915 resultados para Gelatinous polyethylene


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, the tensile strength of single-lap joints (SLJs) between similar and dissimilar adherends bonded with an acrylic adhesive was evaluated experimentally and numerically. The adherend materials included polyethylene (PE), polypropylene (PP), carbon-epoxy (CFRP), and glass-polyester (GFRP) composites. The following adherend combinations were tested: PE/PE, PE/PP, PE/CFRP, PE/GFRP, PP/PP, CFRP/CFRP, and GFRP/GFRP. One of the objectives of this work was to assess the influence of the adherends stiffness on the strength of the joints since it significantly affects the peel stresses magnitude in the adhesive layer. The experimental results were also used to validate a new mixed-mode cohesive damage model developed to simulate the adhesive layer. Thus, the experimental results were compared with numerical simulations performed in ABAQUS®, including a developed mixed-mode (I+II) cohesive damage model, based on the indirect use of fracture mechanics and implemented within interface finite elements. The cohesive laws present a trapezoidal shape with an increasing stress plateau, to reproduce the behaviour of the ductile adhesive used. A good agreement was found between the experimental and numerical results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho apresentado centra-se na determinação dos custos de construção de condutas de pequenos e médios diâmetros em Polietileno de Alta Densidade (PEAD) para saneamento básico, tendo como base a metodologia descrita no livro Custos de Construção e Exploração – Volume 9 da série Gestão de Sistemas de Saneamento Básico, de Lencastre et al. (1994). Esta metodologia descrita no livro já referenciado, nos procedimentos de gestão de obra, e para tal foram estimados custos unitários de diversos conjuntos de trabalhos. Conforme Lencastre et al (1994), “esses conjuntos são referentes a movimentos de terras, tubagens, acessórios e respetivos órgãos de manobra, pavimentações e estaleiro, estando englobado na parte do estaleiro trabalhos acessórios correspondentes à obra.” Os custos foram obtidos analisando vários orçamentos de obras de saneamento, resultantes de concursos públicos de empreitadas recentemente realizados. Com vista a tornar a utilização desta metodologia numa ferramenta eficaz, foram organizadas folhas de cálculo que possibilitam obter estimativas realistas dos custos de execução de determinada obra em fases anteriores ao desenvolvimento do projeto, designadamente numa fase de preparação do plano diretor de um sistema ou numa fase de elaboração de estudos de viabilidade económico-financeiros, isto é, mesmo antes de existir qualquer pré-dimensionamento dos elementos do sistema. Outra técnica implementada para avaliar os dados de entrada foi a “Análise Robusta de Dados”, Pestana (1992). Esta metodologia permitiu analisar os dados mais detalhadamente antes de se formularem hipóteses para desenvolverem a análise de risco. A ideia principal é o exame bastante flexível dos dados, frequentemente antes mesmo de os comparar a um modelo probabilístico. Assim, e para um largo conjunto de dados, esta técnica possibilitou analisar a disparidade dos valores encontrados para os diversos trabalhos referenciados anteriormente. Com os dados recolhidos, e após o seu tratamento, passou-se à aplicação de uma metodologia de Análise de Risco, através da Simulação de Monte Carlo. Esta análise de risco é feita com recurso a uma ferramenta informática da Palisade, o @Risk, disponível no Departamento de Engenharia Civil. Esta técnica de análise quantitativa de risco permite traduzir a incerteza dos dados de entrada, representada através de distribuições probabilísticas que o software disponibiliza. Assim, para por em prática esta metodologia, recorreu-se às folhas de cálculo que foram realizadas seguindo a abordagem proposta em Lencastre et al (1994). A elaboração e a análise dessas estimativas poderão conduzir à tomada de decisões sobre a viabilidade da ou das obras a realizar, nomeadamente no que diz respeito aos aspetos económicos, permitindo uma análise de decisão fundamentada quanto à realização dos investimentos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Dissertação de Natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A indústria de transformação de material plástico contribui de forma relevante para o desenvolvimento da economia mundial. Com o objetivo de desenvolvimento dessa indústria, a empresa Pentaplast S. A., situada