970 resultados para Flexible airport terminal design


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlamydia trachomatis has a unique obligate intracellular developmental cycle that ends by the lysis of the cell and/or the extrusion of the bacteria in order to allow for re-infections. While Chlamydia trachomatis infections are often asymptomatic the diagnosis of Chlamydia trachomatis is usually late, occurring after manifestation of persistency. Investigations on the consequences of long-term infections and the molecular mechanisms behind it will reveal light to what extent bacteria can modulate host cell function and what the ultimate fate of host cells after clearance of an infection is. Such studies on the host cell fate could be greatly facilitated if the infected cells become permanently marked during and after the infection. Therefore, this project intends to develop a new genetic tool that would allow permanently labeling of Chlamydia trachomatis host cells. The plan was to generate a Chlamydia trachomatis strain that encodes a recombinant CRE recombinase, fused to a secretory effector function of the Chlamydia type 3 secretion system (T3SS). Upon translocation into the host cell, this recombinant CRE enzyme could then, owing to its site-specific recombination function, switch a reporter gene contained in the host cell genome. To this end, the reporter line carried a membrane-tagged tdTomato (mT) gene flanked by two LoxP sequences followed by a GFP gene. The translocation of the recombinant CRE recombinase into this cell line was designed to trigger the recombination of the LoxP sites whereby the cells would turn from red fluorescence to green as an irreversible label of the infected cells. Successful execution of this mechanism would allow to draw a direct link between Chlamydia trachomatis infection and the subsequent fate of the infected cell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO:RESUMO: Nos últimos anos a ultrassonografia emergiu como um instrumento importante no diagnóstico da patologia torácica. O progresso tecnológico possibilitou a conceção de novos equipamentos como a ecoendoscopia brônquica radial e linear. Verificou-se, igualmente, o aparecimento de indicações para a realização de ecografia transtorácica. Uma das principais doenças impulsionadoras da técnica ultrassonográfica no tórax foi o cancro do pulmão, primeira causa de morte oncológica a nível mundial. A aplicabilidade e conhecimento do papel dos ultrassons no âmbito do diagnóstico e estadiamento do cancro do pulmão não se encontram esgotados, persistindo focos de controvérsia e dúvida científica que se pretendem esclarecer. A presente tese foi organizada em cinco capítulos: o primeiro abordou de forma geral e introdutória o estado da arte referente à ultrassonografia torácica, cancro do pulmão e a sua conjugação; o segundo destacou os principais objetivos; o terceiro sumarizou a metodologia utilizada; o quarto englobou os cinco estudos publicados, descritos subsequentemente, e o quinto incluiu uma discussão concisa, as principais conclusões e perspetivas futuras. O primeiro estudo avaliou a rentabilidade diagnóstica, segurança e curva de aprendizagem num coorte de 179 doentes submetidos a ecoendoscopia brônquica linear. De acordo com as indicações para este procedimento os doentes foram subdivididos em três grupos: (1) diagnóstico, (2) diagnóstico e estadiamento e (3) estadiamento. Para o primeiro, segundo e terceiro grupos a sensibilidade da ecoendoscopia foi 86.1%, 86.7% e 95% respetivamente e a precisão técnica foi 87.5%, 93.1% e 97.7% respetivamente. O treino originou um aumento progressivo do número de locais puncionados por doente, com menor duração e sem complicações, comprovando a eficácia e segurança do método quando realizado na população Portuguesa por broncologistas com experiência. O segundo estudo foi conduzido para averiguar a eficácia e custo da ecoendoscopia brônquica linear realizada através da via aérea e/ou esófago no diagnóstico de lesões sugestivas de neoplasia do pulmão, após ineficácia das técnicas convencionais. Nos doentes incluídos prospetivamente alcançou-se um diagnóstico definitivo em 106 casos (87.6%). A sensibilidade global para o diagnóstico de cancro do pulmão foi 89.8%, a especificidade foi 100%, o valor preditivo positivo foi 100%, o valor preditivo negativo foi 20% e a precisão foi 90.1%. Esta estratégia ultrassonográfica abrangente evitou intervenções cirúrgicas diagnósticas em doentes anteriormente submetidos a broncoscopia flexível ou punção aspirativa transtorácica guiada por tomografia computorizada, proporcionando uma redução significativa dos custos. No terceiro estudo investigou-se a viabilidade