960 resultados para Gel permeation chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comprehensive two-dimensional liquid chromatographic separation system based on the combination of a CN column and an ODS column is developed for the separation of components in a traditional Chinese medicine (TCM) Rhizoma chuanxiong. Two columns are coupled by a two-position, eight-port valve equipped with two storage loops and controlled by a computer. The effluent is detected by both the diode array detector and atmospheric pressure chemical ionization (APCI) mass spectrometer. More than 52 components in the methanol extract of R. chuanxiong were resolved and 11 of them were preliminary identified according to their UV and mass spectra. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamic flow profiles and column efficiencies in conically shaped semi-preparative liquid chromatographic columns (inlet ID larger than outlet ID) with two different conical angles (7degrees and 15degrees) were studied. The dynamic flow profiles were studied by an on-column visualization method. Conical columns were compared with cylindrical column of the same length and internal volume. The results showed that the flow profile of a sample band in the conical column of 7degrees (50 mm x 17 mm --> 11 mm ID) was parabolic in shape. The sample band migrated slower in the wall region than in the central region, as in the cylindrical column (50 mm x 14 mm ID). However, the sample band in the conical column of 15degrees (50 mm x 20 mm --> 7 mm ID) migrated slower in the central region than in the wall region, resulting in a reverse parabolic flow profile, in contrast to that in cylindrical column. This indicated that a flat flow profile might be realized in a conical column with a conical angle between 7degrees and 15degrees. The conical column of 15degrees had the highest column efficiency among the three columns under the same conditions. Compared with the cylindrical column packed with identical packing material, the conical column of 15degrees had 22%-45% higher column efficiency and 11%-27% higher peak height.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports an analytical method for separating, identifying and quantitating sulfur-containing compounds and their groups in diesel oils (170-400degreesC) using comprehensive two-dimensional gas chromatography coupled with a sulfur chemiluminescence detector. The identification of target compounds and their groups was based on standard substances, the group separation feature and the-effect of comprehensive two-dimensional gas chromatography. The quantitative analysis on major sulfur compounds and total sulfur was carried out based on the linear response of sulfur chemiluminescence detector and the internal standards method. The results of total sulfur determination in the samples were compared with those from ASTM D 4294 standard method, the R.S.D. percentage were <6.02%, correctness of this method can meet the industrial requirement. To the end, the method developed was used to investigate the sulfur-containing compounds in different diesel oils, the result shows that the distribution of sulfur-containing compounds in diesel oils from different process units are apparently different. The sulfur compounds in fluid catalytic cracking (FCC), residuum fluid catalytic cracking (RFCC) diesel oils mainly exist in the form of alkyl-substituted dibenzothiophenes that add up to about 40-50% of the total sulfur, while this number is only 6-8 and 20-28% in visbreaking (VB) and delayed-coking (DC) diesel oils, respectively. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cellulose trisphenylcarbamate-bonded chiral stationary phase was applied to nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) with nonaqueous and aqueous solutions as the mobile phases. Several chiral compounds were successfully resolved on the prepared phase by nano-LC. The applicability of nonaqueous CEC on a cellulose derivative stationary phase was investigated with the organic solvents methanol, hexane, 2-propanol, and tetrahydrofuran (THF) containing acetic acid, as well as triethylamine as the mobile phases. Enantiomers of warfarin and praziquantel were baseline-resolved with plate numbers of 82 300 and 38 800 plates/m, respectively, for the first eluting enantiomer. The influence of applied voltage, concentration of nonpolar solvent, apparent pH, and buffer concentration in the mobile phase on the electroosmotic flow (EOF) and the mobility of the enantiomers was evaluated. Enantioseparations of traps-stilbene oxide and praziquantel were also achieved in aqueous CEC with plate numbers of 111 100 and 107 400 plates/m, respectively, for the first eluting enantiomer. A comparison between nonaqueous CEC and aqueous CEC based on a cellulose trisphenylcarbamate stationary phase was discussed. Pressure-assisted CEC was examined for the chiral separation of praziquantel and faster analysis with high enantioselectivity was acquired with the proper pressurization of the inlet vial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, sensitive, and mild method for the determination of amino compounds based on a condensation reaction with fluorescence detection has been developed. 9-(2-Hydroxyethyl)acridone reacts with coupling agent N,N-carbonyldiimidazole at ambient temperature to form activated amide intermediate 9-(2-acridone)oxyethylcarbonylimidazole (AOCD). The amide intermediate (AOCD) preferably reacts with amino compounds under mild reactions in the presence of 4-(dimethylamino)pyridine (base catalyst) in acetonitrile to give the corresponding sensitively fluorescent derivatives with an excitation maximum lambda(ex) 404 mn and an emission maximum at lambda(em) 440 nm. The labeled derivatives exhibit high stability under reversed-phase conditions. The fluorescence intensities of derivatives in various solvents or at different temperatures were investigated. The method, in conjunction with a gradient elution, offers a baseline resolution of the common amine derivatives on a reversed-phase C-18 column. The LC separation for the derivatized amines shows good reproducibility with acetonitrile-water including 2.5% DMF as mobile phase. The relative standard deviations (n = 6) for each amine derivative are <4.5%. The detection limits (at a signal-to-noise ratio of 3) per injection were 0.16-12.8 ng/mL. Further research for the field of application, based on the AOCD amide intermediate as derivatization reagent, for the determination of free amines in real water samples is achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the objective of making calcium alginate gel beads with small and uniform size, membrane emulsification coupled with internal gelation was proposed. Spherical gel beads with mean size of about 50 mum, and even smaller ones in water, and with narrow size distribution were successfully obtained. Experimental studies focusing mainly on the effect of process parameters on bead properties were performed. The size of the beads was mainly dependent on the diameter of the membrane pores. High transmembrane pressure made for large gel beads with wide size distribution. Low sodium alginate concentration produced nonspherical beads, whereas a high concentration was unsuitable for the production of small beads with narrow distribution. Thus 1.5% w/v was enough. A high surfactant concentration favored the formation of small beads, but the adverse effect on mass transfer should be considered in this novel process. (C) 2002 Wiley Periodicals, Inc.