em Água Longa, Santo Tirso, desenvolve a conceção de novos produtos para novas aplicações. Esta empresa para continuar na posição de destaque que possui, tem que conduzir a sua existência na melhoria contínua e atualização fase ao mercado. Na indústria termoformadora existe uma procura constante de novos materiais, visto ser um mercado muito competitivo. Neste contexto, o presente trabalho tem como objetivo desenvolver um filme plástico com o aspeto de papel para a indústria termoformadora, criando desta forma um impacto no consumidor para a preocupação ambiental. De forma a encontrar soluções para o problema mencionado, conduziu-se ao estudo e desenvolvimento de um novo produto – Paper Like, sendo este, um produto reciclável e adotado às necessidades da termoformação. Para isso, desenvolveu-se o projeto utilizando o processo de termolaminação, com a adição de um aditivo na camada externa, permitindo incorporar ao filme plástico, o aspeto e textura de papel. Foram testados, separadamente, dois aditivos, X e Y, base PET e PE, respetivamente, com diferentes percentagens de incorporação. O aditivo X foi desenvolvido especialmente para este projeto, tendo como base politereftalato de etileno, no entanto com a sua incorporação não se obteve os resultados esperados, somente dava um aspeto mate ao filme extrudidos. O aditivo Y, já existe no mercado mas nunca utilizado em extrusão plana, tem como base polietileno e a sua incorporação permitiu obter um filme com aspeto de papel, comprovando-se a sua compatibilidade com pigmentos, os quais dão diversas cores aos filmes, permitindo assim competir com os filmes tradicionais. Infelizmente a termolaminação do filme com o aditivo Y não foi possível, o que inviabiliza a selagem da embalagem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissertação foi realizada em ambiente industrial, mais precisamente na empresa Monteiro, Ribas – Embalagens Flexíveis, S.A.. Esta empresa dedica-se à impressão e laminagem de filmes, assim como à confeção de sacos. Os seus produtos são direcionados na sua maioria para a indústria alimentar, exportando mais de 50% da sua produção, e dizem respeito a complexos (dois ou mais filmes unidos pela presença de um adesivo) que podem possuir impressão ou não. Estes complexos podem ser enviados para o cliente em bobina ou já em saco. Os objetivos propostos pela empresa diziam respeito a estudos relacionados com a força de laminagem dos complexos, com o coeficiente de atrito dos mesmos e com a identificação dos espetros dos componentes dos adesivos, assim como o estudo do processo de reticulação dos mesmos por espetrofotometria de Infravermelho. Relativamente aos resultados obtidos verificou-se que tanto a tinta como os metalizados influenciam negativamente a força de laminagem. Por sua vez o coeficiente de atrito é afetado por vários fatores. Através dos ensaios experimentais verificou-se que o adesivo, a tinta e o verniz mate favorecem o aumento do valor do COF. Além disso, nos complexos em que se utilizaram filmes de polietileno de maior espessura obtiveram-se valores de COF mais baixos, e no que diz respeito à temperatura e à tensão de enrolamento, verificou-se que valores mais elevados e muito baixos da primeira traduzem-se num aumento do valor do COF e uma tensão de enrolamento maior também tem o mesmo efeito. Relativamente ao tipo de filme impresso, substratos com maior energia superficial atraem mais o agente de deslizamento (slip). Por último, não se conseguiu perceber qual o tipo de adesivo (com ou sem solvente) que tem maior impacto no COF uma vez que em 55% dos casos o valor do COF é superior nas amostras que foram complexadas com adesivo sem solvente e em 45% o COF era superior nas amostras complexadas com adesivo base solvente. No que diz respeito aos espetros obtidos verificou-se que a reticulação dos adesivos é identificada pela diminuição da extensão do pico correspondente à ligação N=C=O.