. n. Chr. (Kap. 4.5) in Verbindung gebracht werden könnten. Diese dürften eher von einer der Überschwemmungen bachaufwärts weggerissen und nach Cham-Hagendorn eingeschwemmt worden sein. Die Nutzung des Fundplatzes (Horizont 1a; s. Beil. 6) setzte um 170 n. Chr. mit einer Schmiedewerkstatt ein (Kap. 2.5.1). Der Fundanfall, insbesondere die Schmiedeschlacken (Kap. 3.9) belegen, dass hier nur hin und wieder Geräte hergestellt und repariert wurden (Kap. 5.2). Diese Werkstatt war vermutlich schon aufgelassen und dem Verfall preisgegeben, als man 200 n. Chr. (Kap. 4.2.4) auf einer Insel zwischen dem Bach und einem Lorzearm ein Heiligtum errichtete (Kap. 5.3). Beleg für den sakralen Status dieser Insel ist in erster Linie mindestens ein eigens gepflanzter Pfirsichbaum, nachgewiesen mit Pollen, einem Holz und über 400 Pfirsichsteinen (Kap. 3.11). Die im Bach verlaufende Grenze zwischen dem sakralen Platz und der profanen Umgebung markierte man zusätzlich mit einer Pfahlreihe (Kap. 2.5.3). In diese war ein schmaler Langbau integriert (Kap. 2.5.2), der an die oft an Temenosmauern antiker Heiligtümer angebauten Portiken erinnert und wohl auch die gleiche Funktion wie diese gehabt hatte, nämlich das Aufbewahren von Weihegaben und Kultgerät (Kap. 5.3). Das reiche Fundmaterial, das sich in den Schichten der ersten Überschwemmung fand (s. Abb. 5./5), die um 205/210 n. Chr. dieses Heiligtum zerstört hatte, insbesondere die zahlreiche Keramik (Kap. 3.2.4), und die zum Teil auffallend wertvollen Kleinfunde (Kap. 3.3.3), dürften zum grössten Teil einst in diesem Langbau untergebracht gewesen sein. Ein als Glockenklöppel interpretiertes, stratifiziertes Objekt spricht dafür, dass die fünf grossen, 1944/1945 als Stapel aufgefundenen Eisenglocken vielleicht auch dem Heiligtum zuzuweisen sind (Kap. 3.4). In diesen Kontext passen zudem die überdurchschnittlich häufig kalzinierten Tierknochen (Kap. 3.10). Nach der Überschwemmung befestigte man für 215 n. Chr. (Kap. 4.2.4) das unterspülte Bachufer mit einer Uferverbauung (Kap. 2.6.1). Mit dem Bau eines weiteren, im Bach stehenden Langbaus (Kap. 2.6.2) stellte man 218 n. Chr. das Heiligtum auf der Insel in ähnlicher Form wieder her (Horizont 1b; s. Beil. 7). Von der Pfahlreihe, die wiederum die sakrale Insel von der profanen Umgebung abgrenzte, blieben indes nur wenige Pfähle erhalten. Dennoch ist der sakrale Charakter der Anlage gesichert. Ausser dem immer noch blühenden Pfirsichbaum ist es ein vor dem Langbau aufgestelltes Ensemble von mindestens 23 Terrakottafigurinen (s. Abb. 3.6/1), elf Veneres, zehn Matres, einem Jugendlichen in Kapuzenmantel und einem kindlichen Risus (Kap. 3.6; s. auch Kap. 2.6.3). In den Sedimenten der zweiten Überschwemmung, der diese Anlage um 225/230 n. Chr. zum Opfer gefallen war, fanden sich wiederum zahlreiche Keramikgefässe (Kap. 3.2.4) und zum Teil wertvolle Kleinfunde wie eine Glasperle mit Goldfolie (Kap. 3.8.2) und eine Fibel aus Silber (Kap. 3.3.3), die wohl ursprünglich im Langbau untergebracht waren (Kap. 5.3.2 mit Abb. 5/7). Weitere Funde mit sicherem oder möglichem sakralem Charakter finden sich unter den 1944/1945 geborgenen Funden (s. Abb. 5/8), etwa ein silberner Fingerring mit Merkurinschrift, ein silberner Lunula-Anhänger, eine silberne Kasserolle (Kap. 3.3.3), eine Glasflasche mit Schlangenfadenauflage (Kap. 3.8.2) und einige Bergkristalle (Kap. 3.8.4). Im Bereich der Terrakotten kamen ferner mehrere Münzen (Kap. 3.7) zum Vorschein, die vielleicht dort niedergelegt worden waren. Nach der zweiten Überschwemmung errichtete man um 231 n. Chr. am Bach eine Wassermühle (Horizont 2; Kap. 2.7; Beil. 8; Abb. 2.7/49). Ob das Heiligtum auf der Insel wieder aufgebaut oder aufgelassen wurde, muss mangels Hinweisen offen bleiben. Für den abgehobenen Zuflusskanal der Wassermühle verwendete man mehrere stehen gebliebene Pfähle der vorangegangenen Anlagen der Horizonte 1a und 1b. Obwohl die Wassermühle den 28 jährlichen Überschwemmungshorizonten (Kap. 2.2) und den Funden (Kap. 4.3.2; 4.4.4; 45) zufolge nur bis um 260 n. Chr., während gut einer Generation, bestand, musste sie mindestens zweimal erneuert werden – nachgewiesen sind drei Wasserräder, drei Mühlsteinpaare und vermutlich drei Podeste, auf denen jeweils das Mahlwerk ruhte. Grund für diese Umbauten war wohl der weiche, instabile Untergrund, der zu Verschiebungen geführt hatte, so dass das Zusammenspiel