849 resultados para Generators


Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]This article presents the results obtained in the analysis of irregular microstrip structures using a full wave method of moments scheme. The irregular microstrip structures are divided into rectangular subdomains. The EFIE is discretized an solved over the subdomains using a Galerkin type scheme. Base and weight functions are piece wise sinusoidals (PWS) or triangular. Delta gap voltage generators are used as sources]. Green functions are computed using a freely available library developed by our research group. All the calculations are carried out in the so called ”spatial domain” so there is no need of using regular grids during the discretization process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the objective to improve the reactor physics calculation on a 2D and 3D nuclear reactor via the Diffusion Equation, an adaptive automatic finite element remeshing method, based on the elementary area (2D) or volume (3D) constraints, has been developed. The adaptive remeshing technique, guided by a posteriori error estimator, makes use of two external mesh generator programs: Triangle and TetGen. The use of these free external finite element mesh generators and an adaptive remeshing technique based on the current field continuity show that they are powerful tools to improve the neutron flux distribution calculation and by consequence the power solution of the reactor core even though they have a minor influence on the critical coefficient of the calculated reactor core examples. Two numerical examples are presented: the 2D IAEA reactor core numerical benchmark and the 3D model of the Argonauta research reactor, built in Brasil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dado el impacto negativo asociado a la ocurrencia de fallas en tubos de generadores de vapor (TGVs) en centrales nucleares, el estudio de la integridad estructural de éstos ha comenzado a recibir mayor atención recientemente. Diversas metodologías basadas en análisis de carga límite han sido propuestas para asegurar la integridad estructural de los tubos, según los requerimientos establecidos por las autoridades regulatorias. Éstas han conducido, sin embargo, a la definición de criterios de reparación o taponado de TGVs excesivamente conservativos. Por lo tanto, con el objetivo de reducir la cantidad de tubos innecesariamente removidos de servicio, nuevos criterios de evaluación de integridad han sido propuestos recientemente en la literatura. En este contexto, la mecánica de fractura elastoplástica se presenta como una alternativa para la evaluación de la integridad de TGVs, requiriéndose dos elementos para su aplicación: la estimación de la fuerza impulsora en términos del parámetro elastoplástico (por ejemplo, la integral J) y la medición experimental de la tenacidad a la fractura del material de los tubos (por ejemplo, a través de la curva de resistencia J-R). Este trabajo presenta el desarrollo de técnicas experimentales no normalizadas para la determinación de curvas J-R para TGVs con fisuras pasantes circunferenciales y longitudinales. Debido a las dimensiones reducidas de los TGVs, diferentes probetas no normalizadas fueron propuestas. Además, en los ensayos se utilizaron condiciones de carga de tracción y flexión con el objetivo de modelar más adecuadamente los estados tensionales y las condiciones de constraint reales en TGVs. Los valores de la integral J fueron estimados utilizando el método del factor η. La aptitud del método fue evaluada a partir de simulaciones numéricas de los ensayos propuestos mediante análisis elastoplásticos con la técnica de elementos finitos. Se encontró que condiciones de mayor constraint asociadas con fisuras profundas y cargas de flexión favorecen la validez del método del factor η, mientras que configuraciones de menor constraint dan como resultado factores η que exhiben una mayor dependencia con el nivel de carga aplicada. También se observó que los factores η basados en la apertura de la boca de la fisura (Crack Mouth Opening Displacement o CMOD) presentan una dependencia mucho menor con el nivel de carga respecto a los factores η definidos a partir del desplazamiento del punto de aplicación de la carga (Load Line Displacement o LLD). Se presentan los valores del factor η para las probetas estudiadas con fisuras profundas (a/W ≥ 0,40). Se realizaron ensayos de fractura a temperatura ambiente y 300 °C con probetas obtenidas de TGVs nucleares fabricados a partir de las aleaciones 690 (Ni: 61; Cr: 29; Fe: 8,95, % en peso) y 800 (Ni: 33; Cr: 21,6; Fe: 42,2, % en peso). Durante los ensayos de fractura a temperatura ambiente, la extensión estable de fisura fue medida mediante una técnica óptica utilizando un microscopio digital. Para estos ensayos también se aplicó el método de normalización que propone la norma ASTM E1820-15 en el Anexo 15, encontrándose una buena coincidencia entre las longitudes estimadas por éste y las medidas ópticamente. De esta manera, el método de normalización fue utilizado para los ensayos a alta temperatura. Los resultados experimentales mostraron que ambos materiales tienen elevadas tenacidades a