937 resultados para INTERHAEMAL BARRIER
Resumo:
Purpose: To determine the feasibility of taking intra-ocular pressure (IOP) readings with Goldmann-type applanation tonometer probe covered with cling film to avoid transmission of Creutzfeldt-Jakob disease (CJD). Methods: Data were collected on two occasions from the right eyes of 30 healthy subjects using a Perkins applanation tonometer. On each occasion, a single tonometry measurement was made with and without cling film covering. Results: Cling film covering brought about a statistically significant IOP bias (-0.8 mmHg on first occasion and -1.17 mmHg on second occasion). The 95% limits of agreement, between readings made with and without cling film covering, were ±3.4 mmHg on first occasion; ±2.5 mmHg on second occasion. A statistically significant reduction of inter-sessional repeatability was observed for readings taken with cling film (±5.2 mmHg) compared to those made without (±3.9 mmHg). Conclusions: Even if the above findings are found to be acceptable, given the known intra-subject variations of this type of tonometry (±4 mmHg), ethical and legal considerations relating to the barrier properties of cling film are likely to prevent its routine use by optometrists. © 2004 The College of Optometrists.
Resumo:
Purpose: To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). Methods: The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Results: Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. Conclusions: The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another. © 2003 The College of Optometrists.
Resumo:
The thermal oxidation of two model compounds representing the aromatic polyamide, MXD6 (poly m-xylylene adipamide) have been investigated. The model compounds (having different chemical structures, viz, one corresponding to the aromatic part of the chain and the other to the aliphatic part), based on the structure of MXD6 were prepared and reactions with different concentrations of cobalt ions examined with the aim of identifying the role of the different structural components of MXD6 on the mechanism of oxidation. The study showed that cobalt, in the presence of sodium phosphite (which acts as an antioxidant for MXD6 and the model compounds), increases the oxidation of the model compounds. It is believed that the cobalt acts predominantly as a catalyst for the decomposition of hydroperoxides, formed during oxidation of the models in the melt phase, to free radical products and to a lesser extent as a catalyst for the initiation of the oxidation reaction by complex formation with the amide, which is more likely to take place in the solid phase. An oxidation cycle has been proposed consisting of two parts both of which will occur, to some extent under all conditions of oxidation (in the melt and in the solid phase), but their individual predominance must be determined by the prevailing oxygen pressure at the reaction site. The different aspects of this proposed mechanism were examined from extensive model compound studies, and the evidence based on the nature of product formation and the kinetics of these reactions. Main techniques used to compare the rates of oxidation and the study of kinetics included, oxygen absorption, FT-IR, UV and TGA. HPLC was used for product separation and identification.
Resumo:
The research is concerned with the terminological problems that computer users experience when they try to formulate their knowledge needs and attempt to access information contained in computer manuals or online help systems while building up their knowledge. This is the recognised but unresolved problem of communication between the specialist and the layman. The initial hypothesis was that computer users, through their knowledge of language, have some prior knowledge of the subdomain of computing they are trying to come to terms with, and that language can be a facilitating mechanism, or an obstacle, in the development of that knowledge. Related to this is the supposition that users have a conceptual apparatus based on both theoretical knowledge and experience of the world, and of several domains of special reference related to the environment in which they operate. The theoretical argument was developed by exploring the relationship between knowledge and language, and considering the efficacy of terms as agents of special subject knowledge representation. Having charted in a systematic way the territory of knowledge sources and types, we were able to establish that there are many aspects of knowledge which cannot be represented by terms. This submission is important, as it leads to the realisation that significant elements of knowledge are being disregarded in retrieval systems because they are normally expressed by language elements which do not enjoy the status of terms. Furthermore, we introduced the notion of `linguistic ease of retrieval' as a challenge to more conventional thinking which focuses on retrieval results.
Resumo:
The thesis begins with a conceptual model of the way that language diversity affects the strategies, organisation and subsidiary control policies of multinational companies. The model is based solely on the researcher'’ personal experience of working in a variety of international management roles, but in Chapter 2 a wide-ranging review of related academic literature finds evidence to support the key ideas. The model is developed as a series of propositions which are tested in a comparative case study, refined and then re-tested in a global survey of multinational subsidiaries. The principal findings of the empirical phases of the thesis endorse the main tenets of the model: - That language difference between parent and subsidiary will impair communication, create mistrust and impede relationship development. - That subsequently the feelings of uncertainty, suspicion and mistrust will influence the decisions taken by the parent company. - They will have heightened sensitivity to language issues and will implement policies to manage language differences. - They will adopt low-risk strategies in host countries where they are concerned about language difference. - They will use organisational and manpower strategies to minimise the consequences and risks of the communications problems with the subsidiary. - As a consequence the level of integration and knowledge flow between parent and subsidiary will be curtailed. - They will adopt styles of control that depend least on their ability to communicate with their subsidiary. Although there is adequate support for all of the above conclusions, on some key points the evidence of the Case Studies and Survey is contradictory. The thesis, therefore, closes with an agenda for further research that would address these inconsistencies.
Resumo:
Despite a significant expansion of the literature on conflicts and fragility of states, only a few systematic attempts have been made to link the theoretical literature on social conflicts to the available micro-level information about the people who are involved in these conflicts. We address this lacuna in the literature using a household-level data set from Kosovo. Our analysis suggests that it is individually rational for competing ethnic communities, Kosovar Albanians and Kosovar Serbs, to resist a quick agreement on a social contract to share the region's resources.
Resumo:
Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.