e papel da conjugação da ecoendoscopia brônquica linear com técnicas moleculares na avaliação de antigénios tumorais e padrões de metastização ganglionar em doentes com cancro do pulmão de não-pequenas células (CPNPC). Os marcadores citoqueratina 19 (CK-19), antigénio carcinoembrionário (CEA), molécula de adesão celular epitelial (EPCAM), sialyl-Lewis X e CD44 foram determinados nos aspirados ganglionares de 33 doentes com neoplasia e 17 controlos 10 Ultrassonografia através de citometria de fluxo (CF) e reação em cadeia da polimerase em tempo real (RTPCR). Os doentes com CPNPC possuíam um compartimento celular epitelial significativamente aumentado e com marcação superior de CK-19 comparativamente ao grupo de controlo. O compartimento imune foi também analisado nestas amostras e revelou-se alterado no CPNPC com aumento da população de monócitos e diminuição das subpopulações linfocitárias. Os transcriptos de CK-19, CEA e EPCAM estavam elevados nos doentes com cancro do pulmão, identificando-se uma correlação positiva entre estes marcadores e o tamanho da lesão primária. Concluiu-se que a identificação de CK-19, CEA e EPCAM nas amostras obtidas por ecoendoscopia e avaliadas por CF e RTPCR foi viável, podendo auxiliar na deteção de metástases ganglionares no CPNPC. O quarto estudo envolveu a combinação da ecoendoscopia brônquica radial com uma criosonda para o diagnóstico de lesões pulmonares sólidas periféricas. Foi determinada a viabilidade, rentabilidade diagnóstica, tamanho das amostras e segurança do método. Lesões inferiores a 40mm foram localizadas por ultrassonografia sendo os doentes randomizados para a realização de biópsias transbrônquicas com pinça seguidas por criosonda ou vice-versa. Nos 39 casos incluídos a lesão foi visualizada pela minisonda em 31 doentes (79.5%), com 80.6% de prevalência de cancro do pulmão na amostra. A rentabilidade diagnóstica da pinça de biópsia foi 61.3% e da criosonda foi 74.2%. O tamanho do tecido adquirido pelas criobiópsias foi significativamente maior do que o alcançado por pinça (11.17mm2 vs. 4.69mm2, p<0.001). Ocorreu um único caso de hemorragia moderada, controlada através de medidas conservadoras. As biópsias transbrônquicas com criosonda sob orientação de ecoendoscopia radial foram seguras e eficazes na obtenção de amostras histológicas. O quinto estudo determinou o valor diagnóstico da ecografia transtorácica na identificação de malignidade em doentes com derrame pleural de natureza indeterminada. Foram examinados de forma prospetiva 154 doentes. Os resultados clínicos e radiológicos de cada caso foram ocultados ao executante do exame que gerou imagens estáticas e vídeos ultrassonográficos relevantes. Estes foram posteriormente visualizados, sendo as suas características classificadas por revisores independentes e comparadas com o diagnóstico definitivo. Em 66 casos o diagnóstico foi de derrame pleural maligno (68.2% com cancro do pulmão) e em 67 de derrame benigno. A ecografia torácica obteve 80.3% de sensibilidade, 83.6% de especificidade, 81.2% de valor preditivo negativo e 82.8% de valor preditivo positivo na deteção de malignidade. A nodularidade pleural ou diafragmática, espessamento pleural superior a 10mm e sinal de swirling foram significativamente diferentes (p<0.001) sendo sugestivos de derrame maligno. A existência de nodularidade pleural e ausência de broncograma aéreo ecográfico aumentaram a probabilidade de malignidade (OR 29.0 e OR 10.4, respetivamente). A ecografia transtorácica permitiu diferenciar derrame pleural maligno do benigno. A existência de nódulos pleurais constituiu o fator discriminador mais relevante. Em conclusão, os resultados desta tese possibilitam uma melhor compreensão do papel da ecoendoscopia brônquica (linear e radial) e ecografia transtorácica no diagnóstico e estadiamento do cancro do pulmão, com implicações e aplicabilidade na prática clínica.------------- ABSTRACT: In recent years ultrasonography has emerged as an important instrument in the diagnosis of thoracic diseases. Technological progress has enabled the design of new equipment such as radial and linear endobronchial ultrasound. In addition, indications for transthoracic echography were established. One of the main diseases responsible for the progression of chest sonography was lung cancer, the leading cause of cancer mortality worldwide. The applicability and knowledge of the role of ultrasonography in diagnosing and staging lung cancer is not depleted, persisting foci of controversy and scientific doubt that we intend to elucidate. The present thesis was organized into five chapters: the first included a general introduction regarding chest ultrasound, lung cancer and their