la fractura, siendo la aleación 800 la que presentó curvas J-R más elevadas que la aleación 690 tanto para fisuras circunferenciales como longitudinales. Las curvas J-R para ambas aleaciones mostraron un efecto marcado con la orientación de la fisura, es decir que existe una importante anisotropía en las propiedades de fractura: las fisuras circunferenciales presentaron curvas J-R más elevadas que las fisuras longitudinales. El nivel de constraint desarrollado en los ensayos, dado por las condiciones de carga de tracción y flexión, evidenció poco efecto sobre las curvas J-R para probetas con fisuras profundas (a/W ~ 0,50). A su vez, la temperatura de ensayo (temperatura ambiente y 300 °C) presentó un efecto prácticamente nulo para ambas aleaciones. Usando las propiedades de fractura obtenidas en este trabajo, la metodología FAD (Failure Assessment Diagram) fue propuesta y utilizada para la predicción de las condiciones de falla de TGVs fisurados para diferentes geometrías de fisura y condiciones de carga. La comparación entre análisis teóricos y datos experimentales muestra la potencialidad del FAD como una metodología capaz de predecir adecuadamente las fallas de estos componentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dado el impacto negativo asociado a la ocurrencia de fallas en tubos de generadores de vapor (TGVs) en centrales nucleares, el estudio de la integridad estructural de éstos ha comenzado a recibir mayor atención recientemente. Diversas metodologías basadas en análisis de carga límite han sido propuestas para asegurar la integridad estructural de los tubos, según los requerimientos establecidos por las autoridades regulatorias. Éstas han conducido, sin embargo, a la definición de criterios de reparación o taponado de TGVs excesivamente conservativos. Por lo tanto, con el objetivo de reducir la cantidad de tubos innecesariamente removidos de servicio, nuevos criterios de evaluación de integridad han sido propuestos recientemente en la literatura. En este contexto, la mecánica de fractura elastoplástica se presenta como una alternativa para la evaluación de la integridad de TGVs, requiriéndose dos elementos para su aplicación: la estimación de la fuerza impulsora en términos del parámetro elastoplástico (por ejemplo, la integral J) y la medición experimental de la tenacidad a la fractura del material de los tubos (por ejemplo, a través de la curva de resistencia J-R). Este trabajo presenta el desarrollo de técnicas experimentales no normalizadas para la determinación de curvas J-R para TGVs con fisuras pasantes circunferenciales y longitudinales. Debido a las dimensiones reducidas de los TGVs, diferentes probetas no normalizadas fueron propuestas. Además, en los ensayos se utilizaron condiciones de carga de tracción y flexión con el objetivo de modelar más adecuadamente los estados tensionales y las condiciones de constraint reales en TGVs. Los valores de la integral J fueron estimados utilizando el método del factor η. La aptitud del método fue evaluada a partir de simulaciones numéricas de los ensayos propuestos mediante análisis elastoplásticos con la técnica de elementos finitos. Se encontró que condiciones de mayor constraint asociadas con fisuras profundas y cargas de flexión favorecen la validez del método del factor η, mientras que configuraciones de menor constraint dan como resultado factores η que exhiben una mayor dependencia con el nivel de carga aplicada. También se observó que los factores η basados en la apertura de la boca de la fisura (Crack Mouth Opening Displacement o CMOD) presentan una dependencia mucho menor con el nivel de carga respecto a los factores η definidos a partir del desplazamiento del punto de aplicación de la carga (Load Line Displacement o LLD). Se presentan los valores del factor η para las probetas estudiadas con fisuras profundas (a/W ≥ 0,40). Se realizaron ensayos de fractura a temperatura ambiente y 300 °C con probetas obtenidas de TGVs nucleares fabricados a partir de las aleaciones 690 (Ni: 61; Cr: 29; Fe: 8,95, % en peso) y 800 (Ni: 33; Cr: 21,6; Fe: 42,2, % en peso). Durante los ensayos de fractura a temperatura ambiente, la extensión estable de fisura fue medida mediante una técnica óptica utilizando un microscopio digital. Para estos ensayos también se aplicó el método de normalización que propone la norma ASTM E1820-15 en el Anexo 15, encontrándose una buena coincidencia entre las longitudes estimadas por éste y las medidas ópticamente. De esta manera, el método de normalización fue utilizado para los ensayos a alta temperatura. Los resultados experimentales mostraron que ambos materiales tienen elevadas tenacidades a la fractura, siendo la aleación 800 la que presentó curvas J-R más elevadas que la aleación 690 tanto para fisuras circunferenciales como longitudinales. Las curvas J-R para ambas aleaciones mostraron un efecto marcado con la orientación de la fisura, es decir que existe una importante anisotropía en las propiedades de fractura: las fisuras circunferenciales presentaron curvas J-R más elevadas que las fisuras longitudinales. El nivel de constraint desarrollado en los ensayos, dado por las condiciones de carga de tracción y flexión, evidenció