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Hepatitis C virus (HCV) induces chronic infection in 50% to 80% of infected persons; approximately 50% of these do not respond to therapy. We performed a genome-wide association study to screen for host genetic determinants of HCV persistence and response to therapy. METHODS: The analysis included 1362 individuals: 1015 with chronic hepatitis C and 347 who spontaneously cleared the virus (448 were coinfected with human immunodeficiency virus [HIV]). Responses to pegylated interferon alfa and ribavirin were assessed in 465 individuals. Associations between more than 500,000 single nucleotide polymorphisms (SNPs) and outcomes were assessed by multivariate logistic regression. RESULTS: Chronic hepatitis C was associated with SNPs in the IL28B locus, which encodes the antiviral cytokine interferon lambda. The rs8099917 minor allele was associated with progression to chronic HCV infection (odds ratio [OR], 2.31; 95% confidence interval [CI], 1.74-3.06; P = 6.07 x 10(-9)). The association was observed in HCV mono-infected (OR, 2.49; 95% CI, 1.64-3.79; P = 1.96 x 10(-5)) and HCV/HIV coinfected individuals (OR, 2.16; 95% CI, 1.47-3.18; P = 8.24 x 10(-5)). rs8099917 was also associated with failure to respond to therapy (OR, 5.19; 95% CI, 2.90-9.30; P = 3.11 x 10(-8)), with the strongest effects in patients with HCV genotype 1 or 4. This risk allele was identified in 24% of individuals with spontaneous HCV clearance, 32% of chronically infected patients who responded to therapy, and 58% who did not respond (P = 3.2 x 10(-10)). Resequencing of IL28B identified distinct haplotypes that were associated with the clinical phenotype. CONCLUSIONS: The association of the IL28B locus with natural and treatment-associated control of HCV indicates the importance of innate immunity and interferon lambda in the pathogenesis of HCV infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vaniprevir (MK-7009) is a macrocyclic hepatitis C virus (HCV) nonstructural protein 3/4A protease inhibitor. The aim of the present phase II study was to examine virologic response rates with vaniprevir in combination with pegylated interferon alpha-2a (Peg-IFN-α-2a) plus ribavirin (RBV). In this double-blind, placebo-controlled, dose-ranging study, treatment-naïve patients with HCV genotype 1 infection (n = 94) were randomized to receive open-label Peg-IFN-α-2a (180 μg/week) and RBV (1,000-1,200 mg/day) in combination with blinded placebo or vaniprevir (300 mg twice-daily [BID], 600 mg BID, 600 mg once-daily [QD], or 800 mg QD) for 28 days, then open-label Peg-IFN-α-2a and RBV for an additional 44 weeks. The primary efficacy endpoint was rapid viral response (RVR), defined as undetectable plasma HCV RNA at week 4. Across all doses, vaniprevir was associated with a rapid two-phase decline in viral load, with HCV RNA levels approximately 3 log(10) IU/mL lower in vaniprevir-treated patients, compared to placebo recipients. Rates of RVR were significantly higher in each of the vaniprevir dose groups, compared to the control regimen (68.8%-83.3% versus 5.6%; P < 0.001 for all comparisons). There were numerically higher, but not statistically significant, early and sustained virologic response rates with vaniprevir, as compared to placebo. Resistance profile was predictable, with variants at R155 and D168 detected in a small number of patients. No relationship between interleukin-28B genotype and treatment outcomes was demonstrated in this study. The incidence of adverse events was generally comparable between vaniprevir and placebo recipients; however, vomiting appeared to be more common at higher vaniprevir doses. CONCLUSION: Vaniprevir is a potent HCV protease inhibitor with a predictable resistance profile and favorable safety profile that is suitable for QD or BID administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Switzerland was the first country to approve certolizumab pegol (Cimzia, CZP) for the treatment of patients with moderate to severe Crohn's disease (CD) in September 2007. This phase IV study aimed to evaluate the efficacy and safety of CZP in a Swiss multicenter cohort of practice-based patients. Methods: Baseline and Week 6 evaluation questionnaires were sent to all Swiss gastroenterologists in hospitals and private practices. Disease activity was assessed with the Harvey-Bradshaw Index (HBI) and adverse events were evaluated according to WHO guidelines. Results: Fifty patients (31 women, 19 men) were included; 56% had complicated disease (stricture or fistula) and 52% had undergone prior CD-related surgery. All patients. had prior exposure to systemic steroids, 96% to immunomodulators, 78% to infliximab, and 50% to adalimumab. A significant decrease in HBI was observed at Week 6 (versus Week 0) following induction therapy with CZP 400 mg subcutaneously at Weeks 0, 2, and 4 (12.6 +/- 4.7 Week 0 versus 6.2 +/- 4.4 Week 6, P < 0.001). Response and remission rates at Week 6 were 54% and 40%, respectively. We identified 8/11 CD patients undergoing a 50% fistula response (P = 0.021). The frequency of adverse drug reactions