combination; the second emphasized the main objectives; the third summarized the methodology used; the fourth encompassed the five published studies, subsequently described, and the fifth included a concise discussion, the main findings and future perspectives. The first study evaluated the diagnostic yield, safety and learning curve in a cohort of 179 patients submitted to linear endobronchial ultrasound. According to procedure indications, the patients were divided into three groups: (1) diagnosis, (2) diagnosis and staging, and (3) staging. For the first, second and third groups, endobronchial ultrasound sensitivity was 86.1%, 86.7% and 95% respectively and accuracy was 87.5%, 93.1% and 97.7% respectively. Practise led to an increase number of punctured sites per patient, in a shorter period of time and without complications, proving the safety and efficacy of the method when performed in the Portuguese population by expert echoscopists. The second study was conducted to determine the efficacy and cost of linear endobronchial ultrasound performed through the airway and/or oesophagus for diagnosis of lesions suggestive of lung cancer, after failure of conventional techniques. Of the patients prospectively enrolled a definitive diagnosis was reached in 106 cases (87.6%). The overall sensitivity for the diagnosis of lung cancer was 89.8%, specificity was 100%, positive predictive value was 100%, negative predictive value was 20% and accuracy was 90.1%. In conclusion, this global ultrasonographic strategy avoided diagnostic surgical procedures in patients that had undergone flexible bronchoscopy or computed tomography-guided transthoracic needle aspiration, providing a significant cost reduction. In the third study, the feasibility and role of linear endobronchial ultrasound combined with molecular techniques in the evaluation of tumour antigens and patterns of lymph node metastasis in patients with non-small cell lung cancer (NSCLC) was investigated. Cytokeratin 19 (CK-19), carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EPCAM), sialyl Lewis-X and CD44 were determined in lymph node aspirates of 33 lung cancer patients and 17 controls, using flow cytometry (FC) and reverse transcription polymerase chain reaction (RT-PCR). In patients with NSCLC the epithelial cell compartment was significantly increased nd showed brighter CK-19 staining, compared to the control group. In NSCLC patients the immune compartment revealed an increased monocyte population and decreased lymphocyte subsets. The transcripts of CK- 19, CEA and EPCAM were higher in lung cancer patients and a positive correlation between these markers and the size of the primary lesion was also found. We concluded that the identification of CK-19, CEA and EPCAM in endobronchial ultrasound samples, using RT-PCR and FC was feasible and might aid in the detection of NSCLC lymph node metastases. The fourth study involved the combination of the radial endobronchial ultrasound with the cryoprobe for diagnosing solid peripheral lung lesions. We determined the feasibility, diagnostic yield, sample size and safety of the method. Lesions less than 40mm were located by ultrasound and forceps or cryobiopsies were performed in a randomized order. Of the 39 cases included, the lesion could be visualized by the miniprobe in 31 patients (79.5%), and lung cancer prevalence was 80.6%. The diagnostic yield of the biopsy forceps was 61.3% and for the cryobiopsy was 74.2 %. Cryobiopsies were significantly larger than forceps biopsies (11.17mm2 vs. 4.69mm2, p<0.001). There was only one case of moderate bleeding that was controlled by conservative measures. Transbronchial cryobiopsies under radial endobronchial ultrasound guidance were safe and effective in obtaining histological samples. The fifth study determined the diagnostic value of transthoracic sonography in predicting malignancy in patients with an undiagnosed pleural effusion. One hundred and fifty four patients were prospectively scanned. Relevant ultrasound images and videos were generated by an operator blinded to clinical and radiological results. These were subsequently visualized, its characteristics classified by independent reviewers and compared to the final diagnosis. A malignant pleural effusion was diagnosed in 66 cases (68.2 % with lung cancer) and a benign effusion in 67 cases. Thoracic ultrasound had a sensitivity of 80.3 %, specificity of 83.6%, negative predictive value of 81.2 % and positive predictive value of 82.8% to detect malignancy. The presence of pleural or diaphragmatic nodularity, pleural thickening greater than 10mm and swirling signal were significantly different (p<0.001 ), being suggestive of malignant effusion. The