986 resultados para Hydraulic diffusivity
Resumo:
Understanding the factors controlling fine root respiration (FRR) at different temporal scales will help to improve our knowledge about the spatial and temporal variability of soil respiration (SR) and to improve future predictions of CO2 effluxes to the atmosphere. Here we present a comparative study of how FRR respond to variability in soil temperature and moisture in two widely spread species, Scots pines (Pinus sylvestris L.) and Holm-oaks (HO; Quercus ilex L.). Those two species show contrasting water use strategies during the extreme summer-drought conditions that characterize the Mediterranean climate. The study was carried out on a mixed Mediterranean forest where Scots pines affected by drought induced die-back are slowly being replaced by the more drought resistant HO. FRR was measured in spring and early fall 2013 in excised roots freshly removed from the soil and collected under HO and under Scots pines at three different health stages: dead (D), defoliated (DP) and non-defoliated (NDP). Variations in soil temperature, soil water content and daily mean assimilation per tree were also recorded to evaluate FRR sensibility to abiotic and biotic environmental variations. Our results show that values of FRR were substantially lower under HO (1.26 ± 0.16 microgram CO2 /groot·min) than under living pines (1.89 ± 0.19 microgram CO2 /groot·min) which disagrees with the similar rates of soil respiration previously observed under both canopies and suggest that FRR contribution to total SR varies under different tree species. The similarity of FRR rates under HO and DP furthermore confirms other previous studies suggesting a recent Holm-oak root colonization of the gaps under dead trees. A linear mixed effect model approach indicated that seasonal variations in FRR were best explained by soil temperature (p<0.05) while soil moisture was not exerting any direct control over FRR, despite the low soil moisture values during the summer sampling. Plant assimilation rates were positively related to FRR explaining part of the observed variability (p<0.01). However the positive relations of FRR with plant assimilation occurred mainly during spring, when both soil moisture and plant assimilation rates were higher. Our results finally suggest that plants might be able to maintain relatively high rates of FRR during the sub-optimal abiotic and biotic summer conditions probably thanks to their capacity to re-mobilize carbon reserves and their capacity to passively move water from moister layers to upper layers with lower water potentials (where the FR were collected) by hydraulic lift.
Resumo:
Last decade Brazilian rivers experimented progressive biofouling of Limnoperna fortunei communities and Cordylophora caspia hydroids. The microhabitat is so favorable that in around 1.5 years L. fortunei increased from 0.39 to nearby 149,000 units/m². Ten Portland cement mortar samples were produced with 1: 3.5: 0.4 dosages and installed for 1 year at Salto Caxias Brazilian Power Plant reservoir in 0.5 m and 1.0 m deep to investigate the biofouling influence on hydraulic civil structures. SEM, EDS, visual investigation and XRF results indicate none direct chemical interrelationships between L. fortunei and the mortar samples. However C. caspia diminished the mortar surface resistance and caused cement paste leaching.
Resumo:
Surface sediments from the River São Francisco were analyzed to investigate the impact, due to the presence of metals (Cd, Cu, Pb, Zn) in wastes from a metallurgical industry in the city of Três Marias/MG, Brazil. The concentrations and geochemical associations of Pb, Zn and trace metals associated with the minerals employed in zinc production were measured. Sediments close to discharge locations were highly contaminated with Pb (332-512 μg g-1) and Zn (7872-10780 μg g-1), with values decreasing rapidly due to dilution and hydraulic sorting. Evaluation of toxicity according to the Consensus-based Sediment Quality Guidelines indicated for Cd, Pb and Zn a high probability of adverse effects on aquatic biota at these sites.
Resumo:
The present research aimed to study the parameters that affect the determination of estrogens in sewage upon the use of SPE and determination by using gas chromatography mass spectrometry (GC/MS). The study evaluated the stabilization pond technology with regard to estrogens removal. The results showed that the methodology was able to identify and quantify the estrogens E1, E2, E2-17A and EE2 in sewage. Moreover, the estrogens sometimes were not removed in the stabilization pond, showing that even the high hydraulic retention time (HRT) and high sunlight intensity were not enough to degrade these compounds completely during load peaks.