poco efecto sobre las curvas J-R para probetas con fisuras profundas (a/W ~ 0,50). A su vez, la temperatura de ensayo (temperatura ambiente y 300 °C) presentó un efecto prácticamente nulo para ambas aleaciones. Usando las propiedades de fractura obtenidas en este trabajo, la metodología FAD (Failure Assessment Diagram) fue propuesta y utilizada para la predicción de las condiciones de falla de TGVs fisurados para diferentes geometrías de fisura y condiciones de carga. La comparación entre análisis teóricos y datos experimentales muestra la potencialidad del FAD como una metodología capaz de predecir adecuadamente las fallas de estos componentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To understand the evolution of bipedalism among the homnoids in an ecological context we need to be able to estimate theenerrgetic cost of locomotion in fossil forms. Ideally such an estimate would be based entirely on morphology since, except for the rare instances where footprints are preserved, this is hte only primary source of evidence available. In this paper we use evolutionary robotics techniques (genetic algoritms, pattern generators and mechanical modeling) to produce a biomimentic simulation of bipedalism based on human body dimensions. The mechnaical simulation is a seven-segment, two-dimensional model with motive force provided by tension generators representing the major muscle groups acting around the lower-limb joints. Metabolic energy costs are calculated from the muscel model, and bipedal gait is generated using a finite-state pattern generator whose parameters are produced using a genetic algorithm with locomotor economy (maximum distance for a fixed energy cost) as the fitness criterion. The model is validated by comparing the values it generates with those for modern humans. The result (maximum efficiency of 200 J m-1) is within 15% of the experimentally derived value, which is very encouraging and suggests that this is a useful analytic technique for investigating the locomotor behaviour of fossil forms. Initial work suggests that in the future this technique could be used to estimate other locomotor parameters such as top speed. In addition, the animations produced by this technique are qualitatively very convincing, which suggests that this may also be a useful technique for visualizing bipedal locomotion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to develop optical sensors for temperature monitoring in hydroelectric power plant heat exchangers. The proposed sensors are based on the Fiber Bragg Gratings technology. First of all, a prototype with three sensors inscribed in a same fiber was developed. This fiber was then fixed to a conventional Pt100 sensor rod and inserted in a thermowell. The ensemble was then calibrated in a workbench, presenting a maximum combined uncertainty of 2,06 °C. The sensor was installed in one of the heat exchangers of the Salto Osório’s hydroelectric power plant. This power plant is situated in the Iguaçu river, at the Paraná state. Despite the satisfactory results, the sensor was improved to a second version. In this, fifteen optical Bragg sensors were inscribed in a same fiber. The fixation with a conventional sensor was no longer necessary, because the first version results comproved the efficiency and response time in comparison to a conventional sensor. For this reason, it was decided to position the fiber inside a stainless steel rod, due to his low thermal expansion coefficient and high corrosion immunity. The utilization of fifteen fiber Bragg gratings aims to improve the sensor spatial resolution. Therefore, measurements every ten centimeters with respect to the heat exchanger’s height are possible. This provides the generation of a thermal map of the heat exchanger’s surface, which can be used for determination of possible points of obstruction in the hydraulic circuit of the heat exchanger. The heat exchanger’s obstruction in hydroelectric power plants usually occur by bio-fouling, and has direct influence in the generator’s cooling system efficiency. The obtained results have demonstrated the feasibility in application of the optical sensors technology in hydroelectric power plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The focus of this work is the automatic analysis of disturbance records for electrical power generating units. The main proposition is a method based on wavelet transform applied to short-term disturbance records (waveform records). The goal of the method is to detect the time instants of recorded disturbances and extract meaningful information that characterize the faults. The result is a set of representative information of the monitored signals in power generators. This information can be further classified by an expert system (or other classification method) in order to classify the faults and other abnormal operating conditions. The large amount of data produced by digital fault recorders during faults justify the research of methods to assist the analysts in their task of analysing the disturbances. The literature review pointed out the state of the art and possible applications for oscillography records. The review of the COMTRADE standard and wavelet transform underlines the choice of the method for solving the problem. The conducted tests lead to the determination of the best mother wavelet for the segmentation process. The application of the proposed method to five case studies with real oscillographic records confirmed the accuracy and efficiency of the proposed scheme. With this research, the post-operation analysis of occurrences is improved and as a direct result is the reduction of the time that generators are offline.