983 resultados para High angular resolution diffusion imaging (HARDI)
Resumo:
Mapping the human auditory cortex with standard functional imaging techniques is difficult because of its small size and angular position along the Sylvian fissure. As a result, the exact number and location of auditory cortex areas in the human remains unknown. In a first experiment, we measured the two largest tonotopic areas of primary auditory cortex (PAC, Al and R) using high-resolution functional MRI at 7 Tesla relative to the underlying anatomy of Heschl's gyrus (HG). The data reveals a clear anatomical- functional relationship that indicates the location of PAC across the range of common morphological variants of HG (single gyri, partial duplication and complete duplication). Human PAC tonotopic areas are oriented along an oblique posterior-to-anterior axis with mirror-symmetric frequency gradients perpendicular to HG, as in the macaque. In a second experiment, we tested whether these primary frequency-tuned units were modulated by selective attention to preferred vs. non-preferred sound frequencies in the dynamic manner needed to account for human listening abilities in noisy environments, such as cocktail parties or busy streets. We used a dual-stream selective attention experiment where subjects attended to one of two competing tonal streams presented simultaneously to different ears. Attention to low-frequency tones (250 Hz) enhanced neural responses within low-frequency-tuned voxels relative to high (4000 Hz), and vice versa when at-tention switched from high to low. Human PAC is able to tune into attended frequency channels and can switch frequencies on demand, like a radio. In a third experiment, we investigated repetition suppression effects to environmental sounds within primary and non-primary early-stage auditory areas, identified with the tonotopic mapping design. Repeated presentations of sounds from the same sources, as compared to different sources, gave repetition suppression effects within posterior and medial non-primary areas of the right hemisphere, reflecting their potential involvement in semantic representations. These three studies were conducted at 7 Tesla with high-resolution imaging. However, 7 Tesla scanners are, for the moment, not yet used for clinical diagnosis and mostly reside in institutions external to hospitals. Thus, hospital-based clinical functional and structural studies are mainly performed using lower field systems (1.5 or 3 Tesla). In a fourth experiment, we acquired tonotopic maps at 3 and 7 Tesla and evaluated the consistency of a tonotopic mapping paradigm between scanners. Mirror-symmetric gradients within PAC were highly similar at 7 and 3 Tesla across renderings at different spatial resolutions. We concluded that the tonotopic mapping paradigm is robust and suitable for definition of primary tonotopic areas, also at 3 Tesla. Finally, in a fifth study, we considered whether focal brain lesions alter tonotopic representations in the intact ipsi- and contralesional primary auditory cortex in three patients with hemispheric or cerebellar lesions, without and with auditory complaints. We found evidence for tonotopic reorganisation at the level of the primary auditory cortex in cases of brain lesions independently of auditory complaints. Overall, these results reflect a certain degree of plasticity within primary auditory cortex in different populations of subjects, assessed at different field strengths. - La cartographie du cortex auditif chez l'humain est difficile à réaliser avec des techniques d'imagerie fonctionnelle standard, étant donné sa petite taille et position angulaire le long de la fissure sylvienne. En conséquence, le nombre et l'emplacement exacts des différentes aires du cortex auditif restent inconnus chez l'homme. Lors d'une première expérience, nous avons mesuré, avec de l'imagerie par résonance magnétique à haute intensité (IRMf à 7 Tesla) chez des sujets humains sains, deux larges aires au sein du cortex auditif primaire (PAC; Al et R) avec une représentation spécifique des fréquences pures préférées - ou tonotopie. Nos résultats ont démontré une relation anatomico- fonctionnelle qui définit clairement la position du PAC à travers toutes les variantes du gyrus d'Heschl's (HG). Les aires tonotopiques du PAC humain sont orientées le long d'un axe postéro-antérieur oblique avec des gradients de fréquences spécifiques perpendiculaires à HG, d'une manière similaire à celles mesurées chez le singe. Dans une deuxième expérience, nous avons testé si ces aires primaires pouvaient être modulées, de façon dynamique, par une attention sélective pour des fréquences préférées par rapport à celles non-préférées. Cette modulation est primordiale lors d'interactions sociales chez l'humain en présence de bruits distracteurs tels que d'autres discussions ou un environnement sonore nuisible (comme par exemple, dans la circulation routière). Dans cette étude, nous avons utilisé une expérience d'attention sélective où le sujet devait être attentif