attributed to CZP was 6%. CZP was continued in 80% of patients beyond Week 6. Conclusions: In a population of CD patients with complicated disease behavior, CZP induced a response and remission in 54% and 40% of patients, respectively. This series provides the first evidence of the effectiveness of CZP in perianal fistulizing CD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The kinetic study of the coupled enzymatic reaction involving monomeric yeast hexokinase PII (HK) and yeast glucose-6-phosphate dehydrogenase (G-6-PDH) yields a Michaelis constant of 0.15 ± 0.01 mM for D-glucose. At pH 8.7 HK is present in monomeric form. The addition of polyethylene glycol (PEG), to the reaction mixture increased the affinity of HK for glucose, independent ofMW of the PEG from 2000 to 10000. The osmotic stress exerted by PEG can be used to measure the change in number of water molecules that accompany enzyme conformational changes (Rand, et al., 1993). Results indicate that the G-6-PDH is not osmotically sensitive and thus, the change in the number of PEG-inaccessible water molecules (ANw) measured in the coupled reaction is only the difference between the glucose-bound and glucosefree conformations of HK. ANw ~ 450 with PEGs of MW > 2000 under conditions for both binding (Reid and Rand, 1997) and kinetic assays. The contribution water may play in the binding of ATP (Km = 0.24 + 0.02 mM) has also been examined. It was found that in this case ANw = (for osmotic pressures < 2.8x10* dynes/cm^), suggesting no additional numbers of waters are displaced when ATP binds to HK. Osmotic pressure experiments were also performed with dimeric HK. It was determined that both the monomeric and dimeric forms of HK give the same ANw under low pressures. If this large ANw is due to conformational flexibility, it would appear that the flexibility is not reduced upon dimerization ofthe enzyme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present thesis, the role of hydration during the glucose induced conformational change of hexokinase is investigated. This is accomplished by applying the osmotic stress technique. The osmotic stress technique is founded on varying of the activity of water in a system in order to determine ifs effects. This is accomplished by adding inert solute molecules that are excluded from the system under study. The solute molecules used within the present investigation are Polyethylene glycols (PEGs). PEGs aid in the removal of water from hexokinase by exerting osmotic pressure. The osmotic pressures of the PEG solutions are also measured with both vapour pressure osmometry and secondary osmometry with phospholipids. An interesting discovery is made in that the osmotic pressures of PEG and co-solute solutions are non-additive. This indicates that PEG concentrates co-solutes in solution by making a certain proportion of the water inaccessible. Glucose binding was measured fluorometrically and the glucose equilibrium dissociation constant (GEDC) of hexokinase is measured in solutions containing the different MW PEGs. Changes in the sensitivity of the glucose affinity with osmotic pressure allows the calculation of the change in the numbers of polymer-inaccessible water molecules upon the binding of glucose to hexokinase ~Nw. It was determined the ~Nw decreases with increases in osmotic pressure in the presence of all MW PEGs. ~Nw decreases from values between 45-290 water molecules at low pressure to approximately 15 at high pressure. There is also a molecular weight dependence observed. There are large decreases in ~Nw with osmotic pressure in the presence of PEGs above MW 1000. However, below MW 1500 changes in ~Nw with osmotic pressure are relatively small. These findings are interpreted with respect to two possible mechanisms involving changes in the conformation of hexokinase u~der osmotic pressure and the access of the PEG molecules to water surrounding hexokinase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The primary objective of this investigation was that of providing a comprehensive tissue-by-tissue assessment of water-electrolyte status in thermally-acclimated rainbow trout, Salmo gairdneri. To this end levels of water and the major ions, sodium, chloride and potassium were evaluated in the plasma, at three skeletal muscle sites, and in cardiac muscle, liver, spleen, gut and brain of animals acclimated to 2°, 10° and 18°C. The occurrence of possible seasonal variations in water-electrolyte balance was evaluated by sampling sununer and late