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this dissertation I quantify residential behavior response to interventions designed to reduce electricity demand at different periods of the day. In the first chapter, I examine the effect of information provision coupled with bimonthly billing, monthly billing, and in-home displays, as well as a time-of-use (TOU) pricing scheme to measure consumption over each month of the Irish Consumer Behavior Trial. I find that time-of-use pricing with real time usage information reduces electricity usage up to 8.7 percent during peak times at the start of the trial but the effect decays over the first three months and after three months the in-home display group is indistinguishable from the monthly treatment group. Monthly and bi-monthly billing treatments are not found to be statistically different from another. These findings suggest that increasing billing reports to the monthly level may be more cost effective for electricity generators who wish to decrease expenses and consumption, rather than providing in-home displays. In the following chapter, I examine the response of residential households after exposure to time of use tariffs at different hours of the day. I find that these treatments reduce electricity consumption during peak hours by almost four percent, significantly lowering demand. Within the model, I find evidence of overall conservation in electricity used. In addition, weekday peak reductions appear to carry over to the weekend when peak pricing is not present, suggesting changes in consumer habit. The final chapter of my dissertation imposes a system wide time of use plan to analyze the potential reduction in carbon emissions from load shifting based on the Ireland and Northern Single Electricity Market. I find that CO2 emissions savings are highest during the winter months when load demand is highest and dirtier power plants are scheduled to meet peak demand. TOU pricing allows for shifting in usage from peak usage to off peak usage and this shift in load can be met with cleaner and cheaper generated electricity from imports, high efficiency gas units, and hydro units.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The insertion of distributed generation units in the electric power systems have contributed to the popularization of microgrid concepts. With the microgrids, several potential benefits can be achieved in regard to power quality and supply reliability. However, several technical challenges related to the control and operation of microgrids, which are associated with high insertion of generation systems based on static converters, must be overcame. Among the opportunities in the context of microgrids, there is the islanded operation of microgrids temporarily disconnected from the electric power systems and also the autonomous operation of geographically isolated microgrids. The frequency in large power systems is traditionally controlled by the generation units based on traditional synchronous generator. The insertion of distributed generation units based on static power converters may bring difficulties to the frequency control in microgrids, due to the reduction of the equivalent inertia of conventional synchronous generators present in islanded and isolated microgrids. In this context, it becomes necessary the proposition of new operational and control strategies for microgrids control, taking into account the presence of distributed generation units based on full-rated converter. This paper proposes an operational and control strategy for the islanded operation of a winddiesel microgrid with high insertion level of wind generation. The microgrid adopted in this study comprises of a wind energy conversion system with synchronous generator based on full rated converter, a diesel generator (DIG) and a dump load. Due to the high insertion level of wind generation, the wind unit operates in Vf mode and the diesel generator operates in PQ mode. The diesel generator and the dump load are used to regulate the DC-link voltage of the wind generation unit. The proposed control allows the islanded operation of the microgrid only with wind generation, wind-only mode (WO), and with wind-diesel generation, wind-diesel mode (WD). For the wind-only mode, with 100% of penetration level of wind generation, it is proposed a DC-link voltage control loop based on the use of a DC dump load. For the winddiesel mode, it is proposed a DC-link voltage control loop added to the diesel generator, which is connected to the AC side of the microgrid, in coordinated action with the dump load. The proposed operational and control strategy does not require the use of batteries and aims to maximize the energy production from wind generation, ensuring the uninterrupted operation of the microgrid. The results have showed that the operational and control strategy allowed the stable operation of the islanded microgrid and that the DC-link voltage control loop added to the diesel generator and the dump load proved to be effective during the typical variations of wind speed and load.