à une des deux voies sonores présentées simultanément à chaque oreille. Lorsque le sujet portait était attentif aux sons de basses fréquences (250 Hz), la réponse neuronale relative à ces fréquences augmentait par rapport à celle des hautes fréquences (4000 Hz), et vice versa lorsque l'attention passait des hautes aux basses fréquences. De ce fait, nous pouvons dire que PAC est capable de focaliser sur la fréquence attendue et de changer de canal selon la demande, comme une radio. Lors d'une troisième expérience, nous avons étudié les effets de suppression due à la répétition de sons environnementaux dans les aires auditives primaires et non-primaires, d'abord identifiées via le protocole de la première étude. La présentation répétée de sons provenant de la même source sonore, par rapport à de sons de différentes sources sonores, a induit un effet de suppression dans les aires postérieures et médiales auditives non-primaires de l'hémisphère droite, reflétant une implication de ces aires dans la représentation de la catégorie sémantique. Ces trois études ont été réalisées avec de l'imagerie à haute résolution à 7 Tesla. Cependant, les scanners 7 Tesla ne sont pour le moment utilisés que pour de la recherche fondamentale, principalement dans des institutions externes, parfois proches du patient mais pas directement à son chevet. L'imagerie fonctionnelle et structurelle clinique se fait actuellement principalement avec des infrastructures cliniques à 1.5 ou 3 Tesla. Dans le cadre dune quatrième expérience, nous avons avons évalués la cohérence du paradigme de cartographie tonotopique à travers différents scanners (3 et 7 Tesla) chez les mêmes sujets. Nos résultats démontrent des gradients de fréquences définissant PAC très similaires à 3 et 7 Tesla. De ce fait, notre paradigme de définition des aires primaires auditives est robuste et applicable cliniquement. Finalement, nous avons évalués l'impact de lésions focales sur les représentations tonotopiques des aires auditives primaires des hémisphères intactes contralésionales et ipsilésionales chez trois patients avec des lésions hémisphériques ou cérébélleuses avec ou sans plaintes auditives. Nous avons trouvé l'évidence d'une certaine réorganisation des représentations topographiques au niveau de PAC dans le cas de lésions cérébrales indépendamment des plaintes auditives. En conclusion, nos résultats démontrent une certaine plasticité du cortex auditif primaire avec différentes populations de sujets et différents champs magnétiques.
Resumo:
PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.
Resumo:
Background: The glycosylated hemoglobin (HbA1c) is used to help monitor the degree of a diabetic’s hyperglycemia. Security and accuracy of the methods used in its detection are affected by variants forms of Hb or elevations in levels of Fetal Hb (HbF). These interference are the result of a change in the haemoglobin total net charge of the variant due of a substitution of one amino acid in the remaining amino terminal of the beta chain. International Standardization for HbA1c values (NGSP) not include interference assessment as part of the certification program. Therefore, the effect of each variant or the lifting of the HbF on HbA1c result should be examined in each sample depending on the detected variant and the method used for the detection of the same. The objectives were: to describe the possible variants of Hb and their interference in HbA1c measurement by our method, after the implementation of a computer program for their detection. To identify some variants detected by chromatography liquid ion exchange high resolution (HPLC) with DNA molecular sequencing.
Resumo:
MRI tractography is the mapping of neural fiber pathways based on diffusion MRI of tissue diffusion anisotropy. Tractography based on diffusion tensor imaging (DTI) cannot directly image multiple fiber orientations within a single voxel. To address this limitation, diffusion spectrum MRI (DSI) and related methods were developed to image complex distributions of intravoxel fiber orientation. Here we demonstrate that tractography based on DSI has the capacity to image crossing fibers in neural tissue. DSI was performed in formalin-fixed brains of adult macaque and in the brains of healthy human subjects. Fiber tract solutions were constructed by a streamline procedure, following directions of maximum diffusion at every point, and analyzed in an interactive visualization environment (TrackVis). We report that DSI tractography accurately shows the known anatomic fiber crossings in optic chiasm, centrum semiovale, and brainstem; fiber intersections in gray matter, including cerebellar folia and the caudate nucleus; and radial fiber architecture in cerebral cortex. In contrast, none of these examples of fiber crossing and complex structure was identified by DTI analysis of the same data sets. These findings indicate that DSI tractography is able to image crossing fibers in neural tissue, an essential step toward non-invasive imaging of connectional neuroanatomy.