existence of pleural nodularity and absence of lung air bronchogram were more likely to indicate malignancy (OR 29.0 and OR 10.4, respectively). Transthoracic ultrasonography permits the distinction between malignant and benign pleural effusions. Pleural nodules were the most relevant feature. In conclusion, the results of this thesis provide a better understanding of the role of endobronchial ultrasound (linear and radial) and transthoracic sonography in lung cancer diagnosis and staging, with direct implications and applicability in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this work was the development of polymeric structures, gel and films, generated from the dissolution of the Chitin-Glucan Complex (CGC) in biocompatible ionic liquids for biomedical applications. Similar as chitin, CGC is only soluble in some special solvents which are toxic and corrosive. Due to this fact and the urgent development of biomedical applications, the need to use biocompatible ionic liquids to dissolve the CGC is indispensable. For the dissolution of CGC, the biocompatible ionic liquid used was Choline acetate. Two different CGC’s, KiOnutrime from KitoZyme and biologically produced CGC from Faculdade de Ciencias e Tecnologia (FCT) - Universidade Nova de Lisboa, were characterized in order to develop biocompatible wound dressing materials. The similar result is shown in term of the ratio of chitin:glucan, which is 1:1.72 for CGC-FCT and 1:1.69 for CGC-Commercial. For the analysis of metal element content, water and inorganic salts content and protein content, both polymers showed some discrepancies, where the content in CGC-FCT is always higher compared to the commercial one. The different characterization results between CGC-FCT and CGC-Commercial could be addressed to differences in the purification method, and the difference of its original strain yeast, whereas CGC-FCT is derived from P.pastoris and the commercial CGC is from A.niger. This work also investigated the effect of biopolymers, temperature dissolution, non-solvent composition on the characteristics of generated polymeric structure with biocompatible ionic liquid. The films were prepared by casting a polymer mixture, immersion in a non-solvent, followed by drying at ambient temperature. Three different non-solvents were tested in phase inversion method, i.e. water, methanol, and glycerol. The results indicate that the composition of non-solvent in the coagulation bath has great influence in generated polymeric structure. Water was found to be the best coagulant for producing a CGC polymeric film structure. The characterizations that have been done include the analysis of viscosity and viscoelasticity measurement, as well as sugar composition in the membrane and total sugar that was released during the phase inversion method. The rheology test showed that both polymer mixtures exhibit a non- Newtonian shear thinning behaviour. Where the viscosity and viscoelasticity test reveal that CGCFCT mixture has a typical behaviour of a viscous solution with entangled polymer chains and CGCCommercial mixture has true gel behaviour. The experimental results show us that the generated CGC solution from choline acetate could be used to develop both polymeric film structure and gel. The generated structures are thermally stable at 100° C, and are hydrophilic. The produced films have dense structure and mechanical stabilities against puncture up to 60 kPa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portuguese Science Foundation - project Electra PTDC/CTM/099124/2008 and the PhD grant SFRH/BD/45224. financial support: Professor E. Fortunato’s ERC 2008 Advanced Grant (INVISIBLE contract number 228144), “APPLE” FP7-NMP-2010-SME/262782-2 and “SMARTEC” FP7-ICT-2009.3.9/258203

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estágio, realizado na CrowdProcess, consistiu em integrar a equipa da empresa, trabalhando na área do Design de Comunicação, Web e Gráfico, integrado no Departamento de Comunicação da empresa. A CrowdProcess é uma plataforma de computação distribuída que utiliza o poder de processamento dos browsers ligados para correr tarefas de computação distribuída. Uma vez que se trata de um produto online, a maioria do trabalho desenvolvido diz respeito a design e desenvolvimento web e apenas uma pequena parte dedicada a design gráfico. O trabalho foi desenvolvido com as linguagens HTML, CSS e JavaScript. Foram tidos em consideração os princípios de Design, Usabilidade e Arquitectura de Informação, com principal foco na prototipagem dos vários objectos desenvolvidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ICAD2014, Campus de Caparica, Portugal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro/nano