von Wellbaum bzw. Sternnabe und Übersetzungsrad nicht mehr funktionierte und das ganze System zerbrach. Die Analyse von Pollen aus dem Gehhorizont hat als Mahlgut Getreide vom Weizentyp nachgewiesen (Kap. 3.11.4). Das Abzeichen eines Benefiziariers (Kap. 3.3.2 mit Abb. 3.3/23,B71) könnte dafür sprechen, dass das verarbeitete Getreide zumindest zum Teil für das römische Militär bestimmt war (s. auch Kap. 6.2.3). Ein im Horizont 2 gefundener Schreibgriffel und weitere stili sowie eine Waage für das Wägen bis zu 35-40 kg schweren Waren aus dem Fundbestand von 1944/1945 könnten davon zeugen, dass das Getreide zu wägen und zu registrieren war (Kap. 3.4.2). Kurz nach 260 n. Chr. fiel die Wassermühle einem weiteren Hochwasser zum Opfer. Für den folgenden Horizont 3 (Beil. 9) brachte man einen Kiesboden ein und errichtete ein kleines Gebäude (Kap. 2.8). Hier war wohl wiederum eine Schmiede untergebracht, wie die zahlreichen Kalottenschlacken belegen (Kap. 3.9), die im Umfeld der kleinen Baus zum Vorschein kamen. Aufgrund der Funde (Kap. 4.4.4; 4.5) kann diese Werkstatt nur kurze Zeit bestanden haben, höchstens bis um 270 n. Chr., bevor sie einem weiteren Hochwasser zum Opfer fiel. Von der jüngsten Anlage, die wohl noch in römische Zeit datiert (Horizont 4; Beil. 10), war lediglich eine Konstruktion aus grossen Steinplatten zu fassen (Kap. 2.9.1). Wozu sie diente, muss offen bleiben. Auch der geringe Fundanfall spricht dafür, dass die Nutzung des Platzes, zumindest für die römische Zeit, allmählich ein Ende fand (Kap. 4.5). Zu den jüngsten Strukturen gehören mehrere Gruben (Kap. 2.9.2), die vielleicht der Lehmentnahme dienten. Mangels Funden bleibt ihre Datierung indes ungewiss. Insbesondere wissen wir nicht, ob sie noch in römische Zeit datieren oder jünger sind. Spätestens mit der fünften Überschwemmung, die zur endgültigen Verlandung führte und wohl schon in die frühe Neuzeit zu setzen ist, wurde der Platz aufgelassen und erst mit dem Bau der bestehenden Fensterfabrik Baumgartner wieder besetzt.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Princeton Ocean Model is used to study the circulation in the Gulf of Maine and its seasonal transition in response to wind, surface heat flux, river discharge, and the M-2 tide. The model has an orthogonal-curvature linear grid in the horizontal with variable spacing from 3 km nearshore to 7 km offshore and 19 levels in the vertical. It is initialized and forced at the open boundary with model results from the East Coast Forecast System. The first experiment is forced by monthly climatological wind and heat flux from the Comprehensive Ocean Atmosphere Data Set; discharges from the Saint John, Penobscot, Kennebec, and Merrimack Rivers are added in the second experiment; the semidiurnal lunar tide (M-2) is included as part of the open boundary forcing in the third experiment. It is found that the surface heat flux plays an important role in regulating the annual cycle of the circulation in the Gulf of Maine. The spinup of the cyclonic circulation between April and June is likely caused by the differential heating between the interior gulf and the exterior shelf/slope region. From June to December the cyclonic circulation continues to strengthen, but gradually shrinks in size. When winter cooling erodes the stratification, the cyclonic circulation penetrates deeper into the water column. The circulation quickly spins down from December to February as most of the energy is consumed by bottom friction. While inclusion of river discharge changes details of the circulation pattern, the annual evolution of the circulation is largely unaffected. On the other hand, inclusion of the tide results in not only the anticyclonic circulation on Georges Bank but also modifications to the seasonal circulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Princeton Ocean Model is used to study the circulation features in the Pearl River Estuary and their responses to tide, river discharge, wind, and heat flux in the winter dry and summer wet seasons. The model has an orthogonal curvilinear grid in the horizontal plane with variable spacing from 0.5 km in the estuary to 1 km on the shelf and 15 sigma levels in the vertical direction. The initial conditions and the subtidal open boundary forcing are obtained from an associated larger-scale model of the northern South China Sea. Buoyancy forcing uses the