Resumo:
The tonotopic representations within the primary auditory cortex (PAC) have been successfully mapped with ultra-high field fMRI. Here, we compared the reliability of this tonotopic mapping paradigm at 7 T with 1.5 mm spatial resolution with maps acquired at 3 T with the same stimulation paradigm, but with spatial resolutions of 1.8 and 2.4 mm. For all subjects, the mirror-symmetric gradients within PAC were highly similar at 7 T and 3 T and across renderings at different spatial resolutions; albeit with lower percent signal changes at 3 T. In contrast, the frequency maps outside PAC tended to suffer from a reduced BOLD contrast-to-noise ratio at 3 T for a 1.8 mm voxel size, while robust at 2.4 mm and at 1.5 mm at 7 T. Overall, our results showed the robustness of the phase-encoding paradigm used here to map tonotopic representations across scanners.
Resumo:
PURPOSE: To compare the apparent diffusion coefficient (ADC) values of malignant liver lesions on diffusion-weighted MRI (DWI) before and after successful radiofrequency ablation (RF ablation). MATERIALS AND METHODS: Thirty-two patients with 43 malignant liver lesions (23/20: metastases/hepatocellular carcinomas (HCC)) underwent liver MRI (3.0T) before (<1month) and after RF ablation (at 1, 3 and 6months) using T2-, gadolinium-enhanced T1- and DWI-weighted MR sequences. Jointly, two radiologists prospectively measured ADCs for each lesion by means of two different regions of interest (ROIs), first including the whole lesion and secondly the area with the visibly most restricted diffusion (MRDA) on ADC map. Changes of ADCs were evaluated with ANOVA and Dunnett tests. RESULTS: Thirty-one patients were successfully treated, while one patient was excluded due to focal recurrence. In metastases (n=22), the ADC in the whole lesion and in MRDA showed an up-and-down evolution. In HCC (n=20), the evolution of ADC was more complex, but with significantly higher values (p=0.013) at 1 and 6months after RF ablation. CONCLUSION: The ADC values of malignant liver lesions successfully treated by RF ablation show a predictable evolution and may help radiologists to monitor tumor response after treatment.
Resumo:
An efficient high-resolution (HR) three-dimensional (3D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, the offshore extension of a complex fault zone well mapped on land was chosen for testing our system. A preliminary two-dimensional seismic survey indicated structures that include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie south-east-dipping Tertiary Molasse beds and a major fault zone (Paudeze Fault Zone) that separates Plateau and Subalpine Molasse (SM) units. A 3D survey was conducted over this test site using a newly developed three-streamer system. It provided high-quality data with a penetration to depths of 300 m below the water bottom of non-aliased signal for dips up to 30degrees and with a maximum vertical resolution of 1.1 m. The data were subjected to a conventional 3D processing sequence that included post-stack time migration. Tests with 3D pre-stack depth migration showed that such techniques can be applied to HR seismic surveys. Delineation of several horizons and fault surfaces reveals the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3D geometries can be distinguished. Three fault surfaces and the top of a molasse surface were mapped in 3D. Analysis of the geometry of these surfaces and their relative orientation suggests that pre-existing structures within the Plateau Molasse (PM) unit influenced later faulting between the Plateau and SM. In particular, a change in strike of the PM bed dip may indicate a fold formed by a regional stress regime, the orientation of which was different from the one responsible for the creation of the Paudeze Fault Zone. This structure might have later influenced the local stress regime and caused the curved shape of the Paudeze Fault in our surveyed area.
