951 resultados para Fungi.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

1972

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nesta dissertação procurou-se comparar os desempenhos de três produtos de proteção da madeira quando expostos a várias condições de degradação. Tendo em consideração a grande quantidade de variáveis quando se faz este tipo de estudos, tentou-se controlar o maior número possível destas, de modo a permitir a comparação com outros estudos que venham a ser feitos futuramente. O objetivo a longo prazo é a contribuição desta dissertação para um conjunto de resultados cada vez mais abrangente, facilitando a escolha do utilizador, quando pretender proteger a madeira das agressões exteriores com este tipo de produtos. A principal conclusão nesta dissertação é que a agressividade do meio tem um papel determinante para os resultados obtidos, bem como as condições de inclinação e orientação da madeira. Situações de má selagem de topos ou não consideração da presença agentes biológicos são outros dois fatores que influenciam a durabilidade da construção. Finalmente, concluiu-se que não existem soluções únicas, tendo que se estudar caso a caso, quais as condições exatas de exposição, de forma a escolher o produto, ou produtos, mais adequados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies suggest that sand can serve as a vehicle for exposure of humans to pathogens at beach sites, resulting in increased health risks. Sampling for microorganisms in sand should therefore be considered for inclusion in regulatory programmes aimed at protecting recreational beach users from infectious disease. Here, we review the literature on pathogen levels in beach sand, and their potential for affecting human health. In an effort to provide specific recommendations for sand sampling programmes, we outline published guidelines for beach monitoring programmes, which are currently focused exclusively on measuring microbial levels in water. We also provide background on spatial distribution and temporal characteristics of microbes in sand, as these factors influence sampling programmes. First steps toward establishing a sand sampling programme include identifying appropriate beach sites and use of initial sanitary assessments to refine site selection. A tiered approach is recommended for monitoring. This approach would include the analysis of samples from many sites for faecal indicator organisms and other conventional analytes, while testing for specific pathogens and unconventional indicators is reserved for high-risk sites. Given the diversity of microbes found in sand, studies are urgently needed to identify the most significant aetiological agent of disease and to relate microbial measurements in sand to human health risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fitness centres are special places where conditions for microbiological proliferation should be considered. Moisture due to human perspiration and water condensation as a result of human physical activities are prevalent in this type of buildings. Exposure to microbial contaminants is clinically associated with respiratory disorders and people who work out in polluted environments would be susceptible to contaminants. This work studied the indoor air contamination in three gymnasiums in Lisbon. The sampling was performed at two periods: at the opening (morning) and closing (night) of the three gymnasiums. The airborne bacterial and fungal populations were sampled by impaction directly onto Tryptic Soy Agar (for bacteria) and Malt Extract Agar (for fungi) plates, using a Merck MAS-100 air sampler. Higher bacterial concentrations were found at night as compared to the morning but the same behaviour was not found for fungal concentrations. Gram-negative catalase positive cocci were the dominant bacteria in indoor air samples of the studied gymnasiums. In this study, 21 genera/species of fungal colonies were identified. Chrysosporium sp., Chrysonilia sp., Neoscytalidium hialinum, Sepedonium sp. and Penicillium sp. were the most prevalent species identified in the morning, while Cladosporium sp., Penicillium sp., Chrysosporium sp., Acremonium sp. and Chrysonilia sp. were more prevalent at night. A well-designed sanitation and maintenance program for gymnasiums is needed to ensure healthier space for indoor physical activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper refers to the assessment on site by semi-destructive testing (SDT) methods of the consolidation efficiency of a conservation process developed by Henriques (2011) for structural and non-structural pine wood elements in service. This study was applied on scots pine wood (Pinus sylvestris L.) degraded by fungi after treatment with a biocidal product followed by consolidation with a polymeric product. This solution avoids substitutions of wood moderately degraded by fungi, improving its physical and mechanical characteristics. The consolidation efficiency was assessed on site by methods of drill resistance and penetration resistance. The SDT methods used showed good sensitivity to the conservation process and could evaluate their effectiveness. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cork stopper manufacturing process includes an operation, known as stabilisation, by which humid cork slabs are extensively colonised by fungi. The effects of fungal growth on cork are yet to be completely understood and are considered to be involved in the so called “cork taint” of bottled wine. It is essential to identify environmental constraints which define the appearance of the colonising fungal species and to trace their origin to the forest and/or as residents in the manufacturing space. The present article correlates two sets of data, from consecutive years and the same season, of systematic biologic sampling of two manufacturing units, located in the North and South of Portugal. Chrysonilia sitophila dominance was identified, followed by a high diversity of Penicillium species. Penicillium glabrum, found in all samples, was the most frequent isolated species. P. glabrum intra-species variability was investigated using DNA fingerprinting techniques revealing highly discriminative polymorphic markers in the genome. Cluster analysis of P. glabrum data was discussed in relation to the geographical location of strains, and results suggest that P. glabrum arise from predominantly the manufacturing space, although cork resident fungi can also contrib