fall-early winter populations of trout. On the basis of values for water and electrolyte content, estimates of extracellular and cellular phase volumes, cellular electrolyte concentrations and Nernst equilibrium potentials were made. Since accurate assessment of the extracellular phase volume is critical in the estimation of cellular electrolyte concentrations and parameters based on assumed cellular ion levels, [14 C]-polyethylene glycol-4000, which is assumed to be confined to the extracellular space, was employed to provide comparisons with various ion-defined spaces (H20~~s, H20~~/K and H20~~s). Subsequently, the ion-defined space yielding the most realistic estimate of extracellular phase volume for each tissue was used in cellular electrolyte calculations. Water and electrolyte content and distribution varied with temperature. Tissues, such as liver, spleen and brain appeared to be the most thermosensitive, whereas skeletal and cardiac muscle and gut tissue were less influenced. 'Summer' series trout appeared to be more capable of maintaining their water- electrolyte balance than the ~fall-winter' series animals. i The data are discussed in terms of their possible effect on maintenance of appropriate cellular metabolic and electrophysiological functions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les détecteurs ATLAS-MPX sont des détecteurs Medipix2-USB recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons lents et des neutrons rapides respectivement. Un réseau de quinze détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Deux détecteurs ATLAS-MPX de référence ont été exposés à des sources de neutrons rapides 252 Cf et 241 AmBe ainsi qu’aux neutrons rapides produits par la réaction 7Li(p, xn) pour l’étude de la réponse du détecteur à ces neutrons. Les neutrons rapides sont principalement détectés à partir des protons de recul des collisions élastiques entre les neutrons et l’hydrogène dans le polyéthylène. Des réactions nucléaires entre les neutrons et le silicium produisent des particules-α. Une étude de l’efficacité de reconnaissance des traces des protons et des particules-α dans le détecteur Medipix2-USB a été faite en fonction de l’énergie cinétique incidente et de l’angle d’incidence. L’efficacité de détection des neutrons rapides a été évaluée à deux seuils d’énergie (8 keV et 230 keV) dans les détecteurs ATLAS-MPX. L’efficacité de détection des neutrons rapides dans la région du détecteur couverte avec le polyéthylène augmente en fonction de l’énergie des neutrons : (0.0346 ± 0.0004) %, (0.0862 ± 0.0018) % et (0.1044 ± 0.0026) % pour des neutrons rapides de 2.13 MeV, 4.08 MeV et 27 MeV respectivement. L’étude pour déterminer l’énergie des neutrons permet donc d’estimer le flux des neutrons quand le détecteur ATLAS-MPX est dans un champ de radiation inconnu comme c’est le cas dans le détecteur ATLAS au LHC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectif—Comparer les effets de la stérilisation au plasma de gaz de peroxyde d’hydrogène (HPGP) à l’oxyde d’éthylène (EO) et à la vapeur (ST) sur les propriétés physico-chimiques et d’adhésion bactérienne de fils de nylon et de polyéthylène. Design expérimental—Etude in vitro. Matériel—Des brins non stérilisés, stérilisés au HPGP, à l’EO et ST; de fil nylon leader (FNL), de fil de nylon pêche (FNP) et de fil de polyéthylène (PE) ont été utilisés. Méthodes—Une analyse de surface au spectroscope photo-électronique à rayons X (XPS), une mesure de l’angle de contact, une analyse par microscopie à force atomique (AFM) et l’adhésion bactérienne de Staphylococcus intermedius et d’Escherichia Coli ont été testés sur les brins. Résultats—Une oxydation de la surface de tous les échantillons stérilisés a été observée quelque soit la méthode de stérilisation. La stérilisation a augmenté significativement l’angle de contact pour tous les types de fil quelque soit la méthode. La rugosité n’a pas été affectée significativement par la méthode de stérilisation pour le FNL et FNP. L’adhésion bactérienne a été affectée significativement par la méthode de stérilisation. Le PE a un angle de contact, une rugosité et une adhésion bactérienne significativement plus élevée que le FNL et FNP, peu importe la méthode de stérilisation. Conclusion—La stérilisation au HPGP constitue une alternative intéressante à la vapeur et l’EO. Le PE n’est peut être pas un matériel idéal par sa capacité d’adhésion bactérienne. De futures études sont nécessaires pour déterminer la signification clinique de ces trouvailles.