Resumo:
The sparsely spaced highly permeable fractures of the granitic rock aquifer at Stang-er-Brune (Brittany, France) form a well-connected fracture network of high permeability but unknown geometry. Previous work based on optical and acoustic logging together with single-hole and cross-hole flowmeter data acquired in 3 neighbouring boreholes (70-100 m deep) has identified the most important permeable fractures crossing the boreholes and their hydraulic connections. To constrain possible flow paths by estimating the geometries of known and previously unknown fractures, we have acquired, processed and interpreted multifold, single- and cross-hole GPR data using 100 and 250 MHz antennas. The GPR data processing scheme consisting of timezero corrections, scaling, bandpass filtering and F-X deconvolution, eigenvector filtering, muting, pre-stack Kirchhoff depth migration and stacking was used to differentiate fluid-filled fracture reflections from source generated noise. The final stacked and pre-stack depth-migrated GPR sections provide high-resolution images of individual fractures (dipping 30-90°) in the surroundings (2-20 m for the 100 MHz antennas; 2-12 m for the 250 MHz antennas) of each borehole in a 2D plane projection that are of superior quality to those obtained from single-offset sections. Most fractures previously identified from hydraulic testing can be correlated to reflections in the single-hole data. Several previously unknown major near vertical fractures have also been identified away from the boreholes.
Resumo:
Exploring the anatomical and functional connectivities between different regions of the brain (the "Connectome") is a core challenge in neuroscience. While robust methods are available for the adult brain, mapping the connectome in neonates is highly challenging. The purpose of this pilot study is to present a methodological approach for analyzing structural connectivity of a neonate brain and to exploit the MP2RAGE sequence with its advantageous contrast properties
Resumo:
MR connectomics is an emerging framework in neuro-science that combines diffusion MRI and whole brain tractography methodologies with the analytical tools of network science. In the present work we review the current methods enabling structural connectivity mapping with MRI and show how such data can be used to infer new information of both brain structure and function. We also list the technical challenges that should be addressed in the future to achieve high-resolution maps of structural connectivity. From the resulting tremendous amount of data that is going to be accumulated soon, we discuss what new challenges must be tackled in terms of methods for advanced network analysis and visualization, as well data organization and distribution. This new framework is well suited to investigate key questions on brain complexity and we try to foresee what fields will most benefit from these approaches.
Resumo:
To perform a climatic analysis of the annual UV index (UVI) variations in Catalonia, Spain (northeast of the Iberian Peninsula), a new simple parameterization scheme is presented based on a multilayer radiative transfer model. The parameterization performs fast UVI calculations for a wide range of cloudless and snow-free situations and can be applied anywhere. The following parameters are considered: solar zenith angle, total ozone column, altitude, aerosol optical depth, and single-scattering albedo. A sensitivity analysis is presented to justify this choice with special attention to aerosol information. Comparisons with the base model show good agreement, most of all for the most common cases, giving an absolute error within 0.2 in the UVI for a wide range of cases considered. Two tests are done to show the performance of the parameterization against UVI measurements. One uses data from a high-quality spectroradiometer from Lauder, New Zealand [45.04°S, 169.684°E, 370 m above mean sea level (MSL)], where there is a low presence of aerosols. The other uses data from a Robertson–Berger-type meter from Girona, Spain (41.97°N, 2.82°E, 100 m MSL), where there is more aerosol load and where it has been possible to study the effect of aerosol information on the model versus measurement comparison. The parameterization is applied to a climatic analysis of the annual UVI variation in Catalonia, showing the contributions of solar zenith angle, ozone, and aerosols. High-resolution seasonal maps of typical UV index values in Catalonia are presented
Resumo:
In this study we investigated the effect of medial temporal lobe epilepsy (MTLE) on the global characteristics of brain connectivity estimated by topological measures. We used DSI (Diffusion Spectrum Imaging) to construct a connectivity matrix where the nodes represents the anatomical ROIs and the edges are the connections between any pair of ROIs weighted by the mean GFA/FA values. A significant difference was found between the patient group vs control group in characteristic path length, clustering coefficient and small-worldness. This suggests that the MTLE network is less efficient compared to the network of the control group.