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Miniaturization of power generators to the MEMS scale, based on the hydrogen-air fuel cell, is the object of this research. The micro fuel cell approach has been adopted for advantages of both high power and energy densities. On-board hydrogen production/storage and an efficient control scheme that facilitates integration with a fuel cell membrane electrode assembly (MEA) are key elements for micro energy conversion. Millimeter-scale reactors (ca. 10 µL) have been developed, for hydrogen production through hydrolysis of CaH2 and LiAlH4, to yield volumetric energy densities of the order of 200 Whr/L. Passive microfluidic control schemes have been implemented in order to facilitate delivery, self-regulation, and at the same time eliminate bulky auxiliaries that run on parasitic power. One technique uses surface tension to pump water in a microchannel for hydrolysis and is self-regulated, based on load, by back pressure from accumulated hydrogen acting on a gas-liquid microvalve. This control scheme improves uniformity of power delivery during long periods of lower power demand, with fast switching to mass transport regime on the order of seconds, thus providing peak power density of up to 391.85 W/L. Another method takes advantage of water recovery by backward transport through the MEA, of water vapor that is generated at the cathode half-cell reaction. This regulation-free scheme increases available reactor volume to yield energy density of 313 Whr/L, and provides peak power density of 104 W/L. Prototype devices have been tested for a range of duty periods from 2-24 hours, with multiple switching of power demand in order to establish operation across multiple regimes. Issues identified as critical to the realization of the integrated power MEMS include effects of water transport and byproduct hydrate swelling on hydrogen production in the micro reactor, and ambient relative humidity on fuel cell performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis discusses subgroups of mapping class groups of particular surfaces. First, we study the Torelli group, that is, the subgroup of the mapping class group that acts trivially on the first homology. We investigate generators of the Torelli group, and we give an algorithm that factorizes elements of the Torelli group into products of particular generators. Furthermore, we investigate normal closures of powers of standard generators of the mapping class group of a punctured sphere. By using the Jones representation, we prove that in most cases these normal closures have infinite index in the mapping class group. We prove a similar result for the hyperelliptic mapping class group, that is, the group that consists of mapping classes that commute with a fixed hyperelliptic involution. As a corollary, we recover an older theorem of Coxeter (with 2 exceptional cases), which states that the normal closure of the m-th power of standard generators of the braid group has infinite index in the braid group. Finally, we study finite index subgroups of braid groups, namely, congruence subgroups of braid groups. We discuss presentations of these groups and we provide a topological interpretation of their generating sets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this dissertation I draw a connection between quantum adiabatic optimization, spectral graph theory, heat-diffusion, and sub-stochastic processes through the operators that govern these processes and their associated spectra. In particular, we study Hamiltonians which have recently become known as ``stoquastic'' or, equivalently, the generators of sub-stochastic processes. The operators corresponding to these Hamiltonians are of interest in all of the settings mentioned above. I predominantly explore the connection between the spectral gap of an operator, or the difference between the two lowest energies of that operator, and certain equilibrium behavior. In the context of adiabatic optimization, this corresponds to the likelihood of solving the optimization problem of interest. I will provide an instance of an optimization problem that is easy to solve classically, but leaves open the possibility to being difficult adiabatically. Aside from this concrete example, the work in this dissertation is predominantly mathematical and we focus on bounding the spectral gap. Our primary tool for doing this is spectral graph theory, which provides the most natural approach to this task by simply considering Dirichlet eigenvalues of subgraphs of host graphs. I will derive tight bounds for the gap of one-dimensional, hypercube, and general convex subgraphs. The techniques used will also adapt methods recently used by Andrews and Clutterbuck to prove the long-standing ``Fundamental Gap Conjecture''.