Resumo:
Pesu on tärkeä osa sellun tuotantoprosessia. Eräs tapa toteuttaa sellun pesu on käyttää painediffusööriä. Painediffusööri toimii syrjäytyspesuperiaatteella, eli poistaa sellu-massasta keittolipeää paineistetun pesuveden avulla. Työssä on kehitetty painediffusöörin suunnittelun lähtökohtia keräämällä tietoa laitteen toiminnasta, rakenteesta, valmistuksesta sekä nykyisistä epäkohdista, joihin esitetään parannusmahdollisuuksia. Tärkeimmät kehitysalueet laitteessa ovat valmistus-toleranssien väljentäminen sekä sihdin pystysuuntaisen liikkeen tuottaminen. Laitteen valmistustoleranssit on analysoitu perusteellisesti, ja niiden väljentämis-mahdollisuuksia on tutkittu. Väljentämiseen ehdotetaan erilaisia keinoja. Sihdin liike tuotetaan tällä hetkellä hydrauliikalla. Hydrauliikkakomponenteille on koottu mitoitusohjeita, joiden jälkeen esitellään keinoja hydrauliikkajärjestelmän kehittämiseen. Lopuksi esitellään muita lineaarisen liikkeen tuottamisvaihtoehtoja, joilla hydrauliikan voisi korvata. Rakenteessa käytetyille valmistusmateriaaleille on etsitty olemassa olevat yleisimpien materiaalistandardien mukaiset nimikkeet materiaalinvalinnan helpottamiseksi jatkossa. Pääasiallisten valmistusmateriaalien lisäksi on kerätty tietoa myös vaihtoehtoisista konstruktiomateriaaleista sekä materiaalinvalinnasta ja tuotesuunnittelusta yleensä.
Resumo:
There are several filtration applications in the pulp and paper industry where the capacity and cost-effectiveness of processes are of importance. Ultrafiltration is used to clean process water. Ultrafiltration is a membrane process that separates a certain component or compound from a liquid stream. The pressure difference across the membrane sieves macromolecules smaller than 0.001-0.02 μm through the membrane. When optimizing the filtration process capacity, online information about the conditions of the membrane is needed. Fouling and compaction of the membrane both affect the capacity of the filtration process. In fouling a “cake” layer starts to build on the surface of the membrane. This layer blocks the molecules from sieving through the membrane thereby decreasing the yield of the process. In compaction of the membrane the structure is flattened out because of the high pressure applied. The higher pressure increases the capacity but may damage the structure of the membrane permanently. Information about the compaction is needed to effectively operate the filters. The objective of this study was to develop an accurate system for online monitoring of the condition of the membrane using ultrasound reflectometry. Measurements of ultrafiltration membrane compaction were made successfully utilizing ultrasound. The results were confirmed by permeate flux decline, measurements of compaction with a micrometer, mechanical compaction using a hydraulic piston and a scanning electron microscope (SEM). The scientific contribution of this thesis is to introduce a secondary ultrasound transducer to determine the speed of sound in the fluid used. The speed of sound is highly dependent on the temperature and pressure used in the filters. When the exact speed of sound is obtained by the reference transducer, the effect of temperature and pressure is eliminated. This speed is then used to calculate the distances with a higher accuracy. As the accuracy or the resolution of the ultrasound measurement is increased, the method can be applied to a higher amount of applications especially for processes where fouling layers are thinner because of smaller macromolecules. With the help of the transducer, membrane compaction of 13 μm was measured in the pressure of 5 bars. The results were verified with the permeate flux decline, which indicated that compaction had taken place. The measurements of compaction with a micrometer showed compaction of 23–26 μm. The results are in the same range and confirm the compaction. Mechanical compaction measurements were made using a hydraulic piston, and the result was the same 13 μm as obtained by applying the ultrasound time domain reflectometry (UTDR). A scanning electron microscope (SEM) was used to study the structure of the samples before and after the compaction.