wrinkled patterns on cross-linked urethane/urea polymeric flexible free standing films with two soft segments, polypropylene oxide and polybutadiene, can be induced by UV-irradiation. The ability to write/erase these 3D structures, in a controlled manner, is the main focus of this work. The imprinting of the wrinkled structures was accomplished by swelling in an appropriate solvent followed by drying the membranes after the cross-linking process and UV irradiation. The surface tailoring of the elastomeric membranes was imaged by optical microscopy, scanning electronic microscopy and by atomic force microscopy. To erase the wrinkled structures the elastomers were swollen. The swelling as well as the sol/gel fraction and the UV radiation were tuned in order to control the wrinkles characteristics. It was found that the wrinkles wavelength, in the order of microns (1±0,25μm), was stamped by the UV radiation intensity and exposure time while the wrinkles' amplitude, in the order of nanometers (150-450 nm), was highly dependent on the swelling and sol/gel fraction. A prototype for volatile organic compounds detection was developed taking advantage of the unique 3D micro/nano wrinkles features.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paper presented at the Colloquium Gerpisa 2013, Paris (http://gerpisa.org/node/2085), Session n°: 19 New kinds of mobility: old and new business models

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Num mundo em crescente evolução é necessário tentar melhorar as condições de saúde global. Um factor importante para a prevenção e tratamento de doenças é o seu correcto diagnóstico. Uma vez que nem todos os países têm a mesma capacidade económica, existe a necessidade de se criar testes rápidos e baratos que possam ser acessíveis no mundo inteiro. Os point-of-care tests, como é o caso dos biossensores de glucose vastamente utilizados na monitorização da diabetes, apresentam uma solução para este problema. Os biossensores impressos em papel, em particular, são uma ferramenta que pode vir a ser muito útil na construção destes testes rápidos tornando-os mais “amigos do ambiente” e reduzindo os seus custos. O objectivo deste trabalho foi desenvolver biossensores enzimáticos, de segunda geração, impressos em papel e baseados na enzima glucose oxidase, para a detecção da glucose. Inicialmente foi feito um estudo de possíveis mediadores a utilizar, tendo-se escolhido o ferroceno por apresentar um limite de detecção adequado, ter apresentado um valor de potencial de redução relativamente baixo, 0.232 V vs pseudo ref. Ag/AgCl, ser um composto fácil de obter e com custos reduzidos. Os dispositivos baseiam-se em canais microfluídicos, eléctrodos e ligações eléctricas fabricadas em substrato de papel, utilizando as técnicas de impressão a cera, screen printing e inkjet printing. O circuito constituinte destes dispositivos foi feito recorrendo a tintas condutoras, sendo que, à tinta utilizada para o eléctrodo de trabalho foi incorporado o ferroceno. Sobre o eléctrodo de trabalho foi impressa glucose oxidase, utilizando a técnica de inkjet printing. Os eléctrodos fabricados apresentaram resposta à glucose, muito embora com baixa reprodutibilidade, podendo esta ser causada pela falta de controlo na preparação dos mesmos (manufactura manual e variabilidade da viscosidade da pasta usada no eléctrodo de trabalho). A técnica de inkjet printing em enzimas é ainda muito recente, existindo ainda alguns aspectos, como o seu efeito na actividade da enzima, que não foram avaliados neste projecto, mas que no futuro deverão ser estudados. Podemos concluir que, os eléctrodos deram uma resposta electroquímica consistente à adição de glucose, 8 mM- 30 mM, sendo que os mesmos foram reconhecidos no glucómetro comercial TRUETrackTM blood glucometer; no entanto, os valores de corrente dos dispositivos estavam abaixo do limite de detecção do instrumento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O envolvimento renal na hanseníase é diverso, incluindo glomerulonefrites, amiloidose e nefrite túbulo-intersticial. Um homem de 58 anos foi admitido com edema de membros inferiores e dispnéia. Na admissão, havia retenção de escórias nitrogenadas, anemia, hipercalemia e acidose metabólica, com necessidade de hemodiálise. Referia história de hanseníase virchoviana. Foi realizada biopsia renal, compatível com amiloidose. O paciente evoluiu estável, sem recuperação da função renal, permanecendo em tratamento hemodialítico. A hanseníase deve ser investigada em todo paciente com perda de função renal, sobretudo naqueles que apresentam lesões cutâneas ou outras manifestações sugestivas de hanseníase.