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Biology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fungi have been considered a potential source of natural anticancer drugs. However, studies on these organisms have mainly focused on compounds present in the sporocarp and mycelium. The aim of this study was to assess the anticancer potential of fungal spores using a bioassay-guided fractionation with cancer and normal cell lines. Crude extracts from spores of the basidiomycetous fungus Pisolithus tinctorius were prepared using five solvents/solvent mixtures in order to select the most effective crude extraction procedure. A dichloromethane/methanol (DCM/MeOH) mixture was found to produce the highest extraction yield, and this extract was fractionated into 11 fractions. Crude extracts and fractions were assayed for cytotoxicity in the human osteocarcinoma cell line MG63, the human breast carcinoma cell line T47D, the human colon adenocarcinoma cell line RKO, and the normal human brain capillary endothelial cell line hCMEC/D3. Cytotoxicity was assessed by the 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) reduction assay. The results showed a reduction in cancer cell viability of approximately 95% with 4 of 11 fractions without a significant reduction in viability of hCMEC/D3 cells. Data demonstrated that spores of P. tinctorius might serve as an interesting source of compounds with potential anticancer properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação descreve o trabalho desenvolvido ao longo de um ano e um mês desde a pesquisa teórica até à prática experimental no âmbito da unidade curricular de Dissertação/estágio do Mestrado em Engenharia Química, no ramo Tecnologias em Proteção Ambiental. O tema desta dissertação consiste na avaliação do funcionamento de duas estações de tratamento de águas residuais (ETAR) do interior do município de Vila Nova de Gaia no que diz respeito ao possível aumento da resistência a antibióticos na ETAR de Febros e na ETAR de Lever. Os testes de sensibilidade a antibióticos (TSA) foram executados para ambas as ETAR, sendo as amostras de água recolhidas na entrada e na saída dos reatores biológicos (tratamento secundário). Além disso, foram realizados testes de avaliação da eficiência de desinfeção por radiação ultravioleta (UV) relativamente à Escherichia coli (E. coli) na ETAR de Lever. Os antibióticos selecionados para a realização deste trabalho foram a Eritromicina, a Azitromicina, a Claritromicina, a Ofloxacina, a Ciprofloxacina, o Sulfametoxazol, o Trimetoprim e o Metronidazol. Esta seleção baseou-se no facto de estes serem alguns dos antibióticos mais consumidos e mais persistentes no meio ambiente. A bactéria E. coli (isolada a partir de amostras das águas residuais estudadas) foi escolhida para a realização deste estudo uma vez que está sempre presente nas águas residuais domésticas e está associada a fenómenos de multirresistência a antibióticos. Os testes de TSA foram realizados seguindo a metodologia de difusão por discos. No período do estudo (Março a Junho de 2015) identificaram-se situações quer de aumento de resistência quer de aumento de sensibilidade aos antibióticos testados. As situações mais graves de aumento de resistência, a que corresponderam a halos nulos, verificaram-se para os antibióticos Claritromicina, Trimetoprim e Metronidazol, ocorrendo com maior frequência para os dois últimos, que aliás são fármacos que são administrados em simultâneo. Os períodos mais problemáticos em termos de aumento das resistências foram ligeiramente diferentes nas duas ETAR. No caso da ETAR de Febros correspondeu ao mês Abril e na ETAR de Lever ocorreu entre o final de Abril e o início de Maio. Considera-se que estes períodos poderão coincidir com um aumento do consumo destes fármacos devido à sua utilização no combate a infeções respiratórias muito comuns nesta altura do ano. Não se observou qualquer sensibilidade da E. coli para o Metronidazol porque é um antibiótico com indicação para algumas bactérias anaeróbias, fungos e giardia, e que à partida não tem capacidade para eliminar a E. coli. A eficiência da desinfeção na ETAR de Lever relativamente à remoção de E. coli foi satisfatória. Sendo de salientar a importância da manutenção, no que se refere à identificação de possíveis avarias nas lâmpadas e correspondente limpeza. Os resultados deste trabalho provam a existência de estirpes da bactéria E. coli resistentes a alguns dos antibióticos estudados, o que reforça a importância da desinfeção no tratamento de águas residuais domésticas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grapevine is one of the most cultivated fruit crop worldwide with Vitis vinifera being the species with the highest economical importance due to the high quality standards of its berries. Nonetheless, it is also the most susceptible Vitis species to fungal pathogens. Among others, relevant fungal diseases currently threatening grapevine cultures are powdery mildew, caused by Erysiphe necator, and esca, a disease complex comprised of several fungi in which Phaeomoniella chlamydospora and Phaeoacremonium aleophilum participate.(...)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main results presented in this PhD Dissertation have been published in interna-tional journals included in the Science Citation Index (SCI)