Resumo:
APROS (Advanced Process Simulation Environment) is a computer simulation program developed to simulate thermal hydraulic processes in nuclear and conventional power plants. Earlier research at VTT Technological Research Centre of Finland had found the current version of APROS to produce inaccurate simulation results for a certain case of loop seal clearing. The objective of this Master’s thesis is to find and implement an alternative method for calculating the rate of stratification in APROS, which was found to be the reason for the inaccuracies. Brief literature study was performed and a promising candidate for the new method was found. The new method was implemented into APROS and tested against experiments and simulations from two test facilities and the current version of APROS. Simulation results with the new version were partially conflicting; in some cases the new method was more accurate than the current version, in some the current method was better. Overall, the new method can be assessed as an improvement.
Resumo:
The Switched Reluctance technology is probably best suited for industrial low-speed or zerospeed applications where the power can be small but the torque or the force in linear movement cases might be relatively high. Because of its simple structure the SR-motor is an interesting alternative for low power applications where pneumatic or hydraulic linear drives are to be avoided. This study analyses the basic parts of an LSR-motor which are the two mover poles and one stator pole and which form the “basic pole pair” in linear-movement transversal-flux switchedreluctance motors. The static properties of the basic pole pair are modelled and the basic design rules are derived. The models developed are validated with experiments. A one-sided one-polepair transversal-flux switched-reluctance-linear-motor prototype is demonstrated and its static properties are measured. The modelling of the static properties is performed with FEM-calculations. Two-dimensional models are accurate enough to model the static key features for the basic dimensioning of LSRmotors. Three-dimensional models must be used in order to get the most accurate calculation results of the static traction force production. The developed dimensioning and modelling methods, which could be systematically validated by laboratory measurements, are the most significant contributions of this thesis.
Resumo:
The objective of this dissertation is to improve the dynamic simulation of fluid power circuits. A fluid power circuit is a typical way to implement power transmission in mobile working machines, e.g. cranes, excavators etc. Dynamic simulation is an essential tool in developing controllability and energy-efficient solutions for mobile machines. Efficient dynamic simulation is the basic requirement for the real-time simulation. In the real-time simulation of fluid power circuits there exist numerical problems due to the software and methods used for modelling and integration. A simulation model of a fluid power circuit is typically created using differential and algebraic equations. Efficient numerical methods are required since differential equations must be solved in real time. Unfortunately, simulation software packages offer only a limited selection of numerical solvers. Numerical problems cause noise to the results, which in many cases leads the simulation run to fail. Mathematically the fluid power circuit models are stiff systems of ordinary differential equations. Numerical solution of the stiff systems can be improved by two alternative approaches. The first is to develop numerical solvers suitable for solving stiff systems. The second is to decrease the model stiffness itself by introducing models and algorithms that either decrease the highest eigenvalues or neglect them by introducing steady-state solutions of the stiff parts of the models. The thesis proposes novel methods using the latter approach. The study aims to develop practical methods usable in dynamic simulation of fluid power circuits using explicit fixed-step integration algorithms. In this thesis, twomechanisms whichmake the systemstiff are studied. These are the pressure drop approaching zero in the turbulent orifice model and the volume approaching zero in the equation of pressure build-up. These are the critical areas to which alternative methods for modelling and numerical simulation are proposed. Generally, in hydraulic power transmission systems the orifice flow is clearly in the turbulent area. The flow becomes laminar as the pressure drop over the orifice approaches zero only in rare situations. These are e.g. when a valve is closed, or an actuator is driven against an end stopper, or external force makes actuator to switch its direction during operation. This means that in terms of accuracy, the description of laminar flow is not necessary. But, unfortunately, when a purely turbulent description of the orifice is used, numerical problems occur when the pressure drop comes close to zero since the first derivative of flow with respect to the pressure drop approaches infinity when the pressure drop approaches zero. Furthermore, the second derivative becomes discontinuous, which causes numerical noise and an infinitely small integration step when a variable step integrator is used. A numerically efficient model for the orifice flow is proposed using a cubic spline function to describe the flow in the laminar and transition areas. Parameters for the cubic spline function are selected such that its first derivative is equal to the first derivative of the pure turbulent orifice flow model in the boundary condition. In the dynamic simulation of fluid power circuits, a tradeoff exists between accuracy and calculation speed. This investigation is made for the two-regime flow orifice model. Especially inside of many types of valves, as well as between them, there exist very small volumes. The integration of pressures in small fluid volumes causes numerical problems in fluid power circuit simulation. Particularly in realtime simulation, these numerical problems are a great weakness. The system stiffness approaches infinity as the fluid volume approaches zero. If fixed step explicit algorithms for solving ordinary differential equations (ODE) are used, the system stability would easily be lost when integrating pressures in small volumes. To solve the problem caused by small fluid volumes, a pseudo-dynamic solver is proposed. Instead of integration of the pressure in a small volume, the pressure is solved as a steady-state pressure created in a separate cascade loop by numerical integration. The hydraulic capacitance V/Be of the parts of the circuit whose pressures are solved by the pseudo-dynamic method should be orders of magnitude smaller than that of those partswhose pressures are integrated. The key advantage of this novel method is that the numerical problems caused by the small volumes are completely avoided. Also, the method is freely applicable regardless of the integration routine applied. The superiority of both above-mentioned methods is that they are suited for use together with the semi-empirical modelling method which necessarily does not require any geometrical data of the valves and actuators to be modelled. In this modelling method, most of the needed component information can be taken from the manufacturer’s nominal graphs. This thesis introduces the methods and shows several numerical examples to demonstrate how the proposed methods improve the dynamic simulation of various hydraulic circuits.