climatological monthly heat fluxes and river discharges, and both the climatological monthly wind and the realistic wind are used in the sensitivity experiments. The tidal forcing is represented by sinusoidal functions with the observed amplitudes and phases. In this paper, the simulated tide is first examined. The simulated seasonal distributions of the salinity, as well as the temporal variations of the salinity and velocity over a tidal cycle are described and then compared with the in situ survey data from July 1999 and January 2000. The model successfully reproduces the main hydrodynamic processes, such as the stratification, mixing, frontal dynamics, summer upwelling, two-layer gravitational circulation, etc., and the distributions of hydrodynamic parameters in the Pearl River Estuary and coastal waters for both the winter and the summer season.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present steady-state absorption and emission spectroscopy and femtosecond broadband photoluminescence up-conversion spectroscopy studies of the electronic relaxation of Os(dmbp)3 (Os1) and Os(bpy)2(dpp) (Os2) in ethanol, where dmbp is 4,4′-dimethyl-2,2′-biypridine, bpy is 2,2′-biypridine, and dpp is 2,3-dipyridyl pyrazine. In both cases, the steady-state phosphorescence is due to the lowest 3MLCT state, whose quantum yield we estimate to be ≤5.0 × 10–3. For Os1, the steady-state phosphorescence lifetime is 25 ns. In both complexes, the photoluminescence excitation spectra map the absorption spectrum, pointing to an excitation wavelength-independent quantum yield. The ultrafast studies revealed a short-lived (≤100 fs) fluorescence, which stems from the lowest singlet metal-to-ligand-charge-transfer (1MLCT) state and decays by intersystem crossing to the manifold of 3MLCT states. In addition, Os1 exhibits a 50 ps lived emission from an intermediate triplet state at an energy 2000 cm–1 above that of the long-lived (25 ns) phosphorescence. In Os2, the 1MLCT–3MLCT intersystem crossing is faster than that in Os1, and no emission from triplet states is observed other than the lowest one. These observations are attributed to a higher density of states or a smaller energy spacing between them compared with Os1. They highlight the importance of the energetics on the rate of intersystem crossing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND A precise detection of volume change allows for better estimating the biological behavior of the lung nodules. Postprocessing tools with automated detection, segmentation, and volumetric analysis of lung nodules may expedite radiological processes and give additional confidence to the radiologists. PURPOSE To compare two different postprocessing software algorithms (LMS Lung, Median Technologies; LungCARE®, Siemens) in CT volumetric measurement and to analyze the effect of soft (B30) and hard reconstruction filter (B70) on automated volume measurement. MATERIAL AND METHODS Between January 2010 and April 2010, 45 patients with a total of 113 pulmonary nodules were included. The CT exam was performed on a 64-row multidetector CT scanner (Somatom Sensation, Siemens, Erlangen, Germany) with the following parameters: collimation, 24x1.2 mm; pitch, 1.15; voltage, 120 kVp; reference tube current-time, 100 mAs. Automated volumetric measurement of each lung nodule was performed with the two different postprocessing algorithms based on two reconstruction filters (B30 and B70). The average relative volume measurement difference (VME%) and the limits of agreement between two methods were used for comparison. RESULTS At soft reconstruction filters the LMS system produced mean nodule volumes that were 34.1% (P < 0.0001) larger than those by LungCARE® system. The VME% was 42.2% with a limit of agreement between -53.9% and 138.4%.The volume measurement with soft filters (B30) was significantly larger than with hard filters (B70); 11.2% for LMS and 1.6% for LungCARE®, respectively (both with P < 0.05). LMS measured greater volumes with both filters, 13.6% for soft and 3.8% for hard filters, respectively (P < 0.01 and P > 0.05). CONCLUSION There is a substantial inter-software (LMS/LungCARE®) as well as intra-software variability (B30/B70) in lung nodule volume measurement; therefore, it is mandatory to use the same equipment with the same reconstruction filter for the follow-up of lung nodule volume.