Resumo:
Työssä selvitettiin Neste Oil Porvoon jalostamon tuotantolinja 2 jäähdytysvesiverkon tilaa. Jäähdytysvesiverkon hydraulinen malli päivitettiin ja verifioitiin painemittauksin. Mallia tarkennettiin säätöventtiilien mallinnuksen sekä virhelähteiden tarkastelun perusteella havaituin muutoksin. Mallin verifioinnissa havaittiin huomattavia eroja mallin ja mitattujen paineiden välillä. Tämä johti mallin tarkempaan tarkasteluun, sekä virhelähteiden ja niiden vaikutusten selvittämiseen. Putkivarusteiden mallinnusmenetelmiä, sekä mallinnusperiaatteita vertailtiin keskenään. Koska jäähdytysveden kokonaiskierto oli riittämätön, tarkasteltiin kolmea vaihtoehtoa riittävän kiertovesimäärän aikaansaamiseksi. Nykyisten kiertovesipumppujen rinnanoperointi, sekä riittävän suureksi skaalatun pumpun käyttö simuloitiin. Kolmantena tapauksena arvioitiin lämmönvaihdinkohtaisen kuristussuunnitelman vaikutus putkiston painehäviöön, sekä putkistolle sopiva kiertovesipumppu. Vaihtoehdoille laskettiin suuntaa-antavat investointi- ja käyttökustannukset. Tarkastelun perusteella riittävän suureksi skaalattu pumppu todettiin kannattavimmaksi pienen hintaeron, sekä luotettavamman jäähdytysvesikierron käyttövarmuuden vuoksi. Työssä onnistuttiin tuottamaan yleispätevää tietoa suljetun jäähdytysvesiverkon hydrauliseen mallinnukseen vaikuttavista tekijöistä, sekä niiden vaikutuksesta mallin tarkkuuteen. Selvityksen perusteella tarkasteltua mallia saatiin tarkemmaksi.
Resumo:
The objective of this study was to evaluate the quality and the production of biogas and biofertilizer obtained from biodigester supplied with pig feces in the initial, growing and finishing stages, fed with diets formulated based on corn or sorghum. Twenty bench biodigesters were used with hydraulic retention time of 30 days and daily loads that contained 4 to 6% of total solids (TS) and 3.6 to 5.2% of volatile solids (VS). In the effluent of the biodigesters, mean levels of TS were observed ranging between 1.6 and 2.0% and of VS between 1.2 and 1.6%. The mean reductions of TS were 57.7 to 64.7% and of VS from 61.7 to 69.0%, and there was only difference in the finishing phase, in which the major averages reductions were produced by the biodigesters supplied with feces from animals fed with diets based on corn. In biodigesters supplied with feces from animals in the initial and growing stages fed with diets based on corn, were observed higher average productions of biogas and the greatest average potentials of biogas production. The average potentials obtained were 0.033; 0.181; 0.685; 0.788 and 1.132 m³ per kg of affluent, manure, TS added, VS added and VS reduced, respectively. No differences were found on the average content of methane in the biogas between diets and stages. The average concentrations of nutrients N, P, K, Ca, Mg, Na, Fe, Mn, Zn and Cu in the biodigester affluent and effluent, ranged between diets and stages.
Resumo:
The purpose of this study was to evaluate the uniformity of distribution coefficient (UDC) and coefficient of variation (CV) of a familiar set of irrigation, classifying it the ASAE standard. The irrigation and fertigation are determined by two methods the KELLER & KARMELI and DENÍCULI . The two experiments were subjected to varying pressures: 12, 14, 16 and 18 kPa, in a completely randomized design of twenty samples composed of flows with three replications. Urea, potassium chloride (KCl) and ammonium phosphate (MAP) were the elements used for fertigation. The system consisted of a 200 L tank, which supplied another container of 30 L, it was moved vertically to control the pressure. The data was statistically compared between treatments for each methodology. In fertigation the best pressure was 16 kPa and was classified as "excellent" for UDC (91.03%) and "marginal" for C.V. (7.47%). For the irrigation treatment, the best pressure was 16 kPa rated "excellent" for UDC (91.2%) and "marginal" for C.V. (7.68%). The DENÍCULI et al. (1980) methodology proved more reliable for the evaluation of drip systems. It was observed that this set has good uniformity of distribution, but with great variability in flows.
Resumo:
The study aimed to evaluate chemical, microbiological and hydro-physical changes of a Dystrophic Yellow Latosol, receiver of different levels of manipueira (cassava wastewater) application, in the cultivation of 'Terra Maranhão' banana. The experimental design was a randomized block with three replications in a factorial scheme 3 x 4, in which it was considered three soil depths and four levels of manipueira. It was evaluated the weighted mean diameter of the aggregate, the percentage of aggregation at different periods, soil density, particle density, porosity and soil saturated hydraulic conductivity, in addition to pH of P (mg dm -3), K (mg dm-3), Ca (cmolc dm-3), Mg (cmolc dm-3), Ca+Mg (cmolc dm-3), Al (cmolc dm-3), Na (cmolc dm -3), H+Al (cmolc dm-3), CEC (cmolc dm-3), V%, OM (g kg-1), soil microbial biomass (Ug Cg-1 dry soil), acid phosphatase (Ug PNP g-1 h-1). The use of manipueira influenced some physical characteristic of the soil, but it was not possible to specify the effect of increasing application dosage. Therefore, the application did not affect the biological indicators assessed in the soil or its pH. The use of manipueira as a fertilizer in the doses used in this study showed low increase of K, P, H+Al and Al in the soil and a good increase of Mg, Ca and Ca+Mg, Na, CEC and V%.
Resumo:
In this study is presented an economic optimization method to design telescope irrigation laterals (multidiameter) with regular spaced outlets. The proposed analytical hydraulic solution was validated by means of a pipeline composed of three different diameters. The minimum acquisition cost of the telescope pipeline was determined by an ideal arrangement of lengths and respective diameters for each one of the three segments. The mathematical optimization method based on the Lagrange multipliers provides a strategy for finding the maximum or minimum of a function subject to certain constraints. In this case, the objective function describes the acquisition cost of pipes, and the constraints are determined from hydraulic parameters as length of irrigation laterals and total head loss permitted. The developed analytical solution provides the ideal combination of each pipe segment length and respective diameter, resulting in a decreased of the acquisition cost.
Resumo:
The energy balance for the production of sunflower oil and cake was carried out during the agricultural and industrial stage phase, where it was considered a cold extraction by hydraulic pressing, with the plant location in a rural area with a radius of 30km range. Data on productivity was used in two varieties of sunflower (Helio 358 and Aguará 04) grown in different seasons (2007/2008, 2008/2009), under different irrigation levels. Data showed that irrigation resulted in an increase in productivity of both varieties, and the best response was observed for Aguará 04 variety. Moreover, the increased intensity of irrigation negatively affected the energy balance, reducing the ratio between energy produced and energy used in the production chain. The most significant inputs in the energy intake were fertilizer followed by diesel oil, when irrigation was not used for. When the irrigation technique was used, the most significant inputs, in order of representativeness, were: energy, fertilizer and equipment.